Gebruiksaanwijzing /service van het product CSDV40SLP van de fabrikant Monessen Hearth
Ga naar pagina of 44
.
2 58D6056 CSD V Se ries Direct V e nt Gas Sto ve .
58D6056 3 CSD V Se ries Direct V e nt Gas Sto ve 4. Never install the stove • in a recreational vehicle • where curtains, furniture, clothing, or other flam- mable objects are less than 42" from the front, top, or sides of the stove • in high traffic areas • in windy or drafty areas 5.
4 58D6056 CSD V Se ries Direct V e nt Gas Sto ve 15. This appliance, when installed, must be electrically grounde.
58D6056 5 CSD V Se ries Direct V e nt Gas Sto ve • This appliance has been certified for use with either natural or propane gas.
6 58D6056 CSD V Se ries Direct V e nt Gas Sto ve A B C 586056 CSDV dims .
58D6056 7 CSD V Se ries Direct V e nt Gas Sto ve Plan for the installation of your stove.
8 58D6056 CSD V Se ries Direct V e nt Gas Sto ve .
58D6056 9 CSD V Se ries Direct V e nt Gas Sto ve ON OFF A C B ST1 132 alcove clearances Figure 5 - Alco.
10 58D6056 CSD V Se ries Direct V e nt Gas Sto ve 1. Remove two (2) straps. Figure 6 2. Open plastic bag and slide to bottom of unit. Figure 7 3. Lift up on ash lip and pivot down to open control door . Figure 8 4. Lift up on front. Pivot bottom of front out.
58D6056 1 1 CSD V Se ries Direct V e nt Gas Sto ve .
12 58D6056 CSD V Se ries Direct V e nt Gas Sto ve There are two b.
58D6056 13 CSD V Se ries Direct V e nt Gas Sto ve V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
14 58D6056 CSD V Se ries Direct V e nt Gas Sto ve Outside Corner Inside Corner T ermination Clearances T ermination clearances for buildings with combustible and noncombustible exteriors.
58D6056 15 CSD V Se ries Direct V e nt Gas Sto ve 1. Determine the route your horizontal venting will take.
16 58D6056 CSD V Se ries Direct V e nt Gas Sto ve 9 Zx " (241 mm) 9 Zx " (241 mm) .
58D6056 17 CSD V Se ries Direct V e nt Gas Sto ve HOT H V ST1 139 Horizontal termination Figure 21 - Horizontal T ermination Configura.
18 58D6056 CSD V Se ries Direct V e nt Gas Sto ve HOT H 1 V 1 H V ST1 141 Horiz term 3 elbows Figure 23 - Horizontal T ermination Conf.
58D6056 19 CSD V Se ries Direct V e nt Gas Sto ve Drop a plumb line from the inside of the roof to the locat- ing hole in the ceiling. Mark the center point where the vent will penetrate the roof.
20 58D6056 CSD V Se ries Direct V e nt Gas Sto ve 3. Lower the support box through the hole in the roof until the bottom of the box extends at least 2" ( mm) below the ceiling. Figure 27. Align the support box vertically and horizontally using a level.
58D6056 21 CSD V Se ries Direct V e nt Gas Sto ve H V V 1 ST1 146 vert vent 2 elbows Install restrictor into 4" collar of stove or f i r s t v e nt s e c t i o n as shown.
22 58D6056 CSD V Se ries Direct V e nt Gas Sto ve Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace.
58D6056 23 CSD V Se ries Direct V e nt Gas Sto ve The gas line connection may be made using 1/2" rigid tubing or an approved flex connector .
24 58D6056 CSD V Se ries Direct V e nt Gas Sto ve 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal.
58D6056 25 CSD V Se ries Direct V e nt Gas Sto ve A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall.
26 58D6056 CSD V Se ries Direct V e nt Gas Sto ve — This unit is supplied with ceramic fiber logs.
58D6056 27 CSD V Se ries Direct V e nt Gas Sto ve Figure 38 1. Carefully remove logs from wrapping. 2. Open front door of firebox. 3. Place rear log (#1) on rear log pin.
28 58D6056 CSD V Se ries Direct V e nt Gas Sto ve Figure 40 1. Carefully remove logs from wrapping. 2. Open front door of firebox.
58D6056 29 CSD V Se ries Direct V e nt Gas Sto ve This appliance is equipped with a pilot which must be lit by hand while following these instructions exactly . BEFORE OPERA TING smell all around the appliance area for gas.
30 58D6056 CSD V Se ries Direct V e nt Gas Sto ve .
58D6056 31 CSD V Se ries Direct V e nt Gas Sto ve O F F P I L O T O N PILOT FP1937 control knob on The “ON/OFF” switch for the main burner can be found on the back right side of the stove.
32 58D6056 CSD V Se ries Direct V e nt Gas Sto ve The venturi of the burner is equipped with an air shutter .
58D6056 33 CSD V Se ries Direct V e nt Gas Sto ve Make sure the gas valve knob is in the “OFF” position. W ait at least five (5) minutes before start-ing maintenance. A qualified agency should examine the venting system annually .
34 58D6056 CSD V Se ries Direct V e nt Gas Sto ve .
58D6056 35 CSD V Se ries Direct V e nt Gas Sto ve .
36 58D6056 CSD V Se ries Direct V e nt Gas Sto ve 18 19 20 17 3 4 13 12 15 16 5 2 8 9 1 6 10 14 1 1 7 586056 CSDV20 parts .
58D6056 37 CSD V Se ries Direct V e nt Gas Sto ve 1. Burner Assembly 1 58D0250 58D0250 2.
38 58D6056 CSD V Se ries Direct V e nt Gas Sto ve 18 19 20 21 22 17 3 4 13 12 16 5 1 1 2 15 1 14 6 10 8 7 9 586056 CSDV30 parts .
58D6056 39 CSD V Se ries Direct V e nt Gas Sto ve 1. Burner Assembly 1 58D0150 58D0150 2.
40 58D6056 CSD V Se ries Direct V e nt Gas Sto ve 22 23 16 24 25 26 28 4 5 14 13 7 6 2 3 2 17 20 18 19 8 1 1 15 9 10 12 21 586056 CSDV40 parts .
58D6056 41 CSD V Se ries Direct V e nt Gas Sto ve 1. Burner Assembly 1 58D0368 58D0368 2.
42 58D6056 CSD V Se ries Direct V e nt Gas Sto ve This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
58D6056 43 CSD V Se ries Direct V e nt Gas Sto ve MHSC warrants its products to be free of defects in material and workmanship and backs each product with a Limited Lifetime W arranty . This warranty is to the original purchaser of a MHSC product and is not transferable.
149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com.
Een belangrijk punt na aankoop van elk apparaat Monessen Hearth CSDV40SLP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Monessen Hearth CSDV40SLP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Monessen Hearth CSDV40SLP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Monessen Hearth CSDV40SLP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Monessen Hearth CSDV40SLP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Monessen Hearth CSDV40SLP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Monessen Hearth CSDV40SLP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Monessen Hearth CSDV40SLP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.