Always “On” UPS Systems Inc. GES L-Series – Single Phase Input, Single Phase Output Uninterruptible Power Supply USER MANUAL Version 1.4 GES-801L, GES-102L, GES-152L, GES-202L, GES-302L Line Int.
Always “On” UPS Systems Inc..
Always “On” UPS Systems Inc. 3 SAVE THESE INSTRUCTIONS This manual contains important instructions for the GES-801L, GES-102L, GES-152L, GES-202L, GES-302L and should be followed during installation and maintenance of the UPS and batteries. The UPS contains voltages that are potentially h azardous.
Always “On” UPS Systems Inc. 4 TABLE OF CONTENTS INTRODUCTION ................................................................................................................... ..................... 5 SAFETY INSTRU CTIONS ........................
Always “On” UPS Systems Inc. 5 Introduction The L-Series is a Line Interactive UPS sy stem that includes the newest and latest technology enhancements. The Line Inte ractive technology with AVR function (on- line voltage boost-up & buck-down) allows fo r a wide input voltage range of 90 to 150VAC.
Always “On” UPS Systems Inc. 6 Safety Instructions The UPS has its own internal energy source (ba tteries), therefore the output receptacles may have electricity present even though the UPS is disconnected from the utility power.
Always “On” UPS Systems Inc. 7 Presentation Front Panel 1. POWER bar graph (BATTERY CHARGE/LINE VOLTAGE) This displays the present battery charge as a pe rcentage of battery capacity. It also displays the utility line voltage. 2. LOAD bar graph This displays the amount of power required by the load as a percentage.
Always “On” UPS Systems Inc. 8 Rear Panel 11. TELEPHONE/MODEM/ETHERNET SURGE PROTECTION Surge protection for telephone line, modem line, a nd 10BaseT line to m aintain a completely safe connection for INTERNET/INTRANET service. 12. EXTERNAL BATTERY PACK CONNECTOR (optional) Allows for extended runtime.
Always “On” UPS Systems Inc. 9 16. INPUT CIRCUIT BREAKER It trips when the connected loads exceed the pr otected receptacle's capacity. The center plungers of the circuit breakers extend when tripped. 17. SITE WIRING FAULT INDICATORS (RED LED) It illuminates when the UPS is connected to an improperly wired AC power outlet.
Always “On” UPS Systems Inc. 10 Installation Unpacking and Inspection Examine the packaging for damage. Inform the ca rrier imm ediately if and/or when damage is noticed. Retain the packaging for future use. Placement Install the UPS in a protected area with adequate airflow and free of excessive dust.
Always “On” UPS Systems Inc. 11 Connecting the Telephone/Modem/Ethernet Lines Connect a telephone line, modem line, or 10BaseT line into the telephone/modem/Ethernet surge protection sockets on the back of the UPS. Th e RJ-45/RJ-11 modular sockets accept standard single line telephone connections and 10BaseT conn ectors.
Always “On” UPS Systems Inc. 12 Operation Switching “On” the UPS With the UPS plugged in, press and hold the “ON/ TEST” button for at least 1 second to switch the UPS on.
Always “On” UPS Systems Inc. 13 Battery Charge Bar Graph This 5 LED display indicates the present charge of the UPS's batteries as a percentage of the total battery capacity.
Always “On” UPS Systems Inc. 14 Software Options UPSilon 2000 Software The UPSilon 2000 software utilizes standard RS -232 interface to perform monitoring functions, and provides an orderly shutdown of a computer sy stem in the event of power failure.
Always “On” UPS Systems Inc. 15 Computer Interface Port The computer interface port has the following characteristics: The communication port on the back of the UPS m ay be connected to a host com puter. This port allows the computer to monitor the status of th e UPS and control the operation of the UPS.
Always “On” UPS Systems Inc. 16 Battery Replacement Your batteries should run anywhere from 3-5 years before they need to be replaced. Please follow the instructions below for easy, trouble free, battery replacement. 1. Turn the UPS off (follow procedure previously mentioned) 2.
Always “On” UPS Systems Inc. 17 Troubleshooting Please follow the guidelines below for solutions to common problem s: Check UPS input plug and wiring. Check UPS input voltage. Please prepare the information as follows for service personnel: UPS model number and serial num ber Description of problem(s) in detail.
Always “On” UPS Systems Inc. 18 Storage Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged.
Always “On” UPS Systems Inc. 19 Battery Bank Installation Install up to 8 battery banks per L Series UPS following the instructions below. Caution: Make sure the UPS is shutdown and unplugged before connecting additional Battery Packs (refer to Switching the UPS “Off” section, page 11) 1.
Always “On” UPS Systems Inc. 20 Specifications Specification Comparison MODEL NO. GES-801L GES-102L GES-152L GES-202L GES-302L MAXIMUM CAPACITY 800VA / 560W 1kVA / 700W 1.
Always “On” UPS Systems Inc. 21 OUTPUT SHORT YES ABNORMAL VOLTAGE YES MODEM OR NETWORK SINGLE LINE (2 wire RJ11) / NETWORK (UTP, RJ45) COMPATIBLE JACKS I/O NOISE PROTECTION COMMON & NORMAL MOD.
Always “On” UPS Systems Inc. 22 CONTACT INFORMATION Additional Purchases or Upgrades Always “On” UPS Systems Inc. Bldg 1 – 150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext 451 Fax: (250) 491-9775 Email: sales@alwaysonups.
Een belangrijk punt na aankoop van elk apparaat MGE UPS Systems GES-102L (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen MGE UPS Systems GES-102L heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens MGE UPS Systems GES-102L vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding MGE UPS Systems GES-102L leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over MGE UPS Systems GES-102L krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van MGE UPS Systems GES-102L bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de MGE UPS Systems GES-102L kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met MGE UPS Systems GES-102L . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.