37 X-29, X-39 and X-49 INST ALLA TION AND OPERA TION INSTRUCTIONS.
38 TABLE OF CONTENTS INTRODUCTION ............................................................................................... 1 SPECIFICATIONS ............................................................................................ 1 INSTALLATION -Transducer .
1 SPECIFICATIONS - All Units Dimensions ....................... 5.9" W x 5.35" H x 3.4" D Input Voltage .................... 10 - 15 vDC Current Drain .................... 350 ma (lights off) ........................... 500 ma (lights on) Transmitter Frequency .
2 Transducer Installation Some of the models covered by this manual have a transom-mount transducer included. The following are installation instructions for this transducer. The “kick-up” mounting bracket helps prevent damage if the transducer strikes an object while the boat is moving.
3 Shoot-thru-hull v.s. Transom Mounting Typically, shoot-thru-hull installations give excellent high speed opera- tion and good to excellent depth capability. There is no possibility of damage from floating objects. It can't be knocked off when docking or loading on the trailer.
4 2. Slide the transducer between the two ratchets. T emporally slide the bolt though the transducer assembly and hold it against the transom. Looking at the transducer from the side, check to see if it will adjust so that its face is parallel to the ground.
5 CAUTION! CLAMP THE TRANSDUCER CABLE TO TRANSOM NEAR THE TRANSDUCER. THIS WILL HELP PREVENT THE TRANSDUCER FROM ENTERING THE BOAT IF IT IS KNOCKED OFF AT HIGH SPEED. GOOD LOCATION POOR ANGLE POOR LOCATION GOOD LOCATION TRANSOM SIDE VIEW 4. Hold the transducer and bracket assembly against the transom.
6 5. Remove the transducer from the bracket and re-assemble it with the cable passing through the bracket over the bolt as shown above. At- tach the transducer to the transom. Slide the transducer up or down until it’s aligned properly on the transom as shown above.
7 SHOOT-THRU-HULL The transducer installation inside a fiberglass hull must be in an area that does not have air bubbles in the resin or separated fiberglass layers.
8 TRANSDUCER LOCATION (HIGH SPEED) TRANSDUCER LOCATION (TROLLING SPEED) 2. Follow the instructions on the epoxy package and mix it thoroughly. Do not mix it too fast, as it will cause bubbles to form in the epoxy.
9 TRANSDUCER AIMED TOO FAR FORWARD hull. Place the transducer into the epoxy, twisting and turning it to force any air bubbles out from under the transducer face. The face of the transducer should be parallel with the hull, with a minimum amount of epoxy between the hull and transducer.
10 3 amp FUSE 12 VOLT BATTERY BLACK WIRE RED WIRE TO SPEED/TEMP SENSOR (X-39 and X-49 ONLY) POWER CONNECTIONS - All units This unit works from a 12 volt DC system only. For the best results, run the power cable directly to the boat’s battery. Keep the power cable away from other boat wiring, especially the engine’s wires.
11 Bracket Installation You can install the sonar unit on the top of a dash or from an overhead with the supplied bracket. It can also be installed in the dash with an optional IDA-3 mounting kit. If you use the supplied bracket, you may be interested in the optional GBSA-1 swivel bracket kit.
12 SPEED/TEMPERATURE SENSORS The X-39 and X-49 can use up to three optional temperature sensors which can monitor surface water, live well, air, and virtually any other tempera- ture. You do need to be careful when purchasing the temperature sensors, however.
13 Sensor Chart (Note: Do not use these sensors in any other combination.) ST-TBK = 1 speed sensor and 1 temperature display ST-T BK + TS-2BK = 2 temp sensors and one speed sensor ST-TBK + TS-2BK + TS.
14 Three Temperature Sensors (Water, T-2, and T-3) Three Temperature Sensors plus Speed (Water, T-2, T-3, and Speed) TS-12 BK TS-3 BK ST-TBK TS-2 BK TS-3 BK X-39 or X-49 POWER CABLE Sensor Chart (Note: Do not use these sensors in any other combina- tion.
15 KEYBOARD BASICS The unit sounds a tone when you press any key. This tells you the unit has accepted a command. PWR/CLEAR Use this key to turn the unit on. It also clears menu selections and the menus from the screen. This key also turns the unit off.
16 OPERATION MENUS This unit uses menus to guide you through the unit’s functions and features. The menu key accesses these features, allowing you to cus- tomize the unit to your particular needs and water conditions. All you have to do to leave one menu and enter another is press the menu key repeatedly.
17 After you select the desired range, press the PWR key to clear the display. If you wait a few seconds, it will automatically clear. This unit has the following ranges: 10, 20, 40, 60, 120, 240, 480, and 900 feet. and 5, 10, 20, 40, 60, 100, 200, and 300 meters.
18 This means the unit is tracking the bottom in a zoom window, always keeping it on the display. Press the up arrow key to decrease the zoom size, press the down arrow key to increase the zoom size. When the unit is switched into the zoom mode, the letters “ZM” appear at the top of the screen.
