NL
Oreck logo
Officiële handleiding

Oreck Orbiter (ORB557MC Series)

16 pagina's·993 KB·Schuurmachine·PDF·ENDEITJA
Oreck Orbiter (ORB557MC Series)
Inhoudsopgave 23 secties 53347-03 REV A · E N G L I S H · IMPORTANT SAFETY INSTRUCTIONS · BEFORE OPERATING CLEANER, READ ALL INSTRUCTIONS IN THIS · … TonenVerbergen
Page 1 of the Oreck Orbiter (ORB557MC Series) user manual — 53347-03 REV A
Pagina 1 · klik om te vergroten
Pagina 1
Oreck Orbiter (ORB557MC Series) — 53347-03 REV A diagram (page 1)
Afb. 1

53347-03 REV A

S I M P L Y A M A Z I N G

  • Includes:
  • Safety Warnings
  • Warranty
  • Operating Instructions
  • Trouble Diagnosis
  • Accessories
Page 2 of the Oreck Orbiter (ORB557MC Series) user manual — ALWAYS WEAR SHOES WHEN USING
Pagina 2 · klik om te vergroten
Pagina 2

E N G L I S H

IMPORTANT SAFETY INSTRUCTIONS

BEFORE OPERATING CLEANER, READ ALL INSTRUCTIONS IN THIS

When using an electrical appliance, basic precautions should always be followed, including the following:

MANUAL CAREFULLY.

READ ALL INSTRUCTIONS BEFORE

USING THIS FLOOR MACHINE

T able of C ontents

WARNING To reduce the risk of fire,

Maintenance & Customer Service, Important Safety Instructions page 2

electric shock, or injury:

  • Use indoors only.
  • Risk of explosion - Floor sanding can result in an explosive mixture of fine dust and air. Use floor sanding machine only in well ventilated area.
  • Do not allow to be used as a toy. Close attention is necessary when used by or near children.
  • Do not leave appliance unattended when plugged in. Unplug from outlet when not in use and before servicing.
  • Use only as described in this manual. Use only manufacturer’s recommended attachments.
  • Do not use with a damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center or call customer service .
  • Do not pull or carry by cord, use cord as a handle, close door on cord, or pull cord around sharp edges or corners. Keep cord away from heated surfaces.
  • Do not run cleaner over cord.
  • Do not use on stairs.
  • Connect to a properly grounded outlet only. See grounding instructions.
  • Unplug before installing or removing pads/cleaning brushes.
  • Warning - To reduce the risk of fire, use only commercially available floor cleaners and waxes intended for machine application.
  • Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
  • Do not handle plug or cleaner with wet hands.
  • Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair and anything that may reduce air flow.
  • Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.
  • Turn off all controls before unplugging.
  • Do not use appliance in an enclosed space where flammable, explosive or toxic vapors are given off by oil base paint, paint thinner, some mothproofing substances, or in an area where flammable dust is present.

Warranty, Operating Instructions page 3

Troubleshooting Guide, Accessories page 4

M aintenance & C ustomer S ervice

Your Oreck Orbiter is a product of precise engineering. The motor bearings are permanently lubricated and should not be oiled. If you require additional information or have problems with your Oreck Orbiter, you may call or write ORECK customer service.

Oreck Commercial Europe (for commercial units) 26 Mead Industrial Park River Way HARLOW Essex CM20 2SE Telephone: 01279 432653

Oreck UK (for residential units)

P.O.Box 107 Exeter Devon Telephone0845 603 0153

Please specify the model number and serial/code number which can be found on the data plate on the side of the Orbiter.

Save your sales or purchase slip. Should your Oreck appliance require warranty service, present this slip to the Authorized Service Center as your proof of purchase date.

SAVE THESE INSTRUCTIONS

CAUTION

This appliance must be connected to a grounded metal, permanent wiring system; or an equipment- grounding conductor must be run with the circuit conductors and connected to the equipment- grounding terminal or lead on the appliance.

ALWAYS UNPLUG THE MACHINE BEFORE INSTALLING OR REMOVING ACCESSORIES.

