Cheet ahSwitc h Workgroup -3726M Quick Installation Guide.
.
Quic k Installation Guide Cheet ahSwitch Workgroup-3726M Intelli gent/Stac kable Fast Et hernet Sw itch with 24 1 0BASE-T / 100BAS E-TX (RJ-45) Ports , and Option al Media Expan sion and Stack Modul e.
Accton is a tradema rk of Accto n T echnol ogy Corpo ration. Other tra demarks or brand na mes men tioned herein are trad emarks or registered tradema rks of thei r respect ive companie s. Internation al Headquarter s No. 1 Creatio n Road III, Science-based Industr ial Park Hsinchu 300, Taiwan, R.
Limited Wa rranty Accton T echnology Corporation Limited W arranty: Accton war rants all is produc ts to be free of manuf acturin g defects in workm ans hip and mat eri als , un der nor mal us e and ser vic e, for th e appl i cabl e w arra nty term.
Limited Wa rranty LIABLE UNDER THIS W ARRANTY IF ITS TESTING AND EXAMINA TION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR W AS CAUSED BY CUS T OMER'S OR ANY THIRD PER SON'S .
i Contents Introduction 1 Installing the Switch 2 Package Contents 2 Descripti on of Hardware 2 Mountin g the Switch 3 Stackin g Switches on a Flat Surface 3 Mountin g Switches in a Ra ck 4 Installi n.
Contents ii Canad a Departmen t of Communicati ons - Class A 16 BSMI Class A (Taiwan) 16 VCCI Cl ass A C omplianc e (Japan) 16 CE Mark Dec laration of Co nformance for EMI and Safety (EEC ) 17 Safety .
1 Introduction The Ch eetah Switch W orkgr oup-372 6M is perfec t for movi ng workgr oups f rom convent ional 10 Mbps E thernet to m ultiple-segm ent 100 Mb ps Fast Etherne t, and for consol idating your network equipment in to a single, cle an, efficient, an d super-fa st switch stac k.
Quick Installation Guide 2 Installing the Switch Before ins talling the switch ve rify that you have all the items listed under “Packa ge Contents.” If any of the item s are missin g or damaged , contact your local Accton distribut or . Also be s ure you hav e all the nece ssary tools an d cabling be fore installing the s witch.
Installing the Switch 3 The follow ing figure sho ws the c omponents of this switch sy stem: Mounting t he Switch This switc h can be pla ced directly on your deskt op, or moun ted in a rack.
Quick Installation Guide 4 Mounting Sw itches in a Rack Please co mply with th e following inst ructions t o ensure that your switch is securely mount ed in the rack. 1. Use a standard EI A 19-inch ra ck. 2. Use the br ackets and sc rews suppli ed in the rac k mo un ting ki t.
Installing the Switch 5 Y ou can i nstall a module as de scribe d below: 1. Disconn ect powe r to the switc h (the modu les ar e not hot-swappabl e). 2. Remove t he face plat e on the appropr iate slot by rem oving the t wo screws w ith a flat-hea d screw driver .
Quick Installation Guide 6 Connectin g the Swi tch System The Chee tahSwitch Workgro up-3726 M provides 24 RJ-45 ports on the base unit. Each of thes e ports suppo rts a connection to 10 Mbps Ether net or 100 Mb ps Fast Etherne t, and suppo rts full or half-dup lex operati on.
Installing the Switch 7 switch es break up the path for connec ted devi ces into separat e collision domains, you s hould not incl ude th e switch or connected cabling in your calculations for cascade length involving other devi ces.
Quick Installation Guide 8 1000BASE- SX and 1000B ASE-LX fiber optic ca ble depends on th e core size and the rating of the cable, as shown in the f ollowing tables. Powering On t he Switch 1. Plug the powe r cord i nto the powe r sock et on th e rear of the switch, and the other en d into a power outlet.
