Gebruiksaanwijzing /service van het product Scamax 2600 van de fabrikant ABL electronic
Ga naar pagina of 42
DpuScan 4.0 Special Scanner Options for Scamax 2600 and 5000.
Copyrights © 1997-2003 J&K Imaging (Marietta, GA/USA) and Janich & Klass (Wuppertal, Germany) . All rights reserved . Printed in Germany. The information contained in this documentation is the property of J&K Imaging and Janich & Klass .
Scanner Options Scamax 2600 / 5000 DpuScan Table of Contents 1 Description of the Scanner Options ............................................................................................. ... 5 1.1 Introduction ....................................
DpuScan Scamax 2600 / 5000 Scanner Options Table of Illustrations Illustration 1 – Inotec Properties Tab: Device ................................................................................. ....... 6 Illustration 2 – Inotec Options: Front Page .
Scanner Options Scamax 2600 / 5000 DpuScan 1 Description of the Scanner Options 1.1 Introduction This documentation is valid for the following scanners of the company InoTec: • Scamax 2600 / Scamax .
DpuScan Scamax 2600 / 5000 Scanner Options 2 Device Properties The first page gives setting possibilities for double feed detection, length control, manual feeding mode, and fill color options.
Scanner Options Scamax 2600 / 5000 DpuScan After Start of Document (5cm) The ultrasound sensor becomes active only after the first two inches of each original.
DpuScan Scamax 2600 / 5000 Scanner Options Please make sure the single sheet processor is switched on at the scanner. Another possibility to effectively work with the manual feeder is the "Ignore paper status" function on the Options property tab.
Scanner Options Scamax 2600 / 5000 DpuScan 3 Image Processing Options To optimize image quality you can set different image processing parameters. They are offered on the next two pages, separately for Front and Back camera.
DpuScan Scamax 2600 / 5000 Scanner Options DTplus Threshold (two-dimensional) If the scanner has the DTplus board (optional), several image lines can be considered for the black/white decision. As with the Automatic Threshold, not only the value itself, but also deviations in its surroundings are considered.
Scanner Options Scamax 2600 / 5000 DpuScan For improved barcode reading, and for results at scan resolutions of any level other than 200 dpi, we recommend that the user selects their settings using notchfilter (values 30 to 59).
DpuScan Scamax 2600 / 5000 Scanner Options 4 Image Index If the device is equipped with the corresponding option, a he ader is created for each image. This header may be used for indexing. Illustration 3 – Inotec Options: Index Refresh Click the Refresh button to get and display the latest Image Header from the scanner.
Scanner Options Scamax 2600 / 5000 DpuScan Mode The mode is a combination of all settings made for Patchcode recognition, for counter behavior, for endorser output, and for the rules to control the counters. This option allows the user to select from one of the 16 operating modes.
DpuScan Scamax 2600 / 5000 Scanner Options If the counters are correspondingly set and enabled in the module Patchcode-Controlled Index , they will be set and incremented as per the defined rules. So, for ex ample, a document with the Patchcode ”Patch I” can indicate a new chapter.
Scanner Options Scamax 2600 / 5000 DpuScan 5 Exp anded Endorser Control for Scamax 2600 5.1 What it is and How it Works The Patchcode Controlled Index by Janich & Klass is intended as a method to control the scanning process, to generate a data structure specific for each image, and simultaneously endorse the paper .
DpuScan Scamax 2600 / 5000 Scanner Options Illustration 5 – Scanner Properties with Links to the Patchcod e Controlled Index Note: If the required software modules are not installed, the button and the dropdown list for the modes will not appear. When the scanner has the required hardware, the "Index" page is shown.
Scanner Options Scamax 2600 / 5000 DpuScan 48 49 50 51 52 53 54 55 56 M o d e = - 0 lf 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 L i n e L e n g t h = - - - - - - - 0 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 P a g e L e n g t h = - - - - - - - 0 lf 104 105 106 107 108 109 .
DpuScan Scamax 2600 / 5000 Scanner Options 288 289 290 291 292 293 294 295 R e v = - 0 296 297 298 299 300 301 302 303 304 305 306 307 308 ... 322 323 I A _ F i x _ e x t = - - - 324 325 326 327 328 329 330 331 332 333 334 335 336 337 P a t c h c o d e = - 0 338 339 340 341 342 343 344 345 346 347 348 349 350 E n d o r s e d = - 0 351 .
Scanner Options Scamax 2600 / 5000 DpuScan Patchcode returns these values: 0 Patch T 1 Patch II 2 Patch III 3 Patch I 4 Patch IV 5 Patch VI Endorsed (0 or 1) Note: All multi-digit numbers will be aligned to the right without any leading zero s. The format is completely independent of the formats chosen for the printout.
DpuScan Scamax 2600 / 5000 Scanner Options The Page Counter A is the rightmost part of the Image Address in the Header. Counter A fills Bytes 142 to 151 of the Image Header. Chapter Counter B Several documents form a chapter. The Chapter Counter B may be incremented when a chapter separator sheet (e.
Scanner Options Scamax 2600 / 5000 DpuScan Illustration 6 – Counter Confirmation 5.2.4 Flags There are two flags that can be managed by the Patchcode Controlled Index. The latched flag can be set by means of a rule after a specific event. It remains set until it is reset by another rule, or by the beginning of a new scan job.
