LP0694A omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at D D P P 6 6 3 3 0 0 0 0 0 0 A A -I I D D P P 6 6 3 3 0 0 0 0 0 0 B B -I I Digita .
OMEGAnet ® Online Ser vice omega.com Inter net e-mail info@omega.com Ser vicing North America: U.S.A.: One Omega Drive, P .O . Bo x 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.
3 z FOUR SELECT ABLE D.C. RANGES 200 µ A, 2 mA, 20 mA, 200 mA z MINIMUM AND MAXIMUM DISPLA Y CAPTURE z LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING z 0.
1. DISPLA Y : 5 digit LCD 0.48" (12.2 mm) high digits DP63000A-I : Reflective LCD with full viewing angle DP63000B-I : T ransmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module.
5 ADDING OPTION CARDS The DP63000 meters can be fitted with optional output cards and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below . The plug-in cards, that are sold separately , can be installed initially or at a later date.
WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter . All conductors should conform to the meter ’ s voltage and current ratings. All cabling should conform to appropriate standards of good installation, local codes and regulations.
7 4.3 INPUT WIRING CAUTION : Power input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the power input common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth ground potential.
8 5.0 R EVIEWING THE F RONT B UTTONS AND D ISPLAY PROGRAMMING MODE ENTR Y (SEL BUTT ON) It is recommended all programming changes be made off line, or before installation. The meter normally operates in the Display Mode. No parameters can be programmed in this mode.
9 6.1 MODULE 1 - S IGNAL I NPUT P ARAMETERS ( 1-INP ) P ARAMETER MENU ª « 0.02A rAN6E INPUT RANGE Select the input range that corresponds to the external signal. This selection should be high enough to avoid input signal overload but low enough for the desired input resolution.
Entering Code 66 will overwrite all user settings with the factory settings. The meter will display rESEt and then return to CodE 00 . Press the SEL button to exit the module.
11 The Security Code determines the programming mode and the accessibility of programming parameters. This code can be used along with the Program Mode Lock-out ( P-Loc ) in the User Input Function parameter (Module 1). T wo programming modes are available.
Enter the reset action of the output. See figure for details. Auto = Automatic action; This action allows the output to automatically reset off at the trigger points per the Setpoint Action shown in Setpoint Output Figures. The “on” output may be manually reset (of f) immediately by the front panel RST button or user input.
13 6.5 MODULE 5 - S ERIAL S ETUP P ARAMETERS ( 5 -S S E r ) The Serial Setup Parameters are only active when the optional RS232 or RS485 serial communications module is installed in the meter . Refer to the DP6-COM bulletin for complete details on DP63000 serial communications.
PROGRAMMING QUICK OVERVIEW Press and hold SEL button to enter Programming Mode..
W ARRANTY/DISCLAIMER OMEGA ENGINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Where Do I F ind Everything I Need for P rocess Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERA TURE ] Thermocouple, RTD & Thermistor Probes, Connectors, P anels &.
Een belangrijk punt na aankoop van elk apparaat Omega Vehicle Security DP63000A-I (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega Vehicle Security DP63000A-I heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega Vehicle Security DP63000A-I vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega Vehicle Security DP63000A-I leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega Vehicle Security DP63000A-I krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega Vehicle Security DP63000A-I bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega Vehicle Security DP63000A-I kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega Vehicle Security DP63000A-I . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.