19 RANGE - Upper and Lower Limits You can change the upper and lower range limits when the unit is in the manual mode. This lets you "zoom" in on segments of the water as small as 10 feet. In other words, you can set the upper limit to 25 feet and the lower limit to 35 feet, regardless of the bottom depth.
20 SENSITIVITY The sensitivity menu lets you control the unit’s ability to pick up echoes. A low sensitivity level excludes much of the bottom information, fish signals, and other detail. High sensitivity settings lets you see features, but it can also clutter the screen with noise and other unwanted signals.
21 Grayline ® is adjustable. Since it shows the difference between strong and weak echoes, changing the level may require a different sensitivity setting. To change the Grayline level, first press the MENU key until the Grayline menu appears. Now press the up arrow key to increase the level, the down arrow to decrease it.
22 CHART SPEED The rate echoes scroll across the screen is called the chart speed. It’s adjustable by pressing the menu key until the chart speed menu appears. Chart speed is set to maxi- mum when the unit is first turned on. To decrease it, press the down arrow key.
23 DISPLAY MODE The X-29 has three different screen modes. The X-39 and X-49 has eight modes. To change modes, press the MENU key until the “DISP MODE” (Display Mode) menu appears. Then press the up or down arrow keys until the desired mode number appears.
24 X-39 and X-49 ONLY CHT 1 (Chart #1) This is the default mode used when the unit is first turned on. It has the following features: 1. Automatic On 2. Fish ID Feature On 3. Digital Depth Display On CHT 2 (Chart #2) Same as Chart-1, but with water tempera- ture added.
25 X-39 and X-49 ONLY (cont.) CHT 4 (Chart #4) Same as Chart-1, but with water tempera- ture and speed added. CHT 5 (Chart #5) This is the High Speed Scroll mode. It shifts the chart speed into high gear, scrolling ech- oes at a high rate. It has the following fea- tures: 1.
26 X-39 and X-49 ONLY (cont.) DIG 2 (Digital #2) Digital depth, water temperature, speed, and distance log (odometer) show on this page. To reset the log, turn the unit off and back on again. DIG 3 (Digital #3) Digital depth, water temperature, T-2 tem- perature, and T-3 temperature all show on this screen.
27 ALARMS FISH ALARM The Fish Alarm sounds a tone when a fish symbol appears on the screen. To use the fish alarm, press the menu key until the “FISH ALARM” menu appears on the screen. Now press the up arrow key to turn the alarm on. Repeat the above steps to turn the fish alarm off.
28 Deep Alarm The deep alarm adjusts the same as the shallow alarm. Use the “DEEP ALARM” menu to adjust the deep alarm. When the bottom signal goes deeper than the setting, an alarm tone sounds. LIGHTS The display is backlighted for night use. To turn the backlights on or off, press the menu key repeatedly until the BACK LIGHT menu appears.
29 reach the maximum or minimum level, a tone sounds alerting you to the limits. The menu will clear automatically after a few seconds or you can press the PWR key to clear the screen. ASP (Advanced Signal Processing) ASP is a program embedded in the computer that is specifically designed to eliminate noise.
30 TROUBLESHOOTING - IMPORTANT INFORMATION! If your unit is not working, or if you need technical help, please use the following troubleshooting section before contacting the factory customer service department. It may save you the trouble of returning your unit.
31 the digital will flash continuously. It may change the range to limits far greater than the water you are in. If this happens, place the unit in the manual mode, then change the range to a realistic one, (for example, 0- 100 feet) and increase the sensitivity.
32 ELECTRICAL NOISE A major cause of sonar problems is electrical noise. This usually appears on the sonar’s display as random patterns of dots or lines. In severe cases, it can completely cover the screen with black dots, or cause the unit operate erratically, or not at all.
33 LOWRANCE ELECTRONICS FULL ONE-YEAR WARRANTY “We", “our”, or “us” refers to LOWRANCE ELECTRONICS, INC., the manufacturer of this product. “You” or “your” refers to the first person who purchases this product as a consumer item for personal, family, or household use.
34 Notes:.
35 How to Obtain Service (Canadian Customers Only) We back your investment in quality products with quick, expert service and genuine Eagle replacement parts. If you need service or repairs, contact the Lowrance Factory Customer Service Department at the toll-free number listed below.
36 LITHO IN U.S.A. 988-0105-85 LOWRANCE ELECTRONICS, INC. 12000 E SKELLY DR TULSA OK 74128 Your unit is covered by a full one-year warranty. (See inside for complete warranty details.
Een belangrijk punt na aankoop van elk apparaat Lowrance electronic X-39 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lowrance electronic X-39 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lowrance electronic X-39 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lowrance electronic X-39 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lowrance electronic X-39 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lowrance electronic X-39 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lowrance electronic X-39 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lowrance electronic X-39 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.