Gebruiksaanwijzing /service van het product OMG-COMM8-A van de fabrikant Omega Engineering
Ga naar pagina of 22
Contents I NTRODUCTION ..................................................................... 1 O VERVIEW ................................................................................. 1 W HAT ’ S I NCLUDED ........................................
A PPENDIX E - 3421 A DDENDUM .......................................... 17 A PPENDIX F - S ILK -S CREEN .................................................. 1 A PPENDIX G - C OMPLIANCE N OTICES ................................ 19 F EDERAL C OMMUNICATIONS C OMMISSION S TATEMENT .
Introduction Omega Engineering OMG-COMM8-A Page 1 Introduction Overview The Omega Engineering OMG-COMM8-A provides the PC with eight RS -232 asynchronous ports. The OMG-COMM8-A allows for connection to any device utilizing the RS -232 electrical interface, such as modems, data -entry terminals, and plotters.
Introduction Omega Engineering OMG-COMM8-A Page 2 To install the OMG-COMM8-A using factory default settings, refer to the Installation section of this manual.
Card Setup Omega Engineering OMG-COMM8-A Page 3 Card Setup The OMG-COMM8-A contains several jumper straps that must be set for proper operation. Address Selection The OMG-COMM8-A occupies 64 I/O locations and can be addressed two different ways.
Card Setup Omega Engineering OMG-COMM8-A Page 4 The following illustration shows the correlation between the DIP-switch setting and the address bits used to determine the base address. In the example below, address 280 (Factory Default) is selected as a base.
Card Setup Omega Engineering OMG-COMM8-A Page 5 IRQ Selection The OMG-COMM8-A has an interrupt selection jumper that corresponds to each port that may have to be set prior to use. The software you are using with the board will determine which interrupts, if any are to be used.
Card Setup Omega Engineering OMG-COMM8-A Page 6 Interrupt Mode Options The OMG-COMM8-A will allow each port to have an independent interrupt level or share an interrupt with another port on the adapter. The OMG-COMM8-A will even share interrupts with a compatible port that is located on another adapter.
Card Setup Omega Engineering OMG-COMM8-A Page 7 Set jumpers to “ S ” for shared interrupt mode on all blocks sharing an IRQ except one. Set that port block for “ M ”. This provides the pull-down resistor circuit that makes sharing of IRQ possible.
Installation Omega Engineering OMG-COMM8-A Page 8 Installation The OMG-COMM8-A can be installed in any of the full size PC expansion slots, but to access the “AT” or (E )ISA IRQs (10, 11, 12, 15) it must be installed in one of the 16 bit slots.
Technical Descri ption Omega Engineering OMG-COMM8-A Page 9 Technical Description The Sealevel OMG-COMM8-A provides 8 additional serial ports for terminals, modems, printers, etc. The OMG-COMM8-A utilizes the 16550 UART chip. This chip features programmable baud rate, data format, interrupt control and a 16 byte FIFO.
Technical Descri ption Omega Engineering OMG-COMM8-A Page 10 DB-25 Connector Pin Assignments Signal Name Pin # Mode GND Ground 7 TD Transmit Data 2 Output RTS Request To Send 4 Output DTR Data Termina.
Specifications Omega Engineering OMG-COMM8-A Page 11 Specifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F ) -20º to 70º C (-4º to 158º F) Humidity Range 10 to 90% R.H. Non -Condensing 10 to 90% R.
Appendix A - Troubleshooting Omega Engineering OMG-COMM8-A Page 12 Appendix A - Troubleshooting A Serial Utility Diskette is supplied with the Omega Engineering adapter and will be used in the troubleshooting procedures.
Appendix A - Troubleshooting Omega Engineering OMG-COMM8-A Page 13 6. The following are known I/O conflicts: • The 278 and 378 settings may conflict with your printer I/O adapter.
Appendix B - How To Get Assistance Omega Engineering OMG-COMM8-A Page 14 Appendix B - How To Get Assistance Please refer to Appendix A - Troubleshooting prior to calling Technical Support. 1. Read this manual thoroughly before attempting to install the adapter in your system.
Appendix C - Electrical Interface Omega Engineering OMG-COMM8-A Page 15 Appendix C - Electrical Interface RS -2 32 Quite possibly the most widely used communication standard is RS -232. This implementation has been defined and revised several times and is often referred to as RS -232-C/D/E or EIA/TIA -232-C/D/E.
Appendix D - Asynchronous Communications Omega Engineering OMG-COMM8-A Page 16 Appendix D - Asynchronous Communications Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character.
Appendix E – 3421 Addendum Omega Engineering OMG-COMM8-A Page 17 Appendix E - 3421 Addendum The OMG-COMM8-A can be equipped with a higher speed oscillator and the Startech 16C654 UART. This UART has a significantly larger FIFO (64 bytes as opposed to the 16 of the 16C554).
Appendix F - Silk-Screen Omega Engineering OMG-COMM8-A Page 18 Appendix F - Silk-Screen 4.2" 8.0" 3.9".
Appendix G - Compliance Notices Omega Engineering OMG-COMM8-A Page 19 Appendix G - Compliance Notices Federal Communications Commission Statement FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules.
Warranty Omega Engineering OMG-COMM8-A Page 20 Warranty Omega Engineering, Inc. warrants this product to be in good working order for a period of one year from the date of purchase.
Een belangrijk punt na aankoop van elk apparaat Omega Engineering OMG-COMM8-A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega Engineering OMG-COMM8-A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega Engineering OMG-COMM8-A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega Engineering OMG-COMM8-A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega Engineering OMG-COMM8-A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega Engineering OMG-COMM8-A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega Engineering OMG-COMM8-A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega Engineering OMG-COMM8-A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.