A MIDDLEBY COMP ANY Digital T emperature Controller (KIT P/N 36939) Installation, Programming and T roubleshooting Instructions Middleby Marshall Inc. • 1400 T oastmaster Drive • Elgin, IL 60120 • (847) 741-3300 • F AX (847) 741-4406 Middleby Corporation 24 Hour Service Hotline 1-800-238-8444 © 1997 Middleby Marshall Inc.
INST ALLA TION INSTRUCTIONS This manual provides instructions for conversion: from to Analog T emperature Controller (A), PN 28071-0012 (without high-limit and cool down function)................................ Analog T emperature Controller (A), PN 28071-0018 (with high-limit and cool down function).
Unpacking The Digital T emperature Controller was checked before leaving the factory . Inspect the shipping container carefully for evidence of improper handling during shipment. In case of damage, make an immediate claim to the parts distributor from whom the unit was purchased.
Installing the Digital Controller Step Procedure 1. Insert the Digital T emperature Controller into the same panel slot making sure the face of the controller is upright with the display on top and the push buttons on the bottom. 2.. Identify the two rectangular holes on top and bottom of the control case.
4 } 8 7 6 5 4 L2 L1 9 10 11 12 13 14 15 16 Connect To Connect To [13] [14] [15] [16] [1] [2] Remove From Remove From [5] [6] [L2] [L1] [G] 500 Not used on certain model gas and electric ovens.
5. Check to be sure the oven’s thermocouple is the latest version flange mount style verses the obsolete version. See Figure 4 below . The obsolete thermocouple is not compatible with the latest tem.
6 PS200 Gas Oven, 208-240V , 50/60Hz, 1 Ph, 3W ...............................................................Figure 5 PS200 Gas Oven, 200V , 50/60Hz,1 Ph, 2W (Export Only)................................................Figure 5 PS200 Gas Oven, 208V , 50/60Hz,1 Ph, 2W (Export Only).
7 Figure 7 - Wiring Diagram Showing Electrical Connections (Refer to T able 2) Figure 8 - Wiring Diagram Showing Electrical Connections (Refer to T able 2) Figure 9 - Wiring Diagram Showing Electrical.
Programming After the Digital T emperature Control has been properly installed and wired, it is ready to be programmed for either the standard on/off cycling gas solenoid/electric heating system, or the modulating gas valve system.
Digital Temperature Controller PN 36056 Service instructions Push the lock key and the service key together to reach SP LOK, then use the service key to step through the other functions listed below. Use the arrow keys to change the function settings.
SERVICE KEY: Service use only SET PT: Lit when controller is displaying set point temperature. UP and DOWN arrow keys: Used to change the set point. Press UNLOCK & SET POINT keys simultaneously to unlock set point, UP & DOWN keys will now function for 60 seconds.
Diagnostic Error Messages The controller runs background tests during normal operation. If a problem with the background tests occurs, an error message is shown (flashing) in the Display .
Een belangrijk punt na aankoop van elk apparaat Middleby Marshall KIT P/N 36939 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Middleby Marshall KIT P/N 36939 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Middleby Marshall KIT P/N 36939 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Middleby Marshall KIT P/N 36939 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Middleby Marshall KIT P/N 36939 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Middleby Marshall KIT P/N 36939 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Middleby Marshall KIT P/N 36939 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Middleby Marshall KIT P/N 36939 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.