Gebruiksaanwijzing /service van het product DA 6590 W van de fabrikant Miele
Ga naar pagina of 40
Operating and Installation Instructions Ventilation System DA 6590 W DA 6520 W To prevent accidents and appliance damage, read these instructions before installation or use.
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description of functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Guide to the ventilation system . . . .
READ AND SAVE THESE INSTRUCTIONS Keep these instructions in a safe place and pass them on to any future user. Read these instructions carefully before installing or using the Ventilation System. ~ This appliance is intended for residential use only. Use the appliance only for its intended purpose.
~ d) Before connecting the appliance to the power supply make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent appliance damage. If in doubt consult a qualified electrician.
, WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING * : ~ a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS . If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
Installation , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ~ a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
The ventilation system can be operated Air extraction The air is drawn in and cleaned by the grease filters and directed outside. The hood comes equipped with a non-return flap . This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur.
Guide to the ventilation system 8.
a Chimney extension b Chimney c Canopy d Control panel e Grease filter f Glass or stainless steel panels Optional accessories DRP 6590 W glass (3 elements) DRP 6590 W stainless steel (3 elements) g Re.
Turning the fan on K ^ Press the On/Off button K . The fan turns on at level 2 . The K symbol and power level 2 indicators light up. Selecting the power level ^ Use the " – / + " controls to select the desired power level.
Delayed shut down 5 ¢ 15 For both air extraction and recirculation, it is recommended that run the fan for several minutes after cooking is completed. This helps clear the kitchen air of any remaining vapors and odors. The Delayed Shut Down feature can be selected to turn the fan off automatically after a preselected length of time.
Automatic safety shut-off The fan will turn automatically off 10 hours of use. The lighting however will remain on. ^ Press the On/Off button K to turn the fan back on again.
Activating/changing the odor-free filter timer (in recirculation mode) The odor-free filter is necessary for recirculation mode. The odor-free filter timer is not pre-set . The timer may be set to suit your cooking habits. ^ Press the On/Off button K to turn the fan off ^ Press + and the filter button — at the same time.
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". , The halogen bulbs are very hot when in use.
Special instructions for glass surfaces ^ Glass surfaces should be cleaned with a normal glass cleaner. Stainless steel colored controls These controls may become dis - colored or damaged if not cleaned regularly. Do not use a stainless steel cleaner on these controls.
^ Open the grease filter lock, lower the grease filter slightly, unhook it at the back, and take it out. Support the grease filter so that it does not fall and damage the cooktop. Cleaning the panels by hand ^ Follow the instructions under "Cleaning the casing".
^ When reinstalling the grease filters, make sure that the locking clips are facing down. ^ If the filters are incorrectly installed, insert a small screwdriver into the slit along its edge to disengage them from the casing. ^ Hook the panels onto the support ledge.
Installing / replacing the odor-free filter In recirculation mode, an odor-free filter must be used in addition to the grease filters. It is designed to absorb cooking odors. It is installed in the canopy above the grease filters. Replacement active charcoal filters can be ordered from Miele.
Changing the light bulbs , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions". When in use halogen bulbs become extremely hot, and can burn your hands.
Repairs In the event of a fault which you cannot easily fix yourself, please contact the Miele Technical Service Department. ^ When contacting the Technical Service Department, please quote the model and serial number of your appliance. These are shown on the data plate which is visible when the grease filters are removed.
Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user.
22.
Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. , DANGER Ensure that any plastic wrappings, bags, etc., are disposed of safely and kept out of the reach of babies and young children.
Drawing is not to scale. Appliance dimensions 24.
a Air extraction mode b Recirculation mode c Recirculation vent positioned at the top (only for the DA 6590 W in recirculation mode) d , e Installation area; For recirculation mode only d . Wall/ceiling area respectively for vent hole and outlet installation.
Distance between cooktop and hood (S) Do not install this exhaust hood over cooktops burning solid fuel. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum .
Drilling diagram To prepare a backing plate, the spacings for the 5 mm screws need to be drilled as shown. If the ventilation hood will be mounted directly to the wall, follow the additional instructions given in the included "Installation diagram".
The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min.
Before installation read the information in the "Dimensions" and "Important Safety Instruction" chapters. Under certain conditions, there is a danger of poisonous fumes by when the ventilation system and a furnace drawing interior air run at the same time.
Installation material Installation 30.
a 3 protective shields to prevent scratches to the chimney during installation. b 1 vent collar for use with 6" (150 mm) exhaust ducting. c 1 vent pipe adapter for use with 5" (125 mm) exhaust ducting. d Telescopic retaining plate to secure the ventilation hood to the wall.
, WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only.
– If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.
Reducing Collar (optional accessory) If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed. It reduces the air flow to less than 400 CFM. Check local building codes for max.
, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations.
Total connected load * ........4 1 0W – Fan motor * ................3 5 0W – Overhead light ...........3x2 0W Voltage ................. 1 2 0VA C Frequency .................. 6 0H z Fuse rating ...................1 5A Length of the power cord ....
37.
38.
39.
Alteration rights reserved / 5012 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.
Een belangrijk punt na aankoop van elk apparaat Miele DA 6590 W (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Miele DA 6590 W heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Miele DA 6590 W vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Miele DA 6590 W leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Miele DA 6590 W krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Miele DA 6590 W bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Miele DA 6590 W kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Miele DA 6590 W . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.