User’s Information Manual Models: 51 - 211 If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance MUST NOT be installed in any location where gasoline or flammable vapors are likely to be present.
2 Hazard definitions The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk level s or to important information concerning the life of the product.
User’s Information Manual Please read before proceeding The Knight Wall Mount Installation and Operation Manual along with the Knight Wall Mount Service Manual are for use only by a qualified heating installer/service technician. Refer only to this User’s Information Manual for your reference.
User’s Information Manual 1 Prevent combustion air contamination 4 If the boiler combustion air inlet is located in a laundry room or pool facility, for example, these areas will always contain hazardous contaminants.
User’s Information Manual 2 Maintenance schedule 5 Service technician (see the Knight Wall Mount Service Manual) General: • Reported problems • Inspect interior; clean and vacuum if necessary .
User’s Information Manual 2 Maintenance schedule 6 Maintenance procedures Boiler must be serviced and maintained WARNING The boiler must be inspected and started annually at the beginning of the heating season by a qualified service technician.
User’s Information Manual 2 Maintenance schedule (continued) 7 4. Fill with fresh water until the water begins to pour out of the drain. 5. Replace the cap. Press the cap onto the trap until the cap makes contact with the drain. 6. Replace the retaining screw.
User’s Information Manual 2 Maintenance schedule 8 WARNING Have leaks fixed at once by a qualified service technician. Failure to comply could result in severe personal injury, death, or substantial property damage.
User’s Information Manual 9 3 Operating instructions o C.
User’s Information Manual 10 4 SMART SYSTEM control module Figure 4-1 Control Panel Knight wall mount control module Use the control panel (FIG. 4-1) to set temperatures, operating conditions, and monitor boiler operation.
User’s Information Manual 11 4 SMART SYSTEM control module (continued) Temperature Units The control can be configured to display temperature in either °F or °C. This parameter can be changed by the user or the installer by accessing the Temperature Units parameter .
User’s Information Manual 12 4 SMART SYSTEM control module Status Display Screens Section Display Description A (Boiler Status Bar) STANDBY The unit has not received a call for heat from a remote thermostat nor has it received a call for heat from a DHW thermostat.
User’s Information Manual 13 4 SMART SYSTEM control module (continued) Status Display Screens (cont’d) Section Display Description C (Operational Information) SYSTEM: The temperature read by the system supply sensor (if connected). TANK: The temperature read by the tank sensor (if connected).
User’s Information Manual 14 4 SMART SYSTEM control module Status Display Screens (cont’d) Section Display Description E (NAVIGATION Dial Function) Turning the NAVIGATION dial will select the next or previous Status Screen. Pressing the NAVIGATION dial will show the next fault, NSB (Night Setback) trigger, or ramp delay setting.
15 Notes User’s Information Manual.
Revision Notes: Revision A (ECO C05747) initial release. Reflects the new model numbers for the Knight Wall Mount upgrade. Revision B (ECO C07072) reflects the change in design of the manual air vent, the update of FIG. 2-3 on page 8, and the reorganization of the information on pages 10 and 11 for the user password information.
Een belangrijk punt na aankoop van elk apparaat Lochinvar KNIGHT 51-211 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lochinvar KNIGHT 51-211 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lochinvar KNIGHT 51-211 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lochinvar KNIGHT 51-211 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lochinvar KNIGHT 51-211 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lochinvar KNIGHT 51-211 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lochinvar KNIGHT 51-211 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lochinvar KNIGHT 51-211 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.