MAX ® 5410 Pro Series Owner’ s Manual AC VOLTS 0 150 METER LIGHT TRIGGER SWITCHED OUTLETS GROUND OK LINE FAULT UNSAFE VOLT AGE 1690 Corporate Circle, Petaluma, CA 94954 • www .
AC VOLTS 0 150 METER LIGHT TRIGGER SWITCHED OUTLETS GROUND OK LINE FAULT UNSAFE VOLT AGE Congratulations on your selection of the MAX ® 5410 as the AC power source for your audio/video system! Over 2.
1 Before Y ou Begin.........................................................1 Introduction.................................................................2 Connection Diagram....................................................3 Feature Overview......
2 INTRODUCTION • • • • • • A backlit analog voltmeter indicates the AC line voltage coming into your system. A combination ON/OFF/Dimmer switch controls the meter lighting. An always-on, convenience outlet on the front panel for temporary AC connections.
3 AUDIO VIDEO RECEIVER AMPLIFIER VCR SA TELLITE RECEIVER PVR (TiVo) TV CD PLA YER PROPERL Y GROUNDED AC OUTLET 12V TRIGGER IN OUT RS-232 USB LED LIGHT HIGH CURRENT OUTLETS SWITCHED OUTLETS AL WAYS ON .
Engineered in the USA Assembled in China 15A BREAKER GROUND IEC320 INLET HIGH CURRENT OUTLETS SWITCHED OUTLETS AL WA YS ON OUTLETS RS232 CONTROL USB LED LIGHT 12V TRIGGER IN OUT TRIGGER ENABLE TRIGGER DELAY HC OUTLETS DELAY SWITCHED OUTLETS DELAY LINE EQUIP .
5 FEA TURE DET AILS USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Front Panel Pushbutton This button controls the “High-Current” and “Switched” outlets.
FEA TURE DET AILS 6 Ground OK: Green LED. When this light is ON, it indicates that the wall outlet is properly wired. When the light is OFF , it indicates that the wall outlet has a reversed line and neutral wire, or that there is no ground present. Line Fault: Red LED.
7 FEA TURE DET AILS Filtered Outlet Banks Eight Outlets (4 banks / 2 outlets per bank) are fed through cascaded noise filtration circuits. These circuits are designed to eliminate AC contamination that is detrimental to the performance of audio or video components like stereo receivers, VCRs or televisions.
8 FEA TURE DET AILS Circuit Breaker A circuit breaker is located on the back panel of the MAX ® 5410. The circuit breaker will trip only if the total current draw exceeds the maximum current rating (15A). This means that collectively , all outlets must draw more than 15 Amps before the circuit breaker will trip.
Engineered in the USA Assembled in China UTLETS RS232 CONTROL USB LED LIGHT 12V TRIGGER IN OUT TRIGGER ENABLE TRIGGER DELAY HC OUTLETS DELAY SWITCHED OUTLETS DELAY LINE EQUIP.
10 FEA TURE DET AILS Protect or Disconnect™ AC Surge Protection When the MAX ® 5410 is subjected to a high voltage surge, its voltage output is limited to a safe level and the high levels of surge current are diverted away from the connected equipment.
11 TECHNICAL SPECIFICA TIONS Clamping Level..............................................................................................260V Capacitance......................................................................................30pf (approx.
My MAX ® 5410 power cable does not reach the wall outlet. Can I use an extension cord to make it reach? Y es, but you must use only Panamax extension cords to keep your warranty valid.
USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 13 MAX PRO-SERIES RS-232 COMMAND SPECIFICA TIONS Changes the front panel button status to ON. Initiates a power -on sequence if the previous state is OFF . Changes the front panel button status to OFF .
Een belangrijk punt na aankoop van elk apparaat Panamax MAX 5410 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Panamax MAX 5410 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Panamax MAX 5410 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Panamax MAX 5410 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Panamax MAX 5410 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Panamax MAX 5410 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Panamax MAX 5410 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Panamax MAX 5410 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.