ALWAYS WEAR SHOES WHEN USING

ELECTRICAL EQUIPMENT.

or

Page 3 of the Oreck Orbiter (ORB557MC Series) user manual — Operating Instructions
Pagina 3 · klik om te vergroten
Pagina 3

E N G L I S H

To Attach Drive Pad Holder or Brush:

Oreck Orbiter (ORB557MC Series) — E N G L I S H diagram (page 3)
Afb. 2

Warranty

Lay the floor machine on its back with the handle lying on the floor. This exposes the brush holder pan. Place the brush or drive pad holder over the round brush holder pan making sure it is in place.

ORECK MANUFACTURING COMPANY: (Oreck 21180 Johnson Road; Long Beach, MS, USA 39560 gives you the following warranty for this product only if it was originally purchased for use, not resale from Oreck or an Oreck Authorized Retail Dealer.)

Oreck will repair or replace, free of charge, to the original purchaser, any part that is found to be defective in material or workmanship within one (1) year of the date of purchase. ORB555MC models carry a (5) five year limited motor warranty which applies to residential use. Note: If the unit is used commercially, a (1) one year overall warranty applies.

To Remove Brush:

Brushes, pads, drive blocks and other parts are subject to normal wear and are not covered by this warranty.

Lay machine on its back and pull brush or pad holder off the round holder pan.

This warranty does not apply to any part subjected to accident, abuse, alteration, misuse, damage caused by act of God, the use of voltages other than indicated on the serial number displayed on this product or service of this product by other than Oreck or a participating Factory Authorized Service Center.

To Use Machine:

The Orbiter's on-off switch is located on the handle. It has been designed to be conve- niently activated. On (I) - Off(O) is printed on the switch. BE CAREFUL that the switch is in the OFF (O) position before you plug the electric cord into the outlet. Before turning the machine on, be sure there is a pad or brush in place on the machine.

Oreck Orbiter (ORB557MC Series) — Warranty diagram (page 3)
Afb. 3 · Warranty

ON/OFF SWITCH

Oreck does not authorize any person or representative to assume or grant any other warranty obligation with the sale of this product.

Oreck’s warranty is valid only if you retain proof of purchase from Oreck or an Oreck Authorized Retail Dealer for this product. If you purchase this product from any other source, your purchase is “AS IS,” which means Oreck grants you no warranty, and that you, not Oreck, assume the entire risk of the quality and performance of this product, including the entire cost of any necessary servicing or repairs of any defects.

To Guide the Floor Machine:

Grasp the unique “T” handle and glide the machine across the floor in a back and forth motion. The patented “T” handle feature gives you complete control. The Orbiter's perfectly balanced counter-weight system gives smooth and easy action with fingertip control.

This warranty is in addition to your statutory and other legal rights.

Operating Instructions

® is the most advanced, easiest to use machine of its kind. With proper care and use, your Orbiter will last a lifetime. This booklet will tell you how to care for the Orbiter and all about its features, accessories and their use.

Care of your Oreck Floor Machine:

This is a precision machine. Dropping, unreasonable bumping or rough handling may result in damage to the balanced counter-weight system. Wrap your cord loosely around the two hooks on the handle. Remove brushes after use. The bristles may be damaged due to the weight of the machine. Store your machine in the upright position. After each use, remove wax or cleaning solutions. After sanding, blow sawdust off motor. Clean housing and bumper with damp cloth after each use. A little care will keep your Orbiter looking like new.

Your Orbiter floor machine comes completely assembled and ready to operate once the Drive Pad Holder or Brush is attached. The off/on switch has international symbols (O) OFF and ( l ) ON.

USER MAINTENANCE: Lubrication: The Orbiter motor bearings are factory lubricated and sealed. All other servicing should be performed by an authorized service center. There are no user serviceable parts inside.

To Replace the Fuse:

Oreck Orbiter (ORB557MC Series) — Operating Instructions diagram (page 3)
Afb. 4 · Operating Instructions

When changing fuse, replace with the same size fuse.

The Orbiter

Page 4 of the Oreck Orbiter (ORB557MC Series) user manual — SAND SCREENS
Pagina 4 · klik om te vergroten
Pagina 4

E N G L I S H

Troubleshooting Guide WARNING: Unplug cord from electrical outlet before servicing. WARNING: Unplug cord from electrical outlet before servicing. PPRROOBBLLEEMM PPOOSSSSIIBBLLEE SSOOUURRCCEE AARREEAASS TTOO CCHHEECCKK FLOOR MACHINE WILL NOT RUNNot plugged in properly. No electricity in wall outlet. Blown fuse/ tripped breaker Motor circuit breaker has tripped.Be sure cleaner is firmly plugged into wall outlet. Check electrical source–fuse or circuit breaker. Replace fuse/ Reset breaker Turn switch off and unplug cleaner. Check motor shaft for binding. Allow 30 minutes for motor to cool and system to reset. If unit is equipped with red reset button, press it. FLOOR MACHINE BOUNCESBrush or pad holder not properly in place. Using brush on dry surface without dry shampoo or wet shampoo.Place it properly. (See operating instructions.) Apply necessary shampoo dry or wet.

