This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties.
This symbol denotes item that is PROHIBITTED from doing.

7. Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following methods. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited. i. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the
socket. ii. Power supply connection to a circuit breaker for the permanent connection. Use an approved circuit breaker for the permanent
connection. It must be a double pole switch with a minimum 3.5 mm contact gap.

2.1. CS-E9GFEW-2 CU-E9GFE-2

1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)


1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)


1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)

3.1. Indoor Unit




4.1. Outdoor Unit




5.1. CS-E9GFEW-2 CU-E9GFE-2 CS-E12GFEW-2 CU-E12GFE-2

Model Piping size Rated Length
Additional Refrigerant (g/m) Gas Liquid
Max. Elevation (m)
Min. Piping Length (m)
Max. Piping
If piping length is over rated length, additional refrigerant should be added as shown in the table.
(m) · Length (m)


Model Piping size Rated Length
Additional Refrigerant (g/m) Gas Liquid
Max. Elevation (m)
Min. Piping Length (m)
Max. Piping
If piping length is over rated length, additional refrigerant should be added as shown in the table.
(m) · Length (m)

6.1. Outdoor Unit




7.1. Outdoor Unit








8.1. Outdoor Unit
8.1.1. CU-E9GFE-2 CU-E12GFE-2 1. Remove the 3 screws of the Top Panel.


Fig. 13 2. Remove the 6 screws of the Front Panel.


Fig. 14 3. Remove the screw of the Terminal Board Cover. 4. Remove the Top Cover of the Control Board by 4 hooks.



8.1.2. CU-E18GFE-2 1. Remove the 4 screws of the Top Panel.






9.1. Operation Characteristics CS-E9GFEW-2 CU-E9GFE-2
























220V Outdoor Temp. (°C)
230V 30°C 35°C 40°C 46°C
240V TC SHC IP TC SHC IP TC SHC IP TC SHC IP
D.B. W.B. kW
17.0 2.48 2.13 0.52 2.32 2.05 0.56 2.16 1.97 0.60 1.96 1.88 0.65
19.0 2.50 0.57
19.5 2.72 2.23 0.53 2.55 2.15 0.57 2.37 2.06 0.61 2.15 1.97 0.66
22.0 2.96 2.31 0.54 2.77 2.22 0.58 2.58 2.13 0.62 2.34 2.03 0.67
220V Outdoor Temp. (°C)
230V 30°C 35°C 40°C 46°C
240V TC SHC IP TC SHC IP TC SHC IP TC SHC IP
D.B. W.B. kW
17.0 3.47 2.49 0.89 3.25 2.40 0.96 3.02 2.30 1.03 2.74 2.20 1.11
19.0 3.50 0.97
19.5 3.81 2.61 0.90 3.57 2.51 0.97 3.32 2.41 1.04 3.02 2.30 1.12
22.0 4.15 2.70 0.92 3.88 2.60 0.98 3.61 2.49 1.06 3.28 2.38 1.14
220V Outdoor Temp. (°C)
230V 30°C 35°C 40°C 46°C
240V TC SHC IP TC SHC IP TC SHC IP TC SHC IP
D.B. W.B. kW
17.0 4.96 3.26 1.44 4.64 3.14 1.54 4.32 3.01 1.65 3.92 2.87 1.78
19.0 5.00 1.56
19.5 5.45 3.41 1.45 5.10 3.28 1.56 4.74 3.15 1.67 4.31 3.01 1.80
22.0 5.92 3.53 1.47 5.55 3.40 1.58 5.16 3.26 1.70 4.69 3.11 1.83
Total Cooling Capacity (kW) Sensible Heat Capacity (kW) Input Power (kW)
Indoor 27°C/19°C Outdoor 35°C/24°C

