Gebruiksaanwijzing /service van het product IS3480-00 van de fabrikant Metrologic
Ga naar pagina of 56
.
.
ii L OCATION S C ORPORATE H EADQUARTERS N ORTH A MERIC A E UROPEAN , M IDDLE E AST & A FRICAN H EADQUARTERS USA, N EW J ERSEY G ERM ANY , M UNICH Metrol ogic Instrum ents, Inc. Metrol ogic Instrum ents GmbH Tel: 1- 800-ID -METR O Fa x: 856 -228-66 73 Tel: 49 -89-890 19-0 Fa x: 49-8 9-8901 9-200 Email: i nfo@metr ologic.
iii T ABLE OF C ONTENTS Introduction Product Overv iew ............................................................................................. 1 Scanner and Ac cessori es...........................................................................
1 I NTRODUCTION Quantum ™ E is a miniature, o mni-directional scanning engine with optional singl e- line scann ing capabi lity. The self-contained d evice is ful ly enclosed eliminatin g the need for an external w indow or custo m enclosure. It is design ed for use in OEM equipm ent such a s price lookup system s and kiosks.
2 I NTRODUCTION Scanner and A ccessories B ASIC K IT C OMPONENTS Part No. Descripti on IS3480 Quantum™ E Sca nner 00-02026 IS3480 Install ation and Us er’s Guide * 00-02407 M etroSelect ® Configurati on Guide * 00-02090 IS3480 Supp lemental Conf iguration Guid e * * Guides also available for download at www.
3 I NTRODUCTION Scanner and A ccessories O PTIONAL A CCESS ORIES Part No. Descripti on 54-54002x -3 Keyboard W edge Pow erLink cable 54-54020x -3 Stand Alone K eyboard PowerLink cable 54-54213x -N-3 U.
4 I NTRODUCTION Scanner Components Figure 1. Scanner Components I TEM N O . D ESCRIPTION n Utility Con nector Locat ed Under Rubber Se al The rubber seal protecting the utility c onnector sh ould only be remov ed if the u tility co nnector is to be used.
5 I NTRODUCTION Caution and Serial Number Labels Figure 2. Mounting Specifications Figure 3..
6 I NSTALLATION RS232, RS232 TTL or Light Pen 1. Turn off the ho st device. 2. Plug the male 10-pin RJ45 end of the Pow erLink cable into the 10-pin sock et on the IS34 80. 3. Connect th e 9-pin female e nd of the PowerLink c able to the hos t device.
7 I NSTALLATION IBM 46xx or O CIA 1. Turn off the ho st device. 2. Plug the male 10-pin RJ45 end of the MVC cable into t he 10-pin sock et on the IS34 80.
8 I NSTALLATION Keyboard Wedge 1. Turn off the ho st device. 2. Plug the male 10-pin RJ45 end of the PowerLin k cable into th e 10-pin socket on t he IS3480. 3. Disconne ct the keyboard from the host device. 4. Connect the “Y ” end of the PowerLink c able to the key board and the key board port on t he host PC.
9 I NSTALLATION Stand- A lone Keyboard Wedge 1. Turn off the ho st device. 2. Plug the male 10-pin RJ45 end of the Pow erLink cable into the 10-pin sock et on the IS34 80. 3. Connect the oth er end of the PowerLink c able to the key board port on the ho st device.
10 I NSTALLATION Full Speed or Low Speed USB (Integrated) 1. Turn off the ho st device. 2. Plug the male 10-pin RJ45 end of the USB PowerLin k cable into th e 10-pin sock et on the IS34 80. 3. Plug the other e nd of the US B interface ca ble into the host dev ic e’s USB po rt .
11 I NSTALLATION Notes for Low Speed USB (External wit h MX009) Metrologic’ s MX009 USB ca ble is a dev ice that conv erts serial R S232 formatte d data to either U SB Keyboard or U SB Point-of-Sale co mmunicati on protocol.
12 S CANNER O PERATION Configurable Primary and Secondary Scan Pattern Modes There are tw o configurabl e scan pattern modes availa ble with the IS 3480. • The primary scan pat tern mode i s the default s can pattern act ive when t he scanner start s.
13 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON C LICK M ODE W ITH C ODE G ATE E NABL ED For illustrati on purposes the unit’s pri mary scan pattern h as been .
14 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON C LICK M ODE W ITH C ODE G ATE D ISABL ED For illustrati on purposes the unit’s pri mary scan pattern h as been.
15 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON H OLD M ODE W ITH C ODE G ATE E NABLED For illustrati on purposes the unit’s pri mary scan pattern h as been s .
16 S CANNER O PERATION Configurable Button Functions S ECONDARY S CAN P ATTERN B UTTON H OLD M ODE W ITH C ODE G ATE D ISA BLED For illustrati on purposes the unit’s pri mary scan pattern h as been .
