1 FP0 Series Programmable Controllers 07/2007.
Con t ro l F PWIN Pro PLC Progr a mm i ng So f t w a r e c on f orm i ng t o IEC61131-3 2 F P0 – S up e r Co m p a c t P L C In c r e d i b l y Sm a l l , A l on e or Ev e n a s Mu l t i p l e Comb i n e d Un i t s A control unit a mere 25mm* in width.
3 E i t h e r 10 Po i n t s or t h e M a x i m u m o f 128 Po i n t s Y ou S a v e Th i s Mu c h Sp a c e ! The expansion unit can be attached easily without any cables.
4 F P0 CP U U n i t s A R i c h L i n e -Up o f Bo t h S i ng l e a nd Comb i n e d Un i t s Con t ro l un i t s A maximum of 3 expansion units can be added to the control unit. ( Combining relay output types and transistor output types is also possible.
5 Relay output type F P0 Exp a ns i on U n i t s Choos e t h e Numb e r o f I / O Po i n t s t o Su i t t h e App l i c a t i on Digital I/O units Analogue I/O units Thermocouple and RTD units Network.
6 F P0 – I m pr e ss i v e C a p a b ili t i e s H i gh Sp e c i f i c a t i ons f or Bo t h Sp e e d a nd C a p a c i t y 0.9µ s per basic instruction.
7 F P0 – I m pr e ss i v e C a p a b ili t i e s F P0 F un c t i ons Equipped with 2-axis independent positioning and high-speed counter for support of PWM output. Pu l s e ou t pu t f un c t i on The unit comes equipped with 2 channels for the output of up to 10kHz pulses (5kHz during 2-channel output).
8 F P0 Co m m un i c a t i on S e r i a l In t e r f a c e s a nd Mod e m Comp a t i b l e Progr a m m i ng i n t e r f a c e T O O L por t ( a l so f or c o m m un i c a t i on ) In MEWTOCOL-COM Slave mode, this port of fers access to the entire FP0 memory area.
9 F P0 Co m m un i c a t i on E a s i e r M a i n t e n a n c e Th a n Ev e r B e f or e M a i n t e n a n c e s a v i ng ■ Overwrite function in RUN mode It is possible to overwrite a program while the FP0 is running, such as during program debugging and startup adjustments.
10 F P0 P R O F IB U S D P S l a v e or R e m o t e I/ O U n i t F or Cos t E f f e c t i v e Con t ro l o f D i s t r i bu t e d F i e l d D e v i c e The FP0 DPS2 can operate either as a DP Slave module or as a remote I/O system to which different decentralised inputs and outputs can be connected.
1 1 F P0 S - L I N K U n i t C on n e c t s D i r e c t l y t o t h e S -L IN K f or R e d u c e d W i r i ng Wire-saving The use of wires is greatly reduced and the number of connecting ter- minal blocks is minimised, resulting in large reduction in cost, as well as waste generated during wiring.
12 F P0 ME W N ET - F U n i t N e t wor k i ng Un i t s The FP0 can be used as a slave station for MEWNET -F (remote I/O system) by adding I/O link unit. MEWNET -F is a reduced-wiring, remote I/O system that connects PLCs located separately and I/O slave stations with 2-core cabling.
13 An a l ogu e S i gn a l Pro c e ss i ng F P0 An a l ogu e Un i t s ■ Multimode A/D, D/A conversion ■ High resolution: 12-bit V oltage, current and temperature selectable ■ 2 analogue inputs (.
14 An a l ogu e S i gn a l Pro c e ss i ng F P0 An a l ogu e Un i t s Item Description Rated operating voltage Operating voltage range 24VDC 21.6 to 26.
15 F P0 Th e rmo c oup l e Inpu t Exp a ns i on U n i t s En a b l e H i gh Pr e c i s i on T e mp e r a t ur e Con t ro l a t Low Cos t The FP0-TC4 and FP0-TC8 thermocouple units are suitable for user-friendly temperature acquisition using standard thermocouples with high precision.
16 F P0 R T D Inpu t Exp a ns i on U n i t Us e r F r i e nd l y A c qu i s i t i on o f T e mp e r a t ur e s w i t h H i gh Pr e c i s i on Fea t ur e s FP0-RTD6 6 channels ■ The module can be easily installed in an existing system.
