Air -Conditioner s PKA-A·F A PKA-A·F AL English INST ALLA TION MANU AL For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit.
2 s Before installing the unit, make sure you read all the “Safety precau- tions”. s Please report to your supply authority or obtain their consent bef ore connecting this equipment to the power suppl y system. W arning: Describes precautions that must be observed to prevent danger of injury or death to the user .
3 2. Installation location 3. Installing the indoor unit Fig. 2-1 3.1. Check the indoor unit accessories (Fig. 3-1) The indoor unit should be supplied with the follo wing accessor ies.
4 3. Installing the indoor unit 3) Installing the wall mounting fixture s Since the indoor unit weighs near 30 kg, 66 lbs, selection of the mounting location requires thorough consideration. If the wall does not seem to be strong enough, reinforce it with boards or beams bef ore installation.
5 3. Installing the indoor unit 4. Installing the refrigerant piping 3.4. Mounting the indoor unit (Fig. 3-11) 1 Make sure to hang the metal catches of the indoor unit o ver the hooks of the wall mounting fixture. 2 When the piping has been completed, use the securing screws to fix the indoor unit on the wall mounting fixture .
6 4.4. Insulating pipes (Fig. 4-5) Refer to the Fig. 4-5 for insulating. Liquid pipe Gas pipe Insulation material 3 Band (large) 4 Band (small) 4 Band (small) 4 Ta p e Thermal insulating material for refrigerant piping Thermal insulating material for liquid pipe Liquid pipe 13/16 inch O.
I nd oo r u ni t m o de l Minim u m c ir cu i t am p a c i ty Ma x im u m ra t ing of o ver cu rren t p r ot e ct ive devi c e I nd oo r u ni t-Out d oo r u ni t *1 I nd oo r u ni t ear th Rem ot e co.
8 6. Electrical work S1 S2 S3 L1 L2 GR BLUE BLUE YELLOW YELLOW CND CND ORANGE CND ORANGE S1 S2 S3 L1 L2 GR YELLOW BLUE BLUE YELLOW CND 6.1.2. Separate indoor unit/outdoor unit power supplies (A-contr ol application) The follo wing connection patterns are availab le.
11 A P air No. of wireless remote controller Indoor PC board 0 F actory setting 1 Cut J41 2 Cut J42 3–9 Cut J41, J42 4) Assigning a remote controller to each unit (Fig. 6-7) Each unit can be operated only b y the assigned remote controller . Make sure each pair of an indoor unit PC board and a remote controller is assigned to the same pair No .
12 6. Electrical w ork Function table Select unit number 00 Mode P ower f ailure automatic recov er y Indoor temperature detecting LOSSNA Y connectivity P ower v oltage Auto mode (only f or PUHZ) Sett.
13 7.2.3. Using SW4 in outdoor unit Refer to the outdoor unit installation man ual. 7.3. Self-chec k 7.3.1. Wired remote controller (Fig. 7-3) 1 T urn on the power . 2 Press the [CHECK] button twice . 3 Set refrigerant address with [TEMP] button if system control is used.
14 • If the unit cannot be operated properly after the abov e test run has been performed, refer to the f ollowing table to remo ve th e cause. Symptom Cause Wired remote controller LED 1, 2 (PCB in.
15 Maintenance mode operation procedures (1) Press the TEST button f or three seconds to activate the maintenance mode . (2) Press the TEMP . buttons to set the refrigerant address.
Please be sure to put the contact address/telephone number on this manual before handing it to the customer. This product is designed and intended for use in the residential, commercial and light-industrial environment.
Een belangrijk punt na aankoop van elk apparaat Mitsubishi Electronics PKA-AFAL (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Mitsubishi Electronics PKA-AFAL heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Mitsubishi Electronics PKA-AFAL vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Mitsubishi Electronics PKA-AFAL leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Mitsubishi Electronics PKA-AFAL krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Mitsubishi Electronics PKA-AFAL bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Mitsubishi Electronics PKA-AFAL kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Mitsubishi Electronics PKA-AFAL . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.