NL
Panasonic logo
Officiële handleiding

Panasonic CS-E15CKP

95 pagina's·5.8 MB·Airconditioner·PDF·ENJA
Panasonic CS-E15CKP
Inhoudsopgave 65 secties BZ02 · OPERATING INSTRUCTIONS · I NVERTER M ODEL :- · RUSSIAN ...................... P. 82 – P. 93 · … TonenVerbergen
BZ02p.1OPERATING INSTRUCTIONSp.1I NVERTER M ODEL :-p.1RUSSIAN ...................... P. 82 – P. 93p.1ESPAÑOL ..................... P. 71 – P. 81p.1GREEK ......................... P. 61 – P. 70p.1ITALIANO ..................... P. 51 – P. 60p.1NEDERLAND................ P. 41 – P. 50p.1FRANÇAIS.................... P. 31 – P. 40p.1DEUTSCH ..................... P. 21 – P. 30p.1PORTUGUÊS ............... P. 11 – P. 20p.1ENGLISH ...................... P. 1 – P. 10p.1Room Air Conditionerp.1F563844p.1FEATURES Cool, quiet, comfort from Panasonic Inverter Aided air conditionerp.2IMPORTANTp.2! Warningp.2SAFETY PRECAUTIONSp.3! Cautionp.3I Installation Precautionsp.3I Operation Precautionsp.3I Accessories G Remote Controlp.4INVERTERp.4RESET BATTERY CLOCKp.4MODE SLEEP ECONOMYp.4TEMPp.4FAN ANp.4AUT AUT Op.4AUTOp.4HEA HEA Tp.41 Slide down the remote control cover completelyp.5RESETp.5CLOCKp.5AUTO MANUALp.5MODEp.5ECONOMY SLEp.5POWERFULp.5OFp.5I Remote Control – To set the current timep.61 Connect the power supply cord to an independent power supplyp.616 ° Cp.618 ° Cp.631 ° Cp.632 ° Cp.636 ° Cp.6H E A T I N Gp.6D R Yp.6S O F Tp.6C O O L I N Gp.6DBTp.7WBTp.7MODE POWERFULp.8RESET CLOCKp.8QUIETp.8CARE AND MAINTENANCEp.92 Remove the air filtersp.9I Pre-season Inspectionp.9ENERGY SAVING AND OPERATION HINTSp.10TROUBLESHOOTING Before calling your dealer, refer to the checklistp.11G Temporary operationp.11I When the Timer LED at indoor unit blinksp.11I Call the Dealer Immediatelyp.11H28p.11H27p.11H23p.11
Page 1 of the Panasonic CS-E15CKP user manual — F563844
Pagina 1 · klik om te vergroten
Pagina 1
Panasonic CS-E15CKP — BZ02 diagram (page 1)
Afb. 1

BZ02

Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference.

Panasonic CS-E15CKP — BZ02 diagram (page 1)
Afb. 2

Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference.

OPERATING INSTRUCTIONS

(RefrigerantR410A)

I NVERTER M ODEL :-

RUSSIAN P. 82 – P. 93

ESPAÑOL ..................... P. 71 – P. 81

GREEK ......................... P. 61 – P. 70

ITALIANO ..................... P. 51 – P. 60

NEDERLAND................ P. 41 – P. 50

FRANÇAIS.................... P. 31 – P. 40

DEUTSCH ..................... P. 21 – P. 30

PORTUGUÊS ............... P. 11 – P. 20

ENGLISH ...................... P. 1 – P. 10

Indoor Outdoor CS-E9CKP CU-E9CKP5 CS-E12CKP CU-E12CKP5 CS-E15CKP CU-E15CKP5

MATSUSHITA INDUSTRIAL CORP. SDN. BHD. LOT 2, PERSIARAN TENGKU AMPUAN, SECTION 21, SHAH ALAM INDUSTRIAL SITE, SELANGOR, MALAYSIA

Room Air Conditioner

F563844

Page 2 of the Panasonic CS-E15CKP user manual — IMPORTANT
Pagina 2 · klik om te vergroten
Pagina 2

