1 I NTRODUCTION M ANUAL S COPE This guide provides an overvie w of the scanner and scanner oper ation with detailed i nformation about setup and installation. Adobe ® Acrobat ® versions of the user's manuals are also ava ilable for download from the Metrologic website (www.
2 I NTRODUCTION M ODEL N UMBER D ESIGNATION M ODEL N UMBER D ESIGNATION Figure 1. Model Number Designation B ASE K IT C OMPONENTS AND O PTIONAL A CCESSORIES B AS E K IT Part # Description MS2122* Stratos E Scanner * See model number designation ab ove for detailed information on interfa ce type and window type.
3 I NTRODUCTION B ASE K IT C OMPONENTS AND O PTIONAL A CCESSORIES O PTIONAL A CCESSORIES Part # Description AC to DC Power Transformer - Regulated +5V @ 1.
4 I NTRODUCTION G ENERAL P RECAUTIONS The following are some gener al precautions to remember when handling your MS2122 scanner. D O N OT T URN the unit upside down with the platter in place. D O N OT P RESS on the window in the replace ment platter or the vertical window frame.
5 I NTRODUCTION MS2122 D ESIGN S PECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <2.2 mW Horizontal Depth of Field: 0 mm - 152 mm (0”- 6”) for 0.33 m m (13 mil) bar code Vertical Depth of Field: 0 mm - 216 mm (0”- 8.
6 B ASE M ODEL C HARACTERISTICS MS2122 Scanner Components Figure 6. MS2122 Components I TEM N O . D ESCRIPTION 1 Blue and White LED Bar 2 Volume/Tone Button (Multi-Functio n) 3 Diamonex or Sapphire H .
7 B ASE M ODEL C HARACTERISTICS MS2122 Scanner Dimensions Figure 7. MS2122 Connectors Connector Panel Figure 8. MS2122 Connectors.
8 B ASE M ODEL C HARACTERISTICS MS2122 Scanner Caution and Serial Number Labels Figure 9. MS2122 Label Locations (Top) a nd Examples (Bottom) Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (S afety E xtra L ow V oltage) according to EN/IEC 60950-1.
9 I NSTALLATION Q UICK I NSTALLATION O UT LINE The following is a quick previ ew of the steps required for 1 st time installations. Each item is discussed in detail later in th is section. • Determine clearance, ventilation and service access requirements.
10 I NSTALLATION U NPACKING THE U NIT 1. Make sure the shipping box is top-side up before openi ng. 2. Remove the accessories box and check its content for the following items. • Product Manuals • Power Supply • Communication Cable(s) 3. Lift the scanner out of t he shipping box by gripping the bottom of the unit on both sides.
11 I NSTALLATION I NSTALLING THE U NIT IN THE C OUNTER There are two options for mounting your MS2122 scanner. Option A, is a two-point mounting s ystem that supports the unit at the front and back. Option B , is a three-point mounting system that s uppor ts the unit at the back and on the sides.
12 I NSTALLATION I NSTALLING THE U NIT IN THE C OUNTER Option B: Three-Point Support Figure 17. Option B, Three-Point Support.
13 I NSTALLATION I NTERFACE RS232 The following steps describe ho w to properly install the cables for an RS232 Stratos E application. T he scanner must then be configured to match the host’s RS 23 2 parameters. Cable installation al on e does not guarantee that the Stratos E will communicate properl y with the host system.
14 I NSTALLATION I NTERFACE F ULL S PEED USB (I NTEGRATED ) The following steps describe ho w to properly install the cables for a Full Speed Stratos E applicati on.
15 I NSTALLATION I NTERFACE IBM 46 XX The following steps describe ho w to properly install the cables for an IBM 46xx Stratos E application. T he scanner must then be configured to match the host’s IBM 46 xx par ameters. Cable installation al one does not gu arant ee that the Stratos E will communicate properl y with the host system.
