Gebruiksaanwijzing /service van het product TX9100E van de fabrikant Lux Products
Ga naar pagina of 32
1. SYSTEM COMPA TIBILITY . . . . . . . . 2 2. FEA TURES . . . . . . . . . . . . . . . . . . 3 3. TOOLS REQUIRED . . . . . . . . . . . . . 3 4. SELECTING A LOCA TION . . . . . . . . . 4 5. REMOVE OLD THERMOST A T . . . . . . 5 6. MOUNT NEW THERMOST A T .
2 1. SYSTEM COMP A TIBILITY The electrical rating for this thermostat is 1.5A per terminal, with a maximum of 2.0A for all terminals combined. COMP A TIBLE WITH: • Most 24-volt heating and cooling s.
3 2. THERMOST A T FEA TURES • Universal Compatibility (Conventional or Heat Pump) • 7 Day Programming • 4 Periods per Day • Quick Copy Programming • Exclusive LUX Speed Dial ® • Luxlight .
4 CAUTION: This thermostat is protected against normal static electric discharges; however touching a grounded metal object before touching your thermostat will minimize the risk of damaging the unit in extremely dry weather .
5 • Y our thermostat is a precision electronic instrument; please handle it with care to avoid damage. 5. REMOVE OLD THERMOST AT 1. T urn OFF the electricity to all heating and cooling components. Do not turn the electricity back on until all work is completed.
6 3. Remove the body from the thermostat’ s base by pressing the thumb latch at the bottom center of the unit and swinging the body away from the base. NOTE: If you are mounting the base to soft material like plasterboard or if you are using the old mounting holes, the screws may not hold.
7 • All of the dashed wires shown in the following wiring diagrams are either optional, or their usage depends upon your specific system type or brand. For example: Diagram #1 shows the fan wire as optional. If your system does not have a fan, than this terminal will not be used.
8 RC G RH Y W2 W1 A OB C FA N HEA TER SYSTEM XFMR TYPICAL 24-VOL T , 2 OR 3 WIRE, CONVENTIONAL, 1-ST AGE, HEA TING ONL Y SYSTEMS (INCLUDING MILLIVOL T) G F RH R V C W1 W H 4 Factory RH-RC Jumper Wire .
9 RC G RH Y W2 W1 A OB C 3-WIRE HYDRONIC ZONE V A L VE SYSTEM XFMR TYPICAL 24-VOL T , CONVENTIONAL, 1-STAGE, HOT W A TER HEA T ONL Y SYSTEMS WITH A 3-WIRE ZONE VAL VE A 6 RH R V 3 Y W1 W H 4 C Factory.
10 RC G RH Y W2 W1 A OB C FA N A/C UNIT SYSTEM XFMR TYPICAL 24-VOL T , 3 WIRE, CONVENTIONAL, 1-ST AGE COOLING ONL Y SYSTEMS RC R 5 G F Y C* 6 C Factory RH-RC Jumper Wire Installed O P T I O N A L #3.
11 RC G RH Y W2 W1 A OB C FA N HEA TER SYSTEM XFMR TYPICAL 24V , 4 WIRE, CONVENTIONAL HEA TING AND COOLING SYSTEMS WITH 1 ST AGE HEA T AND 1 ST AGE COOL A/C UNIT RH R V G F Y C* 6 W1 W H 4 C Factory R.
12 RC G RH Y W2 W1 A OB C FA N SYSTEM XFMR TYPICAL 24V , 5 WIRE, CONVENTIONAL HEA TING AND COOLING SYSTEMS WITH 2 ST AGE HEA T AND 1 ST AGE COOL HEA T SECOND ST AGE HEA T FIRST ST AGE A/C UNIT W2 RH R.
13 RC G RH Y W2 W1 A OB C TYPICAL 24V , 4 WIRE, HEA T PUMP SYSTEMS WITH 1 ST AGE HEA T AND 1 ST AGE COOL FA N SYSTEM XFMR HEA T PUMP UNIT CHANGE- OVER VA LV E ** Use either “O” or “B” T ermina.
14 RC G RH Y W2 W1 A OB C TYPICAL 24V , 5 WIRE, HEA T PUMP SYSTEMS WITH 2 ST AGE HEA T AND 1 ST AGE COOL FA N SYSTEM XFMR HEA T PUMP UNIT CHANGE- OVER VA LV E ** Use “O” or “B” T erminals, Nev.
15 RC G RH Y W2 W1 A OB C FA N HEA TER HEA T XFMR TYPICAL 24V , 5 WIRE, CONVENTIONAL HEA TING AND COOLING SYSTEMS WITH 1 ST AGE HEA T AND 1 ST AGE COOL, WITH TWO 24-VOL T TRANSFORMERS A/C UNIT COOL XF.
