FPDM1000 SERIES Positive Displacement Mechanical Flowmeters.
.
Please read this information carefully befor e use! Before use, confirm the fluid to be used is compatible with the meter or consult with OMEGA for advice. To prevent damage fr om dirt or foreign matter , OMEGA recommends a Y or bas- ket type 60 mesh strainer be installed as close as possible to the inlet side of the meter .
1. OMEGA recommends that when set- ting up pipework for meter installations, a bypass line be included in the de- sign. This provides the facility for a meter to be removed for maintenance without interrupting production. (See Figure 1) 2 NOTE: Incorrect installation can cause pr e- mature wear of meter components 7.
3 OPERA TION SERVICE INSTRUCTIONS When fluid passes through the meter , the ro tors tur n. The gear located on top of one of the rotors drives the mechanical r egis- ters gear train which provides an accurate r eadout.
4 Check rotor operation by turning either of the rotors. If the r otors are not in mesh correctly or do not move fr eely , remove one of the rotors and r eplace it correctly at 90 degrees to the other r otor . Recheck the operation of the rotors. 4. Inspect the gears in the meter cap for wear .
5 Symptom Probable Cause Corrective Action FLUID WILL NOT 1. Foreign matter blocking Dismantle meter , clean rotors. Strainer must FLOW THROUGH rotors be fitted in-line. THE METER 2. Line strainer blocked Clean strainer . 3. Damaged rotors Replace rotors.
6 4 3 2 1 20 * 21 * 7 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 6 METER P ARTS LISTING Model: FPDM1004 Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS298N Meter Body 1/2 in. NPT (Aluminum) 11 MS337N Meter Body 1/2 in.
7 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 1 to 30 / 0.26 to 8 Below 5 centipoise 3 to 25 / 0.8 to 6.6 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.
8 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS188N Meter Body 1 in. NPT (Aluminum) 11 MS186N Meter Body 1 in. NPT (Stainless Steel) 11 MS188F Meter Body 1 in. ANSI 150 lb. Flange (Aluminum) 11 MS186F Meter Body 1 in.
9 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 6 to 120 / 1.6 to 32 Below 5 centipoise 10 to 100 / 2.6 to 26 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.
10 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS192N Meter Body 1 1 / 2 in. NPT (Aluminum) 11 MS190N Meter Body 1 1 / 2 in. NPT (Stainless Steel) 11 MS192F Meter Body 1 1 / 2 in. ANSI 150 lb.
11 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 10 to 250 / 2.6 to 66 Below 5 centipoise 15 to 235 / 4 to 62 Accuracy of Reading ± 1% Maximum Viscosity * 1000 C.
6 2 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 4 3 1 1 10 20 * * 7 5 12 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS520N Meter Body 2 in. NPT (Aluminum) 11 MS520-1N Meter Body 2 in.
13 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 15 to 350 / 3.96 to 92.46 Below 5 centipoise 30 to 300 / 7.93 to 79.
.
.
.
.
M- 4103/ 04 05.
Een belangrijk punt na aankoop van elk apparaat Omega FPDM1000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega FPDM1000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega FPDM1000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega FPDM1000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega FPDM1000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega FPDM1000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega FPDM1000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega FPDM1000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.