10.1. Indoor Unit


REF. NO. PART NAME AND DESCRIPTION QTY. CS-E9GFEW-2 CS-E12GFEW-2 CS-E18GFEW-2 REMARKS
B1-7 FLARE NUT 1 CW1723546 ← ←
B2 FITTING SPRING / THERMISTOR 1 CW380120 ← ←
B5 FLARE NUT 1 CW119848J ← CW119849J
C1 TURBO FAN ASS'Y 1 CW1767414 ← ←
C2 AIR GUIDE PLATE ASS'Y 1 CW1767421 ← ←
C2-9 WIRE HARNESS ASS'Y (UPPER) 1 CW1767546 ← ←
C3-4 STEPPING MOTOR ASS'Y 1 CW1767591 ← ←
C3-5 SLEEVE BEARING 1 CW1767609 ← ←
C3-6 SHAFT (DAMPER) 1 CW1767616 ← ←
C3-7 WIRE HARNESS ASS'Y (LOWER) 1 CW1767623 ← ←
C4 LOCK NUT/ FAN BLADE 1 CW847002J ← ←
E1 SWITCH BOX 1 CW1767654 ← ←
E2 INDICATION LAMP COVER 1 CW1786561 ← ←
E3 MOUNTING PLATE, PRINTED CIRCUIT 1 CW1767678 ← ←
E5 SHIELD PLATE 1 CW1767692 ← ←
E6 SHIELD PLATE 1 CW1767700 ← ←
E7 SWITCH KNOB 1 CW0728803 ← ←
E8 PRINTED CIRCUIT ASS'Y (CONTROL) 1 CW1786617 CW1786624 CW1786631 O
E8-3 THERMISTOR (FOR COIL) 1 CW129970J ← ←
E9 WIRE HARNESS ASS'Y 1 CW1786648 ← ←
E10 PRINTED CIRCUIT ASS'Y (SERVICE) 1 CW1786794 ← ←
E12 WIRE CLAMP 1 CW0812847 ← ←
E13 PRINTED CIRCUIT ASS'Y (DISPLAY) 1 CW1786655 ← ←
E14 PRINTED CIRCUIT ASS'Y (SENSOR) 1 CW1767755 ← ←
E17 SHIELD PLATE ASS'Y 1 CW1767786 ← ←
E17-1 INSULATION SHEET 1 CW1767793 ← ←
E18 DC FAN MOTOR 1 CW1889408 ← ← O
E19 PAN HEAD TAPPING SCREW 2 CW111403J ← ←
E21 WASHER (FOR EARTH) 2 CW1786749 ← ←
F1 BOTTOM FRAME ASS'Y 1 CW1767818 ← ←
F1-3 THERMAL INSULATION ASS'Y 1 CW1786756 ← ←
F1-4 THERMAL INSULATION ASS'Y 1 CW1786763 ← ←
F2 BELL MOUTH ASS'Y 1 CW1767849 ← ←
F3 COVER, MOTOR 1 CW1767856 ← ←
F4 FRONT GRILLE ASS'Y 1 CW1767863 ← ←
F5 CONTROL PANEL ASS'Y 1 CW1786693 ← ←
F6 SUCTION GRILLE ASS'Y 1 CW1786718 ← ←
F6-1 KNOB (1) 2 CW1767933 ← ←
F6-2 KNOB (2) 1 CW1768013 ← ←
F6-3 KNOB (2) 1 CW1768020 ← ←
F6-4 STRING 1 CW1768037 ← ←
F7 WIRE CLAMP 1 CW1768044 ← ←
F8 CASING (UPPER) 1 CW1814790 ← ←
F9 CASING (RIGHT) 1 CW1768068 ← ←

REF. NO. PART NAME AND DESCRIPTION QTY. CS-E9GFEW-2 CS-E12GFEW-2 CS-E18GFEW-2 REMARKS
F11 FIXTURE, REF. PIPING 1 CW1768082 ← ←
F12 REINFORCE PLATE ASS'Y 1 CW1768099 ← ←
F13 THERMAL INSULATION ASS'Y 1 CW1768107 ← ←
K1 REMOTE CONTROL 1 CWA75C3096 ← ← O
K3 INSTALLATION PLATE 1 CW1768121 ← ←
K4 SCREW KIT 1 CW1786965 ← ←
K6 DRAIN HOSE ASS'Y 1 CW1768138 ← ←
K13 TAPE 1 CW1786871 ← ←
51 OPERATING INSTRUCTIONS 1 CWF566395 ← ←
52 INSTALLATION INSTRUCTIONS 1 CWF613483 ← ←
53 INSTALLATION INSTRUCTIONS 1 CWF613484 ← ←
(Note)