17 S CANNER O PERATION Sweet Spot Mode The sweet spot mode is used to d etermine w here the maximum read rate area or “sweet spot” is locat ed for a spe cific bar code ty pe. When activ ated this mo de provides v isual and a udible feedbac k indicat ing how the s canner is sca nning.
18 S CANNER O PERATION A udi ble Indicators When the IS 3480 is in opera tion, it ca n provide au dible feedbac k. These soun ds indicate the status of t he scanner. Eight settings are available for the tone o f the beep (normal, 6 alternate t ones and no ton e).
19 S CANNER O PERATION Visual Indicat ors There are four LED s located on the top of t he IS3480. W hen the s canner is on, the flashing or constant illumination of the LEDs in dicates the st atus of the current scan and the scanne r. No LEDs The LEDs w ill not be ill uminated if the scanner i s not receiving power from the host or tra nsformer.
20 S CANNER O PERATION Failure Mode Indicators Flashing Blue and O ne Razzberry Tone This ind icates that the scanner ha s experienced a laser su bsystem fail ure.
21 S CANNER O PERATION Depth of Field Specifications* Normal Scan Zone Specificatio ns are base d on a 0.33 m m (13 mil) bar code. Figure 9. Normal Depth of Field * All specifi cations are su bject to ch ange without n otice.
22 S CANNER O PERATION Depth of Field Specifications* Reduced Scan Zone Specificatio ns are base d on a 0.33 m m (13 mil) bar code. Figure 10. Reduced Depth of Field * All specifi cations are su bject to ch ange without n otice.
23 S CANNER O PERATION Depth of Field by Bar Code Element Width* Normal Scan Zone M INIMU M B AR C ODE E LEME NT W IDT H ABCD E F mm .13 .15 .19 . 25 .33 .66 mils 5.2 5.7 7.5 10 13 26 Figure 11. Normal Scan Zone by Bar Code Element Width * All specifi cations are su bject to ch ange without n otice.
24 S CANNER O PERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone M INIMU M B AR C ODE E LEME NT W IDT H ABCDE F mm . 1 3. 1 5. 1 9. 2 5. 3 3. 6 6 mils 5.2 5.7 7.5 10 13 26 Figure 12. Reduced Scan Zone by Bar Code Element Width * All specifi cations are su bject to ch ange without n otice.
25 S CANNER O PERATION IR A ctivati on Range* Normal Figure 13. Normal IR Activation Range Reduced Figure 14. Reduced IR Activation Range * All specifi cations are su bject to ch ange without n otice.
26 T ROUBLESHOOTING G UIDE The follow ing guide is for reference pur poses only. Co ntact a Metrolo gic representativ e at 1-800-ID-M ETRO or 1-800-436-387 6 to preserve th e limited warranty terms on page 45. Symptoms Possible Cau se(s) Solutio n All Interfaces The unit h as no LEDs, beeper or motor spin.
27 T ROUBLESHOOTING G UIDE Symptoms Possible Cau se(s) Solutio n All Interfaces The unit scans a bar code, bu t locks up after the first sc an ( the white LED stays on ). The scan ner is configure d to support some form of host handshakin g but is not receiving th e signal.
28 T ROUBLESHOOTING G UIDE Symptoms Possible Cau se(s) Solutio n All Interfaces During pow er up the unit beeps 3 t imes. There is a non-volatile RAM failure. Contact a M etrologic serv ice representativ e. During pow er up the unit razze s continuo usly.
29 T ROUBLESHOOTING G UIDE Symptoms Possible Cau se(s) Solutio n RS232 Onl y The host is receiving d ata but the data d oes not look corr ect. The scanner and host may not be configur ed for the same interface. Check that the scanner an d the host are conf igured for the same interface.
30 D ESIGN S PECIFICATIONS IS3480 Operational Light Source: V isible L aser D iode (VLD) @ 650 nm Laser Power: 1.1 mW Normal Depth of Field: 25 mm - 280 mm (1”- 11”) Reduced Depth of Field: 25 mm - 150 mm (1”- 6”) 0.33 mm (13 mil) bar code Omni Scan Scan Speed: 1650 scan lines per second No.
31 D ESIGN S PECIFICATIONS IS3480 Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 1.375 W Standby Power: 1.0 W Operating Current: 275 mA typical at 5VDC Standby Current: 200 mA typical at 5VDC DC Transformers: Class II; 5.
32 A PPLICATIONS AND P ROTOCOLS The mode l number on eac h scanner includes the scanner num ber and fact ory default com municatio ns protocol. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTO COL .
33 D EFAULT S ETTINGS - C OMMUNICATI ON P ARAMETERS Many functions of the scanner ca n be "programme d" - that is e nabled or disabled. T he scanner is shipped fro m the factory pro grammed to a set of default cond itions. T he default para meter of the sc anner has a n asterisk ( * ) in the charts on the follow ing pages.