Installing the Switch 9 Verifying Por t Status Check e ach connec tion by vie wing the port indicator s on the base unit front panel. Their staus is sho wn in the fol lowing table. Verifying Syste m Operation V erify that th e stack has at least one Ma nageme nt Modu le cor rectly in stalled and operat ing.
Quick Installation Guide 10 • See if you r cable is func tioning prop erly by using i t for another port and attach ed device tha t displays valid indica tions wh en connect ed to the net work. • Be su re no tw isted-pai r cable e xceeds 1 00 met ers (328 feet).
Produc t Specificat ions 11 Product Specifications Base Unit Physical C harac teristics Access Method CSMA/CD S tandard s Conforma nce IEEE 802. 3, IEEE 802.
Quick Installation Guide 12 T e mperature Operating : 0~50 ° C / 32~122 °F S tor age: -40 ~70 °C / -4 0~158 ° F Humidit y 5% to 95% ( nonconde nsing) Certifica tion CE Mark Emissions FCC Class A, .
Troubleshoo ting 13 1000BASE-SX M odule (EM458 2-SX-SC) Access Method CSMA/CD S tandard s Conforma nce IEEE 802.3z Commu nication Rate 1000 M bps Commu nication Mode Full or half d uplex Media S uppor ted 50 /125 m icron o r 62.5 /125 mi cron mu ltimode fiber Output Power Minimu m: -9.
Quick Installation Guide 14 Power and Cooling Problems If the power indicato r does not turn on when the pow er cord is plugged in, you may have a prob lem with the power outlet , power cor d, or internal po wer suppl y as explaine d in the previou s secti on.
Port and Ca ble Assign ments 15 Port and Cable Assignments RJ-45 Por t Descrip tion RJ-4 5 sta tion port s (MDI-X) can be at tach ed to any dev ices th at use a standa rd netw ork interface ( e.g., a work station, serv er , bridge or router). RJ-45 daisy-c hain po rts (MDI) can be cascade d to a station po rt on similar network ing devic es (e.
Quick Installation Guide 16 EMI C ertifi cation FCC Class A Cer tification (USA) W arning: This equ ipmen t gene rates, use s, and can r adiate r adio freq uency energy and, if not in stalled and used i n accorda nce with the instructio n manual, may cause int erf erence t o radio com municat ions.
EMI Certification 17 CE Mark Declaration of Conformance for EMI and Safe ty (EEC) This information technology equipment com plies with the requirements of the Council Directive 89/336/EEC on the Appro.
Quick Installation Guide 18 Safety Compliance Warning: Fiber Opt ic Port S a fety When u sing a fiber op tic medi a expansion modul e, never look at the trans mit laser while it is powered o n. Also , never look directly at the fiber TX port and fiber cable ends w hen they are p owered on.
Safety Compliance 19 Wichtig e Sicherheit shinweis e (Germany) 1. Bitte lesen Sie diese Hinweise sorgfältig durc h. 2. Heben Sie diese Anlei tung für d en späteren Gebra uch auf. 3. V or jedem Reinigen ist da s Gerät vom S tromnetz z u trenn en. V erwenden S i e ke ine Flüss i gode r Ae rosolre iniger .
Quick Installation Guide 20 Optional Hardware Modules AC-ES3726 M-AGENT : SN MP/RMO N Manageme nt Module w ith RS-232 Port EM3582-FX -SC: Media M odule with 2 100BASE- FX (SC-type ) Ports EM4582 -SX-S.
.
AC-ES3726M E012002-R 01 F2.476 15020000 8100A.
Een belangrijk punt na aankoop van elk apparaat Accton Technology CheetaSwitch Workgroup-3726M (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Accton Technology CheetaSwitch Workgroup-3726M heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Accton Technology CheetaSwitch Workgroup-3726M vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Accton Technology CheetaSwitch Workgroup-3726M leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Accton Technology CheetaSwitch Workgroup-3726M krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Accton Technology CheetaSwitch Workgroup-3726M bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Accton Technology CheetaSwitch Workgroup-3726M kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Accton Technology CheetaSwitch Workgroup-3726M . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.