REF. NO. PART NAME AND DESCRIPTION QTY. CU-E9GFE-2 CU-E12GFE-2 REMARK
2 ANTI - VIBRATION BUSHING 3 CWH50077 ←
3 COMPRESSOR 1 5RS102XBC01 ← O
4 NUT - COMPRESSOR MOUNT 3 CWH56000J ←
5 SOUND PROOF MATERIAL 1 CWG302315 ←
6 SOUND PROOF MATERIAL 1 CWG302316 ←
7 FAN MOTOR BRACKET 1 CWD541030 ←
8 FAN MOTOR (AC 30W SINGLE) 1 CWA951553 CWA951542 O
9 SCREW - FAN MOTOR BRACKET 2 CWH551217 ←
10 SCREW - FAN MOTOR MOUNT 3 CWH55252J ←
12 NUT - PROPELLER FAN 1 CWH56053J ←
13 CONDENSER 1 CWB32C2446 ←
14 TUBE ASSY CO (CAP./CHK.VALVE) 1 CWT01C4201 CWT01C4202
15 HOLDER-COUPLING 1 CWH351023 ←
16 3 WAYS VALVE (GAS) 1 CWB011374 ← O
18 2-WAYS VALVE (LIQUID) 1 CWB021301 ← O
19 V-COIL COMPLETE 1 CWA43C2143J ← O
20 SOUND PROOF BOARD 1 CWH151172 ←
21 REACTOR 1 G0C193J00003 G0C193J00004
22 SENSOR COMPLETE 1 CWA50C2205 ←
24 TERMINAL BOARD ASSY 1 CWA28K1110J ←
25 ELECTRONIC CONTROLLER - MAIN 1 CWA73C3418R CWA73C3419R O
30 HOLDER SENSOR 1 CWH321023 ←
31 TERMINAL COVER 1 CWH171039A ←
32 NUT - TERMINAL COVER 1 CWH7080300J ←
33 CABINET SIDE PLATE CO. 1 CWE04C1116 ←
34 CABINET SIDE PLATE (L) 1 CWE041248A ←
35 HANDLE 1 CWE161010 ←
36 WIRE NET 1 CWD041111A ←
37 CABINET FRONT PLATE CO. 1 CWE06C1136 ←
38 CABINET TOP PLATE 1 CWE031014A ←
39 CONTROL BOARD COVER (TOP) 1 CWH131264 ←
41 CONTROL BOARD COVER CO. 1 CWH13C1064 ←
42 L-TUBE 1 CWH5850080 ←
43 PACKING - L.TUBE 1 CWB81012 ←
50 DISCHARGE MUFFLER 1 CWB121010 ←
51 CRANKCASE HEATER 1 CWA341044 ←
52 SOUND PROOF MATERIAL 1 CWG302314 ←
53 SOUND PROOF MATERIAL 1 CWG302317 ←
(Note)



REF. NO. PART NAME AND DESCRIPTION QTY. CU-E18GFE-2 REMARK
2 ANTI - VIBRATION BUSHING 3 CWH50077
3 COMPRESSOR 1 5CS130XAE04 O
4 NUT - COMPRESSOR MOUNT 3 CWH56000J
5 SOUND PROOF MATERIAL 1 CWG302302
6 FAN MOTOR BRACKET 1 CWD541054
7 FAN MOTOR 1 CWA981166J O
8 SCREW - FAN MOTOR BRACKET 2 CWH551198
9 SCREW - FAN MOTOR MOUNT 3 CWH551106J
10 PROPELLER FAN ASSY 1 CWH03K1016
11 NUT - PROPELLER FAN 1 CWH56053J
12 CONDENSER COMPLETE 1 CWB32C2451
14 TUBE ASSY COMPLETE (EXP. VALVE) 1 CWT023679
15 4 WAYS VALVE 1 CWB001026J O
16 STRAINER 1 CWB11094
18 HOLDER - COUPLING 1 CWH351056
19 3 WAYS VALVE (GAS) 1 CWB011361 O
20 2-WAYS VALVE (LIQUID) 1 CWB021292 O
22 SOUND PROOF BOARD 1 CWH151050
23 TERMINAL COVER 1 CWH171039A
24 NUT - TERMINAL COVER 1 CWH7080300J
25 SENSOR COMPLETE (COMP. TOP) 1 CWA50C2185
26 HOLDER SENSOR 1 CWH321023
27 V-COIL COMPLETE 1 CWA43C2168J O
28 V-COIL COMPLETE (EXPAND VALVE) 1 CWA43C2058J O
29 SENSOR COMPLETE (COMP. DISC.) 1 CWA50C2180
30 SENSOR COMPLETE 1 CWA50C2181
31 REACTOR 1 CWG0C203J00003
32 CONTROL BOARD CASING (SIDE) 1 CWH102273
33 TERMINAL BOARD ASSY 1 CWA28K1110J
34 FUSE HOLDERS 1 K3GB1PH00016
35 FUSE 1 K5D303BBA002
37 CONTROL BOARD CASING (BOTTOM) 1 CWH102282
38 ELECTRONIC CONTROLLER - MAIN 1 CWA73C3420R O
40 CONTROL BOARD CASING (TOP) 1 CWH131167
41 CABINET SIDE PLATE (LEFT) 1 CWE041255A
42 HANDLE 1 CWE161010
43 CABINET SIDE PLATE (RIGHT) 1 CWE041158A
44 HANDLE 2 CWE16000E
45 CABINET SIDE PLATE ASSY 1 CWE06K1043
46 WIRE NET 1 CWD041041A
47 CABINET TOP PLATE 1 CWE031031A
48 CONTROL BOARD COVER (BOTTOM) 1 CWH131168
49 CONTROL BOARD COVER (TOP) 1 CWH131169A
50 RECEIVER 1 CWB14011
53 ACCUMULATOR 1 CWB131024
56 DRAIN HOSE 1 CWH5850080
57 PACKING 1 CWB81012
58 SOUND PROOF MATERIAL 1 CWG302270
59 SOUND PROOF MATERIAL 1 CWG302300
60 CRANKCASE HEATER 1 CWA341039
[PHAAM] Printed in Malaysia
(Note)