KM 400 Electric Cooktop KM 402 / KM 403 Fryer KM 408-1 Contact Grill KM 410 / KM 411 Electric Barbecue
To prevent accidents and machine damage, read these instructions before installation or use.
M.-Nr. 05 060 863




The minimum distances given in these Installation Instructions must be observed in order to ensure safe operation. Failure to do so increases the risk of fire.
To prevent appliance damage, the cabinetry and venting hood should be installed first.
The countertop must be bonded with heat resistant (212 °F/100 °C) adhesive to prevent distortion.
The cooktops should only be installed in the illustrations, while maintaining the required safety distances shown. Do not install the cooktop between two tall cabinets, this is a fire hazard.
a = Minimum safety distances:
KM 400 = 2" (50 mm) KM 402 / 403= 2" (50 mm) KM 408-1 = 2" (50 mm) KM 410 / 411 =10" (250 mm)
Deep fryers must not be installed next to gas cooktops. Gas flames can ignite splattering oil. A distance of at least 12" (305 mm) should be maintained between these two appliances.
recommended · not recommended · not allowed

Cooktops should not be installed above a dishwasher, washer, dryer, freezer or refrigerator. The high temperatures radiated downwards from the cooktops could damage these appliances.
Safety distance above the appliances
This equipment has not been designed for maritime use or for use in mobile installations such as aircraft or recreational vehicles. However, under certain circumstances it may be possible for an installation in these applications. Please contact the nearest Miele Dealer or the Miele Technical Service Department with specific requirements.
As a general rule there must be a minimum safety distance of at least 30 inches (760 mm) between the top of the appliance and any cabinet above it, b. The minimum distance of combustible surfaces located above and to the side of the cooktop, c, is 18" (457 mm).
Make sure that the power cord to the cooktop does not come into contact with any mechanical parts once the cooktop has been installed.
If the cabinet manufacturer recommends a different distance, follow that manufacturer’s recommendation.
The minimum safety distance between the KM 410 / KM 411 and the bottom of a venting hood should be no less than 26" (650 mm).
If more than one appliance is installed beneath a hood and they have different minimum safety distances, the greater distance should be followed.
Keep this instruction book in a safe place and pass it on to any future owner.


bPlease allow an additional 3/4"
(18 mm) depth below the cooktop for clearance of the power cord.





Installing one or multiple appliances:
Cut out the countertop using the dimensions listed in the following table.
All Miele combisets have the same length and width. Make sure that there is enough room beneath the countertop to allow for the depth of the various appliances. When installing a KM 402 / KM 403 or KM 410 / KM 411 remember to allow clearance for the drain valve that will be located in the cabinet beneath the appliances.
The tolerance for each dimension is 1/16" (1 mm).
When installing more than one combiset cooktop, a support bar must be installed between the appliances. Install the support bars as shown on the following page before setting the appliances into the countertop.
The following safety distances must be maintained:
– Between the cooktop and rear wall:
2" (50 mm).
– Between the cooktop and side wall
or cabinet: KM 400 = 2" (50 mm) KM 402 / 403= 2" (50 mm) KM 408-1 = 2" (50 mm) KM 410 / 411 =10" (250 mm)
Refer to section "Important Safety Instructions" for further information.


cSlight gap between support bar and
countertop.
This illustration shows the layout for 3 combisets, their respective support bars, b, and the 14 spring clamps, a, required for correct installation.
If more than 3 combisets are being installed, add an additional 11 3/8" (288 mm) to the overall width of the cut out for each extra combiset, or use the table on the preceding page.
bSupport bars

Securing the spring clamps


Wood or Corian countertops
Wood or Corian countertops
^ Arrange the bars, b, as shown in the
^ Place the spring clamps, a, as
shown in the illustration.
^ Drill 1/16" (1.5 mm) pilot holes through
^ Drill two 1/16" (1.5 mm) pilot holes for
the brackets and secure them using the supplied screws.
each clamp and secure using the supplied screws.
^ Fill the gap, c, between the bars and
the countertop using the supplied silicon sealant.
For granite countertops, the spring clamps can be secured using double-sided construction adhesive. Do not allow the spring clamps to "float", they must be securely fastened.
For granite countertops, the support bars, b, can be secured using double-sided construction tape. Do not allow the bars to "float", they must be securely fastened. Fill the gap, c, between the bars and the countertop using the supplied silicon sealant.
The screws are not necessary for granite countertops.
The screws are not necessary for granite countertops.
illustration · Granite countertops · Granite countertops


Make sure the cooktops are aligned correctly before setting them into the countertop. Once the spring clamps are engaged, a special tool is required to release the cooktop from the clamps.
^ Guide the power cord through the cut
out and connect the appliance to the electrical supply.
^ Position the cooktop over the cut out.
With a hand on each side, above the clamps, a, press the cooktop down, locking it into the spring clamps. Make sure that the cooktop rim lies flat against the countertop on all sides.

The cooktop must not be permanently sealed into the countertop when installed. The sealing strip under the edge of the cooktop provides a sufficient seal for the countertop.
If the cooktop is sealed into position, the countertop or the appliance may be damaged if the cooktop needs to be removed for maintenance or service.

Power supply:
,WARNING: Disconnect the appliance from the main power supply before servicing. To reduce the risk of electric shock, make sure that the appliance is properly grounded after installation.
– 240 V, 60 Hz, 15 A fuse rating
– 208 V, 60 Hz, 15 A fuse rating
The oven is equipped with a power cord consisting of 3 leads. They must be connected to a dedicated line through the use of an approved junction box
To guarantee the electrical safety of this appliance; continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met. If there is any doubt, have the electrical system of the house checked by a qualified electrician. The manufacturer cannot be held responsible for damages caused by the lack, or inadequacy of an, effective grounding system.
For further information, see the wiring diagram provided with the appliance.
All electrical work should be performed by a qualified electrician in accordance with local codes and the:
- National Electrical code ANSI / NFPA No. 70-1481 for USA or - Canadian Electrical Code Part I (CSA Standard C 22.1) for Canada
Please leave these instructions with the consumer.
or






Alterations rights reserved / 0705 M.-Nr. 05 060 863 / 01