34 D EFAULT S ETTINGS - C OMMUNICATI ON P ARAMETERS P ARAMETER D EFAUL T OCIA USB RS2 32* OR RS232 TTL L IGHT P EN IBM 46XX KB W L ASER E MULATION Expande d ID “]e0” * 9 9 9 9 9 9 9 RSS Lim ited E.
35 D EFAULT S ETTINGS - C OMMUNICATI ON P ARAMETERS P ARAMETER D EFAUL T OCIA USB RS2 32* OR RS232 TTL L IGHT P EN IBM 46XX KB W L ASER E MULATION Transmit UP C-A Check Digit * 9 9 9 9 9 9 9 Transmit .
36 D EFAULT S ETTINGS - C OMMUNICATI ON P ARAMETERS P ARAMETER D EFAUL T OCIA USB RS2 32* OR RS232 TTL L IGHT P EN IBM 46XX KB W L ASER E MULATION Nixdorf ID 9 9 9 LRC En abled 9 9 9 UPC Prefix 9 9 9 .
37 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAUL T OCIA USB RS2 32* OR RS232 TTL L IGHT P EN IBM 46XX KB W L ASER E MULATION Supplem ents a re not Require d * 9 9 9 9 9 9 9 Two Di.
38 U PGRADING THE F LASH ROM F IRM W ARE The MetroSet2 pr ogram is a functional co mponent of M etrologic’s n ew line of Flash- based scanners. T his program a llows the us er of a Metrologi c scanner to quickly up grade to a new or custom ver sion of firmw are.
39 S CANNER AND C ABLE T ERM INATIONS Scanner Pinout Connections IS3480- 102 RS2 32, TTL Pin Function 1 Ground 2 Transmit ( Full RS232) 3 Receive (F ull RS232) 4 RTS O utput (TTL RS232) 5 CTS Input (T.
40 S CANNER AND C ABLE T ERM INATIONS IS3480- 11 IBM 468X/469X IS3480- 9 OCIA Pin Function Pin Function 1 Ground 1 Ground 2 RS232 Trans mit Output 2 RS232 Trans mit Output 3 RS232 Receiv e Input 3 RS2.
41 S CANNER AND C ABLE T ERM INATIONS Cable Connector Configurations (Host End) “Standard” Pow erLink Cable 53-53xxx -3 coiled or 54-54xxx -3 straight Pin Function 1 Shield Gr ound 2 RS232 Trans m.
42 S CANNER AND C ABLE T ERM INATIONS Cab l e Connec t o r Conf i gur a t i on s ( H ost End) Keyboard W edge Pow erLink Cable 54-54002x-3 Pin Function 1 Keyboard Cl ock 2 Keyboard Dat a 3 No Conne ct.
43 L ASER AND P RODUCT S AFET Y Caution Use of controls or adjustm ents or performance of procedures other than those specified herein may result i n hazardous laser light exposure. Under no circumst ances should the custom er attempt t o servic e the las er scanner.
44 L ASER AND P RODUCT S AFET Y Notices This equipment has been tested and found to comply with limits for a Class A digital device, pursuant t o part 15 of the FCC Rules. These limits are designed to provide reasonable protect ion against harmful interferenc e w hen the equi pment is operated in a commercial environment.
45 L IMITED W ARRANTY The IS3480 Quantum ™ E scanners are manufactured by Metrologic at its B lackwood, New Jersey, U.S. A. facility. The IS3480 Quantum E scanners have a three (3) year limited warranty from t he date of manufacture.
46 P ATENTS Patent Infor mation This M ETROLOGIC product may be cov ered by one or more of the f ollowing U.S. Patents: U.S. Patent No.; 5,216,232; 5,260,553; 5,3 40,971; 5,42 4,525; 5,48 4,992; 5,525.
47 I NDEX A AC ....................................... 2, 6–10 Accessorie s ............................... 2, 3 Adapter .......................................... 8 Audible Indi cator............. 12, 18–20, 26–29, 38 B Bar Code ............. 18–20, 26–29, 30 Bar W idth.
48 I NDEX Manual............................... 2, 18, 32 Meteor ......................................... 38 MetroSet2 .................................... 38 Mode of O peration Button ...................................... 17 Primary ...............
N OTES.
.
.
May 2004 Printed in the U SA 00 - 02026A.
Een belangrijk punt na aankoop van elk apparaat Metrologic IS3480-00 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Metrologic IS3480-00 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Metrologic IS3480-00 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Metrologic IS3480-00 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Metrologic IS3480-00 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Metrologic IS3480-00 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Metrologic IS3480-00 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Metrologic IS3480-00 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.