M4548-0607 omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide MADE IN Shop online at Manual and Installati on Instructions Four Zone T emperature Monitor a.
2 23 WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
http://{Device IP Address}/ltx_conf.html Click on the “Server Properties” button. Enter the Subnet Mask and/or Gateway Address and click “Update Set- tings” Be sure to enter the correct Subnet Mask and Gate way Address for the net- work the OMA-V520-DCP is on.
4 General purpose, dry contact input Wiring Diagram Alarm Relay Output Plug in Thermocouple Terminals 1234 K + K + K + K + Sensor 1 Sensor 2 Sensor 3 Sensor 4 K + K + K + K + K type thermocouples with integrated spade connectors 8 W atch the display and no te any messages present.
Temperature Monitor and Alarm will repeat the wa rning message. This warning message can be repeated up to 2 times by changing the pro- gramm ed value.
Accessing the Four Zone Temperat ure Monitor over the phone 1 From another phone line call the Four Zo ne Temperature Monitor and Alarm. The device will pick up after the progra m med number of rings (Default is 1). 2 To access all functions, enter the 4-digit "Full Access" PIN.
18 Sensor Reading Af ter Callouts If the Four Zone Temperature Monitor has called all programmed telephone numbers and not made contac t it will wait 20 minutes before attempting to callout again. Peri odically, the time before callouts resume will be displayed.
ming this sensor and return to step 1.b j) You will hear “ Enter numb er then press pound” k) Enter the value then press # . ► Use * to program a negative number (i.e. *20 = -20º ) ► Acceptable range is -999 to 999 l) You will hear the value y ou just entered (i.
16 1: ok 2: ok 3: n/c 4: n/c Sensor Present Sensor Present Sensor Not Detected Sensor Not Detected Start Up W hen starting up, the Four Zone Temperature Monitor checks each temperature sensor input to verify that a sensor is connected. If a sensor is connected and has a reading within range, “ok” will be printed next to that sensors label.
10 Accessing the Program Me nu From the Main Menu, press 3 ► The "Full Access" PIN will be reques ted if the "Ack nowledge Only" PIN w as entered initially. If the corr ect "Full Access" PIN is not entered, the Four Zone Temperature Monitor and Alarm will hang up.
Changing the Callout Delay Time W hen a r efrigerat or or fre ezer’s temp erature is ou t of rang e the Four Zo ne Temperature Monitor and Al arm will wait this progra mmable amount of time before making telephone alert calls.
12 other device. See the Frequently Ask ed Questions section for details. 1 From t he Program Menu, press 4 to set the number of rings 2 You will hear the programmed number of rings 3 You will hear “Press one to change.
Een belangrijk punt na aankoop van elk apparaat Omega Engineering Four Zone Temperature OMA-VM520 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega Engineering Four Zone Temperature OMA-VM520 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega Engineering Four Zone Temperature OMA-VM520 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega Engineering Four Zone Temperature OMA-VM520 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega Engineering Four Zone Temperature OMA-VM520 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega Engineering Four Zone Temperature OMA-VM520 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega Engineering Four Zone Temperature OMA-VM520 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega Engineering Four Zone Temperature OMA-VM520 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.