Gebruiksaanwijzing /service van het product B5SM -090 van de fabrikant Nordyne
Ga naar pagina of 16
LIGHT COMMERCIAL AIR HANDLER Installation Instructions B5SM -090/120 SERIES Horizontal Application - Rear View Horizontal Application - Fr ont View V ertical Application Please read this information thor oughl y and become familiar with the capabilities and use of y our appliance before attempting to operate or maintain this unit.
2 Important Safety Information ....................................3 General Information ...................................................4 Bef ore Y ou Install this Unit .........................................4 Locating the Air Handler ..........
3 IMPORT ANT SAFETY INFORMA TION Saf ety markings are used frequently throughout this manual to designate a degree or le v el of seriousness and should not be ignored. W ARNING indicates a potentially hazardous situation that if not av oided, could result in personal injur y or death.
4 GENERAL INFORMA TION B5SM air handlers are shipped from the f actor y ready f or installation in a horizontal position. The units can be easily re- confi gured in the fi eld for v er tical applications.
5 AIR HANDLER INST ALLA TION P ackaging Remo v al Remov e the shipping crate and User’ s Manual from the equipment. T ake care not to damage the tubing connections when removing the crate .
6 • The B5SM-120 air handler has a dual circuit coil and the B5SM-090 has a single circuit coil. • The B5SM-120 air handler is charged through ser vice v alves on the end of the liquid tube f or each circuit. These must be remo ved bef ore brazing the line sets .
7 ELECTRICAL WIRING W ARNING: T o av oid risk of electrical shock , personal injury , or death, disconn ect all electrical power to the unit before per forming an y maintenance o r s e r v i c e . T h e u n i t m a y h a v e m o r e t h a n o n e electrical suppl y .
8 ST ARTUP AND ADJUSTMENTS Pre-Start Check List Prior to star t-up, complete the f ollo wing inspection: V erify the unit is lev el and condensate can drain. Check condensate drain line(s) f or proper slope and trap . V er ify the air handler is mounted securely .
9 Figure 3. Proper Belt T ension 1/4 inch 1 foot Pulley Alignment Inspect the pulley alignment betw een the motor sheav e and blo wer pulle y . If a misalignment occurs, adjust the location of the motor sheav e b y loosening the set-screw in the stationar y f ace of the motor sheav e.
10 13 5/8" 15 9/16" 17 11/16" 17 13/16" 4 3/16" 4 3/8" 5 11/16" 8 3/16" Air Flow Electrical Connections 2 7/32" 3/4" 1 1/4" 18 13/16" Supply.
11 Figure 5. B5SM Physical Dimensions f or V er tical Installations 23" Return Duct Opening 5 1/16" 53 1/4" Cabinet Height 53" Return Duct Opening 57" Filter Rack Frame 60 1/4.
12 Model Motor Sheave P osition External Static Pressures (Inches Water Column) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw B5SM- 090 (2HP) 60 Hz Fully Closed 4182 666 1.
13 SINGLE PHASE THREE PHASE G C W2 W1 O/B Y R G C W2 W1 O/B Y R L2 L1 G L3 L2 L1 G L1 L2 G FIELD SUPPL Y CONNECTIONS L1 L2 L3 G FIELD SUPPL Y CONNECTIONS L1 L2 T1 T2 L1 L2 T1 T2 L3 T3 208-230/460V 460 208-230 460 208 - 230 Electrical Configurations 1.
14 Figure 7. T ypical Air conditioner Thermostat Connections BLOWER MO TOR GND T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T/COOL THERMOST A T OUTDOOR SECTION FREEZEST A T SINGLE ST AGE HEA T/COOL.
15 Figure 8. T ypical Heat Pump Thermostat Connections BLOWER MO TER GND BLACK BLACK GREEN BRO WN T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T PUMP THERMOST A T OUTDOOR SECTION NO TE 1 NO TE 2 FR.
7090950 Specifi cations and illustrations subject to change without notice or incurring obligations. Printed in U.S .A. (01/10) Installed by: Date Installed: Maintenance T ask WM S A A A ir Filters Inspect, c lean or replace as required.
Een belangrijk punt na aankoop van elk apparaat Nordyne B5SM -090 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Nordyne B5SM -090 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Nordyne B5SM -090 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Nordyne B5SM -090 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Nordyne B5SM -090 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Nordyne B5SM -090 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Nordyne B5SM -090 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Nordyne B5SM -090 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.