Gebruiksaanwijzing /service van het product USB-4761 van de fabrikant Omega Engineering
Ga naar pagina of 39
omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide USB-4761 8 Channel Relay/Isolated DI USB Data Acquisition Module Shop online at.
Servicing Nor th America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
USB-4761 8-channel Relay / Isolated DI USB Data Acquisition Module User Manua l.
Contents Chapter 1 Introduction ............ ............................... .......... 2 1.1 Features .... ......... ..... ...... ........ ......... ..... ............ ..... ......... ..... 2 1. 1 .1 Ro b us t Pr o tect io n ... .. .. ... .. .. .... .
Ta ble 3.1 :I/ O Co nne ct or Si gna l Description .. ............. 24 3.2.3 LED Indi ca tor Stat us Descripti on . ... ...... ..... .. ....... ...... .. 24 Table 3.2:LED Indicator Sta tus Descri ption . ... . ..... .... .. 24 3.3 Isolated Digital Input Connections.
1 2 Introduction This chapter will provide information on the features of the DAS module, a quick start guide for installation, and some brief information on software and accessories for the USB-4761 Module.
Chapter 1 Introductio n Thank you for buying the USB-4761 data acquisition modul e. The USB- 4761 is a powerful data acquisition (DAS) module for the USB port. It features a unique circuit design and complete functi ons for data acquisition and control.
1.1.1 Robust Pro tection The USB-4761 digital input channels feature a robust isolation protection for industrial, lab and machinery au tomatio n app l icat ions. It durabl y withstands voltage up to 2,500 VDC, preventing your host system from any incidental harms.
1.2 Applications • Industrial On/Of f control • Switch status sen sin g • Digi tal I/ O contr ol • Industrial and lab automation • SMT/PCB machinery • Semi-conductor machinery • PC-based Industrial Machinery • T esting & Measurement • Laboratory & Education • External relay driving 1.
Figure 1.1: Inst allati on Flow Chart 5 Chapte r 1.
1.4 Sof tware Overview OMEGA offers a rich set of DLL drivers, th ird-party driver support and application software to help fully exploit th e functions of your USB-4761 mo dul e: • Device Drivers (on the companion CD-ROM) 1.4.1 Programmi ng Choices for D A&C Module: Yo u may use the application software like the Device Dr iv ers.
1.5 Device Dri ver Progr amming This section will provide a roadmap to demons trate how to build an appli- cation from scratch using the Device Drivers with your favorite development tools such as V isual C++, V isual Basic.
1.5.2 Programming w ith Device Driv ers Functi on Library The Device Drivers of fer a rich function library that can be utilized in various application programs. This functi on library consists of numerous APIs that support many development tools, such as V isual C++, V isual Basic.
2 2 Inst allation This chapter has a package item check- list, proper instructions about unpack- ing and step-by-step procedures for both driver and USB installati on.
Chapte r 2 Inst allation 2.1 Unp a cking After receiving your USB-4761 package, please inspect its contents first. The package should contain the foll owi n g item s: • USB-4761 Module • Shield ed USB 2.
2.2 Driver Inst allation W e recommend you install the software driver before you install the USB-4761 module into your system, sinc e this wil l g uarantee a smooth installation process. The 32-bit DLL driver Setup program for the USB-4761 module is included on the companion CD-ROM that is shipped with your module package.
St e p 3 : Click Continue , and sel ect th e Install ation option St e p 4 : Select the specific device and th en just fo ll ow th e ins talla tion instructions step by step to complete your device driver installati on and setup.
Figure 2.2: Device Nam e on the Device Manager Note : If your mod ule is pr oper ly in st al led, you sh ould see the device name of your module listed on th e Device Manage r ta b. I f yo u see you r d evice n ame listed, but mar ked with an exc lam at ion sign “!” , it mea ns you r mo dule ha s not be en co rr ectly inst al led.
