Inhoudsopgave 80 secties SPLIT-TYPE AIRCONDITIONERS · Nee. OBIT16 HERZIENE EDITIE-H · TECHNISCHE GIDS VOOR DE DIENST · INHOUD · … TonenVerbergen
SPLIT-TYPE AIRCONDITIONERSp.1Nee. OBIT16 HERZIENE EDITIE-Hp.1TECHNISCHE GIDS VOOR DE DIENSTp.1INHOUDp.1VERTROUWELIJK (ALLEEN VOOR INTERN GEBRUIK)p.11 MS MICROPROCESSORBESTURINGp.41-1. KOELE () WERKINGp.4-1.8°F -1.35°F (-1°C) (-0.75°C)p.45.4°F (3°C) 1.8°F (1°C)p.43.15°F (1.75°C)p.4AANp.4UITp.4-3.6°F -1.35°F (-2°C) (-0.75°C)p.54.5°F (2.5°C) 1.8°F (1°C)p.52 MSZ, MICROPROCESSORCONTROLE VAN HET SYSTEEMp.72-1. KOELE () WERKINGp.71.8°F (1°C)p.83.6°F (2°C)p.87.2°F (4°C)p.8MSZ-A09/12/15/17 MSZ-FD MSZ-FE MSZ-D MSZ-GEp.9(MSZ-FE18 MSZ-GE24)p.9Tijdkaart van ontdooiing in de WARMTE-modus (omgekeerd type)p.10<Indoor eenheid>p.10(39°C)p.10(18°C)p.10<Outdoor unit>p.10OFF OFFp.10ON ONp.10ON (HEAT)p.10(21S4) OFF (COOL)p.102-7. INVERTER SYSTEEM CONTROLE 2-7-1. Inverter hoofdvoedingscircuitp.12MUZ-A09/12/15/17 MUY-A15/17 MUZ-FD MUZ-FE09/12 MSZ-GE06/09/12/15/18 MUY-GE09/12/15/18p.12STROOMTRANSFORMATORp.12DIODEMODULE1p.12REACTORp.12GELUIDFILTERCIRCUITp.12WEERSTANDp.12VOEDINGp.12GLADMAKENDE CONDENSATORp.12MSp.123~ Vp.12RELAISp.12INTELLIGENTp.12COMPRESSORp.12POWERMODULEp.12SCHAKELSTROOMTRANSISTORp.12DIODEMODULE2p.12BOOSTER HELIKOPTER CIRCUITp.12INTELLIGENTE POWERMODULE-VERMOGENSFACTORp.13CORRECTIEp.13MODULEp.13NAAMFUNCTIEp.132-9. UITBREIDINGSKLEPREGELING (LEV-BESTURING)p.18F E D C B Ap.19COOL / HEAT ( MUZ ) °F/°Cp.1968°F (20°C)p.2069.8°F (21°C)p.203 MXZ MICROPROCESSORBESTURINGp.213-1. INVERTER SYSTEEMREGELINGp.21MXZ-2A20NA/3A30NAp.24LEVp.24(MXZ-3A30NA)p.24<MXZ-2A20NA>p.24<MXZ-3A30NA>p.24MXZ-2A20NAp.25MXZ-3A30NAp.25MXZ-2A20NA1 , 2 MXz-2B20NA MX Z-2B2Na1 Exclusieve LEVp.262 COOL -20 HEAT 30p.26MXZ-3A30NA1 MXZ-4A36NA MXZ-3B24NA MXZ-3B30NA MXZ-4B36NAp.26MXZ-2A20NA1 , 2 MXZ-2B20NA MXZ-2B20NA1p.27MXZ-2A MXZ-2Bp.28MXZ-3A MXZ-4A MXZ-3B MXZ-4Bp.283-3. OPERATIONEEL FREQUENTIEBEREIKp.29MXZ-2A20NA1p.29MXZ-2A20NA2p.29MXZ-2B20NAp.30MXZ-2B20NA1p.30MXZ-3A30NA1 MXZ-4A36NAp.30MXZ-3B24NA MXZ-3B30NA MXZ-4B36NAp.31MXZ-2B20NA1 MXZ-3B MXZ-4Bp.32
Page 1 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — VERTROUWELIJK (ALLEEN VOOR INTERN GEBRUIK)
Pagina 1 · klik om te vergroten
Pagina 1

Herziening H: • MXZ-3B24NA - 1, MXZ-3B30NA - 1 en MXZ- 4B36NA - 1 zijn toegevoegd.

SPLIT-TYPE AIRCONDITIONERS

Vernietig OBT16 HERZIENE EDITIE-G.

Nee. OBIT16 HERZIENE EDITIE-H

TECHNISCHE GIDS VOOR DE DIENST

  • Modellen MS-A
  • WA · MU-A
  • WA MSZ-A
  • NA · MUZ-A
  • NA, - U MSY-A
  • NA · MUY-A
  • NA MSZ-FD
  • NA · MUZ-FD
  • NA, - U MSZ-FE
  • NA · MUZ-FE
  • NA MSZ-D
  • NA · MUZ-D
  • NA, - U MSY-D
  • NA · MUY-D
  • NA MSZ-GA
  • NA · MUZ-GA
  • NA, - U MSY-GA
  • NA · MUY-GA
  • NA MSZ-GE
  • NA · MUZ-GE
  • NA MSY-GE
  • NA · MUY-GE
  • NA MFZ-KA
  • NA · MXZ-A
  • NA, - 1 , - 2 · MXZ-B
  • NA, - 1

INHOUD

1. MS MICROPROCESSOR CONTROL 4 2. MSZ, MSY MICROPROCESSOR CONTROL 7 3. MXZ MICROPROCESSORCONTROLE 21 4. MFZ MICROPROCESSORBESTURING 35

VERTROUWELIJK (ALLEEN VOOR INTERN GEBRUIK)

Page 2 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — SPLIT-TYPE AIRCONDITIONERS
Pagina 2 · klik om te vergroten
Pagina 2

Herziening A: • MXZ-3A30NA- 1 is toegevoegd.

Herziening B: • MXZ-2A20NA- 1 , MXZ-4A36NA, MSZ-FD, SD en Msy-D zijn toegevoegd.

Herziening C: • MXZ-2A20NA- 2 is toegevoegd.

  • Herziening D:
  • MSZ-GA
  • NA en Msy-GA
  • Er is een NA toegevoegd.
  • Herziening E:
  • MSZ-FE
  • NA, MSZ-GE
  • NA, MSY-GE
  • NA en MXZ-B
  • Er is een NA toegevoegd.

Herziening F: • MXZ-2B20NA- 1, MXZ-3B24NA, MxZ-3 B30NA, mxz-4B36NA en MFZ-KA09/12/18NA zijn toegevoegd.

Herziening G: • MSZ-FE18NA, MSz-GE24NA en Msy-Ge24NA zijn toegevoegd.

Herziening H: • MXZ-3B24NA - 1, MXZ-3B30NA - 1 en MXZ-4B36NA - 1 zijn toegevoegd.

Page 3 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 4. MFZ MICROCESSOR CONTROL 35 Binnenunit modellen MFZ-KA09NA MFz-KA12NA SFZ- KA18NA
Pagina 3 · klik om te vergroten
Pagina 3
1. MS MICROCESSOR CONTROL 4 Binnen-unit modellen Outdoor unit modellen MS-A09/12WA ME-A9/12WA 1-1. KOELE OPERATIE 4-1-2. DROGE WERKING 4 1-3. AUTOMATISCHE VAAN OPERATIE 6

2. MSZ, MSY MICROPROCESSOR CONTROL 7 Binnen-unit modellen Outdoor unit modellen MSZ-A09/12/15/17/24NA MUZ- A09/12/15/17/24NA MSY-A15/17-24NA MUY-A 15/17/24ANA MSZ-FD09/12NA MUZZ-FD09/12NA MSZW-FE09/12/18NA MUZI-FE 09/12/18 NA MSZY-D30/36NA MUJ-D 30/36NA MSY - D30/ 36NA MUI-D-30/36NÁ MSZE-GA24NA MUZIEK-GA 24NA MUID-GA-24NA MOY-GA 24,NA MSEZ-GE06/09/1/15/18224NA MUZ-GE09/12/150/184NA MSYN-GE009/12/15 18/2124NA 2-1. KOELE OPERATIE 7 2-2. DROGE WERKING 8 2-3. WARMTEBEHANDELING 8 2-4. AUTOMATISCHE VERANDERING OVER ··· AUTOMODUS-BEWERKING 10 2-5. OUTDOOR VENTILATOR MOTOR BEDIENING 11 2-6. AUTO VAAN OPERATIE 11 2-7. INVERTER SYSTEEM CONTROLE 12 2-8. OPERATIONELE FREQUENTIEREGELING VAN BUITENUNIT 17-29. UITBREIDINGSKLEPREGELING (LEV CONTROL) 18 2-10. VOORWARMTEREGELING 20

3. MXZ MICROPROCESSOR CONTROL 21 OUTDOOR UNIT MODELLEN MXZ-2A20NA MXS-3A30NA M XZ-4A36NA MXZ-2B20NA MXZ-3B24NA MXIZ-3 B30NAMXZ-4B36NA 3-1. OMVORMER SYSTEEM CONTROLE 21 3-2. UITBREIDINGSKLEPREGELING (LEV-BESTURING) 23 3-3. OPERATIONELE FREQUENTIEBEREIK 29 3-4. WARMTEONTDOOIINGSREGELING 31 3-5. TEMPERATUURBESCHERMINGSREGELING 31 3-6. OUTDOOR VENTILATORCONTROLE 32 3-7. VOORWARMTEREGELING 33 3-8. KOELE OPERATIE 33 3-9. DROGE WERKING 34 310 . WARMTEWERKING 34

4. MFZ MICROCESSOR CONTROL 35 Binnenunit modellen MFZ-KA09NA MFz-KA12NA SFZ- KA18NA

4-1. KOELE OPERATIE 35 4-2. DROGE WERKING 35 4-3. WARMTEBEHANDELING 36 4-4. AUTOMATISCHE VERANDERING OVER ··· AUTOMODUS OPERATIE 37 4-5. INDOOR VENTILATOR MOTOR CONTROL 37 4-6. AUTOMATISCHE VAAN OPERATIE 38

Page 4 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — AAN
Pagina 4 · klik om te vergroten
Pagina 4

1 MS MICROPROCESSORBESTURING

1-1. KOELE () WERKING

1. Thermostaatcontrole Thermostat wordt aan of uit gezet door het verschil tussen kamertemperatuur en ingestelde temperatuur.

Ruimtetemperatuur minus ingestelde temperatuur (Tijdens werking) Kamertemperatuur min ingestelde temperatuur

met een vermogen van meer dan 1 W doch niet meer dan 2 kW

-1.8°F -1.35°F (-1°C) (-0.75°C)

2. Indoor ventilator snelheidscontrole De binnenventilator werkt continu op de ingestelde snelheid door FAN SPEED CONTROL knop, ongeacht het type thermostaat OFFON. In AUTO is de ventilatorsnelheid als volgt.

Ruimtetemperatuur minus ingestelde temperatuur (begin)

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking)

Hoog 3,15 °F (1,75 °C) of meer Med. tussen 1,8 en 3,15 °F Laag minder dan 1,8°F(1°C)

5.4°F (3°C) 1.8°F (1°C)

3.15°F (1.75°C)

3. Voorkoming van vorsten Temperatuurregeling

Wanneer de binnenspoelthermistor RT12 37°F (3 °C) of onder het spoelkouspreventiesysteem staat, begint onmiddellijk. Echter, de spoel vorst preventie werkt niet gedurende 5 minuten sinds het starten van de compressor. De ventilator werkt op de ingestelde snelheid en de compressor stopt gedurende 5 minuten. Als de binnenspoelthermistor dan nog steeds beneden 37°F (3°C) staat, wordt deze modus verlengd tot het indoor spoelthermemechanisme meer dan 37° F (3° C) leest. Tijdregeling

Wanneer de 3 voorwaarden als volgt zijn voldaan voor 1 uur en 45 minuten, compressor stopt gedurende 3 minuten. a. De compressor werkt continu. b. De ventilatorsnelheid is laag of Med. c. De kamertemperatuur is minder dan 79°F (26 °C). Wanneer de compressor stopt, wordt de verzamelde tijd geannuleerd en wanneer de camper opnieuw start begint het aantal keren dat er een aanvang is gemaakt. De tijdtelling stopt ook tijdelijk wanneer de ventilatorsnelheid binnen hoog wordt of als de kamertemperatuur meer dan 79°F (26 °C) bedraagt. Wanneer echter twee van de bovenstaande voorwaarden (b. en c.) zijn weer tevreden, de tijd accumulatie wordt hervat.

AAN

UIT

(continu bij ingestelde snelheid) AAN

1-2. DROOG () BEDRIJF Stel temperatuur is zoals aangegeven op de juiste kaart. Het systeem voor droog bedrijf maakt gebruik van hetzelfde koelmiddelcircuit als het koelcircuit. De compressor en de ventilator binnen worden bestuurd door het kamertempo. Door dergelijke controles zal de hoeveelheid stroom binnen worden verminderd om luchtvochtigheid te verlagen zonder veel kamertemperatuurdaling.

Stel temperatuur en kamertemperatuur in droogstand

50(10) 50 59 68 77 86 95

(10) (15) (20) (25) (30) (35)

Begintemperatuur van de kamertemperatuur [°F(°C)]

Toon 10 meer labels / korte tekst op deze pagina
Ventilatorsnelheid · Voorbeeld van operatietabel · Compressor Outdoor ventilator · Binnenventilator · 95(35) · Stel temperatuur in [°F(°C)] · 86(30) · 77(25) · 68(20) · 59(15)
Page 5 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — AAN
Pagina 5 · klik om te vergroten
Pagina 5
1. Thermostaatcontrole Thermostat wordt aan of uit gezet door het verschil tussen kamertemperatuur en ingestelde temperatuur.

Ruimtetemperatuur minus ingestelde temperatuur (Tijdens werking) Kamertemperatuur min ingestelde temperatuur

met een vermogen van meer dan 1 W doch niet meer dan 2 kW

-3.6°F -1.35°F (-2°C) (-0.75°C)

2. Indoor ventilator snelheidscontrole De binnenventilator werkt op de ingestelde snelheid door FAN SPEED CONTROL knop. Wanneer thermostaat UIT (compressor UIT), ventilator snelheid wordt zeer laag. In AUTO is de ventilatorsnelheid als volgt.

