Gebruiksaanwijzing /service van het product CN3440 van de fabrikant Omega
Ga naar pagina of 24
http://www .omega.com e-mail: info@omega.com omega.com ® ® U ser ’ s Guide CN3440 SERIES Universal T emperature & Pr ocess Contr ollers Installation Guide.
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 37 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal three (3) year product warranty to cover handling and shipping time.
1 CONTENTS 1 INTRODUCTION .................................. 2 2 PREPARATION .................................... 3 2.1 Checking the Code Number ......... 3 3 MECHANICAL INSTALLATION .......... 4 3.1 Siting .......................................... 4 3.
2 The instrument documentation is shown in Fig. 1.1. The Standard Manuals , including the specification sheet, are supplied with all instruments. The Modbus Supplement is supplied with instruments configured for Modbus Serial Communication.
3 2 PREP ARA TION 2.1 Checking the Code Number – Fig. 2.1 Fig. 2.1 Location of Code Number Label Code Number Label XXXX / X X X X X X X X.
4 3 MECHANICAL INST ALLA TION EC Directive 89/336/EEC In order to meet the requirements of the EC Directive 89/336/EEC for EMC regulations, this product must not be used in a non-industrial environment.
5 3 MECHANICAL INSTALLATION… 3.2 Mounting – Figs. 3.3 and 3.4 The instrument is designed for wall-/pipe-mounting – see Fig. 3.4. Overall dimensions are shown in Fig. 3.3. Dimensions in inches (mm) 2.68 (68) 8.43 (214) 9.13 (232) Fixing Centres 6.
6 4 ELECTRICAL INST ALLA TION Warning. Before making any connections, ensure that the power supply, any high voltage-operated control circuits and high common mode voltages are switched off. Note. • Always route signal leads and power cables separately, preferably in earthed metal conduit.
7 4 ELECTRICAL INSTALLATION… B – Isolated Output Types Fig. 4.2 Setting the Selector Links A – Input Types PL3 Position Feedback Input PL2 Remote Set Point Input PL1 Process V ariable Input PL2 .
8 …4 ELECTRICAL INSTALLATION 4.4 Cable Glands and Conduit Fixings 4.4.1 Cable Glands (IEC – 20mm) – Fig. 4.3 4.4.2 Conduit Adaptors (N. American – 0.5in) – Fig. 4.4 Warning. • Rigid conduit must NOT be fitted to the controller. • Controller adaptors must incorporate a face seal.
9 4 ELECTRICAL INSTALLATION… Fig. 4.5 Cable Glands 4.4.3 Cable Glands (N. American – 0.5in) – Fig. 4.5 Warning. • Controller glands must be fitted with a face seal. • Torque settings (hubs only) – 20ft. lbs minimum, 25ft. lbs. maximum. • Outer nuts – hand tight plus a half turn only.
10 …4 ELECTRICAL INSTALLATION Fig. 4.6 Terminal Block Identification 4.5 Connections Summary – Fig. 4.6 Information. Input impedances: Low voltage(mV) >10M Ω Voltage >10M Ω Current 10 Ω .
11 4 ELECTRICAL INSTALLATION… Table 4.1 Electrical Connections T erminal Number 1 2 3 N/O 4 C 5 N/C 6 N/O 7 C 8 N/C 9 N/O 10 C 11 N/C 12 13 14 15 16 17 18 Tx+ 19 Tx – 20 Common 21 Rx+ 22 Rx – 23.
12 4.6 Input Connections Make connections to each input, as shown in Figs 4.4 to 4.14, first removing any factory-fitted wire links not required. 4.6.1 Thermocouple (THC) Inputs – Fig. 4.7 Note. Automatic Cold Junction Compensation (ACJC) is active when an input is programmed for use with thermocouples.
13 & ^ % Remote Set Point & ^ % Remote Set Point Sleeved Link $ £ @ & ^ % Process V ariable Remote Set Point Sleeved Link Red White Fig. 4.8 3-lead Resistance Thermometer Input Connections Fig. 4.9 2-lead Resistance Thermometer Input Connections Fig.
14 4.7 Output Connections Make connections as shown in Figs 4.15 and 4.16. 4.8 Relay Connections – Fig. 4.17 For relay functions refer to the following table. A – Standard Feedback Slidewire Configuration B – Alternative Feedback Slidewire Configuration Note.
15 31 30 32 Logic Input 2 Manual Automatic Local Remote or Dual Fixed Dual Set P oint 2 Fixed Dual Set P oint 1 * Alarm Acknowledge * Leading 'edge-triggered' (minimum duration 200ms) 5V 0V .
16 4.11 P ower Supply Selection and A C Connections – Fig. 4.22 Fig. 4.22 Power Supply Selection and AC Connections … 4 ELECTRICAL INSTALLATION Information.
17 Power Supply 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 L N NO C NC NO C NC NO C NC 3rd + – 3rd + – Tx+ Tx – Common Rx+ Rx – + – Connection/T erminal Number Retransmis.
18 25 26 27 28 29 30 31 32 + – 3rd + – Connection/T erminal Number Control Output Position Feedback Input Common (Tick Box) Link Positions Analog Output Logic Output Logic Input 1 Logic Input 2 V .
19 NOTES.
20 … NOTES.
Servicing Nor th America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
M2954/0 7 0 2 TEMPERA TURE Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies W ire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, C.
Een belangrijk punt na aankoop van elk apparaat Omega CN3440 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega CN3440 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega CN3440 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega CN3440 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega CN3440 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega CN3440 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega CN3440 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega CN3440 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.