16 I NSTALLATION I NTERFACE OCIA The following steps describe ho w to properly install the cables for an OCIA Stratos E application. The scanner must then be configured to match the host’s OC IA parameters. Cable insta llation al one does not guarantee that the Stratos E will communicate properl y with the host system.
17 I NSTALLATION S ECONDARY M ETROLOGIC S CANNER , C ABLE I NSTALLATION The following steps describe ho w to properly install the cables bet ween a secondary Metrologic scanner and the Stratos E . The Stratos E and the secondary scanner must then be configur ed to communicate properly.
18 I NSTALLATION EAS D EACTIVATION SW1 and SW2 are the switch banks insid e the Checkpoint device t hat set the deactivation range. T he following is a list of Checkpoint recommended s witch bank settings.
19 S CANNER O PERATION S CAN Z ONE Figure 25. Checker-Side (13 mil) Figure 26. Horizontal Left / Right (13 mil) Specifications are subjec t to change without notice.
20 S CANNER O PERATION S CAN Z ONE Figure 27. Horizontal Direct (13 mil) Figure 28. Vertical Direct (13 mil) Specifications are subjec t to change without notice.
21 S CANNER O PERATION S CAN Z ONE Figure 29. Top-Down (13 mil) IR A CTIVATION A REA The Stratos E ’s default po wer save mode † is Dual Action Power Save Mode #2 (see page 26) . This power save mode † turns the laser OFF after a configured p eriod of non-use then turns the motor OFF after thirty-minute intervals.
22 Figure 31. LED Bar S CANNER O PERATION I NDICATOR D ESCRIPTIONS Audible When in operation the Stratos E provides audible feedback that indicates th e status of the unit and the current scan. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no ton e) plus three volume settings.
23 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Visual Steady Blue When all lasers are active, the blue LED is il luminated. The bl ue LED will remain illuminated until al l lasers are deactivated . Steady Blue and Single White Flash When the scanner successfully reads a bar c ode, the white LED will flash and the scann er will beep once.
24 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code displ ay located under the pla tter near the bottom right corner of the output window (see figure below). Figure 32. Diagnostic Indicator Display The following is a list of possible err or codes and their meanings .
25 S CANNER O PERATION I NDICATOR D ESCRIPTIONS Diagnostic Indicator Display Error Code Description 21 LASER #1 (VERTICAL) ERROR – The laser in the vertical scanning subsystem denotes a failure. The scanner will try three times to correct the laser operation.
26 S CANNER O PERATION P OWER S AVE M ODES The MS2122 has five configurabl e power save modes. Refer to the MetroSelect Configuration Guide ( MLPN 00-0240 7 x ) for additional information on Po wer Save Modes. 1. Blink Power Sav e Mode: Blinks the laser OFF & ON after a configured perio d of non-use.
27 S CANNER O PERATION B EEPER O PTIONS AND B UTTON F UNCTIONS Changing the Beeper To ne Beeper tones may be configured directl y or incrementally using the follo wing bar code. The new tone will be heard fo llowed by a short pause. Two more new tones will be heard signifying the ne w setting has been stored in memory.
28 S CANNER O PERATION S TAR TUP When the scanner first receives po wer the white LED will flash, the bl ue LED will turn on and the scanner will beep once ( the white LED will remain o n for the duration of the beep ). The scanner is no w ready to scan.
29 M AINTENANCE D AILY M AINTENANCE Smudges and dirt can interfere with the prop er scanning of a bar code. Therefore, the output window will need occasional cleaning. For the glass window: 1. Spray glass cleaner onto lint free, non-abrasi ve cleaning cloth.
30 M AINTENANCE V ERTICAL S CAN W INDOW R EPLACE MENT Figure 38. Vertical Scan Window Replacement.
31 T ROUBLESHOOTING The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-MET RO or 1-800-436-3876 to preserve the limit ed warranty terms. Symptom Possible Cause(s) Solution All Interfaces No LEDs, beep or motor spin.
32 T ROUBLESHOOTING Symptom Possible Cause(s) Solution All Interfaces The bar code may have been printed incorrectly. Check if it is a check digit, character or border problem. The scanner is not configured correctly for this type of bar code. Check if check digits are set properly.
