1 INST ALLA TION AND SER VICE MANUAL SHP-I&S-02 COMMERCIAL ELECTRIC W A TER HEA TERS 52, 82, 1 19 Gallon, 9 kW - 54kW Input Models FIG . 1 Fr ont V iew V ertical Round Models Installation and serv ice must be performed by Qualified Serv ice P ersonnel Only .
2 W ARNING: CONTENTS W ar ranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Safety W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Checking the Equipment . . . . . . . . . . . . . . . .
3 CODES The equipment shall be installed in acco rdance with those installation regulations in forc e in the local area where the installation is to be made. These shall be carefully followed in all cases. A uthor ities having jurisdiction shall be consulted befor e installations are made.
4 CLEARANCES FROM COMBUSTIBLE CONSTRUCTION FIG. 2 Clearances from Co mbustible Construction T ABLE - A CLEARANCES FROM COMBUSTIBLE CONSTRUCTION: Right Side - 0" Rear - 0" Left Side - 0".
5 INLET AND OUTLET CONNECTIONS For ease of ser vice, install unions on the c old water inlet and hot water outlet of the water heater . The cold water inlet connection is located on the lo wer left front side of the water heater . A manual shutoff valve should be installed upstream on the cold wat er source as an isolation device.
6 ELECTRICAL CONNECTIONS All installation proc edures in volving electric power connection should only be performed by a trained, certified electricians. FIG. 4 Electric P ower Co nnections - Electr ical Control Pa n e l W ARNING: W A TER HEA TER IS EQUIPPED FOR OPERA TION ON ONE V OL T AGE ONL Y .
7 JACKET ASSEMBL Y Outer Jack et - The out er jacket assembly is c onst ructed from hea vy gauge steel. The ext er ior surface is specially prepared and phosphat e coated to allow application of a multiple coat enamel paint pr ocess. This coating process insures a long life from the jack et assembly .
8 A main power t er minal block is provided for field connection of the branch power supply to the electric water heater . All internal pow er circuits to the immersion heating elements are c onnected to the load side of the main terminal block.
9 The limit is reset by pushing the r ed reset button on the limit. Operation of the limit control usually indicates a major problem with the heating elements or temperature contr ol. Do not contin ue to push the reset m ultiple times. The problem causing the r eset to function must be found and corrected to insur e proper operation.
10 W ARNING: HAZARD OF ELECTRICAL SHOCK - Before opening the electrical access panel to adjust the thermostat or ser vicing the water heater , make sur e the electrical supply to the water heater is turned "OFF". Failure t o do this could result in death, serious bodily injur y or propert y damage.
11 W ARNING: SHOULD O VERHEA TING O CCUR OR THE TEMPERA TURE CONTROLS F AIL TO SHUT OFF , TURN OFF OR DISCONNECT THE ELECTRICAL SUPPL Y A T THE MAIN POWER DISCONNECT , EXTERN AL TO THE APPLIANCE. DANGER • W ater temperature over 125°F (51.7°C) can cause severe burns instantly or death from scald.
12 IMMERSION HEA TING ELEMENTS FIG. 14 Immersion H e ating Element W ARNING: HAZARD OF ELECTRICAL SHOCK - Before opening the access panel t o remove or service the immersion heating elements, make sur e the elect rical supply to the water heat er is turned "OFF".
13 NOTE: The cold water supply m ust be left in the open position when the water heater is in use. 5. Check the near by hot water faucet t o verify that air is exiting the tank as it fills with water . Allow wate r to run until a constant flo w is obtained at the faucet.
14 SHUTDOWN PROCEDURE 1. T urn off the main electr ical power t o the water heater . If the power disc onnect point is out of sig ht, lock it in the open ("OFF") position and tag to prev ent unexpected application of power . 2. T urn the valve in the water heat er's cold water supply to the closed or "OFF" position.
Scale accumulation in the bott om of the storage tank may be remo ved by turning off main power and draining the tank. Once all wate r is remo ved, the hand hole access can be remo ved. This w ill allow large ac cumulations of scale to be cleaned from the bottom of the tank.
Revision Notes: Revision 2 (ECO #C02870) reflects the addition of the scald char t on page 10. CP -5M-1/09-Printed in U.S.A. 16 7. Clean remaining gask et recess on eac h screw-in element flange. Do not reuse element gask ets. 8. Install a new gask et on each element.
Een belangrijk punt na aankoop van elk apparaat Lochinvar Commercial Electric Water Heaters (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lochinvar Commercial Electric Water Heaters heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lochinvar Commercial Electric Water Heaters vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lochinvar Commercial Electric Water Heaters leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lochinvar Commercial Electric Water Heaters krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lochinvar Commercial Electric Water Heaters bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lochinvar Commercial Electric Water Heaters kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lochinvar Commercial Electric Water Heaters . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.