1 W415-0223 / E / 03.05.09 W olf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada t (705)721-1212 t fax (705) 722-6031 www .napoleonreplaces.com t ask@napoleon.on.ca INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
2 W415-0223 / E / 03.05.09 Pg 2-4 INTRODUCTION W arranty General Instructions General Information Care of Glass & Plated Parts 5-7 INST ALLA TION Insert V ent Connection Chimney Connection W all S.
3 W415-0223 / E / 03.05.09 NAPOLEON gas fi replaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certi fi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0223 / E / 03.05.09 FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water col- umn for natural gas and 1 1 inches water column for propane.
5 W415-0223 / E / 03.05.09 36" 15 1 / 2 " 25" 10 9 / 16 " 5 ½" AIR INLET EXHAUST 4 15 / 16 " 15 1 / 2 " 11 5 / 8 " 7 3 / 8 " 3"Ø 44 7 / 8 " 3 SIDED BACKER PLATE ALUMINUM TRIM 44 7 / 8 " 36 1 / 2 " 4 SIDED BACKER PLATE ALUMINUM TRIM Provide adequate ventilation air .
6 W415-0223 / E / 03.05.09 2" OVERLAP EXHAUST SEALANT HI-TEMP INTAKE VENT CONNECTION ASSEMBLY Move the insert close to its fi nal position inside the wood- burning fi replace.
7 W415-0223 / E / 03.05.09 For ease of accessibility , an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fi replace insert to the wall switch / millivolt thermostat.
8 W415-0223 / E / 03.05.09 Positioning the logs improperly will cause fl ame impingement and carboning. PHAZER TM logs and glowing embers, exclusive to Napoleon Fireplaces, glow when exposed to direct fl ame and provide a unique and realistic glowing effect that is dif ferent in every installation.
9 W415-0223 / E / 03.05.09 The on-off switch is located behind the left side control door . Purge all gas lines with the glass door open. Assure that a continuous gas fl ow is at the burner before closing the door . Allow several minutes (5-15) for the fl ame to stabilize after ignition.
10 W415-0223 / E / 03.05.09 1. Turn of f the electrical power and the gas supply to the fi replace insert. 2. Remove the fi re viewing door . Remove the logs. 3. Detach the two screws from the back of the fi rebox and remove the panel, as illustrated.
11 W415-0223 / E / 03.05.09 A mirror will let you see the opening of the air shutter without removing the burner . Scribe a line along the venturi tube and air shutter cap. Open or close according to the original opening by us- ing the scribed line as your datum.
12 W415-0223 / E / 03.05.09 31* W690-0001 MILLIVOL T THERMOST A T 32* W660-0010 REMOTE CONTROL - ADV ANT AGE 32* W660-001 1 REMOTE CONTROL - ADV ANTAGE PLUS 33* GD660 REMOTE W ALL SWITCH C / W 20FT WI.
13 W415-0223 / E / 03.05.09 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0223 / E / 03.05.09 PILOT BURNER THERMOCOUPLE THERMOPILE Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engul fi ng the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot fl ame.
15 W415-0223 / E / 03.05.09 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion cham- ber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned.
16 W415-0223 / E / 03.05.09 Appliance Ser vice Histor y This heater must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name 43.
Een belangrijk punt na aankoop van elk apparaat Napoleon Fireplaces GDIZC-N (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon Fireplaces GDIZC-N heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon Fireplaces GDIZC-N vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon Fireplaces GDIZC-N leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon Fireplaces GDIZC-N krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon Fireplaces GDIZC-N bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon Fireplaces GDIZC-N kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon Fireplaces GDIZC-N . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.