CONTENTS:Features 1:Safety Precautions 2 I Installation Precautions I Operation Precautions :Name of Each Part 3~4 I Indoor Unit I Outdoor Unit I Accessories I Remote Control :Preparation Before Operation 5 I Indoor Unit I Remote Control :How to Operate 5~6:Setting the Timer 7:Convenience Operation 7 I Powerful Mode Operation I Quiet Mode Operation I Ionizer Mode Operation :Care and Maintenance 8 I Cleaning the Indoor Unit and Remote Control I Cleaning the Air Filter I Cleaning the Front Panel I Air Purifying Filters I Pre-season Inspection I When the Air Conditioner is Not Used for an Extended Period of Time I Recommended Inspection :Helpful information 9:Energy Saving and Operation Hints 9:Troubleshooting 10 I Call the Dealer Immediately

Thank you for purchasing our Panasonic Room Air Conditioner.

G Enviromental Friendly (For Refrigerant: R410A Model) Zero ozone depleting potential and low global warming potential by using R410A refrigerant.

G Auto Restart Control Restart the unit automatically after power failure. (Refer page 9)

G Triple Deodorizing Filter Absorb odours produced by wall paper, construction material and living environment. (Refer page 8)

G Catechin Air Purifying Filter Filter that can trap dust, tobacco smoke and tiny particles in the room. It can also prevent growth of bacteria and viruses trapped in this filter. (Refer page 8)

G Removable Front Panel For quick and easy cleaning. (washable) (Refer page 8)

G Powerful Mode Reaches the desired room temperature quickly. (Refer page 7)

G Ionizer Mode Produce negative ion for fresh air. (Refer page 7)

G Quiet Mode To provide quiet operation. (Refer page 7)

G Vertical / Horizontal Air Swing Auto swing for vertical and horizontal airflow direction. (Refer page 6)

G Automatic Operation Sense indoor temperature to select the optimum mode. (Refer page 5)

G Illuminating Button For your convenience to operate in the dark. (Refer page 4)

FEATURES Cool, quiet, comfort from Panasonic Inverter Aided air conditioner

The wire which is coloured brown must be connected to the terminal which is marked with letter L or coloured red.”

The wire which is coloured blue must be connected to the terminal which is marked with letter N or coloured black.

The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked by the letter E or by safety earth symbol ! or coloured green or green and yellow.

“As the colours of the wires in the main lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follow :

The wires in this main lead are coloured in accordance with the following code:

Replacement or installation of power plugs shall be performed by authorised/qualified personnel only.

Airborne noise. A-weighted sound pressure level of this appliance is less than 70dB (A) under the JIS C 9612 test conditions. Maximum cooling operation 1 m from the unit

DISCONNECT THE MAIN PLUG FROM THE SUPPLY SOCKET WHEN NOT IN USE, WHERE SUPPLY CONNECTION IS VIA MAIN PLUG.

1) If the supply cord is damaged or needed to be replaced, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. 2) Remove power plug or disconnect from the main before servicing this appliance. 3) Do not repair by yourself. In case of malfunction of this appliance, do not repair by yourself. Contact the sales dealer or service dealer for a repair. 4) Turn off the power (Isolation from main power supply). Pull off the power plug from the receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the equipment from the main power supply in case of an emergency. 5) The appliance is not intended for use by young children or infirm person without supervision. Young children should be supervised to ensure that they do not play with the appliance. ! Caution

Green and YellowEarth Blue : Neutral Brown : Live

IMPORTANT

! Warning

Page 3 of the Panasonic CS-E15CKP user manual — ! Warning
Pagina 3 · klik om te vergroten
Pagina 3

G The instructions to be followed are classified by the following symbols:

G Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follow:

G To prevent personal injury, injury to others and property damage, the following instructions must be followed.

Before operating, please read the following “Safety Precautions” carefully.

SAFETY PRECAUTIONS

These symbols (with a black background) denote actions that are COMPULSORY.

This symbol (with a white background) denotes an action that is PROHIBITED.

This sign warns of death or serious injury.

This sign warns of damage to property.

