Gebruiksaanwijzing /service van het product GVFS20P van de fabrikant Napoleon Fireplaces
Ga naar pagina of 16
1 W415-0559 / 02.15.06 W415-0559 / 02.07.06.
2 W415-0559 / 02.15.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone.
3 W415-0559 / 02.15.06 W ARNING • Under no cir cumstances should this heater be modified. • Pr ovide adequate v entila tion and combustion air . Pr ovide adequa te accessibility c learance f or servicing and oper ating the hea ter . Ne ver obstr uct the front opening of the heater .
4 W415-0559 / 02.15.06 NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
5 W415-0559 / 02.15.06 FOR YOUR SA TISF ACTION, THIS FIREPLACE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Maximum input is 23,000 BTU/hr for natural gas and propane.
6 W415-0559 / 02.15.06 MAINT AIN THESE MINIMUM CLEARANCES T O COMB USTIBLES: A. 4" B. 2" * C. 2" Pr ovide adequate v entilation and combustion air . Provide adequate accessibility clearance for servicing and operating the stove. Never obstruct the front opening of the stov e.
7 W415-0559 / 02.15.06 BL O WER INST ALLA TION GAS INST ALLA TION 1. Install rigid black pipe, or 1/2" type L copper tubing with a shut-off valve to the stove. 2. Seal and tighten the gas line securely to a fl ex connector . DO NOT KINK FLEXIBLE CONNECTOR.
8 W415-0559 / 02.15.06 FINISHING 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by remov- ing the screws from the brackets located in the upper inside corners.
9 W415-0559 / 02.15.06 3. Place the hole in the underside of log #3 onto the locating screw , on the right side of the burner . The bottom branch of log #3 sits infront of, and against, the right end of log #2.
10 W415-0559 / 02.15.06 • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour ’s phone. Follow the gas supplier ’s instructions. • If you cannot reach your gas supplier , call the fi re de- partment.
11 W415-0559 / 02.15.06 Air shutter adjustment must only be done by a qualifi ed gas installer! ADJUSTMENTS VENTURI ADJUSTMENT 1 . In order to properly clean the burner and pilot assembly , remove the logs exposing both assemblies.
12 W415-0559 / 02.15.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1.
13 W415-0559 / 02.15.06 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0559 / 02.15.06 Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
15 W415-0559 / 02.15.06 Pilot goes out while standing; Main burner is in ‘OFF’ position. Gas piping is undersized. - turn on all gas appliances and see if pilot fl ame fl utters, diminishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure.
16 W415-0559 / 02.15.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS NOTES.
Een belangrijk punt na aankoop van elk apparaat Napoleon Fireplaces GVFS20P (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Napoleon Fireplaces GVFS20P heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Napoleon Fireplaces GVFS20P vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Napoleon Fireplaces GVFS20P leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Napoleon Fireplaces GVFS20P krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Napoleon Fireplaces GVFS20P bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Napoleon Fireplaces GVFS20P kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Napoleon Fireplaces GVFS20P . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.