DRA-DCC-8 DIGIT AL TO 8 CURRENT LOOP CONVERTER User’s Guide http://www .omega.com e-mail: info@omega.com.
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM Customer Service: 1-800-622-2378 / 1-800-622-BESTSM Engineering Service: 1-800-872-9436 / 1-800-USA-WHENS M TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico and Latin America: T el: (95) 800-TC-OMEGASM F AX: (95) 203-359-7807 En Espanol: (95) 203 359-7803 e-mail: espanol@omega.
C o n t e n t s 1. MOUNTING INSTRUCTIONS 2. REPLACING FUSES 3. ASSEMBL Y 4. SUPPL Y VOL T AGE 5. MODES OF OPERA TION 5.1 0-20 or 4-20mA output current selection 5.2 Switch Settings 6. P ARALLEL CONTROL MODE 6.1 PLC Inter face 6.2 The "E" (ENABLE) T erminal 7.
1. MOUNTING INSTRUCTIONS 2 The DRA-DCC-8 is designed for standard DIN rail mounting. Place the unit on the upper par t of the mounting rail with the fastening tab facing down. Using a suitable flat screwdriver loosen the tab slightly and attach the unit to the rail.
3 The DRA-DCC-8 is powered by a DC power supply at a range of 15-32Vdc. In order to determine the minimum supply voltage, use the following equation: Vmin = 8 + Rload( Ω ) * 0.02 where: Vmin is the minimum required supply voltage. Rload( Ω ) is the maximum output load including the leads resistance.
4 Figure 2. SW5 MSB Self T est Mode * according to para #5.2 6. P ARALLEL CONTROL MODE * according to para #5.2 In the parallel control mode, the DRA-DCC-8 unit is controlled via a 15 bit bus. Three Address bits (A0-A3) select the proper current output channel and 12 Data bits (D0-D11) determine its value (A0 and D0 are MSB).
5 6.2 THE "E" (ENABLE) TERMINAL For E="1" the unit is enabled, which means that all input vectors are received and the output is updated. When E="0" the unit ignores any new input vector . The E terminal is recommended to be used as a strobe for parallel data which has a long setup time.
6 7.4.1 BAUD RA TE SELECT SW1 and SW2 select one out of four available baud rates. 300 BPS 4800 BPS 9600 BPS 19200 BPS OFF SW1 SW2 OFF ON OFF OFF ON ON ON 7.4.2 ID CODE Up to eight DRA-DCC-8s can be connected in a multidrop configuration. Switches SW3, SW4, and SW5 (MSB) set the ID code.
7 Note: If the value is omitted it will be treated as zero. Separators such as blanks or commas are not allowed. Example: Channel 4 in DRA-DCC-8 no. 7 has to receive the value of 981.
8 8.1 SELF TEST #1 (Communication Por ts T est) In order to test the serial communication por ts, this test mode converts the unit to a transponder for ASCII characters. Any transmitted character will be echoed to the host terminal. The host parameters should be set to: Baud rate : 4800, W ord length: 8 bits, Parity: even, Stop bit: 1 8.
9 11. DRA-DCC-8 CALIBRA TION Generally there is no need to calibrate the DRA-DCC-8 unit. However if calibration is required, the following steps should be carried out: T wo potentiometer trimmers, one for "Zero" and the other for "Span" are located on printed card 7040.
10 INPUTS: P ARALLEL INPUTS LOGIC LEVELS: DA T A HOLD TIME: MAXIMUM P ARALLEL INPUT RA TE: SERIAL COMMUNICA TION BAUD RA TES: P ARITY : STOP BIT : ST A TUS REPORT : MUL TIDROP CAP ABILITY : OUTPUTS: O.
RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBT AIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SER VICE DEP ARTMENT (IN ORDER TO A VOID PROCESSING DELA YS).
Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OMEGA…Of Course! TEMPERA TURE ⻬ Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies ⻬ W ire: .
Een belangrijk punt na aankoop van elk apparaat Omega DRA-DCC-8 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega DRA-DCC-8 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega DRA-DCC-8 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega DRA-DCC-8 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega DRA-DCC-8 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega DRA-DCC-8 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega DRA-DCC-8 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega DRA-DCC-8 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.