Gebruiksaanwijzing /service van het product AG-150A van de fabrikant Mitsubishi Electronics
Ga naar pagina of 41
A ir-conditioner Net work System Centralized Controller Model: AG-150A I n s t r u c t i o n B o o k (Web browser for Initial Settings) Contents 1 Introduc tion .........................................................................1 1-1 Convent ions Used i n This Ma nual .
1 1 Introduction A specia l f eatur e of Mits u bi s hi El ectr ic Corpor a tio n’s “ Centra li ze d Contr o l ler AG - 150 A” is that a PC c onn ec t ed to a LAN c an be us ed to m onitor th e operat ion cond ition of air cond ition ers, perf orm air c onditioner operati ons, and ma ke initia l settin gs.
2 2 Setting the Operating Env i ronment Given below is an expl anation of the PC settings and web bro wser setti ngs that are requir ed for using a web browser to m onitor air con ditioner u nits and perform operatio ns.
3 (4) In the [Intern et Prot ocol (T CP/IP) Properties ] dia log, cl ick [Us e the follo wing IP addres s] an d enter the IP addres s (f or exam ple, “192.168. 1.101”) that you want t o set in t he IP a ddress field. You norm ally set [2 55.255. 255.
4 2-2 Setting the Web Browser Perform the necess ary web br owser sett ings to en able the web brows er to co nnect to th e AG-150 A. Note: The settings and screen images used as examples in this manual are based on Internet Explorer 6.
5 2-2-3 C onnecting to the Int ernet using a proxy server ( Using an existing LA N) If the PC you use f or monit oring a ir cond itioners and perf orm ing operations is goi ng to acc ess the Intern et.
6 3 Performing Operations Given be low is an exp lanation of how to connec t to the AG- 150A and ho w to mak e various setti ngs for the AG-150 A. Note: If the AG-150A is restarted due to circumstance.
7 3-1-2 Encry pting the communication data and lo gin on the AG-150A AG-150 A can encr ypt com munic ation data us ing HT TPS (SS L). W hen connecting the AG-1 50A to the LAN that can b e acces sed b .
8 (4) If the s ecurity alert has not been d isabled, af ter enter ing the web ad dress and hitting t he Enter (Re turn) k ey, a securit y alert m ess age will a lert ask ing if you want to proc eed . T his is becaus e the AG -150A us es the self- authenticat ion s ystem.
9 4 Initial Settings 4-1 Setting t he Current D ate and Time Click [Initial Se ttings] in th e m enu, and [Date an d Tim e] screen wil l appear on the scr een. Enter the curren t date and tim e, and then pres s the [Sav e Settings] butto n to send t he current date and t ime to AG -150A.
10 4-2 Setting t he Basic Inf ormation a nd External Inp ut Functio ns Displa y the p age needed to perf orm the AG-1 50A bas ic setting b y click ing [Initi al Settings]- [Basic S y stem ] in the settin g m enu pan e. On this pag e, you perf orm the basic sett ing s uch as the AG- 150A un it nam e, net work setting an d M-NET setting.
11 4-2-2 M-NET S etting In M-NET Setting, set the AG-150 A M-NET address , whether or not a K-Contr ol unit is pres ent and which machines send th e prohib ited contro ller com m and. (1) Enter the AG-15 0A M-N ET addres s in the [ M-NET Address] f ield.
12 4-2-3-1 Settings for when the A G-150A is connect ed to a dedicat ed LAN (1) Enter the AG -150A I P a ddress i n the [I P Address ] f ield. If th e LAN wiring has b een newl y set u p, allocat e I P addresses to the AG-15 0A units i n a sequent ial orde r starting with [192.
13 4-2-3-2 Settings for when the A G-150A is connect ed to an existing LA N W hen connecting the AG-1 50A to an ex isting L AN, consult with the ne twork administrator who is res ponsible for the LA N before sett ing t he IP addres s, subn et mask , or gatewa y address.
