D-75S, D-75D Processes Description MIG (GMA W) W elding Flux Cored (FCA W ) Welding (Gas- And Self-Shielded) Wire Feeder OM-228 322A 2006 − 06 File: MIG (GMA W) V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dec_wire_6/05 Declaration of Conformity for European Community (CE) Products This information is provided for units with CE certification (see rating label on unit). NOTE Manufacturer : European Contact: Miller Electric Mg. Co. Mr . Danilo Fedolfi, 1635 W .
OM-228 322 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Y W arning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
OM-228 322 Page 2 Arc rays from the w elding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin.
OM-228 322 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-228 322 Page 4 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www .
OM-228 322 Pa ge 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION som _3/05 Y A vertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-228 322 Page 6 Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provo- quer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage.
OM-228 322 Pa ge 7 2-3 . Dangers s upplé mentaire s e n rela t i on a v ec l’installa tion, l e fonctionneme nt e t la maintenance Risque D’INCENDIE OU D’EXPLO- SION. D Ne pas placer l’appareil sur , au-dessus ou à proximité de surfaces inflammables.
OM-228 322 Page 8 2-5. Princi pales n ormes de sécu rité Safety in W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site In- ternet : www .
OM-228 322 Page 9 SECTION 3 − DEFINITIONS 1 1.1 1.2 1.3 3 3.1 3.2 3.3 4 4.1 + 2 2.1 2.2 + + 56 + 2.3 S-178 936 A. W arning! Watch Out! There are possible hazards as shown by the symbols. B. Drive rolls can injure fingers. C. W elding wire and drive parts are at welding voltage during operation − keep hands and metal objects clear .
OM-228 322 Page 10 3-2. WEEE Label Do not discard this product with general waste. Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collec- tion facility . Contact your local recycling office or your local distributor for further information.
OM-228 322 Page 1 1 SECTION 4 − INTRODUCTION 4-1. Specifications T ype of Input Power W elding Power Source T ype W elding Circuit Rating IP Rating Overall Dimensions Maximum Spool W eight Wire Feed.
OM-228 322 Page 12 5-2. Equipment Connection Diagrams 1 W elding Power Source 2 Contactor Control/Power Cord 3 Weld Cable 4 Weld Cable 5 W orkpiece 6 Welding Gun 7 Wire Feeder 8 Gas Hose 9 Gas Cylinder and Regulator (Customer Supplied) . Shielding gas pressure not to exceed 100 PSI (689 kPa).
OM-228 322 Page 13 5-3. Rear Panel Connections And Rotating Drive Assembly 804 557-B / 804 184-B 2 1 14-Pin Control Cable - 10 Ft (3.0 m) 2 Shielding Gas V alve Fittings Requires fitting with 5/8-18 right-hand threads. Connect customer-supplied gas hose.
OM-228 322 Page 14 5-4. 14-Pin Plug Information Pin* Pin Information A 24 volts ac with respect to socket G. A J K B Contact closure to A completes 24 volts ac contactor control circuit. A J B K I L G Circuit common for 24 volts ac circuit. C L N H D M G C +10 volts dc input from power source to wire feeder with respect to socket D.
OM-228 322 Page 15 5-8. Installing PD Continuous Wire Guides Ref. 804 188-B . PD Continuous Wire Guides: Should be used with .068/.072 in (1.8 mm) and smaller diameter wire for opti- mal performance. Should be used with PD drive rolls and cannot be used with non-PD (old-style) drive rolls.
OM-228 322 Page 16 5-9. Installing Non-PD (Old Style) Wire Guides Ref. 804 192-C Installing wire guides with non- PD (old-style) drive rolls . Non-PD (old-style) wire guides and drive rolls should be used with 5/64 in (2.0 mm) and larger diameter wire.
OM-228 322 Page 17 5-10. Installing Welding Gun 804 189-C 1 Power Clamp Knob 2 Gun Locking T ab 3 Power Pin Groove 4 Gun Connection End Installing gun with Accu-Mate connection Loosen power clamp knob to allow power pin of gun to clear the gun locking tab.
OM-228 322 Page 18 5-1 1. Installing W elding Wire And Adjusting Pressure Drive Setting Ref. 804 190-B T ools Needed: 1 Drive Roll Pressure Adjustment Lever 2 Notch In Lever (Indicates Pressure Settings) Pressure drive settings range from 1 to 8 with 8 being the maximum setting.
OM-228 322 Page 19 5-12. Motor Board DIP Switch Settings Position Settings And Results For DIP Switch S1 On PC1 And PC101 Remove wrapper . 1 DIP Switch S1 On Motor Board PC1 and PC101 S1-1 Run-In enable or disable. S1-2 Automatic Run-In versus Manual Adjustment Run-in Install wrapper when finished.