16 8. HARDWARE SETUP OPTIONS NOTE: All of the settings, options, and components listed in the following section are located on the rear of the thermostat, on the circuit board. GAS/ELEC. F AN OPERA TION This is a plastic jumper cap, which is labeled as JP2.
17 [1] SYSTEM MODE This setting tells the thermostat about the type of heating and cooling equipment that it is controlling, so that the system is operated properly . This switch needs to be in the OFF (NON-HP) position if you have a furnace or conventional heating and air conditioning system.
18 [4] SCALE This setting determines how the thermostat displays all temperatures on the screen. Switch position OFF is F°, and ON is C°. [5] TIME This setting determines how the thermostat displays the clock and all other time values on the screen.
19 NOTE: When you are finished performing your installation and setup options, please remove the thin plastic film that is protecting the LCD display screen on the front of the thermostat. This plastic may or may not be present, and is evident by the appearance of fake digits appearing on the display screen.
20 needed. With the Fan switch in the ON position, the fan will operate even when the T emperature Mode switch is in the OFF position to provide air circulation only . When the fan is running, the word “F AN” is displayed in the temperature portion of the display screen.
21 buttons, adjust the clock to the current time, and make sure that the proper AM or PM indication is observed as appropriate. T o assist with large adjustments, the clock digits will increment rapidly in either direction if the UP or DOWN buttons are held pressed for more than a few seconds.
22 TEMPERA TURE OVERRIDE A T emperature Override occurs in Run mode, in either Heat or Cool, anytime the user adjusts the set temperature to a value that differs from the stored program temperature for that day and time. When the thermostat is in an Override, the word “OVERRIDE” will appear in the temperature area of the display .
23 EMERGENCY HEA T (Heat Pump Configuration Only) While in normal Heat mode with the rotary dial in the RUN position, one single press of the COPY/EMER button will activate Emergency Heat mode. A single press again will end Emergency Heat mode, and return back to normal Heat mode.
24 AIR FIL TER MONITOR In systems that have a blower fan and air ducts, this feature is to assist you with proper maintenance and periodic replacement of the filter located in your heating or cooling system. The Air Filter Monitor counts the duration of filter usage that has occurred, since the last time the Filter Monitor has been reset.
25 save energy in some cases. There is only one Swing setting, and this determines the cut-in and cut-out points for both the first and second stages (if present), and affects both heating and cooling. T o change the Swing setting, ensure that the System Mode switch is in the OFF position and the rotary dial is in RUN.
26 OFFSET : After the swing value has been accepted, the words “SET :” and “OFFSET” will be shown on the screen. This setting is shown as a number of degrees, and is similar in nature to the swing however it only effects the operation of the second (auxiliary) heating stage, if present.
27 four -digit code to unlock them. Y ou may use either the default lock code of “0000”, or your own code number (see “TO CHANGE THE LOCK CODE:”). TO LOCK THE THERMOST A T : Ensure the rotar y dial is in the RUN position. Press the NEXT button for at least 2 seconds.
28 TO CHANGE THE LOCK CODE: First ensure that the thermostat is unlocked and the rotary dial is in the RUN position. Press the NEXT button for at least 2 seconds. The words “ENTER CODE” will appear on the screen, above “0000”. Now press the HOLD button for at least 2 seconds.
29 13. PROGRAMMING SET HEA T PROGRAM Rotate the dial to HEA T PROGRAM. Y ou will be programming the heat periods for all seven days, one after the other starting with Monday . The first period is MORN. Using the UP and DOWN buttons, set the start time for this period, and then push the NEXT button to proceed.
30 will appear on the screen, with one of the days flashing above. Using the UP/DOWN buttons, select the day that you want to copy from. Press the NEXT button once. Y our “copy from” day should be on steady with the following day flashing. Use the UP/DOWN buttons to select the day that you would like to copy to.
31 swinging the body towards you, up and away from the base. Remove the used batteries from the battery tray and discard appropriately . Install two new Energizer ® or DURACELL ® “AA” size alkaline batteries into the battery tray . Obser ve the polarity markings shown in the battery compartment to ensure proper installation.
Mt. Laurel, New Jersey 08054, USA http://www .luxproducts.com 5 : 36 72 HEAT T U D AY F PM limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the location from which the purchase was made, along with proof of pur chase.
Een belangrijk punt na aankoop van elk apparaat Lux Products TX9100E (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lux Products TX9100E heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lux Products TX9100E vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lux Products TX9100E leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lux Products TX9100E krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lux Products TX9100E bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lux Products TX9100E kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lux Products TX9100E . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.