33 T ROUBLESHOOTING RS232 D EMONSTRATION P ROGRAM If an RS232 scanner is not communicating with your IBM compatib le PC, key in the following BASIC program to test that the communication port and scann er are working. This program is for demonstration purposes only.
34 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS Many functions of the scanner can be "config ured" - that is, enabl ed or disabled. The scanner is shippe d from the factory pre- configured to a set of default conditions. The default p arameter of the scanner has an asterisk ( * ) in the charts on the following pages.
35 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA RS232 IBM 46 XX USB Expanded ID “]e0” * 9 9 9 9 RSS Limited Enable 9 9 9 9 RSS Limited ID “]e0” * 9 9 9 9 RSS Limited .
36 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA RS232 IBM 46 XX USB Number of Scan Buffers 1 9 9 9 9 UPC GTIN-14 Format 9 9 9 9 EAN-8 Enable * 9 9 9 9 Transmit EAN-8 Check Di.
37 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA RS232 IBM 46 XX USB Enable Code 11 Check Digit 9 9 9 9 Parity Space 9 Baud Rate 9600 9 8 Data Bits 9 7 Data Bits * 9 Stop Bits.
38 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA RS232 IBM 46 XX USB Carriage Return Suffix * 9 9 Line Feed Suffix * 9 9 UPC Suffix 9 9 Transmit LRC 9 9 Start LRC on 1 st Byte.
39 D EFAULT S ETTINGS C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT OCIA RS232 IBM 46 XX USB German 434/439 Supplements 9 9 9 9 Convert Bookland to ISBN 9 9 9 9 Bookland 979 Supplements 9 9 9 9 Conve.
40 S CANNER AND C ABLE T ERMINATIONS S CANNER P INOUT C ONNECTIONS The MS2122 scanner interfaces terminate to 10-pin modular jacks lo cated on the bottom of the units.
41 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS Cable Connector Configurat ions RS232 Interface Cable, MLPN 57-5700 0 x -N-3 Pin Function 1 Signal Ground 2 RS232 Transmit Output.
42 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS Cable Connector Configurat ions Aux Port Configuration Cabl e*, MLPN 57-57008 x -N-3 Pin Function ** 1 No Connect 2 Output from t.
43 R EGULATORY C OMPLIAN CE S AFETY ITE Equipment IEC 60950-1; EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+ A1+A2, E N: 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performa nce of procedures other than those specif i ed herein may result in hazard ous laser light exposure.
44 R EGULATORY C OMPLIAN CE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices The following is applicable wh e n the scanner cable is g reater in length than 3 meters (9 .8 feet) when fully extended: Les instructions ci-dessous s’ap pliquent aux cables de sca nner dép assant 3 métres (9.
45 R EGULATORY C OMPLIAN CE EMC Class B Devices The following is applicable w hen the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’ap pliquent aux cables de scan ner ne dépassant pas 3 métres (9.
46 L IMITED W ARRANTY The MS2122 Stratos E ™ Serie s scanners are manufactured by Metrologic at its Suzhou, Chin a facility. The MS2122 Stratos E Series scanners have a three (3) year limited warranty from the date of manufacture.
47 P ATENTS Patent Information For patent information, please refer to www.honeywellaidc.com/patents ..
48.
49 I NDEX A AC ...................................................................... see power accessori es ..................................................................... 12 aperture ............................................................
50 I NDEX S safety......................................................................... 47, 48 scan zone .................................................................. 21–23 scanner pinouts ...................................................
.
March 2008 00 - 02028 C.
Een belangrijk punt na aankoop van elk apparaat Metrologic Instruments MS2122 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Metrologic Instruments MS2122 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Metrologic Instruments MS2122 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Metrologic Instruments MS2122 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Metrologic Instruments MS2122 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Metrologic Instruments MS2122 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Metrologic Instruments MS2122 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Metrologic Instruments MS2122 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.