1 W415-0381 / H / 12.07.07 W415-0381 / H / 12.07.07 $10.00.
2 W415-0381 / H / 12.07.07 20-22 FINISHING Door , Louvre & Panel Removal & Installation Grate Installation Log Placement / Glowing Embers V ermiculite Charcoal Embers Charcoal Lumps 22 OPTIONA.
3 W415-0381 / H / 12.07.07 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0381 / H / 12.07.07 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BGD42 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
5 W415-0381 / H / 12.07.07 FIGURE 1 INST ALLA TION O VERVIEW FIGURE 2.
6 W415-0381 / H / 12.07.07 A terminal shall not terminate dir ectly abov e a sidewalk or pav ed drivew ay which is loca ted between two single f amily dwellings and serves both dw ellings . Local codes or regula tions may requir e dif fer ent clearances .
7 W415-0381 / H / 12.07.07 MINIMUM AIR TERMINAL L OCA TION CLEARANCES 32 32 32 32 32 32 4 Using a soffit heat shield (W585-0096), or equivalent, the distance may be reduced to a minimum of 18”. It is recommended to maximize the distance to the vinyl clad soffits.
8 W415-0381 / H / 12.07.07 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum of 12" above grade.
9 W415-0381 / H / 12.07.07 VER TICAL TERMINA TION HORIZONT AL TERMINA TION vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertical.
10 W415-0381 / H / 12.07.07 ELBOW VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMIN A TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE6 .
11 W415-0381 / H / 12.07.07 V 1 HORIZONT AL TERMIN A TION See graph to determine the re- quired vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.
12 W415-0381 / H / 12.07.07 90° 90° V 1 H 1 H 2 V 2 45° 90° 45° VERTICAL TERMIN A TION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .
13 W415-0381 / H / 12.07.07 H 1 VERTICAL TERMIN A TION For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2:.
14 W415-0381 / H / 12.07.07 1. Determine the air terminal location, cut and frame 10 3/4" square openings in the ceiling and the roof to provide the minimum 1" clear- ance between the vent pipe and any combustible material. T ry to center the vent pipe location midway between two joist to prevent having to cut them.
15 W415-0381 / H / 12.07.07 DO NOT CLAMP THE FLEXIBLE LINER FIGURE 24b 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an al- ternate method suitable to the authority having jurisdiction or the optional roof support.
16 W415-0381 / H / 12.07.07 FIGURE 25 5. Remove nails from the shingles, above and to the sides of the chimney . Place the fl ashing over the air terminal connector leaving a min. 3/4” of the air terminal connector showing above the top of the fl ashing.
17 W415-0381 / H / 12.07.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. FIGURE 21. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
18 W415-0381 / H / 12.07.07 FIGURE 33 This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fi replace is equippe d with two 1/4" diameter holes located in the front left and right corners of the base.
19 W415-0381 / H / 12.07.07 FIGURE 34 FIGURES 36a-c TOP SLOT FINISHING MA TERIAL CORNER POST NAILING TA B A B C CENTRE HOLE NAILING TA B 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied.
20 W415-0381 / H / 12.07.07 MINIMUM MANTEL AND ENCLOSURE CLEARANCES FIGURES 37a FIGURES 37b Combustible mantel clearance can vary according to the mantel depth.
21 W415-0381 / H / 12.07.07 Remove the backing of the logo supplied and place on the glass view- ing door , as indicated. FIGURE 40 LOG O ½" ½" LOGO PLA CEMENT PORCELAIN REFLECTIVE P ANELS 1. Remove the upper louvres, and open the glass door .
22 W415-0381 / H / 12.07.07 FIGURE 44 FIGURE 48 FIGURE 49 FIGURE 45 FIGURE 50 INST ALLA TION T O BE DONE BY A QUALIFIED INST ALLER and must be electrically con- nected and grounded in ac- cordance with local codes. In the absence of local codes, use the current CSA C22.
23 W415-0381 / H / 12.07.07 Unplug the power cord from the receptacle. Connect all wires as shown. Attach and secure the sen- sor assembly bracket to the securing stud located next to the receptacle/ junction box at the bottom left of the unit using the lock washer and wing nut.
24 W415-0381 / H / 12.07.07 FIGURE 57 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports.
25 W415-0381 / H / 12.07.07 # P ART NO. DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE** 4 W010-0800 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0801 PROP ANE GAS PILOT .
26 W415-0381 / H / 12.07.07.
27 W415-0381 / H / 12.07.07 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button igniter . - check if the push button igniter needs tightening. - replace the wire if the wire insulation is broken or frayed.
28 W415-0381 / H / 12.07.07 White / grey film forms. Sulphur from fuel is being depos- ited on glass, logs or combustion chamber surfaces. - clean the glass with a recommended gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become permanently marked.
Een belangrijk punt na aankoop van elk apparaat Napoleon BGD42 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon BGD42 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon BGD42 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon BGD42 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon BGD42 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon BGD42 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon BGD42 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon BGD42 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.