14 (4) Se lecting [ON/OFF /Prohib it/Perm it (Pulse signa l)] m ak es it possibl e to use puls e sign als to ru n m ultiple units, st op multiple units, p rohibit loca l operation and perm it local oper ation. In this mode, it is possible t o freel y operate the r emote c ontrol exc ept during t he puls e signal input.
15 4-2-5 Set ting the Display Format Set the item s r elated to the screen dis pla y in the [Dis play Form at] field. (1) In the [Un it of T emper ature] section, s elect b etween [ ºC ] and [ºF] as the un it of tem perature. (2) In the [Date F ormat] section, s elect the displa y or der of y ear /month/da y .
16 4-3 Group Se tting Displa y the p age n ee ded t o r egister the grou p of air condit io ners or gen eral e qu ip m ent to be connec te d to th e AG-150A an d to set the gr oup nam e by click ing [Initia l Settings]-[G roups]. O n this page , you perf orm the bas ic setting s uch as the AG-150A unit name, ne twork setting and M-NET setting.
17 (3) T o register rem ote controll ers in a gro up, click on the [Rem ote Controll er Registrati on] fiel d to displ ay the [Selec t Unit Addr esses] screen, and c lick on the nu m bers cor res pondin g to t he units t o be registere d. The on es that are s elected will be sho wn with a yellow-gr een back ground.
18 4-4 Interlocked S etting To interloc k the op eratio n of LOSSNA Y with t he run/stop s tatus of the indoor units, c lick on [Initial Settings]- [Interloc ked LOSSNA Y] in the m enu to bring up the I nterlock ed LOSSNA Y screen, and e nter the interlock conditi ons.
19 4-5 Block Se tti ng By perf orm ing block s etting s, m ultiples of air con ditione r groups c an be collect ively m onitored or opera ted fr om the W eb or T G-2000A.
20 5 Functions 1 5-1 Error mail repor ts/E-mail comm unication Click on [Functions 1] – [ E-Mail] in th e m enu to open the [E-m ail] windo w and m ake necessar y settings to perform remote m onitoring via m ail, using error m ail report or the m aintenance tool.
21 5-1-2 Se tti ng the Mail Server Information Enter the m ail ser ver infor mation prov ided b y eit her the ISP or the LAN adm inistr ator. Either t he IP ad dress or the host name ( server name) c an be entered i n the m ail server field. Make nec essar y settings d epending o n the f unctions t o be used, using th e table below as a referenc e.
22 (4) T o e-mail an err or whe n an error oc curs on ge neral equipm ent connected to PLC for genera l equipment, click the PLC Co nnection button, which ap pears at the time of selection of "G eneral Equi pment", to s et the IP addr ess of PLC f or gener al equipm ent.
23 5-2 Energ y-Save Control a nd Peak Cut Control Click on [Functions 1] – [ Peak Cut] in the m enu to bring up th e peak c ut control scr een, and mak e necessar y peak c ut settings to use the energ y-save or peak cut c ontrol func tion. Click [Save Sett ings] to sen d setting data to the AG-150A.
24 5-2-1 When Demand Controller Method is used (1) T o use Demand Contro ller Meth od, bef ore using the PL C Soft ware for dem and input or E lectric Am ount Count Sof tware, c lick on the PLC i nitia lize butt on once to initia lize the inter nal m emor y .
25 5-2-3 When PI Controller M ethod is used (1) Selec t the PI c ontroller to whic h the wat t-hour m eter us ed for peak cut contro l is c onnected. Note: Only the watt-hour meters t hat have been regi st ered on the Measurem ent screen can be selected.
26 5-2-5 When From externa l system Method is used (1) W hen the en ergy-sa ve leve l is s et to 0 (It is alwa ys set to level 0 in an energ y-save c ontrol m ethod ), energ y-save contro l will not b.