DpuScan Scamax 2600 / 5000 Scanner Options 5.2.6 Mode The Mode is the summary of all settings and rules that will be described in the succeeding paragraphs.
Scanner Options Scamax 2600 / 5000 DpuScan Illustration 7 – Patchcodes As with the other dialogs, the buttons along the bottom work in the same well-known manner: OK Closes the dialog box and saves your entries. Cancel Closes the dialog without saving your entries.
DpuScan Scamax 2600 / 5000 Scanner Options 5.3.1 Patchcodes With the "Patchcodes" tab several settings can be adjusted concerning the search for Patchcodes. The search can be restricted to the front or rear si de of a document, or to a specific search area on the page.
Scanner Options Scamax 2600 / 5000 DpuScan 5.3.2 How to Set and to Trigger Counters Illustration 8 – Counter Modes Field Width This define how many digits the counter should have. If it is set to, for example, 3 digits, the counter will count from 0 to 999.
DpuScan Scamax 2600 / 5000 Scanner Options Page Counter A will always be incremented by 1. Only if Counter A was reset as the result of an event (Patchcode found, for example) will the counter be incremented for the next image by a user-defined value.
Scanner Options Scamax 2600 / 5000 DpuScan 5.3.3 How to Print Counters Here, you configure the format to print counts of the counters on a document after being scanned. Illustration 9 – Print Counter It is required that the user selects a field width unequal to 0 on the Counter Modes tab.
DpuScan Scamax 2600 / 5000 Scanner Options If you want this order changed, you will have to configure the counters by means of levels in events and actions. You can, for example, define that Counter C will be incremented in level zero and Counter B will be incremented in level one (new chapter).
Scanner Options Scamax 2600 / 5000 DpuScan 5.3.4 Level and Mode Output – "Print Flags" Tab The fourth tab allows the user to select how the Sequential ID, the level, the mode, and the flags should be printed.
DpuScan Scamax 2600 / 5000 Scanner Options Fixed Text In addition to numeric values such as counters or flags, the endorser can print text. Only the printout text is limited to the number of characters selected here. The text itself has to be entered in the field "Fixed Text Field", as seen below.
Scanner Options Scamax 2600 / 5000 DpuScan When using the %%I fieldcode and a longer lead or trail text in the endorser setup, the printout may be cut at the end. Hence, it is recommended that the user test the printout on any document before starting a "real” scan job.
DpuScan Scamax 2600 / 5000 Scanner Options Note: Using the normal endorser counter %U when the Patchcode Controlled Index is also in use is not recommended.
Scanner Options Scamax 2600 / 5000 DpuScan 5.4 Events and Actions Use this dialog to set the actions that will happen with which event. The following example defines that when a Patch II is found, the Chapter Counter is incremented and the Page Counter is reset.
DpuScan Scamax 2600 / 5000 Scanner Options Illustration 14 – Reset Values? 5.4.1 Events There are several groups of events: Patchcode Events These events happen when a certain Patchcode is recognized. Because the search is stopped after the first Patchcode found, only one such event can hap pen on any one page.
Scanner Options Scamax 2600 / 5000 DpuScan 5.4.2 Actions There are three groups of Actions: Actions that set counters These can reset and then increment the counters. This may influence the counter-based events or the increment of the automatic counter.
DpuScan Scamax 2600 / 5000 Scanner Options Step 2 Patchcode-Based Actions If the field width is equal to a value of anything but 0, the Counters A, B, C, and D will be reset and then incremented by the specified values. For details, see Chapter 5.2.3 Counters on Page 19 .
Scanner Options Scamax 2600 / 5000 DpuScan Step 7 Hardware Control After performing the counter and flag handling, the summary of the hardware actions take effect. Unless Drop Page is enabled, the page and the last heade r will be sent to the host. If necessary, the scanner stops now.
DpuScan Scamax 2600 / 5000 Scanner Options 5.5 Defining the Rule When defining a rule, the user must first determine the event and then which action shall result when the event happens. 5.5.1 Counter Handling Illustration 14 – Reset Values? on Page 34 shows the tab f or counter handling.
Scanner Options Scamax 2600 / 5000 DpuScan 5.5.2 Setting Flags And Level Illustration 15 – Setting Flags and Level Set momentary Flag Check this box to set the momentary flag in the header at Byte 155.
DpuScan Scamax 2600 / 5000 Scanner Options Set Level for the next document Setting the level causes all rules dependent on the level to be ignored for this sheet. Therefore, the new level takes effect for next sheet. Set Mode (Output only) Setting the mode number works only for the printout or the header.
Scanner Options Scamax 2600 / 5000 DpuScan 5.5.3 Device Control Illustration 16 – Device Control Stop Scanning This stops the scanner before the next sheet.
DpuScan Scamax 2600 / 5000 Scanner Options Page 42 of 42 W e c a p t u r e t h e f u t u r e W W e e c c a a p p t t u u r r e e t t h h e e f f u u t t u u r r e e J&K Imaging, L.
Een belangrijk punt na aankoop van elk apparaat ABL electronic Scamax 2600 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen ABL electronic Scamax 2600 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens ABL electronic Scamax 2600 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding ABL electronic Scamax 2600 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over ABL electronic Scamax 2600 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van ABL electronic Scamax 2600 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de ABL electronic Scamax 2600 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met ABL electronic Scamax 2600 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.