Afte r your mo dule is properly installed with y our system, you can now configure your device using the Device Manager th a t has itself already been installed on your system during driver setup. A complete device installation pr ocedure should include device setup , configuration and testing .
St e p 2 : Yo u can view the device(s) alread y inst alled on your system (if any) in the Installed Devices list box. If you haven’t installed any devices, you might see a blank list.
Figure 2.5: The Device Setting Dial og Box Note : Pleas e r efe r to th e so ft war e ma n u al S tart/Pro gra ms/Omega U SB-4700 series/Device Driver’s Manual for the firmw are download util ity guidance and further info rmation.
2.5.1 T esting Digit al Input Func tion Click the Digit al In put tab to show the Digita l Input test panel as seen below . By the color of the LEDs, you can easily discern whether the sta - tus of each digital input channel is high or low . Figure 2.
. Figure 2. 7: Di git al Out put T ab in Device T est Dialog Only after your module device is properly s et up, configured and tested, can the device installation procedure be considered complete. After the device installation procedure is completed, you can safely proceed to the next chapter , Si gn al Connections .
St e p 2 : Right click the “Unplug or Eject Hardware” icon on your task bar . Figure 2. 8: Un plug or Eject Hardware Dialog St e p 3 : Select “USB471 1 Device” and press “S top” Button.
St e p 4 : Unplug your USB devi ce from the USB port. Note : Plea se mak e sur e that you ha ve clo se d t he app li cat ion prog rams bef ore unplu gging the US B device , otherwise some une xpecte d system erro rs or damage s may ha p- pen.
3 2 Signal Connections This chapter provides useful informa- tion on how to connect input and output signals to the USB-4761 via the I/O connectors.. Sections include: • Overview • I/O Connectors .
Chapter 3 Signal Connection s 3.1 Overview Maintaining good signal connections is one of the most important factor s in ensuring that your application system is sending and receiving data correctly . A good signal connection can avoid unnecessary and costly damage to your PC and other hardware devices.
Figure 3.1: I/O Connector Pin Assignment 23 Chapte r 3.
3.2.2 I/O Conne ctor Signal Descri ption T able 3.1: I/O Connector Signal Description Signal Name Description NO<0~ 7> Normal ly Open pin of re lay output COM<0~ 7> Common pi n of relay ou.
3. 3 Is ola ted Dig it al Input Connections 3.3.1 Single-ende d Channel Connections USB-4761 has 8 isol ated digital inpu t channels. Each of isolated digital input channel accepts 10~30 V DC voltage inputs, and accept bi-direc- tional input. It means that you can apply positive or negative voltage to an isolated input pin (V in ).
3.5 Fiel d Wirin g Consider ations • When you use USB-4761 to acquire data from outside, noises in the environment might significantly af fect the accuracy of your measure- ments if due cautions are not taken. The following measures will be helpful to reduce possible interference running signal wires between signal sources and the USB-4761.
A 2 S pecifications.
Appendix A Sp ecifications A.1 Isolat ed Digit al Input Channels 8 Optical Isolation 2,500 VDC Opto-isolator response time 25us Input V oltage VIH (max.) 30VD C VIH (min .) 5VDC VIL (max,) 2VDC Input current 5VDC 1.2mA 12VDC 3.3mA 24VDC 6.9mA 30VDC 8.
A.3 Ge n era l I/O Connector T ype Re movable 10 -p in sc rew te rm i na l x 5 Dimensions 132 X 80 X 32 mm (5.2” X 3.2” X 1.3”) Power Consumption 60mA@+5V typical, 400mA@+5V max.
USB-4761 User Manual 30.
B 2 Function Block.
Appendix B Function Block USB-4761 User Manual 32.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels.
Een belangrijk punt na aankoop van elk apparaat Omega Engineering USB-4761 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega Engineering USB-4761 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega Engineering USB-4761 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega Engineering USB-4761 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega Engineering USB-4761 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega Engineering USB-4761 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega Engineering USB-4761 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega Engineering USB-4761 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.