Ruimtetemperatuur minus ingestelde temperatuur (begin)

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking)

Hoog 3,15 °F (1,75 °C) of meer Med. tussen 1,8 en 3,15 °F Laag minder dan 1,8°F(1°C)

4.5°F (2.5°C) 1.8°F (1°C)

3.15°F (1.75°C)

3. De werking van de compressor en binnen/buiten ventilatorcompressor werkt door kamertemperatuurregeling en tijdsregeling. De ingestelde temperatuur wordt geregeld om 4°F (2°C) te dalen van de oorspronkelijke kamertemperatuur. De ventilator en de buitenventilator werken in dezelfde cyclus als de compressor.
  • Bij een kamertemperatuur van 73 °C of meer:
  • Wanneer de Thermostat aan staat, herhaalt de compressor zich 8 minuten AAN en 3 minuten UIT.
  • Wanneer de thermostaat is uitgeschakeld, herhaalt de compressor zich 4 minuten UIT en 1 minuut AAN.
  • Wanneer de kamertemperatuur lager is dan 73 °C (23°C).
  • Wanneer de thermostaat AAN is, herhaalt de compressor zich 2 minuten ON en 3 minuten OFF.
  • Wanneer de thermostaat is uitgeschakeld, herhaalt de compressor zich 4 minuten UIT en 1 minuut AAN.

Operatietijdtabel Voorbeeld

AAN

UIT

AAN

UIT

AAN

UIT

8 minuten 1 minuut 4 minuten 3 minuten

4. Voorkoming van vorsten Coil Frost preventie is hetzelfde als COOL modus. (21.3.) De ventilator houdt de werkelijke snelheid van het moment in stand. Wanneer de vorstpreventie van spoel werkt terwijl de compressor niet functioneert, wordt zijn snelheid echter wel de ingestelde snelheid.
Toon 4 meer labels / korte tekst op deze pagina
Ventilatorsnelheid · Thermostaat · Binnenventilator · Buitenfancompressor
Page 6 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — -3.6°F -1.35°F (-2°C) (-0.75°C)
Pagina 6 · klik om te vergroten
Pagina 6

1-3, AUTOVAAN OPERATIE 1. Horizontale vaan ECONO COOL () werking (ECONOmical operation) Wanneer de knop ECONO Cool in de koelmodus wordt gedrukt, is de ingestelde temperatuur automatisch 3,6 °F (2°C) hoger dan die van COOL. Ook de horizontale vaan schommelt in verschillende cyclus volgens de temperatuur van binnenwarmtewisselaar (binnenspoelthermistor). Door de SWING operatie voelt u zich koeler dan bij ingestelde temperatuur. Dus, ook al is de ingestelde temperatuur hoger dan die in COOL modus kan de airconditioner comfort behouden. Als gevolg daarvan kan energie worden bespaard. Om deze bewerking te annuleren, selecteert u een andere modus of drukt u op één van de volgende toetsen in ECONO COOL-operatie: ECONOCOOL/VANE CONTROLknop.

Bij het draaien van de ECONO COOL-bedieningsmodus wordt de initiële luchtstroomrichting aangepast aan Volgens de temperatuur van binnenspoelthermistor bij het begin van deze operatie, wordt volgende neerwaartse blaastijd bepaald. Als de slag is afgelast, wordt het volgende horizontale blaasuur bepaald. Voor de eerste 10 minuten wordt het schommelen uitgevoerd in tabel G~H voor snelle koeling. Ook wordt na 10 minuten wanneer het verschil tussen ingestelde temperatuur en kamertemperatuur meer dan 3,6 °F (2°C) bedraagt, de schommeloperatie uitgevoerd in tabel D~H voor een grotere koeling. De airconditioner herhaalt de swing in verschillende cyclus als volgt.

Temperatuur van de binnenspoelthermistor (°F/°C)Downward blow time (second)Horizontale blaastijd (tweede) Avan 59/15 of minder223 B59/15 to 63 /17520 C63/17/ to 64/18817 D64/18 to 68/201114 E68/20 to 70/211411 F70/21 to 72/22178 G72/22 to 75/24205 Hmeer dan 75/24232
Page 7 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 5.4°F (3°C) 1.8°F (1°C)
Pagina 7 · klik om te vergroten
Pagina 7

2 MSZ, MICROPROCESSORCONTROLE VAN HET SYSTEEM

2-1. KOELE () WERKING

1. Thermostaatcontrole Thermostat wordt aan of uit gezet door het verschil tussen kamertemperatuur en ingestelde temperatuur.

Ruimtetemperatuur minus ingestelde temperatuur (Tijdens werking) Kamertemperatuur min ingestelde temperatuur

met een vermogen van meer dan 1 W doch niet meer dan 2 kW

-1.8°F -1.35°F (-1°C) (-0.75°C)

2. Indoor ventilator snelheidscontrole De binnenventilator werkt continu op de ingestelde snelheid door FAN SPEED CONTROL knop, ongeacht het type thermostaat OFFON. In AUTO is de ventilatorsnelheid als volgt.

Ruimtetemperatuur minus ingestelde temperatuur (begin)

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking)

Hoog 3,15 °F (1,75 °C) of meer Med. tussen 1,8 en 3,15 °F Laag minder dan 1,8°F(1°C)

5.4°F (3°C) 1.8°F (1°C)

3.15°F (1.75°C)

3. Voorkoming van vorst De operationele frequentie van de compressor wordt gecontroleerd om te voorkomen dat de temperatuur van binnenwarmtewisselaar overmatig daalt. De compressor wordt 5 minuten uitgeschakeld wanneer de temperatuur van binnenspoelthermistor 37°F (3 °C) of minder gedurende 5 minuten of meer doorgaat. De binnenventilator behoudt de werkelijke snelheid van het moment.
4. Lage buitentemperatuur-werking Als de externe temperatuur daalt tot 64°F (18 °C) of minder tijdens het gebruik in COOL modus, zal de eenheid overschakelen naar de lage buitentemperatuur werking. (1) Ventilatorbediening buiten

De rotatiesnelheid van de buitenventilator vertraagt om voldoende koelcapaciteit te behouden. NOTE: Zelfs wanneer de eenheid in de "thermostat-off" status onder lage buitentemperatuur werking, het uit -

Deurventilator rotatie stopt niet. (2) Dauwdruppelpreventie Wanneer de omgevingstemperatuurthermistor 14°F (-10 °C) of minder leest (de ingestelde temperatuur is verschillend afhankelijk van het model), wanneer spoel vorst of dauwval uit binnenunit kan optreden, draait de compressor met buitenventilator UIT om ze te voorkomen. (3) Buitentemperatuurdetectieregeling Om de exacte buitentemperatuur in deze modus te detecteren, draait de compressor uit maar blijft de ventilator 3 minuten aan één keer 1 uur. Als de buitentemperatuur boven ongeveer 64°F (18 °C) stijgt, gaat het apparaat terug naar de normale COOL-modus. Indien de buitentemperatuur beneden ongeveer 64°C blijft, loopt het toestel in een lage temperatuur-modus. Andere beschermingsmiddelen werken zowel in de normale COOL-modus.

Ventilatorsnelheid

Page 8 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 3.15°F (1.75°C)
Pagina 8 · klik om te vergroten
Pagina 8

2-2. DROOG () BEDRIJF Stel temperatuur is zoals aangegeven op de juiste kaart. Het systeem voor droog bedrijf maakt gebruik van hetzelfde koelmiddelcircuit als het koelcircuit. De compressor en de ventilator binnen worden bestuurd door het kamertempo. Door dergelijke controles zal de hoeveelheid stroom binnen worden verminderd om luchtvochtigheid te verlagen zonder veel kamertemperatuurdaling.

Stel temperatuur en kamertemperatuur in droogstand

(10) (15) (20) (25) (30) (35) 1. Thermostaatcontrole Thermostaat wordt aan of uit gezet door het verschil tussen kamertemperatuur en ingestelde temperatuur.

50(10) 50 59 68 77 86 95

Begintemperatuur van de kamertemperatuur [°F(°C)]

Ruimtetemperatuur minus ingestelde temperatuur (Tijdens werking) Kamertemperatuur min ingestelde temperatuur

met een vermogen van meer dan 1 W doch niet meer dan 2 kW

-3.6°F -1.35°F (-2°C) (-0.75°C)

2. Indoor ventilator snelheidscontrole De binnenventilator werkt op de ingestelde snelheid door FAN SPEED CONTROL knop. Wanneer de thermostaat uit (compressor UIT) draait, wordt ventilatorsnelheid zeer laag. In AUTO is de ventilatorsnelheid als volgt.

Ruimtetemperatuur minus ingestelde temperatuur (begin)

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking)

Hoog 3,15 °F (1,75 °C) of meer Med. tussen 1,8 en 3,15 °F Laag minder dan 1,8°F(1°C)

4.5°F (2.5°C) 1.8°F (1°C)

3.15°F (1.75°C)

3. Voorkoming van vorsten Coil Frost preventie is hetzelfde als COOL modus. (21.3.) De ventilator houdt de werkelijke snelheid van het moment in stand. Wanneer de vorstpreventie van spoel werkt terwijl de compressor niet functioneert, wordt zijn snelheid echter wel de ingestelde snelheid. 4. Lage buitentemperatuur werking De lage buitentemperatuur werkt net zo goed als de COOL-modus. (2-1,4)

2-3. WARMTE () WERKING (MSZ) 1. Thermostaatcontrole Thermostaat wordt aan of uit gezet door verschil tussen kamertemperatuur en ingestelde temperatuur.

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking) (MSZ-FE18 MSZ-GE24)

Ruimtetemperatuur minus ingestelde temperatuur (begin)

met een gewicht van meer dan 1 kg doch niet meer dan 2 kg

1.8°F (1°C)

Ruimtetemperatuur minus ingestelde temperatuur (begin)

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking)

met een gewicht van meer dan 200 g/m2

3.6°F (2°C)

2. Indoor ventilator snelheidsregeling (1) De binnenventilator werkt op de ingestelde snelheid door FAN SPEED CONTROL knop.

In Auto is de ventilatorsnelheid als volgt.

Stel de temperatuur in minus kamertemperatuur (tijdens werking) Stel de temperaturen in min kamertemperatuur in (beginpunt)

3.6°F (2°C)

7.2°F (4°C)

High Med. Laag

tussen 0,45 en 3,6 °F (3,6°F(2°C) of meer

Less than 0.45°F(0.25°C) 0.45°F (0.25°C)

3.15°F (1.75°C)

Toon 11 meer labels / korte tekst op deze pagina
95(35) · Steltemperatuur [°F(°C)] · 86(30) · 77(25) · 68(20) · 59(15) · Ventilatorsnelheid · Thermostaat (Andere modellen) Thermostaat · Ventilatorsnelheid
Page 9 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — (MSZ-FE18 MSZ-GE24)
Pagina 9 · klik om te vergroten
Pagina 9

(2) Controle op de preventie van koude lucht

MSZ-A09/12/15/17 MSZ-FD MSZ-FE MSZ-D MSZ-GE

Wanneer de compressor niet werkt,

() als de temperatuur van kamertemperatuur thermistor lager is dan 66 °C (19°C), stopt de ventilator. () indien de temperatuur van kamertemperatuurthermistor 66 °F of meer bedraagt en

() als de temperatuur van binnenspoelthermistor minder dan 32°F (0 °C), houdt de ventilator op. () indien de temperatuur van binnenspoelthermistor 32°F (0 °C) of meer bedraagt, werkt de ventilator bij Zeer Laag. Wanneer de compressor werkt,

() indien de temperatuur van binnenspoelthermistor 104°F of meer bedraagt, werkt de ventilator bij ingestelde snelheid. () indien de temperatuur van binnenspoelthermistor minder dan 104 °F (40°C) bedraagt, en

() als de verwarming na het ontdooien begint, houdt de ventilator op. () als de temperatuur van kamertemperatuur thermistor 66°F of minder bedraagt, houdt de ventilator op. () indien de temperatuur van kamertemperatuurthermistor meer dan 66°F bedraagt, werkt de ventilator bij Zeer Laag. NOTE: Wanneer 4 minuten (MSZ-FE18 MSZ-GE24)/3 minuten (Andere modellen) zijn voorbij sinds de compressor gestart

Deze bediening wordt losgelaten ongeacht de temperatuur van kamertemperatuurthermistor en binnenspoelthermator. MSZ-A24 MSZ-GA

Wanneer de compressor niet werkt,

() indien de temperatuur van kamertemperatuurthermistor ten minste 500000 F (15°C) bedraagt, of een warmte-inlaatthermis

tor is minder dan 64°F (18 °C), de ventilator stopt. () indien de temperatuur van kamertemperatuurthermistor meer dan 500000 F (15°C), of temperaturen binnenspoel bedraagt

thermistor is meer dan 64°F (18 °C), de ventilator werkt op Zeer Laag. Wanneer de compressor werkt,

() indien de temperatuur van binnenspoelthermistor 64°F (18°C) of meer bedraagt, werkt de ventilator bij ingestelde snelheid. () indien de temperatuur van binnenspoelthermistor minder dan 64 °F (18°C) bedraagt, en

() als de verwarming na het ontdooien begint, houdt de ventilator op. () als de temperatuur van kamertemperatuurthermistor niet meer dan 500000 F (15°C) bedraagt, houdt de ventilator op. () indien de temperatuur van kamertemperatuurthermistor meer dan 500000 F (15°C), werkt de ventilator bij Zeer Laag. NOTE: Wanneer 3 minuten zijn verstreken sinds de compressor startte werking, wordt deze bediening losgelaten ongeacht het

temperatuur van kamertemperatuur thermoistor en binnenspoel thermistor. (3) Warme luchtregeling (MSZ-FD MSZ-FE MSZ-GE)

Wanneer de volgende toestand van (a. ~ c.) en de toestand van zijn voldaan op hetzelfde moment, warme luchtregeling werkt.

a.) Ventilatorsnelheid wordt gebruikt in HANDVEST. b.) Wanneer koude luchtpreventie is vrijgegeven. c.) Wanneer de ontdooiing is voltooid Wanneer de temperatuur van binnenspoelthermistor minder dan 104°F (40 °C) bedraagt. Wanneer de warme luchtregeling werkt, verandert het ventilatorsnelheidsverloop als volgt om warmte uit te blazen. Afbakening van de ventilatorsnelheid in het begin

(MSZ-FE18 MSZ-GE24)

Minder dan 4 minuten Laag 4 tot 8 minuten Med. Meer dan 8 minuten Hoog

Minder dan 2 minuten Laag 2 tot 4 minuten Med. Meer dan 4 minuten Hoog of Super hoog

De bovengrens van de ventilatorsnelheid in HANDEL is de ingestelde snelheid. Wanneer de temperatuur van binnenspoelthermistor 104°F of meer is geweest, of wanneer de ingestelde snelheid is gewijzigd, wordt deze bediening vrijgegeven en is de ventilatorsnelheid de ingestelde toerental. 3. Beginnen met overladen Wanneer de thermostaat 64°F (18 °C) of meer meet, loopt de compressor met zijn maximale frequentie gereguleerd gedurende 10 minuten na het opstarten. 4. Ontdooien (1) Beginomstandigheden van ontdooiing

Wanneer aan de volgende voorwaarden is voldaan a) ~ c) wordt begonnen met het ontdooien. a) De ontdooiingsthermistor is ongeveer 30,2°F (-1°C) of minder. b) De cumulatieve bedrijfstijd van de compressor heeft een van de ingestelde waarden bereikt (defrost interval: 40-150 min.

utes). c) Sinds het opstarten van de compressor zijn er meer dan 5 minuten verstreken.

