Part No. SP6549 Printed in Canada CAUTION READ ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLA TION. SA VE THIS OWNER’S MANUAL FOR FUTURE REFERENCE. Model No.
Safety Signal W ords DANGER: means if the safety information is not followed someone will be seriously injured or killed. WARNING: means if the safety information is not followed someone could be seriously injured or killed. CAUTION: means if the safety information is not followed someone may be injured.
Description MA 0950 Gallon Output/24 hrs 9.5 Capacity of Bottle 1.9 Gallons Capacity of Base 2.0 Gallons * Sq. Ft. Coverage 2000 Fan Speeds 3 Replacement Filter MAF-1 Power Light Y es Fill Light Y es Auto Humidistat Y es Auto Shut Off Y es Controls Rotary CUL Listed Y es V olts 120 A.
Carefully r emove the humidifier and all other contents from the carton. There is a black strip that contains six pads for the bottom of the humidifier . Remove each pad and place one on each of the six legs on the bottom of the base as shown, by the solid dots.
Location Instructions WARNING: For your own safety , do not use humidifier if any parts are damaged or missing. Step 1 Place humidifier on a flat level surface in an area of house wher e most humidity is needed, or one which would likely result in moist air being circulated thr oughout the house such as near a cold air return.
WARNING: T o reduce the risk of shock, always unplug humidifier before cleaning or servicing. WARNING: T o reduce the risk of fir e or shock hazard, do not pour or spill water into control or motor ar ea. If controls get wet, let them dry com- pletely and have unit checked by authorized service personnel before plugging in.
7 Position the water bottle back into the humidifier base to the right of the grille. The “Side Fill Cap” must be facing outward. When positioned pr operly , the plunger will open and water will flow into the base. The base will hold the entire contents of the water bottle.
Step 1 Be sure unit is full of water and plugged in. Step 2 Set the Speed Control to LOW ( ). Step 3 Set Humidity Control to a medium posi- tion (see diagram below) NOTE: Humidifier should operate with humidity control on the r ecommended medium setting.
WARNING: T o reduce the risk of shock or injury from moving parts, always unplug humidifier before removing or r eplacing any parts. CAUTION: T o help retard bacteria growth and keep maximum ef ficien- cy , the filter should be replaced at least once per season, or more often under hard water conditions.
5. Install a new filter (MAF-1) into the base. Coil the filter and position it between the uprights in the bottom of the base. The start and finish of the coil should be captured at the center of the base (see diagram) and the fil- ter should be resting on the floor of the base.
WARNING: T o reduce the risk of injury , fire or damage to humidifier , use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier . T o reduce the risk of scalds and damage to humidifier , never put hot water in humidifier .
Step 3 Bi-W eekly Maintenance Removing Scale 1. Fill the humidifier base with one 8 oz. cup of undiluted white vinegar . Let solution stay 20 minutes. 2. Clean all interior surfaces with a soft brush. Dampen a soft cloth with undiluted white vinegar and wipe out the base to remove scale.
T roubleshooting T rouble Power light not illuminated Unit will not run and Fill Light is not on. Note: Red power light is on. Unit will not cycle on and off. Unit will not shut off. Unit will not dry out completely . Bottle continues to empty . Unit is not emptying during use.
Repair Parts Parts List for MoistAir Humidifier Model No. MA 0950 0 14 SP6549 Manual 71235 7/12/05 3:17 PM Page 14.
Repair Parts Parts List for MoistAir Humidifier Model No. MA 0950 0 Always order by part number - Not by key number * Standard Har dware Item - May be purchased locally † Stock item - Purchase local.
© 2004 Emerson Part No. SP6549 Form No. SP6549 Printed in Canada 11/04 FOR TECHNICAL HELP , CALL (800) 654-3545 FROM USA OR (888) 744-4687 FROM CANADA (Please have complete model number) Emerson T ool Company For more information about MoistAir® humidifiers visit our website at www .
Een belangrijk punt na aankoop van elk apparaat MoistAir MA 0950 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen MoistAir MA 0950 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens MoistAir MA 0950 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding MoistAir MA 0950 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over MoistAir MA 0950 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van MoistAir MA 0950 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de MoistAir MA 0950 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met MoistAir MA 0950 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.