! Caution

! Warning

I Installation Precautions

G Do not install, remove and reinstall the unit by yourself. Improper installation will cause leakage, electric shock or fire. Please engage an authorized dealer or specialist for the installation work.

G Do not install the unit in a potentially explosive atmosphere. Gas leak near the unit could cause fire.

G This room air conditioner must be earthed. Improper grounding could cause electric shock. G Ensure that the drainage piping is connected properly. Otherwise, water will leak out.

! Warning

! Caution

I Operation Precautions

This sign warns of death or serious injury.

G Switch off the power supply if the unit is not used for a long period.

G Switch off the power supply before cleaning. G Ventilate the room regularly. G Pay attention as to whether the installation rack is damaged after long period of usage.

G Do not pull the cord to disconnect the plug. G Do not wash the unit with water. G Do not use for other purposes such as preservation. G Do not use any combustible equipment at airflow direction. G Do not sit or place anything on the outdoor unit.

G If abnormal condition (burnt smell, etc.) occurs, switch off and unplug the power supply.

G Plug in properly. G Use specified power cord.

G Do not share outlet. G Do not insert plug to operate the unit. Do not pull out plug to stop the unit. G Do not operate with wet hands. G Do not damage or modify the power cord. G Do not insert finger or other objects into the indoor or outdoor units. G Do not expose directly to cold air for a long period.

This sign warns of injury.

! Warning

! Caution

Page 4 of the Panasonic CS-E15CKP user manual — AUTO
Pagina 4 · klik om te vergroten
Pagina 4
Panasonic CS-E15CKP — I Accessories G Remote Control diagram (page 4)
Afb. 3 · I Accessories G Remote Control
  • 2 Power Monitor Lamps – ORANGE
  • Lights up from LOW to HIGH to show the compressor operating condition.
  • Light off when then compessor stops.

1 Auto Operation Button (when the front panel is opened)

Panasonic CS-E15CKP — I Accessories G Remote Control diagram (page 4)
Afb. 4 · I Accessories G Remote Control

G Indoor Unit (when the front panel is opened)

I Accessories G Remote Control

G Two RO3 (AAA) dry-cell batteries or equivalent

(Catechin Air Purifying Filter)

G Air Purifying Filter

G Remote Control Indication Sticker

G Remote Control Holder

INVERTER

RESET BATTERY CLOCK

Step 1 2 3

MODE SLEEP ECONOMY

Panasonic CS-E15CKP — MODE SLEEP ECONOMY diagram (page 4)
Afb. 5

TEMP

FAN AN

AUT AUT O

AUT AUTO DR DRYFAN AN COOL COOL

AUTO

AUT AUT O

HEA HEA T

+ · (Triple Deodorizing Filter)

Page 5 of the Panasonic CS-E15CKP user manual — RESET
Pagina 5 · klik om te vergroten
Pagina 5
Panasonic CS-E15CKP — 1 Slide down the remote control cover completely diagram (page 5)
Afb. 6 · 1 Slide down the remote control cover completely
  • G Notes for Remote Control.
  • Do not throw or drop.
  • Do not get it wet.
  • Certain type of fluorescent lamps may affect signal reception. Consult your dealer.
  • G Remote Control Signal.
  • Make sure it is not obstructed.
  • Maximum distance : 10 m.
  • Signal received sound. One short beep or one long beep.

AUT AUTOHEA HEAT DR DRYFAN AN COOL COOL

! Check Point To be used by the service technician only.

0 Reset Point (Press with fine-tipped object to clear the memory)

  • G Observe the following when replacing the batteries
  • Replace with new batteries of the same type.
  • Do not use rechargeable batteries (Ni-Cd).
  • Remove the batteries if the unit is not going to be used for a long period.

G About the batteries • Can be used for approximately one year.

2 Insert the batteries – Be sure the direction is correct – 12.00 at display - flashing • Set the current time (CLOCK) immediately to prevent battery exhaustion.