Het ontdooiinterval wordt bepaald door de vorige ontdooitijd. Het volgende ontdooiinterval verkort of verlengt 0-20

in vergelijking met het vorige ontdooiinterval.

(Andere modellen)

Page 10 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — (21S4) OFF (COOL)
Pagina 10 · klik om te vergroten
Pagina 10

(2) Ontbreken van de ontdooiingscondities

Ontdooien wordt vrijgegeven wanneer aan een van de volgende voorwaarden is voldaan: a) De ontdooide thermostaat blijft "Defrost afwerkingstemperatuur" 30 seconden lezen.

"VERANDERING IN ONTDOOIING VAN SERVICEFUNCTIES IN DE HANDLEIDING VOOR EEN BUITENDIENST" TE VERMELDEN. b) De uitdrogingstijd is meer dan 10 minuten. c) Alle andere modus dan WARMTE wordt ingesteld tijdens het ontdooien.

Tijdkaart van ontdooiing in de WARMTE-modus (omgekeerd type)

<Indoor eenheid>

horizontaal (temperatuur van binnenspoelthermistor < 102 °F)

(39°C)

snelheid instellen binnenventilator

Zeer laag (temperatuur van binnenspoelthermistor > 64 °F)

(18°C)

UIT

<Outdoor unit>

OFF OFF

30 seconden 40 seconden 5 seconden 5 seconde

ON ON

UIT

ON (HEAT)

ON (HEAT)

R.V. spoel

(21S4) OFF (COOL)

2-4. AUTO-OMSCHAKELING OVER ··· AUTOMODUS (MSZ) Zodra de gewenste temperatuur is ingesteld, wordt het bedrijf automatisch tussen COOL en HEAT-bedrijf gewisseld. 1. Selectie modus (1) Eerste modus

In eerste instantie werkt de binnenunit alleen indoor ventilator met buiteneenheid UIT gedurende 3 minuten om huidige kamertemperatuur te detecteren. Onder de onderstaande voorwaarden wordt het werkmodus geselecteerd.

Als de kamertemperatuurthermistor meer leest dan ingestelde temperatuur, wordt COOL-modus geselecteerd. Als de kamertemperatuurthermistor ingesteld temperatuur of minder leest, wordt WARMTE modus geselecteerd.

Toon 11 meer labels / korte tekst op deze pagina
horizontale · ingestelde positie · instelpositie · Horizontale vaan · ingesteld toerental · 30 seconden · Maximale frequentie · Compressor normaal · 40 seconden · 30 seconde · Buitenventilator
Page 11 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — Tijdkaart van ontdooiing in de WARMTE-modus (omgekeerd type)
Pagina 11 · klik om te vergroten
Pagina 11

In het geval van de volgende omstandigheden wordt de bedrijfsmodus gewijzigd.

De COOL-modus verandert in de WARMTEmodus wanneer 15 minuten zijn verstreken met kamertemperatuur 2 - 4°F (1 - 2°C)

onder de ingestelde temperatuur. WARMTE-modus verandert in COOL modus wanneer 15 minuten zijn verstreken met de kamertemperatuur 2 - 4 °F (1 - 2°C)

boven de ingestelde temperatuur.

In de andere gevallen dan bovengenoemde omstandigheden wordt het huidige gebruiksmodus voortgezet.

Op-timer. NOTE2: Wanneer twee of meer binneneenheden gelijktijdig werken, kan de indoor unit die werkt in AUTO (), niet veranderen over de bedrijfsmodus (COOL ↔ HEAT) en wordt het stand-by toestand. (3) Indoor ventilatorbediening/Vaanregeling

Aangezien de ventilatorsnelheid binnen en de horizontale positie van het ruitenvat afhankelijk zijn van de gekozen modus, veranderen ze wanneer de bedrijfsmodus verandert naar de exclusieve.

2-5. MOTORBESTURING VAN DE VENTILATOR BUITEN De ventilatorsnelheid wordt overeenkomstig de compressorfrequentie omgeschakeld.

Compressorfrequentie (Hz) OmlaagOmhoog MUZ-A MUY-A MUZ-FD MUZ-FE09/12 MUZ-GA MUY-GA MUZ-GE12/15/18 MUY-GE12/15/183344 MUZ-D MUY-D MUZ-GE09 MUY-GE093954 MUZ-FE18 MUZ-GE24 MUY-GE243343

Compressorfrequentie Min. Max.

2-6. AUTOVAAN OPERATIE 1. Horizontale vaan (1) Koude luchtpreventie bij HEAT-operatie (MUZ)

Wanneer een van de volgende omstandigheden zich voordoet in het gebruik van HEAT, verandert de vaanshoek naar horizontale positie automati- cally om koude lucht blazen op gebruikers te voorkomen.

De compressor werkt niet. Ontdooien wordt uitgevoerd. Binnenspoelthermistortemperatuur niet meer dan 102°F (39°C) binnen ongeveer 3 minuten na het starten van de compressor. NOTE: Wanneer 2 of meer binneneenheden met multi-outdoor unit worden bediend, zelfs als een inpandige eenheid thermostaat UITdraait;

Deze bediening werkt niet in de binnenunit. (2) ECONO COOL () operatie (ECONOEMISCHE vluchtuitvoering) MSZ-FD en MSZ-FE09/12) Wanneer de ECONO COOL-knop in de koelmodus wordt gedrukt, wordt de ingestelde temperatuur automatisch 3,6 °F (2°C) hoger ingesteld dan die van COOL. Ook de horizontale vaan schommelt in verschillende cyclus volgens de temperatuur van binnenwarmtewisselaar (binnenspoelthermistor). Door de SWING operatie voelt u zich koeler dan bij ingestelde temperatuur. Dus, ook al is de ingestelde temperatuur hoger dan die in COOL modus kan de airconditioner comfort behouden. Als gevolg daarvan kan energie worden bespaard. Om deze bewerking te annuleren, selecteert u een andere modus of drukt u op één van de volgende toetsen in ECONO COOL-operatie: ECONOCOOL/VANE CONTROLknop.

Toon 5 meer labels / korte tekst op deze pagina
(2) Modus wijzigen · Ventilatorsnelheid · Omhoog · Hoog · Laag
Page 12 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 2-7. INVERTER SYSTEEM CONTROLE 2-7-1. Inverter hoofdvoedingscircuit
Pagina 12 · klik om te vergroten
Pagina 12

Bij het draaien van de ECONO COOL-bedieningsmodus wordt de initiële luchtstroomrichting aangepast aan Volgens de temperatuur van binnenspoelthermistor RT12 bij het begin van deze operatie, wordt volgende neerwaartse blaastijd bepaald. Als de slag is afgelast, wordt het volgende horizontale blaasuur bepaald. Voor de eerste 10 minuten wordt het schommelen uitgevoerd in tabel G~H voor snelle koeling. Ook wordt na 10 minuten wanneer het verschil tussen ingestelde temperatuur en kamertemperatuur meer dan 3,6 °F (2°C) bedraagt, de schommeloperatie uitgevoerd in tabel D~H voor een grotere koeling. De airconditioner herhaalt de swing in verschillende cyclus als volgt.

Temperatuur van de binnenspoelthermistor (°F/°C)Downward blow time (second)Horizontale blaastijd (tweede) Avan 59/15 of minder223 B59/15 to 63/17520 C63/17 to 64/18817 D64/18 to 68/201114 E68/20 to 70/211411 F70/21 to 72/22178 G72/22 to 75/24205 Hmeer dan 75/24232

2-7. INVERTER SYSTEEM CONTROLE 2-7-1. Inverter hoofdvoedingscircuit

MUZ-A09/12/15/17 MUY-A15/17 MUZ-FD MUZ-FE09/12 MSZ-GE06/09/12/15/18 MUY-GE09/12/15/18

STROOMTRANSFORMATOR

DIODEMODULE1

REACTOR

U

U

GELUIDFILTERCIRCUIT

WEERSTAND

P

VOEDING

GLADMAKENDE CONDENSATOR

MS

3~ V

N

W

W

RELAIS

INTELLIGENT

COMPRESSOR

POWERMODULE

SCHAKELSTROOMTRANSISTOR

DIODEMODULE2

BOOSTER HELIKOPTER CIRCUIT

Functie van de belangrijkste onderdelen

NAMEFUNCTIE INTELLIGENTE POWERMODULEHet levert 3-fase wisselstroom naar compressor. GLADMAKENDE CONDENSATORHet stabiliseert de DC spanning en levert het aan INTELLIGENT POWER MODULE. STROOMTRANSFORMATORHet meet de stroom van de compressormotor. DIODEMODULE 1Het zet de AC spanning om naar gelijkspanning. WEERSTANDHet absorbeert de stroomstoot om niet in het hoofdstroomcircuit te lopen als de elektriciteit aanstaat. RELAISHet houdt de RESISTOR, die drukke stroom beperkt en kortsluitend terwijl de compressor werkt. BOOSTER HELIKOPTER CIRCUITDIODEMODULE 2Het verbetert de vermogensfactor. Het regelt de bus-bar spanning. SCHAKELSTROOMTRANSISTOR REACTOR
Toon 5 meer labels / korte tekst op deze pagina
+ · ~ ~ · + · + · ~ ~
Page 13 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — REACTOR
Pagina 13 · klik om te vergroten
Pagina 13

MUZ-A24 MUY-A24 MUZ-D MUY-D MUZ-FE18 MUZ-GA MUY-GA MUZ-GE24 MUY-GE24

STROOMTRANSFORMATOR

REACTOR

P

U

U

GELUIDFILTERCIRCUIT

WEERSTAND

VOEDING

GLADMAKENDE CONDENSATOR

MS

3~ V

N

W

W

RELAIS

INTELLIGENTE POWERMODULE-VERMOGENSFACTOR

COMPRESSOR

CORRECTIE

MODULE

Functie van de belangrijkste onderdelen

NAAMFUNCTIE

Intelligente kracht module Het levert 3-fase wisselstroom aan compressor.

SMOOTHING CAPACITOR Het stabiliseert de DC spanning en levert het aan INTELLIGENT POWER MODULE.

LOPENDE TRANSFORMER Het meet de stroom van de compressormotor.

REACTOR

Het corrigeert de wisselstroom, regelt zijn spanning en verbetert de voedingsfactor. MODULE VOOR CORRECTIE VAN DE VERMOGENSFACTOR

RESSTOR Het absorbeert de stroomstoot om niet in het hoofdstroomcircuit te lopen wanneer de elektriciteit aanstaat.

RELAY Het houdt de Resistor, die drukke stroom beperkt, kortsluitend terwijl de compressor werkt.

2-7-2. Omtrek van het hoofdstroomcircuit MUZ-A09/12/15/17 MUY-A15/17 MEZ-FD MUz-FE09/12 MU Z-GE09/12/ 15/18 MUJ-GE 09/12/15/18

1. Bij het begin van de operatie De hoofdvoedingscircuit wordt gevormd wanneer RELAY bij het opstarten van COMPRESSOR is ingeschakeld. Om te voorkomen dat er stroom in het circuit terechtkomt wanneer de voeding wordt ingeschakeld, wordt RESSTOR geplaatst in een subcircuit. 2. Bij normale bedrijfsuitoefening Als AC in POWER P.C. komt Het geluid van de externe board wordt geëlimineerd in het geruis. Nadat het geluid is geëlimineerd uit AC, wordt het door DIODE MODULE 1 naar de DC getransformeerd. Gelijkstroomspanning, waaraan AC is gecorrigeerd door proces , wordt gestabiliseerd door smoothing capacitor en geleverd aan IN- TELLIGENT POWER MODULE. Gelijkstroomspanning, die in proces gestabiliseerd is , wordt door INTELLIGENT POWER MODULE omgezet naar 3-fase AC en aan COMPRESSOR geleverd. HUIDIGE TRANSFORMER, die in het stroomcircuit van COMPRESSOR wordt geplaatst, wordt gebruikt om de waarde te meten

van fasestroom en lokaliseer de poolrichting van rotor met het algoritme. PWM (Pulse width modulatie) controleert de spanning en frequentie met die stukjes informatie.

+

Page 14 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — INTELLIGENTE POWERMODULE-VERMOGENSFACTOR
Pagina 14 · klik om te vergroten
Pagina 14
3. Doel van PAM-adoptie PAM (Pulse Amplitude Modulation) is vastgesteld voor de verbetering en aanpassing aan IEC harmonische huidige emissienorm.

Overzicht van eenvoudige partiële schakelmethode In conventionele invertermodellen, DIODE MODULE rectifi es AC spanning naar gelijkspanning, SMOOTHING CAPACITOR maakt zijn gelijkstroom golfvorm glad en INTELLIGENT POWER Module zet de Gelijkstroom om te imiteren wisselspanning opnieuw met het oog op aandrijving van de compressor motor. Het is echter moeilijk geweest om de IEC harmonische stroomemissiestandaard te halen door boven circuit uit te voeren omdat harmonisch wordt gegenereerd in het ingangsstroomgolfvorm en vermogensfactor naar beneden komt. De eenvoudige gedeeltelijke schakelmethode met PAM, die deze keer is toegepast, plaatst en gebruikt BOOSTER CHOPPER CIRCUIT alvorens AC spanning in het algemene passieve-methode converter circuit te corrigeren. Aangezien de harmonischen onderdrukt worden en het piek van golfvorm lager wordt door BOOSTER CHOPPER CIRCUIT toe te voegen zoals hierboven vermeld, kan de ingangsstroomgolfform verbeterd worden en kan de eis van IEC-harmonische stroomemissienorm worden gesaboteerd. Aangezien de schakel met het nulpunt gesynchroniseerd is, heeft deze eenvoudige partiële schakelaarmethode een lagere en-ergy verlies ten opzichte van actieve fi lter methode. Bovendien wordt de output en efficiëntie verbeterd door combinatie met vectorgestuurde omvormer om zo het vermogen van INTELLIGENT POWER MODULE te verhogen.