DRIVE PADS DRIVE PAD HOLDER (Black plastic with teeth) 53178-51-0327

FLOOR PADS

POLISHING PAD (White) 437051

SCRUB PAD (Brown) 437049

STRIP PAD (Black) 437071

BUFFING PAD (Red) 437055

CLEANING PAD (Green) 437056

For all floor pads, place either DRIVE PAD HOLDER or DRIVE PAD BRUSH on Orbiter. Then place the pad on the floor and center Orbiter onto the pad.

FLOOR BRUSHES

SHAMPOO BRUSH (Black bristle) 237049

Use with ORECK DRY SHAMPOO. This brush has specially cut bristles to provide safe, soft action needed for carpet cleaning.

POLISHING BRUSH - UNION MIX (Tan bristles) 237048

This polishing brush can be used to polish wood floors. This brush will “blend” in excess floor wax, maintain an even coat of wax and eliminate wax buildup.

SCRUB BRUSH (Orange bristles) 237047

This brush is used to clean ceramic and concrete and many tough stains.

GRIT BRUSH (Hard green/gray bristles) 237056

This is an extremely aggressive brush used to scour tough stains on concrete and asphalt.

All the floor brushes snap directly onto the Orbiter with no drive pad. Remove the brushes from the machine after use so as not to damage them.

Whenever calling, please be sure to have your model and serial number from data plate.

OTHER ACCESSORIES

A ccessories (Sold Separately)

LAMBS WOOL BONNET 437054

When choosing different pads and brushes for the Orbiter, there is no exact science to which pad or brush is most suitable on a particular floor. Pads are good for scrubbing and polishing flat surfaces. Brushes work well for getting into recesses in non-flat surfaces, like tile, where the bristles can get into grout lines. When you choose an accessory, remember - you want one aggressive enough to do the job but gentle enough not to damage the floor. Use common sense. For example, do not use a black pad (aggressive) on a wood floor (soft floor). Start with what is safe and move to more aggressive, if needed.

This bonnet is designed to provide the best possible shine on wood, tile and vinyl floors. To install bonnet, place over the DRIVE PAD HOLDER. Pull the drawstrings tight to prevent slipping. Tie a bow and tuck the excess string inside the bonnet. Use the bonnet for everyday buffing to remove scuff marks. When the bonnet becomes dirty, wash with soap and water, wring it out and place it back on the DRIVE PAD HOLDER to dry to its original shape.

WHITE TERRYCLOTH BONNET 437053

This bonnet cleans the traffic lane and spots in the carpet without wetting the entire carpet. When one side of bonnet is dirty, flip it over and use the other side. When bonnet is completely soiled, hose off and air dry.

The pads are color coded depending on how aggressive they are (except for the beige marble pad): White is the softest, followed by red, green, brown and black being the most aggressive. Pads are designed to be porous and open-weave (except the beige pad) so that when it loosens dirt it can pick it up. The dirt goes inside the pad (i.e. off the floor). All pads can be turned over and the other side used before cleaning and disposing. Pads may be hosed off in some instances and re-used. Brushes are also coded with black being the softest followed by the union mix (tan) brush, the orange scrub brush, with the brown grit brush being the most aggressive.

SAND SCREENS

The very best in floor sanding. For all sand screens, place either DRIVE PAD HOLDER or DRIVE PAD BRUSH on Orbiter. Then place the sand screen under any floor pad on floor and center Orbiter onto the pad. The SAND SCREEN comes in 60 grit (SS12060), 80 grit (SS12080) and 100 grit (SS12100).

Vraag stellen over de Oreck Orbiter (ORB557MC Series)

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Oreck Orbiter (ORB557MC Series)

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Oreck Orbiter (ORB557MC Series) handleiding-pdf

16 pagina's·993 KB·Schuurmachine·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…