27 5-2-7 Setting the Indoor Unit Control Method (All methods) Make the e nerg y-save contr ol settings for the out door units for eac h energ y-save le vel. The s ettings ar e m ade for each o perat ion b lock . If the oper atio n block s have no t been set up, refer to s ectio n 4-5 on how to set the operation bloc k s .
28 5-3 Settings f or measurement To m easure the t em perature or the am ount of e lectricit y, clic k the [Function 1]-[Measur ement] in the m enu, an d open the Me asurem ent screen. Settings for c ontrollers us ed for m easurem ent can be m ade. After the s ettings are made , click [Save S ettings] t o send sett ing dat a to AG-15 0A.
29 5-3-2 A djusting the measured temperature /humidity values W hen the adjustm ent of the m easured val ues is nece ssar y becaus e of the loc ation of the sens or, foll ow the procedures belo w.
30 5-3-5 Set ting the destinatio n to which an error mail i s sent To r eceive an e-m ail when the temper ature or the hum idity exc eeds a c ertai n value, m ak e the error m ail sending sett ings . (1) Select [Out-of -lim it alarm ] in Type of E-Ma il pulld own, and enter the Mail Su bj ec t and the E-Mail Addr es s.
31 5-3-6 Setting the destination to w hich temperature/humid trend data mail i s sent To s end temperatur e/humid tr end data b y m ail once a da y ( w hen the dat e changes), mak e the mail sen ding settings . The trend data is sent as a n attachm ent CSV file.
32 6 Functions 2 6-1 Limi ting the Set Tem perature Operati ng Range Click on [Functi on2]-[Set Tem perature Range Lim it] in the m enu to open the set t emper ature range lim it screen, and m ak e necessar y settings to limit the s et tem perature op erating r ange of the loc al rem ote controller.
33 6-2 Night Mo de Schedule Click on [Funct i on2]-[Ni ght Mode Schedule] in the m enu to open the n ight m ode schedu le sc reen an d mak e necessar y settings t o s witc h the outd oor un it oper at io n m ode to th e n ight m ode (lo w-n ois e oper at io n), an d s et the night m ode tim e interva l.
34 6- 3 Sy ste m-Ch ang eove r of Y se rie s Click on [Functio n2]-[Aut o-chang eover] in the m enu to open the a uto-cha ngeover screen an d m ake necess ary settings to switch th e operation m ode bet ween cool ing and heat ing autom aticall y of the indo or units c onnected to the sam e outdoor unit.
35 7 Functions 3 7-1 External Tem perature I nterlock To us e external tem perature int erlock , click [Function 3] on t he m enu, and then click [External T emperatur e Interlock ].
36 7-2 Night set back contr ol To us e Night setb ack control ( abbreviate d to se tback control b elow), c lick [Functions 3] on the m enu, and t hen click [Setback Control].
37 8 User Setting Click on [User s ettin gs] in t he m enu to open the us er s etti ng s cr een an d m ake nec ess ar y user settin gs to lim it availab le functions of a buil ding m anager and to c hange us er nam es and pass words of maintenanc e user an d building m anag er.
38 Table 7-1 Availa ble Func tion Lis t Function Content Date and ti me Current date and time se tting Basic sy stem *1 AG-150A network setting, external o utput setting Group name Group name setting .
39 9 Registering a License fo r Optional Function Given be low is an ex planation on h ow to re gister a lic ense f or optional f unctions . In the Logi n screen ( see3-1) , click [License r egistration f or optio nal functi ons] and the License Re gistrat ion of Option al Func tions s creen will appear.
W T05491X02 HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN.
Een belangrijk punt na aankoop van elk apparaat Mitsubishi Electronics AG-150A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Mitsubishi Electronics AG-150A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Mitsubishi Electronics AG-150A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Mitsubishi Electronics AG-150A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Mitsubishi Electronics AG-150A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Mitsubishi Electronics AG-150A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Mitsubishi Electronics AG-150A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Mitsubishi Electronics AG-150A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.