Invoerstroomgolfvorm zonder PAM-ingangsstroom golfvorm met PAM

  • Vanwege de tijd van geen elektriciteit;
  • De krachtfactor wordt erger.
  • Harmonische wordt groter.
  • Door de toename van energieke tijd;
  • De krachtfactor wordt beter.
  • Harmonisch wordt onderdrukt.

Loslaten van energie opgeslagen in L.

Peak gaat naar beneden.

De energietijd is kort voor het geval L-inductantie klein is.

De energietijd wordt verlengd door optimalisatie van L-inductie.

Geen elektriciteit loopt in diode module omdat de spanning aan beide zijden van gladmaken condensator is hoger dan ingangsspanning.

Verplichte energie-inval door over te schakelen.

Inputspanning · Invoerstroom

Page 15 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — INTELLIGENTE POWERMODULE-VERMOGENSFACTOR
Pagina 15 · klik om te vergroten
Pagina 15
4. Intelligente energiemodule

INTELLIGENTE POWER MODULE bestaat uit de volgende componenten · IGBT (x6): Converteert DC golfvorm naar 3-fase AC-golfvorm en geeft het af. · Drive Circuit: Drives transistors. · Beschermingscircuit: Beschermt transistors tegen overstroming. Aangezien de bovenstaande componenten allemaal zijn geïntegreerd in INTELLIGENT POWER MODULE, heeft Intelligent Power Module een verdienste om het controlecircuit te vereenvoudigen en miniaturiseren. 5. Eliminatie van elektrisch lawaai

Geluidsfiche CIRCUIT, dat wordt gevormd door *CMC COILS en condensatoren geplaatst op de POWER P.C. board, elimineert elektrische geluid van wisselstroom die wordt geleverd aan de hoofdvoeding circuit. Dit circuit voorkomt ook dat het elektrische geluid gen- gelekt in de omvormercircuit uit te lekken.

*CMC COILSGemeenschappelijke modus wurgspoelen

MUZ-A24 MUY-A 24 MUZ-D MUY - D MUZ - FE18 MUZ, GA MUY GA MUZ GI24 MUI-GE24 1. Bij het begin van de operatie De hoofdvoedingscircuit wordt gevormd wanneer RELAY bij het opstarten van COMPRESSOR is ingeschakeld. Om te voorkomen dat er stroom in het circuit terechtkomt wanneer de voeding wordt ingeschakeld, wordt RESSTOR geplaatst in een subcircuit. 2. Bij normale bedrijfsuitoefening Wanneer AC loopt in ruisfilter P.C. Het geluid van de externe board wordt geëlimineerd in het geruis. Nadat het geluid is geëlimineerd uit AC, wordt het gecorrigeerd naar DC door REACTOR en POWER FACTOR CORRECTIE MODULE. Indien de

De werkfrequentie wordt 25 Hz of meer, gelijkspanning stijgt naar 370 V. Gelijkstroomspanning, waaraan AC is gecorrigeerd door proces , wordt gestabiliseerd door SMOOTHING Capacitor en geleverd aan IN-TELLIGENT POWER MODULE. De DC (Bus voltage), die in proces gestabiliseerd is , wordt door INTELLIGENT POWER MODULE omgezet naar 3-fase AC en aan COMPRESSOR geleverd. HUIDIGE TRANSFORMER, die in het stroomcircuit van COMPRESSOR wordt geplaatst, wordt gebruikt om de waarde te meten

van fasestroom en lokaliseer de poolrichting van rotor met het algoritme. PWM (Pulse width modulatie) controleert de spanning en frequentie met die stukjes informatie. 3. Verbetering van de vermogensfactor Boosterspoelreactor en POWER FACTOR CORRECTIE MODULE corrigeren AC naar DC en de spanning ervan regelen. In het motoraandrijvingssysteem van sinusgolfregeling kan de krachtfactor worden verbeterd door harmonischen te verminderen. De maximale spanning van de DC die wordt geleverd aan het invertercircuit en zijn golfvorm glad maken. 4. Intelligente energiemodule Intelligente krachtmodule bestaat uit de volgende componenten. · IGBT (x6): Converteert gelijkstroomgolfvorm naar 3-fase wisselstroom golfvorm en geeft het uit. · Drive Circuit: Drives transistors. · Beschermingscircuit: Beschermt transistors tegen overstroom. Aangezien de bovenstaande componenten allemaal zijn geïntegreerd in INTELLIGENT POWER MODULE, heeft Intelligent Power Module een verdienste om het controlecircuit vereenvoudigd en geminiaturiseerd te maken. 5. Eliminatie van elektrisch lawaai De detectoren worden gevormd door *CMC COILS, *NMC COILs en condensators die op de POWER P.C. zijn geplaatst. board, elimineert elektrische geluid van wisselstroom die wordt geleverd aan de hoofdvoeding circuit. Dit circuit voorkomt ook dat het elektrische geluid in de omvormercircuit uitlekt.

*CMC COILSCommon mode stikspoelen *NMC COILS: Normale modus wurgspoel
Page 16 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — INTELLIGENTE POWERMODULE-VERMOGENSFACTOR
Pagina 16 · klik om te vergroten
Pagina 16

2-7-3. Sinusgolfregeling In deze airconditioners, compressor uitgerust borstelloze DC motor die geen Hall element heeft. Kortom, de motor is sensorloos. Het is echter noodzakelijk om de polaire richting van rotor te lokaliseren, zodat borstelloze DC mo- tor efficiënt kan worden aangedreven. De algemene detectiemethode van de poolrichting voor een dergelijke DC-motor is het lokaliseren vanaf de spanning die wordt opgewekt door niet-energetische stator. Daarom is het noodzakelijk om een bepaalde tijd te hebben waarin de stator niet-energetisch wordt gemaakt voor de positiedetectie van rotors wanneer de spanning van geleverde vermogen onder de indruk is. De motor is dus aangedreven door een vierkante golfregeling (het conventionele aandrijfsysteem) die de motor alleen energie geeft wanneer het bereik van elektrische hoek binnen 120° ligt omdat hij gedwongen wordt om niet te worden gevoed in 30° bij aanvang en einde van één hoop in één golfvormcyclus (180°), als de spanning onder druk staat. Echter, koppel pulsatie treedt op bij rotatie in deze methode wanneer de stroom-dragende fasen worden overgeschakeld naar andere fases in volgorde. Daarom wordt sinusgolfregeling voor deze airconditioners toegepast omdat het de fase-tot-fasestroomgolfvorm soepeler (sinusgolf) kan maken om zo de motor beter en soepel te kunnen besturen.

  • 2-7-4. Kenmerken van sinusgolfregeling bij een penseelloze gelijkstroommotor
  • Hoewel gewone 3-fase inductiemotor energie nodig heeft om de magnetische fi eld van rotor te prikkelen, is deze niet zonder penseelloze DC motor. Dus, hogere efficiëntie en koppel worden verstrekt.
  • Deze bediening zorgt voor de meest efficiënte golfvorm die overeenkomt met het toerental van compressormotor.
  • De rotatie kan worden ingesteld op hoger in vergelijking met het conventionele motoraandrijvingssysteem. De tijd waarin airconditioners met minder energie kunnen worden bediend is dus langer dan conventionele modellen. Dit kan jaarlijks elektrisch verbruik besparen.
  • Vergeleken met de vierkante golfregeling wordt het koppel pulsatie verminderd bij rotatie, zodat de motor stiller werkt.
  • Aangezien de respons en efficiëntie van motor worden verbeterd in sinus wave control, kan fi ner aanpassing worden verstrekt.

Gelijkstroommotor wisselstroommotoren

Rotor Permanente magneet is ingebed. Gespannen door magnetische vulling van de stator

Rotorpositie Signaal Noodzakelijk Onnodig

In een borstelloze DC motor is permanente magneet in de rotor ingebed. Daarom heeft het geen energie nodig om de rotor te prikkelen

Net als AC motor doet. De frequentie van de driefasenstroom die aan de stator wordt toegevoerd, moet echter worden geregeld in het polair richtingspatroon dat zich in de rotor bevindt om zo een efficiënte motor te kunnen besturen. Het regelen van de 3-fase wisselstroomfrequentie betekent ook het beheersen van de timing om te schakelen naar de polariteit van stator. Daarom moet de polaire richting van rotor worden gedetecteerd. 2-7-5. Controlemethode voor het roterend toerental Sinusgolfregeling maakt de stroomtransformatoren real time detectie van de waarde van de stroom die in mo-tor loopt, loceert de rotorpositie vanaf de gedetecteerde waarde en beslist of spanning onder druk moet worden gezet en of frequentie gewijzigd dient te worden. In vergelijking met de conventionele controle en rotor positie detectie methode, sinus wave control kan fi ner aanpassing van de spanning van het geleverde vermogen. De waarde van de stroom die in de motor loopt wordt bepaald door elk motorkarakteristiek.

Page 17 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — INTELLIGENTE POWERMODULE-VERMOGENSFACTOR
Pagina 17 · klik om te vergroten
Pagina 17

2-8. OPERATIONELE FREQUENTIEREGELING VAN DE BUITENEENHEID 1. Omtrek De operationele frequentie is als volgt: Ten eerste wordt de doelfrequentie bepaald op basis van het verschil tussen kamertemperatuur en ingestelde temperatuur. Ten tweede wordt de beoogde operationele frequentie geregeld door middel van bescherming tegen lozingstemperatuur, hogedrukbescherming, elektrische stroombeveiliging en overbelastingsbeveiliging alsmede door een maximale/minimumfrequentie.

2. Maximale/minimumfrequentie in elke bedrijfsmodus.

Operationele frequentie (Hz) COOL HEAT (MUZ) DRY Minimum Maximum Minimum Maximum Maximum Maximum MUZ-A09 32 70 32 76 32 57 MUZ-A12 32 73 32 71 32 57 MUZ-A15 MUY-A15 10 82 15 93 10 68 MUZ-A17 MUY-A17 10 87 15 93 10 68 MUZ-A24 MUY-A24 15 110 15 108 15 102 MUZ-FD09 10 52 10 100 10 41 MUZ-FD12 10 62 10 100 10 41 MUZ-FE09 10 52 10 100 10 41 MUZ-FE12 10 62 10 100 10 41 MUZ-FE18 26 120 26 124 26 120 MUZ-D30 20 84 20 87 20 83 MUZ-D36 20 91 20 94 20 83 MUY-D30 20 79 — — 20 79 MUY-D36 20 92 — — 20 79 MUZ-GA24 MUY-GA24 15 101 15 108 15 101 MUZ-GE09 MUY-GE09 28 93 30 105 28 48 MUZ-GE12 MUY-GE12 20 98 30 98 30 55 MUZ-GE15 MUY-GE15 15 90 15 102 15 54 MUZ-GE18 MUY-GE18 15 98 15 108 15 83 MUZ-GE24 MUY-GE24 26 120 26 124 26 120

De werkfrequentie in de COOL-modus wordt beperkt door de bovenste limiet frequentie na 1 uur of 0,5 ~ 1 uur zoals getoond

beneden voor dauwpreventie. Het is een nominale frequentie of minder.

Bovengrensfrequentie Nominale frequentie of minder

1 uur of 0,5~1 uur

Toegepast model · Maximale frequentie · Tijd

Page 18 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — AAN
Pagina 18 · klik om te vergroten
Pagina 18

2-9. UITBREIDINGSKLEPREGELING (LEV-BESTURING)

(1) Omtrek van de LEV-besturing De basisregeling voor LEV bestaat uit het instellen van een openingsgraad van LEV tot de standaardopeningsgraden die zijn ingesteld per operationele frequentie van de compressor. Wanneer echter veranderingen in de binnen-/buitentemperatuur of andere factoren leiden tot schommelingen van het klimaatbelastingsniveau, werkt LEV ook om een opener LEV te corrigeren op basis van ontladingstemperatuur (schiltemperatuur) van de compressor en ontwikkelt zo zijn prestaties.

Minimum33 pulsen (MUZ-A09/12/15/17 MUY-A15/17)

59 pulsen (MUZ-A24 MUY-A24 MUZ-GA MUY-GA) 54 pulsen (MUZ-FD MUZ-FE MUZ-GE MUY-GE) 58 pulsen (MUZ-D MUY-D) Maximaal: 500 pulsen

Actueringssnelheid Open: 40 pulsen/seconde Sluiten: 90 polsen/tweede Openingsgradeninstelling LEV openingsgraad wordt altijd ingesteld in de richting van het openen. (Bij het opnieuw inrichten van de openingsgraad wordt LEV eenmaal te gesloten en vervolgens door opengaan naar behoren aangepast.

Eenheid UIT LEV blijft bij maximale openingsgraad (bereikt de maximumopeningsgraad ongeveer 15 minuten na het stoppen van compressor) De afstandsbediening ON LEV is gepositioneerd. (Eerst volledig afgesloten bij nul pulsen en dan gepositioneerd.) Gedurende 1 tot 15 minuten na het starten van de compressor

LEV wordt op standaardopeningsgraad vastgesteld volgens de operationele frequen-cy van compressor. Sinds het opstarten van de compressor zijn er meer dan 15 minuten verstreken

LEV openingsgraad wordt gecorrigeerd om doelontlading temperatuur van compressor te krijgen. (Voor een lagere ontladingstemperatuur dan de doeltemperatuur, wordt LEV in sluitrichting correct-ed.) (Bij hogere lozings temperatuur dan bij het bereiken van de gewenste temperatuur is LEV cor-gecorreeerd in openingsrichting).