17 )TEM $ESCRIPTION 2ATEDOPERATINGV OLTAGE 6$# /PERATINGV OLTAGERANGE TO 6$# !LLOW ABLENOV OLTAGETIME POINTSPOINTSTYPE MSAT 6MSAT 6 POINTSPOINTS3,).
18 F P0 S e r i e s Sp e c i f i c a t i on T a b l e s *: Since the response time of X0 to X5 is very fast (for high-speed counter input), the FP0 happens to catch chattering noise as an input signal. T o prevent this, it is recommended that timer instruction should be included in the programme.
19 Con t ro l F P W I N Pro Progr a mm i ng A c c ord i ng t o t h e In t e rn a t i on a l S t a nd a rd IEC 61131-3 FPWIN Pro is the Panasonic programming software developed according to the international standard IEC 61 131-3 (for Windows 98, NT V4.
20 F P W e b- S e rv e r Progr a mm e / Op e r a t e t h e F P0 Us i ng a LAN or WAN N e t wor k The multifunctional FP W eb-Server provides users with the option of connecting the FP0 or any other FP Series PLC to the Internet/Intranet thus enabling bi-directional communication.
21 Con t ro l Co m m X , PC W A Y , O PC S e r v e r V i su a l i s a t i on So f t w a r e f or R e a dy M a d e or Cus t om i s e d So l u t i ons The connection in ActiveX technology . ■ Connects your Visual Basic application to Panasonic PLCs. ■ Gives you the possibility to easily develop highly customised control solutions.
22 Notes: • A power cable (order number AFP0581) is enclosed with the control unit and the relay output type expansion units (T ransistor output type upgrade units do not require a power cable). • T wo Phoenix terminals (9-pin) are needed with the relay output type terminal type.
23 F P0 An a l ogu e a nd N e t wor k i ng U n i t s Produ c t s a nd Ord e r Numb e rs Screw terminal type Order number: FP0-A80A 8 points Input 8 points Screw terminal type Order number: FP0-A21A 3 .
24 T e r m i n a l s c r e w d r i v e r N e c e ss ar y w h e n w i r i ng re l a y ou t pu t t yp e & t er m i n a l s (P ho e n i x ) . A tt a c h m e n t e x a m p l e W i r i ng t oo l s P a .
25 Progr a m m i ng T oo l s a nd Curr e n t Consu m p t i on L i s t Produ c t s a nd Ord e r Numb e rs Ver .2.6 Ver .2.6 © 1999-2006 Panasonic Electric Works Europe AG Made in Germany © 1999-2006 Panasonic Electric Works Europe AG Made in Germany Control FPWIN Pro English, German, French, Italian, Spanish, Japanese menu selectable.
26 F P0 S e r i e s Pow e r Supp l i e s ■ Small size: - FP0 power supply: 90 x 60 x 30.4mm - FP power supply: 1 15 x 75 x 42mm ■ Maximum output current: - FP0 power supply: 0.7A (24VDC) - FP power supply: 2.1A (24VDC) ■ Multiple voltage input: 85 to 265V AC ■ Optimal protection: overvoltage, overcurrent, overheating, etc.
27 F P0 Produ c t O v e r v i e w Ord e r Numb e rs Product Name Part Number 1. Control Units FP0-C10RS, 6 Inputs / 4 Outputs (p+n / Relay) FP0-C10RSA FP0-C10CRS, 6 Inputs / 4 Outputs (p+n / Relay), R.
16 G l ob a l N e t wor k S e r v i c e s G l ob a l N e t wor k S e r v i c e s G l ob a l N e t wor k S e r v i c e s C o p yr i g h t © 2 0 0 6 • Pr i n t e d i n G e r m a n y 4 09 3 e u e n 0 .
Een belangrijk punt na aankoop van elk apparaat Panasonic E8RS (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Panasonic E8RS heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Panasonic E8RS vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Panasonic E8RS leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Panasonic E8RS krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Panasonic E8RS bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Panasonic E8RS kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Panasonic E8RS . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.