1 Slide down the remote control cover completely

G How to Insert the Batteries

RESET

CLOCK

AUTO MANUAL

MODE

ECONOMY SLE

POWERFUL

OF

Page 6 of the Panasonic CS-E15CKP user manual — H E A T I N G
Pagina 6 · klik om te vergroten
Pagina 6
Panasonic CS-E15CKP — I Remote Control – To set the current time diagram (page 6)
Afb. 7 · I Remote Control – To set the current time

1 Press 1. 2 Then press 2 to increase or decrease the time. 3 Press 1 again. Set time at display will light up.

I Remote Control – To set the current time

1 Connect the power supply cord to an independent power supply

Panasonic CS-E15CKP — I Remote Control – To set the current time diagram (page 6)
Afb. 8 · I Remote Control – To set the current time
  • I To start the operation
  • Press 1 .
  • POWER indicator (green) on the indoor unit will light up. (LED blinks when the room temperature is low at the start of heating or operation mode is selected during Automatic Operation.) The power monitor lamps light up to show the compressor operating condition.
  • To stop, press once more.

AUTO – Automatic Operation HEAT – Heating Operation COOL – Cooling Operation DRY – Soft Dry Operation FAN – Fan Operation

HEA HEAT DR DRYFAN AN COOL COOL

  • I Automatic Operation
  • At the start of the Automatic operation, Heating, Cooling or Soft Dry is automatically selected according to the outdoor temperature, indoor temperature and setting temperature.
  • The operation mode changes every half hour, when necessary.
  • I Setting Temperature
  • Press 3 to increase or decrease the temperature.
  • The temperature can be set between 16°C ~ 30°C. (Not adjustable during Fan Operation.)
  • Recommended temperature:
HEAT20°C ~ 24°C COOL : 26°C ~ 28°C DRY : Approx. room temperature

16 ° C

18 ° C

31 ° C

32 ° C

36 ° C

(Ex) Setting Temperature at 25°C

13°C 19°C 21°C 23°C 25°C

H E A T I N G

D R Y

S O F T

C O O L I N G

Room Temperature · Outdoor Temperature

Page 7 of the Panasonic CS-E15CKP user manual — DBT
Pagina 7 · klik om te vergroten
Pagina 7

G Louver adjustment range

* Five stages of adjustments can be made in this range.

AUTO

AUTO

AUTO

  • The adjustment range is different for each operation i.e. Heating, Cooling and Soft Dry. (Fig.at left)
  • The angle indicated on the remote control is different from that on the indoor unit.
  • The louver angle automatically changes to prevent condensation during Cooling and Soft Dry.
  • When operation stops, the louver automatically closes.
Horizontal Airflow DirectionIndoor Unit Remote ControlAUTO

G Use this air conditioner under the following conditions:

Minimum Temperature-Cooling (Minimum Temperature-Heating)

Maximum Temperature-Cooling (Maximum Temperature-Heating)

DBTDry Bulb Temp WBT: Wet Bulb Temp

AUTO

AUTO

DBT: Dry Bulb Temp WBT: Wet Bulb TempIndoor DBTWBTDBT Maximum Temperature-Cooling (Maximum Temperature-Heating)32 (30)23 (-)43 (24) Minimum Temperature-Cooling (Minimum Temperature-Heating)16 (2)11 (-)16 (-5)

DBT

WBT

DBT

WBT

  • FAN – FAN Operation
  • Circulates air throughout the room.
  • Purifies and deodorizes the air if the air purifying filter is used. Fan Operation is recommended during seasons in which neither Heating nor Cooling is used.
  • HEAT – Heating Operation
  • To warm up the room temperature upon your preference setting temperature.
  • Heat is obtained from outdoor air to warm up the room. When the outdoor ambient air temperature falls, the heating capacity of the unit might be reduced. We recommend that you use an additional heating device when the outdoor ambient air temperature is low.
  • DRY – Soft Dry Operation
  • Dehumidifies while maintaining the setting temperature. The Soft Dry Operation is recommended during the rainy season.
  • If the room temperature exceeds the setting temperature, operation switches to Cooling.
  • The fan speed is rather slow during Soft Dry Operation.
  • The humidity may not decrease when the indoor temperature is lower than the setting temperature on the remote control.
  • AUTO – Automatic Operation
  • Sense indoor temperature to select the optimum mode.
  • Temperature is not displayed on the remote control during AUTO operation.