Het kan meer dan 30 minuten duren om de doeltemperatuur te bereiken, afhankelijk van bedrijfsomstandigheden. Thermostaat UIT LEV wordt aangepast in exclusieve openingsgraad voor thermostaat UIT. Thermostaat ON LEV wordt op dezelfde manier gecontroleerd als nadat de compressor is gestart. Ontdooien in de HEAT-modus LEV wordt aangepast om 500 pulsen te openen

Airconditioner UIT (thermostaat uit)

De openingsgraad wordt gecorrigeerd volgens de ontladingstemperatuur. (Refereren naar (3))

Geboden om de standaard openingsgraad te openen

AAN

Toon 12 meer labels / korte tekst op deze pagina
Standaardspecificatie · Controlebereik · Algemene werking · (2) Tijdkaart · Airconditioner AAN · Positie · LEV openingsgraad · Ongeveer 15 minuten · Tijd · Operationele frequentie · van de compressor · UIT tijd
Page 19 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — COOL / HEAT ( MUZ ) °F/°C
Pagina 19 · klik om te vergroten
Pagina 19

F E D C B A

30 50 70 90 110 130 23 38 53 69 84 99 (Hz) (Hz)

(Andere modellen) (MUZ-FE18 MUZ-GE24 MUY-GE24)

Operationele frequentie van de compressor

a) Referentiewaarde van de temperatuur bij lozing

COOL / HEAT ( MUZ ) °F/°C

Toegepast model A B C D E F

MUZ-A09/12 COOL 122/50 127/53 140/60 151/66 158/70 158/70 HEAT 113/45 126/52 138/59 154/68 169/76 169/76

MUZ-A15/17 MUY-A15/17 COOL 129/54 136/58 147/64 158/70 158/70 158/70 HEAT 120/49 136/58 151/66 165/74 180/82 185/85

MUZ-A24 MUY-A24 MUZ-GA MUY-GA COOL 140/60 140/60 140/60 145/63 147/64 153/67 HEAT 140/60 145/63 149/65 153/67 158/70 158/70

MUZ-FD MUZ-FE09/12 COOL 120/49 131/55 142/61 153/67 162/72 169/76 HEAT 109/43 124/51 138/59 156/69 167/75 176/80

MUZ-FE18 MUZ-GE24 MUY-GE24 COOL 131/55 142/61 151/66 162/72 171/77 178/81 HEAT 115/46 133/56 151/66 167/75 181/83 187/86

MUZ-D MUY-D COOL 126/52 135/57 149/65 167/75 183/84 187/86 HEAT 131/55 140/60 149/65 154/68 162/72 167/75

MUZ-GE09 MUY-GE09 COOL 126/52 136/58 149/65 153/67 158/70 160/71 HEAT 109/43 122/50 131/55 138/59 149/65 156/69

MUZ-GE12 MUY-GE12 COOL 127/53 140/60 147/64 153/67 162/72 169/76 HEAT 109/43 124/51 138/59 156/69 167/75 176/80

MUZ-GE15 MUY-GE15 COOL 120/49 131/55 147/64 153/67 162/72 169/76 HEAT 109/43 124/51 138/59 156/69 167/75 176/80

MUZ-GE18 MUY-GE18 COOL 135/57 140/60 144/62 153/67 165/74 178/81 HEAT 140/60 149/65 158/70 167/75 167/75 167/75

Bij COOL-werking past de binnenspoelthermistoren (hoofd en sub) eenvormigheid van temperatuur bij het warmtewisselaar aan, terwijl wanneer er sprake is van temperatuurverschil, LEV-openingsgraad in de binnenrolthermators wordt aangepast om ongeveer 18°F (10 °C) te bereiken onder de doeltemperatuur in bovenstaande tabel.

(3) Controlegegevens · Doel ontladingstemperatuur

Page 20 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 69.8°F (21°C)
Pagina 20 · klik om te vergroten
Pagina 20

2-10. VOORWARMTEBEHEERSING MUZ-FD MOZ-FE MUZ -GE 1. Outline Compressor wordt geactiveerd om het opstarten van compressor bij een lage buitentemperatuur te verbeteren, zelfs wanneer de compressor is gestopt. 2. Voorwarmtebeheersing

AAN

UIT

AAN

UIT

68°F (20°C)

Voorwarmteregeling OP toestand (1) Compressor werkt niet. (De voorwarmtebeheersing is echter nog 30 minuten na het stoppen van de compressor uitgevallen, ongeacht of deze wordt gebruikt.

30 minuten 1 uur

van de buitentemperatuur.) (2) Buitentemperatuur is 68°F (20 °C) of lager. De buitentemperatuur wordt uur in het oog gehouden en wanneer de temperatuur van een

68 °F (20°C) of lager, voorwarmteregeling wordt ingeschakeld. Wanneer de voorwarmteregeling wordt ingeschakeld, wordt een compressor ongeveer 50 W (40-60 W) energieker gemaakt. (Compressor en ventilator worden niet bediend.)

MUZ-D MUY-D 1. Omtrek De compressor wordt geactiveerd, zelfs als hij niet werkt. Dit is om warmte te genereren bij de winding ter verbetering van het opstarten voorwaarde.

69.8°F (21°C)

30 minuten 30 minuten30 minuten 30 min 30 minuten

15 minuten 30minuten 30 minutes

Startbewerking

met een ontdooiingsthermistor van 69,8 of meer gewichtspercenten

2. Voorverwarmingscontrole AAN conditie (1) De voorwarmteregeling wordt 15 of 30 minuten nadat de schakelaar is ingeschakeld, in werking gesteld. (2) 30 min. Nadat de eenheid is gestopt, wordt het voorwarmtebeheer gedurende 15 of 30 minuten ingeschakeld en 30 minuten uitgeschakeld. Dit

wordt herhaald zoals in de grafiek is aangegeven totdat het breekstuk UIT is. Wanneer de ontdooiingsthermistor minder dan 69,8°F (20 °C) leest, wordt het voorverhitten gedurende 30 minuten aangestuurd. Wanneer de ontdooiingsthermistor 69,8 °F (21°C) of meer leest, wordt het voorverhitten gedurende 15 minuten aangestuurd. NOTE: Wanneer de unit met een afstandsbediening wordt gestart, is voorwarmteregeling UIT. Compressor gebruikt 50 W bij pre-

warmtebeheersing is ingeschakeld.

Toon 8 meer labels / korte tekst op deze pagina
Compressor · Voorverwarmingsregeling · Buitentemperatuur · Uitschakelen · Compressor AAN UIT · Defrost thermistor · Voorverhitten OP OFF · Breaker ON
Page 21 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — REACTOR
Pagina 21 · klik om te vergroten
Pagina 21

3 MXZ MICROPROCESSORBESTURING

3-1. INVERTER SYSTEEMREGELING

3-1-1. Inverter hoofdvoedingscircuit

STROOMTRANSFORMATOR

REACTOR

P

U

U

GELUIDFILTERCIRCUIT

VOEDING

WEERSTAND

GLADMAKENDE CONDENSATOR

MS

3~ V

N

W

W

RELAIS

INTELLIGENTE POWERMODULE-VERMOGENSFACTOR

COMPRESSOR

CORRECTIE

MODULE

Functie van de belangrijkste onderdelen

NAAMFUNCTIE

Intelligente kracht module Het levert 3-fase wisselstroom aan compressor.

SMOOTHING CAPACITOR Het stabiliseert de DC spanning en levert het aan INTELLIGENT POWER MODULE.

LOPENDE TRANSFORMER Het meet de stroom van de compressormotor.

REACTOR

Het corrigeert de wisselstroom, regelt zijn spanning en verbetert de voedingsfactor. MODULE VOOR CORRECTIE VAN DE VERMOGENSFACTOR

RESSTOR Het absorbeert de stroomstoot om niet in het hoofdstroomcircuit te lopen wanneer de voeding wordt ingeschakeld.

RELAY Het houdt de Resistor, die drukke stroom beperkt, kortsluitend terwijl de compressor werkt.

3-1-2. Omtrek van het hoofdstroomcircuit

1. Bij het begin van de operatie De hoofdvoedingscircuit wordt gevormd wanneer RELAY bij het opstarten van COMPRESSOR is ingeschakeld. Om te voorkomen dat er stroom in het circuit terechtkomt wanneer de voeding wordt ingeschakeld, wordt RESSTOR geplaatst in een subcircuit. 2. Bij normale bedrijfsuitoefening Wanneer AC in noise fi lter P.C. loopt Het geluid van de externe board wordt geëlimineerd in het geruis. Nadat het geluid is geëlimineerd uit AC, wordt het door REACTOR en POWER FACTOR CORRECTIE MODULE naar DC gecorrigeerd. Indien de

De werkfrequentie wordt 25 Hz of meer, gelijkspanning stijgt naar 370 V. Gelijkstroom, waaraan AC is gecorrigeerd door proces , wordt gestabiliseerd door smoothing capacitor en geleverd aan IN- TELLIGENT POWER MODULE. De DC (Bus voltage), die in proces gestabiliseerd is , wordt door INTELLIGENT POWER MODULE omgezet naar 3-fase AC en aan COMPRESSOR geleverd. HUIDIGE TRANSFORMER, die in het stroomcircuit van COMPRESSOR wordt geplaatst, wordt gebruikt om de waarde te meten

van fasestroom en lokaliseer de poolrichting van rotor met het algoritme. PWM (Pulse width modulatie) controleert de spanning en frequentie met die stukjes informatie.

+

Page 22 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 3 MXZ MICROPROCESSORBESTURING
Pagina 22 · klik om te vergroten
Pagina 22

3. Verbetering van de vermogensfactor Boosterspoelreactor en POWER FACTOR CORRECTIE MODULE corrigeren AC naar DC en de spanning ervan regelen. In het motoraandrijvingssysteem van sinusgolfregeling kan de krachtfactor worden verbeterd door harmonischen te verminderen. De maximale spanning van de DC die wordt geleverd aan het invertercircuit en zijn golfvorm glad maken. 4. Intelligente energiemodule Intelligente krachtmodule bestaat uit de volgende componenten. · IGBT (x6): Converteert gelijkstroomgolfvorm naar 3-fase wisselstroom golfvorm en geeft het uit. · Drive Circuit: Drives transistors. · Beschermingscircuit: Beschermt transistors tegen overstroom. Aangezien de bovenstaande componenten allemaal zijn geïntegreerd in INTELLIGENT POWER MODULE, heeft Intelligent Power Module een verdienste om het controlecircuit te simplified en miniaturized. 5. Eliminatie van elektrisch lawaai De detectoren zijn een soort van "micro-ionisatie" die wordt gevormd door de CMC COILS, *NMC COLISS en condensators op het P.C. board, elimineert elektrische geluid van wisselstroom die wordt geleverd aan de hoofdvoeding circuit. Deze schakeling voorkomt ook dat het elektrische geluid in de stroomkring van de vervormer uitlekt. *CMC COILS: Common mode stikspoelen *NMC COILs: Normale modus wurgspoelen

3-1-3. Sinusgolfregeling In deze airconditioners, compressor uitgerust borstelloze DC motor die geen Hall element heeft. Kortom, de motor is sensorloos. Het is echter noodzakelijk om de polaire richting van rotor te lokaliseren, zodat borstelloze DC mo- tor efficiënt kan worden aangedreven. De algemene detectiemethode van de poolrichting voor een dergelijke DC-motor is het lokaliseren vanaf de spanning die wordt opgewekt door niet-energetische stator. Daarom is het noodzakelijk om een bepaalde tijd te hebben waarin de stator niet-energetisch wordt gemaakt voor de positiedetectie van rotors wanneer de spanning van geleverde vermogen onder de indruk is. De motor is dus aangedreven door een vierkante golfregeling (het conventionele aandrijfsysteem) die de motor alleen energie geeft wanneer het bereik van elektrische hoek binnen 120° ligt omdat hij gedwongen wordt om niet te worden gevoed in 30° bij aanvang en einde van één hoop in één golfvormcyclus (180°), als de spanning onder druk staat. Echter, koppel pulsatie treedt op bij rotatie in deze methode wanneer de stroom-dragende fasen worden overgeschakeld naar andere fases in volgorde. Daarom wordt sinusgolfregeling voor deze airconditioners toegepast omdat het de fase-tot-fasestroomgolfvorm soepeler (sinusgolf) kan maken om zo de motor beter en soepel te kunnen besturen.

  • 3-1-4. Kenmerken van sinusgolfregeling bij een penseelloze gelijkstroommotor
  • Hoewel gewone 3-fase inductiemotor energie nodig heeft om de magnetische fi eld van rotor te prikkelen, is deze niet zonder penseelloze DC motor. Dus, hogere efficiëntie en koppel worden verstrekt.
  • Deze bediening zorgt voor de meest efficiënte golfvorm die overeenkomt met het toerental van compressormotor.
  • De rotatie kan worden ingesteld op hoger in vergelijking met het conventionele motoraandrijvingssysteem. De tijd waarin airconditioners met minder energie kunnen worden bediend is dus langer dan conventionele modellen. Dit kan jaarlijks elektrisch verbruik besparen.
  • Vergeleken met de vierkante golfregeling wordt het koppel pulsatie verminderd bij rotatie, zodat de motor stiller werkt.
  • Aangezien de respons en efficiëntie van motor worden verbeterd in sinus wave control, kan fi ner aanpassing worden verstrekt.

Gelijkstroommotor wisselstroommotoren

Rotor Permanente magneet is ingebed. Gespannen door magnetische vulling van de stator

Rotorpositie Signaal Noodzakelijk Onnodig

In een borstelloze DC motor is permanente magneet in de rotor ingebed. Daarom heeft het geen energie nodig om de rotor te prikkelen

Net als AC motor doet. De frequentie van de driefasenstroom die aan de stator wordt toegevoerd, moet echter worden geregeld in het polair richtingspatroon dat zich in de rotor bevindt om zo een efficiënte motor te kunnen besturen. Het regelen van de 3-fase wisselstroomfrequentie betekent ook het beheersen van de timing om te schakelen naar de polariteit van stator. Daarom moet de polaire richting van rotor worden gedetecteerd.

3-1-5. Controlemethode voor het roterend toerental Sinusgolfregeling laat de stroomtransformatoren real time detectie uitvoeren van de waarde van de stroom die in het mo-tor loopt, loceert de rotorpositie vanaf de gedetecteerde waarde en bepaalt of spanning onder druk moet worden gezet en of frequentie gewijzigd dient te worden. In vergelijking met de conventionele controle en rotor positie detectie methode, sinus wave control kan fi ner aanpassing van de spanning van het geleverde vermogen. De waarde van de stroom die in de motor loopt wordt bepaald door elk motorkarakteristiek.

Page 23 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 3 MXZ MICROPROCESSORBESTURING
Pagina 23 · klik om te vergroten
Pagina 23

3-2. UITBREIDINGSKLEPREGELING (LEV-BESTURING) Lineaire expansieklep (LEV) wordt bestuurd door

Status binneneenheid LEV opening Stop van alle indoor unit Opening voor stop → 500 pulsen in 15 minuten

Wanneer de buitenunit werkt, stoppen sommige binneneenheden en werken sommigen.

