Gebruiksaanwijzing /service van het product TS100 van de fabrikant Niles
Ga naar pagina of 16
T ABLE-T OP INFRARED SENSOR TS100 B LENDING H IGH F IDELITY AND A RCHITECTURE ® INST ALLA TION & OPERA TION GUIDE TS100 DS00326ACN/TS100 11/26/03 11:58 AM Page 2.
Intr oduction The TS100 is a tabletop, infrar ed sensor designed for use with the Niles infrared extender systems. Installed in a remote room location, the TS100 receives the IR commands transmitted from your hand-held remote(s). The IR commands are carried via a category 5 cable to your A/V equipment in another room, and instantly “repeated”.
2 Featur es and Benefits The TS100 of fers a number of improvements over other table-top IR sensors. • Plasma-proof performance—allows placement of the TS100 near plasma displays. • CFL interference resistant—expands installation flexibility to areas with fluorescent lighting.
3 Installation Considerations Ty p e of Cable The TS100 connects to the Niles infrar ed main system unit or IRH610 sensor expansion hub with an individual home run of category 5 cable. When running wires inside walls, most states and municipalities in the U.
4 T ABLE - TO P I NFRARED R EMO TE SENSOR Niles IR flasher MSU250 TS100 IR sensor Power , IR data, and power status signal via category 5 wire Stereo r eceiver Figur e 2 Connecting the TS100 to a Niles MSU250 IR main system unit broadcasting a status feed back signal.
5 T ABLE - TO P I NFRARED R EMO TE SENSOR size of batteries used, and how many IR emitters the r emote has. For example, remotes that operate on two small AAA batteries and have only one IR emitter are generally not as strong as remotes that use the larger AA size batteries and have two emitters.
6 T ABLE - TO P I NFRARED R EMO TE SENSOR A voiding Interference TS100 is designed to work in most applications including plas - ma TV’ s and in areas where CFL lighting and indirect sunight are present. Y ou should avoid locating the TS100 near poten- tial sources of electrical or optical noise, such as light dimmers or low-voltage lights.
7 T ABLE - TO P I NFRARED R EMO TE SENSOR Installation Step by Step 1. The TS100 is a small free-standing box designed to sit on a shelf or other convenient surface. The unit can be mounted under a shelf using double-sided tape or V elcro ® (not supplied).
8 6. Insert each wire into the appropriate hole on the removable connector plug (Figure 6), and snap the locking tab down. To help you, the connector plug is keyed. Insert the smooth side of the connector plug into the smooth side of the sock- et. Don’t for ce the scalloped side of the connector plug into the smooth side of the socket (Figure 5).
9 T roubleshooting This manual contains instr uctions for the TS100 only . For spe- cific information on the adjustment and operation of your Niles infrared extender system, please refer to the instruction manual included with your Niles IR Main System Unit (MSU140, MSU250, MSU480 MSU440Z, IntelliControl).
1 0 T ABLE - TO P I NFRARED R EMO TE SENSOR Eliminating Optical feedback In some installations, two conditions combine to cr eate an optical feedback loop. Symptoms can include: poor range, intermittent operation or no operation. The conditions which sometimes combine to create a feed- back loop are: 1.
I f the TS100 does not work, and the LED “flickers” or remains solidly lit: Cover up the Sensor with a piece of cardboard (your hand will actually create electromagnetic interference under some conditions).
T ABLE - TO P I NFRARED R EMO TE SENSOR 1 2 “TECH NOTE” The feedback led can be disabled if it continues to flicker or visual feedback is not desired. Discrete on and off IR commands are available on the Niles T echnical support website for disabling the feedback led.
T ABLE - TO P I NFRARED R EMO TE SENSOR 13 Notes DS00326ACN/TS100 11/26/03 11:58 AM Page 15.
T ABLE - TO P I NFRARED R EMO TE SENSOR 1 4 Notes DS00326ACN/TS100 11/26/03 11:58 AM Page 16.
N il es A udio Corporation www .nilesaudio.com 1 233 1 S.W . 1 30 Street Miami, Florida, 33 1 86 T el: (305) 238-4373 Fax: (305) 238-0 1 85 ©2004 Niles Audio Corporation. All rights r eserved. Niles, the Niles logo, IntelliContr ol, IntelliPad and Blending High Fidelity and Architectur e are register ed trademarks of Niles Audio Corporation.
Een belangrijk punt na aankoop van elk apparaat Niles TS100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Niles TS100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Niles TS100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Niles TS100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Niles TS100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Niles TS100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Niles TS100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Niles TS100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.