COOL – Cooling Operation • To set the room temperature at your preference cooling comfort.

  • G Notes
  • If the unit is not going to be used for an extended period of time, turn off the main power supply. If it is left at the ON position, approximately 2.8 W of electricity will be used even if the indoor unit has been turned off with the remote control.
  • If operation is stopped, then restart immediately, the unit will resume operation only after 3 minutes.
Show 18 more labels / short text on this page
Heating · Cooling, Fan · About 60° · Soft Dry · About 30° · About 30° · Horizontal Airflow Direction · 32 (30) · 16 (2) · Indoor Outdoor · 11 (-) · 23 (-) · 16 (-5) · 43 (24) · Unit in °C · 11 (-6) · 26 (18) · G Operation Details
Page 8 of the Panasonic CS-E15CKP user manual — MODE POWERFUL
Pagina 8 · klik om te vergroten
Pagina 8
  • G Timer Mode Operation Details
  • When the ON-Timer is set, operation will start before the actual set time. This is to allow the room temperature to reach the setting temperature by the setting time. (Maximum of 35 minutes in advance).
  • Once the timer is set, operation will start and stop at the same time everyday.
  • The current time is not displayed when the timers are set.
  • When both timers are used together, the TIMER mode indicator on the indoor unit remains lit even when the operation is stopped by the OFF-TIMER.
  • I OFF-TIMER Operation To stop the air conditioner operation automatically.
  • Press 5 to set the operation.
  • Press 2 to increase or decrease the time.
  • Then press 3 .
  • To cancel this operation, press 4 .

MODE POWERFUL

RESET CLOCK

QUIET

OperationTemperatureFan Speed AutomaticHEAT3.5°C higherSlightly Stronger COOL2°C lower (For first 20 minutes) DRY1°C lower (For first 20 minutes)
Panasonic CS-E15CKP — MODE POWERFUL diagram (page 8)
Afb. 9
  • G Operation Details
  • Air conditioner ON: Provide negative ion during operation.
  • Air conditioner OFF: Provide negative ion with FAN operation.
  • If blinking, press 8 twice. If still blinking, please call service.
  • I Ionizer Mode Operation Produce negative ion for fresh air.
  • Press 8 . * Ion mode indicator on the indoor unit will light up.
  • To cancel this operation, press once more.

G Operation Details • Air flow sound will reduce during operation.

  • I Quiet Mode Operation To provide quiet operation.
  • Press 7 . * Quiet mode indicator on the indoor unit will light up.
  • To cancel this operation, press once more.
Page 9 of the Panasonic CS-E15CKP user manual — I Pre-season Inspection
Pagina 9 · klik om te vergroten
Pagina 9
  • I Cleaning the Front Panel (Must be removed before washing) 1 Raise the front panel higher than the horizontal and pull to remove it. 2 Gently wash with water and a sponge.
  • Do not press the front panel too hard when washing.
  • When use kitchen cleaning fluid (neutral detergent), rinse throughly.
  • Do not dry the front panel under direct sunlight. 3 To fix the front panel, raise the front panel horizontally, match the protruding portion on the indoor unit to the fulcrum and push into place.

I Cleaning the Air Filter (Recommendation:- If the unit is operated in a dusty environment, clean the filters every two weeks, continuous use of this dirty filters will reduce cooling or heating efficiency) 1 Remove dirt using a vacuum cleaner. 2 Wash back of the air filter with water. 3 If badly soiled, wash it with soap or a mild household detergent. 4 Let it dry and reinstall it. Be sure the “FRONT” mark is facing you. * Damaged air filter. Consult the nearest authorized dealer. Part No.: CWD001047. • Do not use benzene, thinner, scouring powder or clothes soaked in caustic chemical to clean the unit.

  • I Cleaning the Indoor Unit and Remote Control
  • Wipe gently with a soft, dry cloth.
  • Do not use water hotter than 40˚C or polishing fluid to clean the unit.