KOEL5 pulsen (volledig gesloten) HEAT: (MXZ-2A / 3A30NA/2B): 140 impulsen (licht geopend)

: (MXZ-3A30NA- 1 /4A/3B/4B): 100 → 59 pulsen

Wanneer de buitenunit werkt (wanneer de andere binneneenheid in werking is): 5 pulsen Als het buitenapparaat stopt. (Wanneer de andere binneneenheid stopt of thermo UIT): Houd LEV opening voor stop → 500 pulsen in 15 minuten

Thermostaat UIT in de koel- of droogmodus

  • De LEV-opening voor elke binneneenheid wordt bepaald door aanpassing toe te voegen aan het aantal bedrijfseenheden en de capaciteitsklasse bij standaard opening, op basis van bijvoorbeeld 130 pulsen openen in standaardopening 1 → minimaal 80 impulsen/maximum 205 pulsen (Capaciteitscode 4 bij één eenheid) (Capacity code 1 bij drie eenheden werking)
  • Na het starten van de werking, aanpassing volgens intake super warmte, ontlading temperatuur is opgenomen bij standaard opening. 1 OPMERKING: LEV opening in elke frequentie bij DRY-operatie en COOL operatie is de

Thermostaat ON in de koel- of droogmodus

Hetzelfde. De regelaars voor de frequentieregeling van snelheid en compressors verschillen echter. Zie 3-3. OPERATIONELE FREQUENTIERANGE (Voor zover de binneneenheidssnelheidsregeling gaat, zie DRY-operatie in MICRO-PROCESORCONTROLING in een interne eenheid.)

  • Als de buitenunit werkt. (Wanneer de andere binneneenheid werkt): 140 pulsen
  • Als de buitenunit stopt. (Wanneer de andere binneneenheid stopt of thermo-off): Houd LEV opening voor stop → 500 pulsen in 15 minuten

Thermostaat UIT in WARMTE-modus

  • De LEV-opening voor elke binneneenheid wordt bepaald door aanpassing toe te voegen aan het aantal bedrijfseenheden en de capaciteitsklasse bij standaard opening, op basis van bijvoorbeeld 120 pulsen openen in standaardopening 1 → Minimaal 70 impulsen/maximum 165 pulsen (Capaciteitscode 4 bij één bedrijf) (Capacity code 1 bij drie eenheden werking)
  • Na het starten van de werking wordt opening degene die aanpassing volgens ontladingstemperatuur werd toegevoegd aan basisopening. 1

Thermostaat AAN in WARMTE-modus

1 LEV opening wanneer de buitenunit werkt: Bovengrens 500 pulsen, onderlimiet 53 impulsen (MXZ-2A/3A30NA/2B)/59 pulsen (MXZ-3A30NA- 1 /4A/3B/4B).

Page 24 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — <MXZ-3A30NA>
Pagina 24 · klik om te vergroten
Pagina 24

MXZ-2A20NA/3A30NA

Onderstaande tabel toont de rol van Exclusive LEV en Receiver LEV in elke modus.

COOL Exclusieve LEV

HEAT Exclusieve LEV ×

LEV

LEV

(MXZ-3A30NA)

In de COOL-modus passen beide binnenspoelthermistoren (één hoofd en één sub) eenvormigheid van temperatuur bij het warmtewisselaar aan, terwijl wanneer er sprake is van temperatuurverschil, LEV opening wordt aangepast om superwarmte te verminderen. Deze actie heet Verdamping Temperatuur Bescherming.

De openingspuls van de Receiver LEV is in koelbedrijf aan standaard nr. 3 bevestigd, evenals die van elke Exclusieve LEV bij verwarming. De openingspuls wordt echter aangepast aan de norm nr. 4 of nr. 5 wanneer de temperatuurbescherming van het ontladingsproces of hogedrukbeveiliging werkt.

Daarnaast wordt het ook veranderd in norm nr. 2 of nr.1 wanneer de openingspuls van elke Exclusieve LEV 100 puls of minder bij koelwerkzaamheden wordt, of dat geldt voor Receiver LEV tijdens verwarmingsbewerkingen.

<MXZ-2A20NA>

LEV opening (pulse) COOL WET

1 eenheid 2 eenheden 1 eenheid 3 stuks

Standaard nr.

1 200 150 120 120 2 300 320 140 140 3 400 360 160 160 4 450 410 220 220 5 500 500 280 280

<MXZ-3A30NA>

LEV opening (pulse) COOL WET

1 eenheid 2 eenheden 3 eenheden 1 unit 2 eenheden 4 eenheden

Standaard nr.

1 150 250 2 250 320 320 300 300 300 3 350 360 370 450 380 380 4 400 410 420 460 400 390 5 450 460 470 470 450 440

Toon 18 meer labels / korte tekst op deze pagina
Circulatiehoeveelheid · Afvoertemperatuur · Hoge druk · Verdamping · Distributie van de controlecapaciteit · Temperatuurbescherming · Bescherming · Bescherming binnenwarmte · Exclusief · Buiten warmtewisselaar · wisselaar · Ontvanger · Ontvangster · Aantal· werkende indoor units · Aantal · bedrijfsbinneneenheden
Page 25 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-3A30NA
Pagina 25 · klik om te vergroten
Pagina 25

Bepaling van de standaardopening LEV in elke binneneenheid

  • De standaard opening bevindt zich op de rechte lijn, die elk standaardpunt in het gedeelte verbindt waar deze wordt verdeeld over zeven volgens de bedrijfsfrequentie van compressor zoals aangegeven in onderstaande figuur. (De opening van het LEV wordt geregeld naar rato van de werkfrequentie.) NOTA: De opening is bij de standaardopening aangepast volgens de binnen-eenheidsomstandigheden.
  • De helling van de standaardopening in elk openingspunt verandert echter niet met de oorspronkelijke curve.
  • Voeg de opening in het verschil van capaciteit toe aan de standaardopening 1 tot en met 8, wanneer de inhoud van de binnenunit code 1 niet meet.
  • Voeg in onderstaande tabel het verschil tussen de bedrijfsomstandigheden toe om voor elke binneneenheid een bepaalde LEV-opening te bepalen wanneer 2 of 3 eenheden tegelijk worden gebruikt. OPMERKING: Zelfs wanneer de aangepaste standaardopening het rijbereik van 59 tot 500 puls overschrijdt, is er sprake van een werkelijke uitrij-

De opening is tussen 59 en 500 pulsen.

01 02 03 04 05 06 07 08 09 10

23 54 69 84 100 115 131 146 38 14 32 41 50 59 68 77 86 MXZ-2A/2B MXZ-3A/4A 23

Compressor-werkfrequentie (Hz)

MXZ-2A20NA

Standaard opening (puls) LEV Opening (code) 1 2 3 4 5 6 7 8 9 10 COOL 120 130 136 146 156 160 170 180 190 200 HEAT 100 110 120 130 146 160 170 190 200

Verschil in capaciteit Verschil van werkingsnummer Code3,4 Code5,6 Code7,8 Code9,10 Code11,12 Code13,14 Code15of hoger dan 2 COOL 3 6 9 12 15 25 35 -20 HEAT 3 6 5 52 55 65 75 0

MXZ-3A30NA

Standaard opening (puls) LEV Opening (code) 1 2 3 4 5 6 7 8 9 10 COOL 126 130 134 138 140 142 182 228 296 310 HEAT 140 146 150 170 180 200 224 244 272 280

Verschil in capaciteit Verschil van werkingsnummer Code3,4 Code5,6 Code7,8 Code9,10 Code11,12 Code13,14 Code15of hoger dan 2 3 COOL 3 6 9 12 15 25 35 -20 -30 HEAT 3 6 6 9 52 55 65 75 0

4Hz · LEV Opening (code)

Page 26 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 2 COOL -20 HEAT 30
Pagina 26 · klik om te vergroten
Pagina 26

MXZ-2A20NA1 , 2 MXz-2B20NA MX Z-2B2Na1 Exclusieve LEV

Standaard opening (puls) LEV Opening (code) 1 2 3 4 5 6 7 8 9 10 COOL 120 130 136 146 156 160 170 180 190 200 HEAT 248 248 258 266 274 280 286 292 300 306

Verschil in capaciteit Verschil van werkingsnummer Code3,4 Code5,6 Code7,8 Code9,10 Code11,12 Code13,14 Code15of hoger dan 2 COOL 3 6 9 12 15 25 35 -20 HEAT 3 6 5 52 55 65 75 30

Standaard opening (puls) LEV Opening (code) 1 2 3 4 5 6 7 8 9 10 COOL 140 150 160 170 180 190 200 200 200200 HEAT 80 84 90 110 120 130 140 150160 170

Operatienummer Verschil in werkingsnummer

2 COOL -20 HEAT 30

MXZ-3A30NA1 MXZ-4A36NA MXZ-3B24NA MXZ-3B30NA MXZ-4B36NA

Standaard opening (puls) LEV Opening (code) 1 2 3 4 5 6 7 8 9 10 COOL 126 130 134 138 150 160 170 180 190 200 HEAT 248 248 258 266 274 280 286 292 300 306

Verschil in capaciteit Verschil van operatienummer Code3,4 Code5,6 Code7,8 Code9,10 Code11,12 Code13,14 Code15of hoger dan 2 3 4(MXZ-4A/4B) COOL 3 6 9 12 15 25 35 -20 -30 -30 HEAT 3 6 9 52 55 65 75 -4 -8 -12

Standaard opening (pulse) LEV Opening (code) 1 2 3 4 5 6 7 8 9 10 COOL 270 280 290 300 310 320 330 340 350 360 HEAT 140 152 160 170 180 200 224 244 274 280

Operatienummer Verschil in werkingsnummer

2 3 4(MXZ-4A/4B) COOL 28 56 84 HEAT -45 -60 -60

Capaciteitscode 3 4 7 9 10 12 Binneneenheid 06 09 12 15 17 24

LEV van de ontvanger · Exclusieve LEV · LEV van de ontvanger

Page 27 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-3A30NA
Pagina 27 · klik om te vergroten
Pagina 27
  • KOLDOORGEDROOGDE WARMTE ontladingstemperatuur
  • Elke correctie
  • (Elke gasleiding temperatuur thermistor - Minimale gaspijp temperatuur thermometer) 1
  • (Belangrijkste binnenspoelthermistor - Sub indoor spoelthermeistor)

1 Voer dit uit, wanneer het aantal bedrijfseenheden 2 eenheden of meer bedraagt. (Uitsluitend MXZ-2A20NA en MXz-3A30NA) 2 Corrigeer de LEV opening door middel van ontladingstemperatuur.

(1) LEV openingscorrectie door ontladingstemperatuur

De doelontladingstemperatuur wordt bepaald aan de hand van het frequentiegebied en het aantal bedrijfseenheden in de com-drukker.

MXZ-2A20NA

Target discharge temperature (°F/°C) COOL HEAT Number of operating unit 1 unit 2 units 1 unit 2 units Minimum ~ 23 95/35 136.4/58 122/50 122/50 24 ~ 38 104/40 140/60 132.8/56 122/50 39 ~ 54 120.2/49 149/65 140/60 132.8/56 55 ~ 69 136.4/58 154.4/68 140/60 140/60 70 ~ 85 149/65 158/70 140/60 140/60 86 ~ Maximum 158/70 158/70 140/60 140/60

MXZ-2A20NA1 , 2 MXZ-2B20NA MXZ-2B20NA1

Target discharge temperature (°F/°C) COOL HEAT Number of operating unit 1 unit 2 units 1 unit 2 units Minimum ~ 23 95/35 136.4/58 122/50 122/50 24 ~ 38 104/40 140/60 132.8/56 122/50 39 ~ 54 120.2/49 149/65 140/60 132.8/56 55 ~ 69 136.4/58 154.4/68 145.4/63 140/60 70 ~ 85 149/65 158/70 150.8/66 140/60 86 ~ Maximum 158/70 158/70 152.6/67 140/60

MXZ-3A30NA

Target discharge temperature (°F/°C) COOL HEAT Number of operating unit 1 unit 2 units 3 units 1 unit 2 unit 3 units Minimum ~ 14 95/35 131/55 134.6/57 125.6/52 143.6/62 122/50 15 ~ 23 104/40 131/55 134.6/57 136.4/58 150.8/66 131/55 24 ~ 32 120.2/49 136.4/58 145.4/63 149/65 165.2/74 140/60 33 ~ 41 136.4/58 140/60 149/65 154.4/68 172.4/78 152.6/67 42 ~ 50 149/65 149/65 158/70 154.4/68 172.4/78 161.6/72 51 ~ 59 154.4/68 154.4/68 163.4/73 154.4/68 172.4/78 168.8/76 60 ~ 68 158/70 158/70 167/75 154.4/68 172.4/78 168.8/76 69 ~ 77 167/75 163.4/73 176/80 154.4/68 172.4/78 168.8/76 78 ~ 86 167/75 167/75 179.6/82 154.4/68 172.4/78 168.8/76 87 ~ Maximum 167/75 176/80 179.6/82 172.4/78 172.4/78 168.8/76

Toon 7 meer labels / korte tekst op deze pagina
<Correction> · Operatiefrequentie · van compressor (Hz) · Werkfrequentie · Compressor (Z) · Werkingsfrequentie · compressor- (HZ)
Page 28 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-2A20NA
Pagina 28 · klik om te vergroten
Pagina 28

MXZ-3A30NA1 MXZ-4A36NA MXZ-3B24NA MXZ-3B30NA MXZ-4B36NA

Doelontladingstemperatuur (°F/°C) COOL WARMTE Aantal bedrijfseenheid

1 eenheid 2 eenheden 3 eenheden 4 stuks (MXZ-4A/4B) 1 eenheid 2 eenheden 3 eenheden 4 stuks (MXZ-4A/4B) Minimum ~ 14 95/35 131/55 134.6/57 140/60 125.6/52 143.6/62 122/50 122/50 15 ~ 23 107.6/42 131/55 134.6/57 140/60 136.4/58 150.8/66 131/55 122/50 24 ~ 32 120.2/49 136.4/58 145.4/63 140/60 149/65 165.2/74 140/60 122/50 33 ~ 41 136.4/58 140/60 149/65 143.6/62 154.4/68 172.4/78 152.6/67 122/50 42 ~ 50 149/65 149/65 158/70 149/65 154.4/68 172.4/78 161.6/72 131/55 51 ~ 59 154.4/68 154.4/68 163.4/73 158/70 154.4/68 172.4/78 168.8/76 140/60 60 ~ 68 158/70 158/70 167/75 158/70 154.4/68 172.4/78 168.8/76 140/60 69 ~ 77 167/75 163.4/73 176/80 161.6/72 154.4/68 172.4/78 168.8/76 140/60 78 ~ 86 167/75 167/75 179.6/82 161.6/72 154.4/68 172.4/78 168.8/76 140/60 87 ~ Maximum 167/75 176/80 179.6/82 161.6/72 172.4/78 172.4/78 168.8/76 140/60

De LEV-opening corrigeren op basis van het verschil tussen de doelontladingstemperatuur en -temperatuur.