OM-228 322 Page 20 T ools Needed: 1/4 in 5-13. Display Board DIP Switch Settings 12 3 45 Or Meters/Minute Inches/Minute Digital Meter Functions 12 3 45 803 069 Remove wrapper . 1 DIP Switch S2 On Digital Meter Board PC60 Install wrapper when finished.
OM-228 322 Page 21 SECTION 6 − OPERA TION 6-1. Power Switch 1 Power Switch 1 Ref. 804 567-B 1 Left/Right Select Switch Pressing the Left/Right Select switch allows the operator to choose which side of the unit’ s con- trols will operate. 6-2. Left/Right Select Switch 1 Ref.
OM-228 322 Page 22 6-4. T rigger Hold Switch 1 T rigger Hold Switches T rigger hold allows the operator to weld without holding the gun trigger . • T o use the trigger hold function, place the trigger hold switch in the On position.
OM-228 322 Page 23 SECTION 7 − MAINTENANCE 7-1. Routine Maintenance Y Disconnect power before maintaining. n = Check ~ = Clean l = Replace Reference Every 3 Months Section 5-2, 5-3 l Unreadable Labe.
OM-228 322 Page 24 7-3. Diagnostics 803 063-A 1 LED3 On Right Side Motor Control Board PC1 2 LED3 On Left Side Motor Control Board PC101 3 LED3 On Dual Board PC70 2 1 3 Display On Optional Meter LED3 .
OM-228 322 Page 25 7-4. T roubleshooting Y Disconnect power before troubleshooting T rouble Remedy Wire feeds, shielding gas flows, but electrode wire is not energized. Check cable connections. Check cables for continuity , and repair or replace cables if necessary (see Section 5-3).
OM-228 322 Page 26 SECTION 8 − ELECTRICAL DIAGRAM Figure 8-1. Circuit Diagram.
OM-228 322 Page 27 204 716-B.
OM-228 322 Page 28 SECTION 9 − P ARTS LIST 804 569-B . Hardware is common and not available unless listed. 22 Fig.9-2 23 1 2 3 Fig. 9-3 18 17 16 21 20 15 10 11 12 11 5 8 9 10 7 6 14 9 13 19 4 Figure 9-1.
OM-228 322 Page 29 Description Part No. Item No. Figure 9-1. Main Assembly Quantity 1 159 647 Insulator , Motor Clamp 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 159 646 Clamp, Motor Base 2 .
OM-228 322 Page 30 803 049-C . Hardware is common and not available unless listed. 7 3 4 5 6 8 9 10 11 12 5 13 14 16 4 2 15 19 18 17 26 20 21 22 22 21 23 24 25 1 27 Figure 9-2. Control Box Quantity Description Part No. Dia. Mkgs. Item No. Model D-75S D-75D Figure 9-2.
OM-228 322 Page 31 Quantity Description Part No. Dia. Mkgs. Item No. Model D-75S D-75D Figure 9-2. Control Box (Continued) 18 R1, R101 073 562 Potentiometer , Cp Std Slot 1T 2. W 10K Linear D-74S 2 0 . . . . . . . . . . . . . . . . . . . . . . . 18 R1, 101, 70, 170 224 597 Potentiometer , Cermet Std Flat 3.
OM-228 322 Page 32 See T able 9-1 For Drive Roll & Wire Guide Kits . Hardware is common and not available unless listed. 804 186-B 1 22 21 2 20 3 4 5 6 7 8 9 10 20 2 21 13 11 12 14 15 16 18 19 23 17 Figure 9-3. Drive Assembly , Wire (Left Side Drive Assembly Shown) Item No.
OM-228 322 Page 33 . Hardware is common and not available unless listed. 804 191-B 1 3 4 5 6 7 2 Figure 9-4. Drive Assembly With Motor (Left Side Drive Assembly Shown) Item No. Diagram marking Part No. Description Quantity Model D-75S D-75D Figure 9-4.
OM-228 322 Page 34 Wire Size PD-V for Hard Wire (1 kit or 4 rolls & 1 guide required) PD-U for Aluminum (1 kit or 4 rolls & 1 guide required) Guides for Old Style Drive Rolls (1 each required) Standard Drive Rolls ( 4 required) Fraction Metric PD-V Kit Roll Guide Roll Inlet Intermediate Exit V Groove U Groove VK Groove UC Groove .
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2006 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2006 Miller Electric Mfg. Co. 2006 − 01 Miller Elect ric Mf g. Co. An Illinois T ool Wo rks Co mpany 1635 W es t Spencer St reet Applet on, WI 5 4914 USA International He adquarter.
Een belangrijk punt na aankoop van elk apparaat Miller Electric D-75D (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Miller Electric D-75D heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Miller Electric D-75D vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Miller Electric D-75D leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Miller Electric D-75D krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Miller Electric D-75D bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Miller Electric D-75D kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Miller Electric D-75D . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.