Gebruiksaanwijzing /service van het product DCM100 van de fabrikant Maretron
Ga naar pagina of 24
Revision 1.0 Page i ® ® DCM100 DC Monitor User’s Manual Revision 1.0 Copyright © 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021-7850 http://www.
DCM100 User’s Manual Page ii Revision 1.0 Revision History Revision Description 1.0 Original document.
Revision 1.0 Page iii ® ® Table of Contents 1 Introduc tion .................................................................................................................. ......... 1 1.1 Firmware Revi sion ...........................
DCM100 User’s Manual Page iv Revision 1.0 4.3 Battery C apacity ..................................................................................................... 10 4.4 Battery Ty pes .................................................
Revision 1.0 Page 1 ® ® 1 Introduction Congratulations on your purchase of the Ma retron DC Monitor (DCM100). Maretron has designed and built your DC monitor to the highest st andards for years of dependable and accurate service.
DCM100 User’s Manual Page 2 Revision 1.0 2 Installation 2.1 Unpacking the Box When unpacking the box contai ning the Maretron DCM100, y ou should find the followin g items: 1 – DCM100 – DC Monitor 1 – DC Current Sensor with 5 ft. long cable (Part # LEMHTA200-S) (outer cable covering grey) 1 – Battery Temperature Sensor with 5 ft.
Revision 1.0 Page 3 ® ® 2.3 Mounting the DCM100 Attach the DCM100 securely to the vessel using the included stainless steel mounting screws or other fasteners as shown in Figure 1 below . Figure 1 – Mounting the DCM100 2.4 Connecting the DCM100 The DCM100 requires two electrical connec tions as shown in .
DCM100 User’s Manual Figure 2 – NMEA 2000 ® Connector Face Views 2.4.2 Connecting the DC power and Sensor Connections The DCM100’s DC Power and sens or connections are made by connecting to the 12-pin terminal strip on the top of the uni t. First, remove the four screw s at the corners of the unit securing the splash guard to the unit.
Revision 1.0 Page 5 ® ® e. Disconnect the wire from the positive termina l of the battery or other DC source that is being monitored and place it through the hol e in the Current Sens or such that the arrow on the Current Sensor points towards the battery or DC source.
DCM100 User’s Manual Page 6 Revision 1.0 Period, 17) Zero Current Threshold, 18) Manual ly Set Battery to 100%, 19) Current Sensor Zero Offset Calibration, and 20) NMEA 2000 PGN Enable/Disable. 2.5.1 Instance Selection NMEA 2000 ® provides a unique engine instance for ea ch DC power source on a vess el.
Revision 1.0 Page 7 ® ® 2.5.4.3 Equalization You may indicate here whether or not the battery supports equalization. This is used only for reporting over the NMEA 2000 network. Ava ilable choices are “Supported” and “Not Supported”. 2.5.4.4 Temperature Coefficient The capacity of a battery generally increases with increasing temperat ure.
DCM100 User’s Manual Page 8 Revision 1.0 available, you can set this par ameter to the estimated battery temperature, between -25°C and 125°C. 2.5.4.11 Time Remaining Floor The DCM100 calculates the time , given the current being dischar ged from the battery, before the battery becomes discharged.
Revision 1.0 Page 9 ® ® 3.1 Parameters Common to DC Sources and Batteries The parameters in this section are transmitt ed regardless of the “ DC Type” selected (see Section 2.5.3 for details). 3.1.1 Battery Voltage This parameter indicates the voltage pr esent across the battery terminals.
DCM100 User’s Manual Page 10 Revision 1.0 4 Background 4.1 Why Monitor Batteries? The lifetime and storage capacity of batteries can be greatly affected by the way in which they are used. Discharging a battery excessively or under-charging or over-charging a battery can ruin it.
Revision 1.0 Page 11 ® ® 4.5 Battery Safety Precautions 1. Lead-acid batteries generate explosive gases during operation. Make sure that the area around the batteries is well-ventilated. Ne ver allow flames or sparks near a battery. 2. Wear clothing and eye protec tion when working with batteries.
DCM100 User’s Manual Page 12 Revision 1.0 restated version of the equation, wh ich allows you to calculate t he time to totally discharge a given battery at a given discharge current, follows: ܶൌ.
Revision 1.0 Page 13 ® ® • Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or markings or may corr ode the DCM100 enclosure or seals. • Ensure that the unit is mounted securely an d cannot be moved relative to the mounting surface.
DCM100 User’s Manual Page 14 Revision 1.0 automatically void the warranty. If service is required, please re turn the unit to an authorized Maretron service location. 8 Technical Specifications As Maretron is constantly impr oving its products, all specificat ions are subject to change without notice.
Revision 1.0 Page 15 ® ® Environmental Parameter Value IEC 60954 Classification Exposed Degree of Protection IP64 Operating Temperature -25°C to 55°C Storage Temperature -40°C to 70°C Relative Humidity 93%RH @40° per IEC60945-8.2 Vibration 2-13.
DCM100 User’s Manual 10 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 3 – Mounting Surface Template Page 16 Revision 1.
Revision 1.0 Page 17 ® ® 11 Maretron (2 Year) Limited Warranty Maretron warrants the DCM100 to be free from defects in material s and workmanship for t wo (2) years from the date of original purchase.
.
Revision 1.0 Appendix A – NMEA 2000 Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing DCM100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 127506 – DC Detailed Status The DCM100 uses this PGN to transmi t slowly changing DC and Battery Data Field 1: SID – The sequence identifier field is used to tie related PGNs together.
DCM100 User’s Manual Page A2 Appendix A – NMEA 2000 Interfacing Revision 1.0 PGN 127508 – Battery C onfiguration Status The DCM100 uses this PGN to transmi t unchanging battery configuration data. Field 1: Battery Instance – T his field indica tes the particular battery for which this data applies.
Een belangrijk punt na aankoop van elk apparaat Maretron DCM100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Maretron DCM100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Maretron DCM100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Maretron DCM100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Maretron DCM100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Maretron DCM100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Maretron DCM100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Maretron DCM100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.