MXZ-2A MXZ-2B

Afvoertemperatuur (°F/°C) LEV-openingscorrectie (pulse)

COOL WARMTE Meer dan Doel ontladingstemperatuur+18/10 5 8 Doel lozing temperatuur + 18/10 tot Doel lossen temperatuur + 9/5 4 3 Doel lostemperatuur + 9-5- naar Doel lekken temperatuur + 3.6/2 2 1 Doel afvoer temperatuur + 3,6/2 aan Doel loosting temperatuur - 3.6/2 0 0 Doel vloed temperatuur - 3,6/2 aan Doel lozing temperatuur - 9/5-1 -1 Richt ontlading temperatuur - 9-5 tot Doel

MXZ-3A MXZ-4A MXZ-3B MXZ-4B

Afvoertemperatuur (°F/°C) LEV-openingscorrectie (pulse)

COOL WARMTE Meer dan Doelontladingstemperatuur + 21.6/12 4 6 Doelontladingstemperatuur + 21,6/12 tot Doelontlading temperatuur + 9/5 2 Doel ontlading temperatuur+ 9/5 naar Doel lozing temperatuur + 5.4/3 1 1 Doel lossen temperatuur + 5,4/3 aan Doel lekken temperatuur - 5.4/3 0 0 Doel vloed temperatuur - 5,4/3 naar Doel lozing temperatuur - 9/5-1 -1 Doel lostemperatuur - 9-5-0 tot Doel loosting temperatuur - 21.6.12 -3 -2 Doel diffusie temperatuur - 21,6-12 of minder -8

(2) Afzonderlijke correctie (COOL, DRY)

(Opstand door de afzonderlijke superwarmte) a) Corrigeer het LEV afzonderlijk aan de hand van temperatuurverschil tussen elke gasleidingstemperatuur en de minimale gaspijptemperatuur van allen.

Bereken elke superwarmte van de eenheid met onderstaande uitdrukking;

(Super warmte) = (Elke gasleiding temperatuur) - (Minimum gas leidingtemperatuur) De correctie wordt afzonderlijk uitgevoerd volgens elke superwarmte in de onderstaande tabel.

MXZ-2A20NA

MXZ-3A30NA

Oververhitte (°F/°C) LEV-openingscorrectie (pulse) Meer dan 16.2/9 3 10.8/6 tot 16/9 2 5.4/3 tot en met 10,8/6 1 5.4/3 of minder 0

Oververhitte (°F/°C) LEV-openingscorrectie (pulse) Meer dan 16.2/9 12 10.8/6 tot 16.2/9 8 5.4/3 tot en met 10,8/6 4 5.4/3 of minder 0

Werkfrequentie · van compressor (Hz)

Page 29 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-2A20NA2
Pagina 29 · klik om te vergroten
Pagina 29

b) De LEV afzonderlijk te corrigeren door temperatuurverschil . .RT

∆RT (°F/°C) LEV opening correction (pulse) 10.8/6 ∆RT 2 7.2/4 ∆RT < 10.8/6 1 ∆RT < 7.2/4 1

Bovendien, verlagen van de doelontlading temperatuur die overeenkomt met .

∆ RT (°F/°C) Temperature to be decreased (°F/°C) 10.8/6 ∆RT 18/10 7.2/4 ∆RT< 10.8/6 9/5 ∆RT < 7.2/4 9/5

3-3. OPERATIONEEL FREQUENTIEBEREIK

MXZ-2A20NA

unit Capaciteitscode COOL (Hz) DRY (HZ) HEAT (H Z) Min. Max. Min. Max. Ontdooien

4 20 65 25 48 92 92 7 20 85 30 48 92 92 9,10 20 100 75 48 100 100 12 20 100 75 48 100 100

8 ~ 10 30 105 52 58 112 100 11 ~ 13 30 105 52 58 112 100 14 ~ 16 30 105 52 58 112 100 17 ~ 20 105 100 58 112 100

MXZ-2A20NA1

unit Capaciteitscode COOL (Hz) DRY (HZ) HEAT (H Z) Min. Max. Min. Max. Ontdooien

4 20 65 35 48 92 92 7 20 85 34 48 92 92 9,10 20 93 75 48 92 92 12 20 93 75 48 92 92

8 ~ 10 30 93 52 58 110 101 11 ~ 13 30 93 52 58 110 101 14 ~ 16 30 93 52 58 110 101 17 ~ 30 93 93 58 110 101

MXZ-2A20NA2

unit Capaciteitscode COOL (Hz) DRY (HZ) HEAT (H Z) Min. Max. Min. Max. Ontdooien

4 20 65 25 30 92 92 7 20 85 34 30 92 92 9,10 20 93 75 30 92 92 12 20 93 75 30 92 92

8 ~ 10 40 93 53 58 112 100 11 ~ 13 40 93 53 58 112 100 14 ~ 16 40 93 53 58 112 100 17 ~ 40 93 93 58 112 100

Aantal werkzaamheden · aantal operaties · aantal activiteiten

Page 30 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-3A30NA1 MXZ-4A36NA
Pagina 30 · klik om te vergroten
Pagina 30

MXZ-2B20NA

unit Capaciteitscode COOL (Hz) DRY (HZ) HEAT (H Z) Min. Max. Min. Max. Ontdooien

3, 4 20 65 25 30 92 92 7 20 85 34 30 92 92 9, 10 20 93 75 30 92 92 12 20 93 75 30 92 92

2 ~ 7 30 93 53 58 112 100 8 ~ 10 30 93 53 58 112 100 11 ~ 13 30 93 53 58 112 100 14 ~ 16 30 93 53 58 112 100 17 ~ 30 93 93 58 112 100

MXZ-2B20NA1

unit Capaciteitscode COOL (Hz) DRY (HZ) HEAT (H Z) Min. Max. Min. Max. Ontdooien

3, 4 20 65 30 30 92 92 7 20 85 30 30 92 92 9, 10 20 93 38 30 92 92 12 20 93 62 30 92 92

5 ~ 7 30 93 58 58 112 99 8 ~ 10 30 93 58 58 112 99 11 ~ 13 30 93 58 58 112 99 14 ~ 16 30 93 58 58 112 99 17 ~ 30 93 58 58 112 99

MXZ-3A30NA

unit Capaciteitscode COOL (Hz) DRY (HZ) HEAT (H Z) Min. Max. Min. Max. Ontdooien

4 15 58 20 22 48 48 7 15 58 25 22 48 48 9,10 15 62 44 22 62 58 12 15 68 44 22 90 58

8 ~ 10 24 80 31 35 70 58 11 ~ 13 24 80 31 35 90 58 14 ~ 16 24 80 31 35 94 58 17 ~ 24 80 59 35 94 58 3 12 ~ 52 90 65 39 94 58

MXZ-3A30NA1 MXZ-4A36NA

unit Capaciteitscode COOL (Hz) DRY (HZ) HEAT (H Z) Min. Max. Min. Max. Ontdooien

4 25 58 25 20 70 58 7 25 58 25 20 70 58 9,10 25 71 25 20 80 58 12 25 80 35 20 80 58

8 ~ 10 25 80 31 20 80 58 11 ~ 13 25 80 31 20 80 58 14 ~ 16 25 80 42 20 80 58 17 ~ 25 80 42 20 80 58 3 (MXZ-3A) 12 ~ 25 80 52 20 80 58 3 (MXZ-4A) 12 ~ 25 90 52 20 103 58 4 (MXZ-4A) 16 ~ 25 90 52 20 113 58

Toon 4 meer labels / korte tekst op deze pagina
Aantal werkzaamheden · aantal operaties · aantal activiteiten · aantal bewerkingen
Page 31 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-3B24NA MXZ-3B30NA MXZ-4B36NA
Pagina 31 · klik om te vergroten
Pagina 31

MXZ-3B24NA MXZ-3B30NA MXZ-4B36NA

unit Capaciteitscode COOL (Hz) DRY (HZ) HEAT (H Z) Min. Max. Min. Max. Ontdooien

3,4 15 58 22 25 70 70 7 15 58 22 25 70 70 9,10 15 71 31 25 80 80 12 15 80 42 25 80 80

5 ~ 7 25 80 35 35 80 80 8 ~ 10 25 80 35 35 80 80 11 ~ 13 25 80 35 35 80 80 14 ~ 16 25 80 35 35 80 80 17 ~ 25 80 52 35 80 80 3 (MXZ- 3B) 9 ~ 52 80 52 39 80 80 3 (MXZ-4B) 9 ~ 52 90 52 39 103 80 4 (MXZ-4B) 12 ~ 62 90 70 52 113 80

3-4. WARMTEONTDOOIINGSREGELING (1) Beginomstandigheden van ontdooiing

Wanneer aan de volgende voorwaarden is voldaan a) ~ c) wordt begonnen met het ontdooien. a) De ontdooiingsthermistor is 26.6°F (-3 °C) of minder. b) De cumulatieve bedrijfstijd van de compressor heeft een van de ingestelde waarden bereikt (defrost interval: 40-150 min.

utes). c) Sinds het opstarten van de compressor zijn er meer dan 5 minuten verstreken.

Het ontdooiinterval wordt bepaald door de vorige ontdooitijd. Het volgende ontdooiinterval verkort of verlengt 0-20

in vergelijking met het vorige ontdooiinterval. (2) Ontbreken van de ontdooiingscondities

Ontdooiing wordt vrijgegeven wanneer aan een van de volgende voorwaarden is voldaan: a) De ontdooiingsthermistor blijft 50.7°F (10,4 °C). b) De uitdrogingstijd bedraagt meer dan 10 minuten. c) Alle andere modus dan WARMTE wordt ingesteld tijdens het ontdooien.

3-5. TEMPERATUURREGELING VAN DE AFVOERTEMPERATUUR Deze bescherming regelt de compressor AAN/UIT en werkingsfrequentie volgens temperatuur van het ontladingstemperatuur-thermistor.

(1) Compressor AAN/UIT Wanneer de temperatuur van de ontladingstemperatuur thermistor hoger is dan 240,8°F (116 °C), houdt het controlemechanisme de compressor tegen. Wanneer de temperatuur van de ontladingstemperatuur thermistor 176°F (80°C) bedraagt (2A/3A30NA/2B)/ 212°F (100°C) (3A30NA-

1 /4A/3B/4B) of minder, de bediening start de compressor. (2) Compressor werkingsfrequentie Wanneer de temperatuur van de ontladingstemperatuur thermistor naar verwachting hoger is dan 240,8°F (116 °C), neemt het controleapparaat 12 Hz af ten opzichte van de huidige frequentie. Wanneer de temperatuur van de ontladingstemperatuur thermistor naar verwachting hoger is dan 231,8°F (111 °C) en minder dan 240,8°F (115°C), neemt het controleapparaat 6 Hz af ten opzichte van de huidige frequentie. Wanneer de temperatuur van de ontladingstemperatuur thermistor naar verwachting hoger is dan 219,2°F (104°C) en lager dan 231,8 °F (111°C), wordt het controlemechanisme ingesteld op de huidige frequentie.

Aantal bedrijfsactiviteiten

Page 32 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-2B20NA1 MXZ-3B MXZ-4B
Pagina 32 · klik om te vergroten
Pagina 32

3-6. VENTILATORBEDIENING BUITEN De ventilatorsnelheid wordt geschakeld naar gelang van het aantal bedrijfsbinnenunits en de compressorfrequentie.

MXZ-2B20NA

Omhoog Ventilatorsnelheid

Omhoog MXZ-2B20NA 30 40

Compressorfrequentie Min. Max.

Of, de binnenspoelthermistor is 113 - . - F (45°C) of minder bij HEAT werking, ventilator snelheid is terug naar normaal.

MXZ-2B20NA1 MXZ-3B MXZ-4B

De COOL Fan snelheid verandert zodat de condenserende temperatuur binnen het doelbereik blijft.

Revolutie per minuut (rpm)

MXZ-2B20NA1 MXZ-3B MXZ-4B

1 100 100 2 150 150 3 200 200 4 250 250 5 300 300 6 350 350 7 400 400 8 450 450 9 500 500 10 550 550 11 600 600 12 650 650 13 700 700 14 750 750

Frequency (Hz) Target condensing temperature (°F/°C) ~24 87.8/31-95.0/35 25~34 91.4/33-98.6/37 35~44 95.0/35-102.2/39 45~54 98.6/37-105.8/41 55~64 98.6/37-105.8/41 65~ 98.6/37-105.8/41

De HEAT Ventilatorsnelheid wordt ingesteld op basis van de compressorfrequentie.

Omhoog Ventilatorsnelheid

MXZ-2B20NA- 1 MXZ-3B MXZ-4B Omhoog 30 50 Down 23 40

Compressorfrequentie Min. Max.

Toon 8 meer labels / korte tekst op deze pagina
Compressorfrequentie (Hz) · Hoge · Laag · Ventilatorsnelheid · Compressorsnelheid (HZ) · Ventielsnelheid · Hoog · Low
Page 33 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — -1.8°F -1.35°F (-1°C) (-0.75°C)
Pagina 33 · klik om te vergroten
Pagina 33

3-7. VOORWARMTEREGELING MXZ-2A20NA-1 , 2 MXZ-3A30NA- 1 MXZA-4A36NA MXS-2B20NA MXZ-2B2NA-1 MXEZ-3B24NA M XZ-3B30NA MXIZ-4B36NA

De compressor wordt gevoed, zelfs als hij niet werkt. Dit is om warmte te genereren bij de winding ter verbetering van het opstarten voorwaarde.

69.8°F (21°C)

30 minuten 30 minuten30 minuten 30 min 30 minuten

15 minuten 30minuten 30 minutes

Startbewerking

met een ontdooiingsthermistor van 69,8 of meer gewichtspercenten

1. De voorverwarming wordt 15 of 30 minuten ingeschakeld, nadat de schakelaar is aangezet. 2. 30 minuten nadat de eenheid is gestopt, wordt het voorverhitten gedurende 15 of 30 minuten ingeschakeld en 30 minuten uitgeschakeld. Dit wordt herhaald zoals in de grafiek getoond totdat het breekstuk UIT is.

Wanneer de ontdooiingsthermistor minder dan 69,8°F (21 °C) leest, wordt het voorverhitten gedurende 30 minuten aangestuurd. Wanneer de ontdooiingsthermistor 69,8 °F (21°C) of meer leest, wordt het voorverhitten gedurende 15 minuten aangestuurd.

3-8. KOELE WERKING

1. Thermostaatcontrole Thermostat wordt aan of uit gezet door het verschil tussen kamertemperatuur en ingestelde temperatuur.