CARE AND MAINTENANCE

Protruding portion on indoor unit

  • If you operate the air conditioner with dirty filters:- – Air is not purified – Cooling capacity decreases – Foul odour is emitted
  • Recommended to change these filters every 3 years. Do not reuse damaged filters. Consult the nearest authorized dealer to purchase a new filter. Catechin Air Purifying Filter No.: CZ-SF70P Triple Deodorizing Filter No.: CZ-SFD72P
  • G Catechin Air Purifying Filter
  • The filter is coated with catechin to prevent growth of bacteria and viruses.
  • Reusable.
  • Vacuum and fit it back in place (Recommended : every 6 months)
  • G Triple Deodorizing Filter
  • Absorb odours produced by wall paper, construction material and living environment.
  • Reusable.
  • Vacuum, place under direct sunlight for 6 hours and fit it back in place. (Recommended : every 6 months)

I Air Purifying Filters

Raise the front panel

2 Remove the air filters

Catechin Air Purifying Filter

I Recommended Inspection • After used over several seasons, the unit will become dirty and thus decreases the unit’s performance. Depending on the operation conditions, a dirty unit may produce odour and dust may pollute dehumidification system. Therefore, a seasonal inspection is recommended in addition to regular cleaning. (Consult an authorized dealer).

I When the Air Conditioner is Not Used for an Extended Period of Time 1 To dry the internal parts of the indoor unit, operate the unit for 2 - 3 hours using:-

G Are the remote control batteries weak? If the remote control display appears weak, replace the batteries.

G Are the air intake or outlet vents of the indoor or outdoor units obstructed?

G Is the discharged air cold/warm? Operation is normal if 15 minutes after the start of operation, the difference between the air intake and outlet vents temperature is:-

I Pre-season Inspection

2 Turn off the power supply and unplug. Note: If the unit is not switched off by the remote control, it will start operating when you plug in (because the unit is equipped with Auto Restart Control). 3 Remove the remote control batteries.

COOL – 8°C or above HEAT – 14°C or above

Fulcrum · Triple Deodorizing Filter · FAN operation

Page 10 of the Panasonic CS-E15CKP user manual — ENERGY SAVING AND OPERATION HINTS
Pagina 10 · klik om te vergroten
Pagina 10
Panasonic CS-E15CKP — ENERGY SAVING AND OPERATION HINTS diagram (page 10)
Afb. 10
  • G Automatic Operation
  • If the remote control fails to function or has been misplaced, press the Auto Operation button to start the Automatic operation.
  • The Automatic operation will be activated immediately once the Auto operation button is pressed. However, temperature cannot be adjusted in this operation.
  • The power indicator on the indoor unit will blink until the operation mode is selected automatically.
  • To cancel this operation, press once more.

I Voltage fluctuation • The outdoor unit stops operation frequently due to a fluctuation in the voltage. Consult your dealer.

I Thunder and Lightning • This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may switch off the main power supply and unplug from power socket.

I Timer Setting • When power failure occurs, the timer setting will be cancelled. Once power is resumed, reset the timer.

  • I Auto Restart Control
  • If there is a power failure, operation will be automatically restarted under the previous operation mode and airflow direction when power is resumed. (When the operation is not stopped by remote control).
  • If you do not want the unit to restart automatically when power is resumed, switch off the power supply.
  • If you do not require Auto Restart Control, consult your dealer.
  • Auto Restart Control is not available when Timer Mode is set.
  • When the operation restarts, the outdoor unit will operate only after 3~4 minutes.

I Avoid Direct Sunlight • Keep curtains or drapes closed to avoid direct sunlight during cooling operation.

I Timer Mode • To prevent wastage of electricity, use Timer when going out.

I Outdoor Unit • Do not block the air outlet vents. Otherwise, it will lower the cooling or heating performance.

I Keep All Doors and Windows Closed • Otherwise, cooling or heating performance will be reduced and electricity cost is wasted.

  • I Air Filters and Air Purifying Filters
  • Clean the air filters every 2 weeks and the Air Purifying Filters every 6 months.
  • Dirty filters may reduces cooling or heating efficiency.
  • I Setting the Temperature
  • Approximately 10% of electricity can be saved.
  • Set the temperature higher or lower than the desired temperature.

Here are some useful tips for optimum performance and cost-effective operation.