Ruimtetemperatuur minus ingestelde temperatuur (Tijdens werking) Kamertemperatuur min ingestelde temperatuur

met een vermogen van meer dan 1 W doch niet meer dan 2 kW

-1.8°F -1.35°F (-1°C) (-0.75°C)

2. Voorkoming van vorst De operationele frequentie van de compressor wordt gecontroleerd om te voorkomen dat de temperatuur van het warmtewisselaar binnen overmatig daalt. Compressor wordt 5 minuten uitgeschakeld wanneer de temperatuur van binnenspoelthermistor verder gaat 37,4°F (3 °C) of minder gedurende 5 minuten of meer.
Toon 5 meer labels / korte tekst op deze pagina
Aanschakelen · Compressor AAN UIT · Defrost thermistor · Voorverhitten OP OFF · Breaker ON
Page 34 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 1.8°F (1°C)
Pagina 34 · klik om te vergroten
Pagina 34

3-9. DROGE WERKING

1. Thermostaatcontrole Thermostat wordt aan of uit gezet door het verschil tussen kamertemperatuur en ingestelde temperatuur.

Ruimtetemperatuur minus ingestelde temperatuur (Tijdens werking) Kamertemperatuur min ingestelde temperatuur

met een vermogen van meer dan 1 W doch niet meer dan 2 kW

-3.6°F -1.35°F (-2°C) (-0.75°C)

2. Voorkoming van vorsten Coil Frost preventie is hetzelfde als COOL modus. (3-8.2.)

3-10. WARMTEBEWERKING

1. Thermostaatcontrole Thermostat wordt aan of uit gezet door het verschil tussen kamertemperatuur en ingestelde temperatuur.

Ruimtetemperatuur minus ingestelde temperatuur (begin)

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking)

MXZ-2A/3A/4A

met een gewicht van meer dan 200 g/m2

3.6°F (2°C)

MXZ-2B/3B/4B

Ruimtetemperatuur minus ingestelde temperatuur (begin)

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking)

met een gewicht van meer dan 200 g/m2

1.8°F (1°C)

2. Hogedrukbeveiliging Bij HEAT-bediening detecteert de binnenspoelthermistor de temperatuur van de warmtewisselaar. De werkfrequentie van de compressor wordt gecontroleerd om te voorkomen dat de condenserende druk buitensporig toeneemt.

Thermostaat

Page 35 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — 4.5°F (2.5°C) 1.8°F (1°C)
Pagina 35 · klik om te vergroten
Pagina 35

4 MFZ MICROPROCESSORBESTURING

4-1. KOELE () WERKING

1. Thermostaatcontrole Zie MXZ MICROPROCESSOR CONTROL, COOL OPERATION (3-8.1.).
2. Indoor ventilator snelheidscontrole De binnenventilator werkt continu op de ingestelde snelheid door FAN SPEED CONTROL knop, ongeacht het type thermostaat OFFON. In AUTO is de ventilatorsnelheid als volgt.

Ruimtetemperatuur minus ingestelde temperatuur (begin)

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking)

Hoog 3,15 °F (1,75 °C) of meer Med. tussen 1,8 en 3,15 °F Laag minder dan 1,8°F(1°C)

5.4°F (3°C) 1.8°F (1°C)

3.15°F (1.75°C)

3. Voorkoming van vorsten Zie MXZ MICROPROCESSOR CONTROL, COOL OPERATION (3-8.2.).

4-2. DROOG () BEDRIJF Het systeem voor droog bedrijf maakt gebruik van hetzelfde koelmiddelcircuit als het koelcircuit. De compressor en de ventilator binnen worden bestuurd door het kamertempo. Door dergelijke controles zal de hoeveelheid stroom binnen worden verminderd om luchtvochtigheid te verlagen zonder veel kamertemperatuurdaling.

Stel temperatuur en kamertemperatuur in droogstand

°F

50 59 68 77 86 95

°F

1. Thermostaatcontrole Zie MXZ MICROPROCESSOR CONTROL, DRY OPERATION (3-9.1.).
2. Indoor ventilator snelheidscontrole De binnenventilator werkt op de ingestelde snelheid door FAN SPEED CONTROL knop. Wanneer thermostaat UIT (compressor OFF) ventilatorsnelheid wordt Zeer Laag. In AUTO is de ventilatorsnelheid als volgt.

Ruimtetemperatuur minus ingestelde temperatuur (begin)

Ruimtetemperatuur minus ingestelde temperatuur (tijdens werking)

Hoog 3,15 °F (1,75 °C) of meer Med. tussen 1,8 en 3,15 °F Laag minder dan 1,8°F(1°C)

4.5°F (2.5°C) 1.8°F (1°C)

3.15°F (1.75°C)

3. Voorkoming van vorsten Coil Frost preventie is hetzelfde als COOL modus. (4-1.3) De ventilator in de binnenlucht behoudt de werkelijke snelheid van het moment.
Toon 4 meer labels / korte tekst op deze pagina
Ventilatorsnelheid · Stel temperatuur in · Initiële kamertemperatuur · Ventilatiesnelheid
Page 36 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — SLUITEN
Pagina 36 · klik om te vergroten
Pagina 36

4-3. WARMTE () WERKING

1. Thermostaatcontrole Zie MXZ MICROPROCESSOR CONTROL, HEAT OPERATIE (3-10.1.).
2. Indoor ventilator snelheidsregeling (1) De binnenventilator werkt op de ingestelde snelheid door FAN SPEED CONTROL knop.

In Auto is de ventilatorsnelheid als volgt.

Stel de temperatuur in minus kamertemperatuur (tijdens werking) Stel de temperaturen in min kamertemperatuur in (beginpunt)

3.6°F (2°C)

7.2°F (4°C)

High Med. Laag

tussen 0,45 en 3,6 °F (3,6°F(2°C) of meer

Less than 0.45°F(0.25°C) 0.45°F (0.25°C)

3.15°F (1.75°C)

(2) Controle op de preventie van koude lucht

Wanneer de compressor niet werkt: () Als de temperatuur van kamertemperatuur thermoistor RT11 minder dan 66.2°F is, houdt de ventilator op. () Indien de temperatuur van kamertemperatuur thermistor RT11 is 66,2°F of meer en

() als de temperatuur van binnenspoelthermistor minder dan 32°F bedraagt, houdt de ventilator op. () als de temperatuur van binnenspoelthermistor 32°F of meer bedraagt, werkt de ventilator bij Zeer Laag. Wanneer de compressor werkt: () Als de temperatuur van binnenspoelthermistor 104°F of meer bedraagt, dan functioneert de ventilator op ingestelde snelheid. () Indien de temperatuur van binnenspoelthermistor minder dan 104 °F bedraagt en

() als de verwarming na het ontdooien begint, houdt de ventilator op. () als de temperatuur van kamertemperatuur thermostaat RT11 is 66,2°F of minder, houdt de ventilator op. () indien de temperatuur van kamertemperatuurthermistor RT11 meer dan 66.2°F bedraagt, werkt de ventilator bij Zeer Laag.

  • NOTE:
  • Wanneer 2 of meer binneneenheden met een multitype buitenunit worden bediend, werkt de ventilator afwisselend bij Zeer Laag of stopt in thermostaat-off units terwijl ten minste één eenheid is thermostaat aan.
  • Wanneer 3 minuten verstreken zijn sinds de compressor is gestart, wordt deze bediening losgelaten ongeacht de temperatuur van RT11 en binnenspoelthermistor.
3. Hogedrukbeveiliging Bij HEAT-bediening detecteert de binnenspoelthermistor de temperatuur van de warmtewisselaar. De werkfrequentie van de compressor wordt gecontroleerd om te voorkomen dat de condenserende druk buitensporig toeneemt. 4. Defrosting Zie MXZ MICROPROCESSOR CONTROL, HEAT DEFROSTING CONTROLE (3-4.).

Tijdkaart van ontdooiing in de WARMTE-modus (omgekeerd type)

<Indoor eenheid>

snelheid instellen binnenventilator (boven)

Zeer laag (temperatuur van binnenspoelthermistor > 64,4°F)

UIT

ON ON

UIT

OPEN OF DICHT OPENEN OF SLUITEN

SLUITEN

Meer labels / korte tekst op deze pagina tonen
Ventilatorsnelheid · verticaal · ingestelde positie · ingesteld · Horizontale vaan · instel snelheid · 30 seconden · binnenventilator (onder) · Damper
Page 37 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-2B20NA1 MXZ-3B MXZ-4B
Pagina 37 · klik om te vergroten
Pagina 37

4-4. AUTO-WISSEL OVER ··· AUTOMATISCH MODUS Zodra de gewenste temperatuur is ingesteld, wordt het bedrijf automatisch tussen COOL en HEAT-bedrijf gewisseld. 1. Selectie modus (1) Eerste modus

In eerste instantie werkt de binnenunit alleen indoor ventilator met buiteneenheid UIT gedurende 3 minuten om huidige kamertemperatuur te detecteren. Onder de onderstaande voorwaarden wordt het werkmodus geselecteerd.

Als de kamertemperatuurthermistor RT11 meer leest dan ingestelde temperatuur, wordt COOL-modus geselecteerd. Als de kamertemperatuurthermistor RT11 ingesteld temperatuur of minder leest, wordt HEAT-modus geselecteerd. (2) Wijziging van modus

In het geval van de volgende omstandigheden wordt de bedrijfsmodus gewijzigd.

De COOL-modus verandert in de WARMTE modus wanneer 15 minuten zijn verstreken met kamertemperatuur 35,6°F onder het ingestelde niveau

temperatuur. WARMTE-modus verandert in COOL modus wanneer 15 minuten zijn verstreken met de kamertemperatuur 35,6°F boven het ingestelde

temperatuur.

In de andere gevallen dan bovengenoemde omstandigheden wordt het huidige gebruiksmodus voortgezet.

Op-timer. NOTE2: Wanneer twee of meer binneneenheden gelijktijdig werken, kan de indoor unit die werkt in AUTO (), niet veranderen over de bedrijfsmodus (COOL HEAT) en wordt het een stand-by toestand. (3) Indoor ventilatorbediening/Vaanregeling

Aangezien de ventilatorsnelheid binnen en de horizontale positie van het ruitenvat afhankelijk zijn van de gekozen modus, veranderen ze wanneer de bedrijfsmodus verandert naar de exclusieve.

4-5. MOTORBESTURING BINNENVENTILATOR (1) Rotatiefrequentie feedback control De binnenventilator motor is uitgerust met een rotatiefrequentie sensor, en geeft signaal naar de microprocessor om- terug te voeren van de roterende frequentie. De vergelijking van de huidige rotatiefrequentie met de doelrotatiefrequentie (Super High, High, Med., Low) past de microprocessor aan om de stroomwisselfrequentie dicht bij de gewenste draaifrequentie te brengen. Met deze bediening, wanneer de ventilatorsnelheid wordt geschakeld, verandert de rotatiefrequentie soepel.

Super High Super High

Med.

(2) Fan motor lock-up bescherming Wanneer het roterende frequentie feedback signaal 12 seconden niet heeft uitgang, (of wanneer de microprocessor kan het signaal niet detecteren voor 12 seconden) energie die aan de ventilatormotor wordt gestopt. Dan de microprocessor opnieuw detectie 3 keer elke 30 seconden. Als de microprocessor het signaal nog steeds niet kan detecteren, wordt de ventilatormotor als vergrendeld beschouwd. Wanneer de ventilatormotor sluit, knippert OPERATIEINDICATORlamp aan en uit om het motorische afwijking van de waaier te tonen.

Toon 4 meer labels / korte tekst op deze pagina
Rotationele frequentie · Hoog · Laag · tijd
Page 38 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — OPEN
Pagina 38 · klik om te vergroten
Pagina 38

4-6. AUTO VANE OPERATIE Horizontale vaan

(1) Koude luchtpreventie bij HEAT-operatie

Wanneer een van de volgende omstandigheden zich voordoet in HEAT-operatie, verandert de vaanshoek naar verticale positie automati- cally om koude lucht blazen op gebruikers te voorkomen.

De compressor werkt niet. Ontdooien wordt uitgevoerd. De binnenspoelthermistor leest 75.2°F of lager. De temperatuur van de binnenspoelthermistor stijgt vanaf 75,2°F of lager maar bedraagt niet meer dan 102,2° F.

Binnenspoelthermistortemperatuur

Verticale positie 102,2°F (39°C) 75,2°V (25°C)

Positie.

Indoor ventilatormotor (Lower) in COOL Operation

Verschil tussen kamertemperatuur en ingestelde temperatuur tijdens bedrijf

Verschil tussen kamertemperatuur en ingestelde temperatuur tijdens werking Damper

OPEN

SLUITEN

35.6°F (2°C)

44.6°F (7°C)

Indoor ventilator motor (Lower) in WARMWERKING

Binnenspoel thermoistor temperatuur Damper

Binnenspoelthermistortemperatuur

OPEN

SLUITEN

95°F (35°C)

104°F (40°C)

  • Voor de binnenventilatormotor (boven), zie "Indoor ventilatorsnelheidsregeling (21,2, 2-2.2, 2-3-2)" en "INDOOR FAN MOTORCONTROLE (2-5)."

Bij het draaien van de ECONO COOL-bedieningsmodus wordt de initiële luchtstroomrichting aangepast aan "Horizontaal." Volgens de temperatuur van binnenspoelthermistor bij het begin van deze operatie, wordt volgende neerwaartse blaastijd bepaald. Als de slag is afgelast, wordt het volgende horizontale blaasuur bepaald. Voor de eerste 10 minuten wordt het schommelen uitgevoerd in tabel G~H voor snelle koeling. Ook wordt na 10 minuten wanneer het verschil tussen ingestelde temperatuur en kamertemperatuur meer dan 35,6°F bedraagt, de schommeloperatie uitgevoerd in tabel D~H voor een grotere koeling. De airconditioner herhaalt de swing in verschillende cyclus als volgt.

spoelthermistor (°F) Downward blow time (seconde) Horizontale blaastijd (tweede)

A 59 of minder 2 23

B 59 to 63 5 20

C 63 to 64 8 17

D 64 to 68 11 14

E 68 to 70 14 11

F 70 to 72 17 8

G 72 to 75 20 5

H meer dan 75 23 2

Toon 5 meer labels / korte tekst op deze pagina
Horizontale vaan · Vrijgegeven · Plaatsing instellen · Koude luchtpreventie · Temperatuur van binnen
Page 39 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-2B20NA1 MXZ-3B MXZ-4B
Pagina 39 · klik om te vergroten
Pagina 39
Page 39 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-2B20NA1 MXZ-3B MXZ-4B
Page 40 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-2B20NA1 MXZ-3B MXZ-4B
Pagina 40 · klik om te vergroten
Pagina 40
Page 40 of the Mitsumi electronic Floppy Disk Drive (- U) user manual — MXZ-2B20NA1 MXZ-3B MXZ-4B

Vraag stellen over de Mitsumi electronic Floppy Disk Drive (- U)

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Mitsumi electronic Floppy Disk Drive (- U)