ENERGY SAVING AND OPERATION HINTS

Cooling Operation1°C higher Heating Operation : 2°C lower
Page 11 of the Panasonic CS-E15CKP user manual — I Call the Dealer Immediately
Pagina 11 · klik om te vergroten
Pagina 11

TROUBLESHOOTING Before calling your dealer, refer to the checklist

  • The outdoor unit gives off water and steam
  • There is a noise
  • Fog is blowing out from the unit
  • Operation stops suddenly
  • Air is not discharged immediately
  • The unit does not receive remote control signals, or the remote control display is weak or non-existent
  • The unit does not cool or heat effectively
  • The unit does not operate
  • When defrosting, the frost melts and changes to water and steam.
  • A ‘passt’ sound is heard during defrosting or when the air conditioner operation has been stopped. This is caused by the refrigerant inside the air conditioner flowing in the opposite direction.
  • The air conditioner will expand or contract due to changes in temperature, causing a cracking sound.
  • The sound of water flowing is caused by the refrigerant flowing inside the unit.
  • This occurs when the airflow from the air conditioner cools the room.
  • At Heating (POWER LED blinks) When the outdoor temperature is low and humidity is high, frost accumulates on the outdoor unit. The POWER LED blinks when the unit is melting the frost. (Please wait as defrosting may take up to 10 minutes.)
  • At Cooling
  • Soft Dry (auto Fan Speed) The indoor fan repeatedly stops for 80 seconds and operates for 20 seconds to check the indoor temperature. Whenever the temperature reaches the setting temperature, operation starts again.
  • At Heating (POWER LED blinks) This is to prevent cold air from blowing out. Please wait.
  • At Cooling
  • Soft Dry (auto Fan Speed) Air will not be discharged for approximately 40 seconds. The unit is designed to prevent tobacco, cooking and body odors from being discharged together with the cool air.
  • Are the batteries weak?
  • Have the batteries been inserted with the e and r poles in the correct position?
  • Has the temperature been set correctly?
  • Are the air filters dirty?
  • Are the air intake or outlet vents blocked?
  • Are all the windows and doors closed? * Measure the temperature difference. Operation is normal if, 15 minutes after the start of operation, the temperature difference between the air intake and outlet vents is 8°C or above for cooling and 14°C or above for heating.
  • Has a circuit breaker been tripped or a fuse blown?
  • Is the power supply plug disconnected from the outlet?
  • Is the Timer being used correctly?
Characters allowing temporary operationPossible temporary operationsDescription of operation H23CoolingEmergency operation with limited functions. (The Timer LED continues to blink.) H27 H28Heating Cooling
1. Press the MODE button and select Heating or Cooling. 2. Press the operation OFF/ON button (‘beep!’ sound is heard). * Use this operation temporarily, until repairs can be made.

G Temporary operation

Characters allowing temporary operation

  • Depending on which 3 characters are displayed, temporary operation may be possible.

Press TIMER or button to identify the error code. Beep sound (4 times) will be heard for the correct error code shown. Turn off the power supply and remove the power supply plug. Inform the error code to an authorised dealer.

The Timer LED blinks indicating abnormality. Press the check button at remote control for 5 seconds, error code will be displayed.

I When the Timer LED at indoor unit blinks

  • If the following conditions occur, turn off and unplug the main power supply, and then call the dealer immediately.
  • Abnormal noise is heard during operation.
  • Water or foreign material gets into the remote control by mistake.
  • Water leak from the indoor unit.
  • Switches or buttons do not operate properly.
  • Circuit breaker trips or fuse blows frequently.
  • Power supply cord and plug become unusually warm.
  • A smell of burning is emitted.

I Call the Dealer Immediately

H28

H27

H23

Remote Control Display.

Emergency operation with limited functions. (The Timer LED continues to blink.)

Show 8 more labels / short text on this page
Problem? · Problem? · Reason · Possible temporary operations · Cooling · Heating · Cooling · Description of operation

Vraag stellen over de Panasonic CS-E15CKP

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Panasonic CS-E15CKP

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Panasonic CS-E15CKP handleiding-pdf

95 pagina's·5.8 MB·Airconditioner·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…