Gebruiksaanwijzing /service van het product P7P55D van de fabrikant Asus
Ga naar pagina of 122
Motherboard P7P55D.
ii E4977 Second Edition August 2009 Copyright © 2009 ASUST eK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transm.
iii Contents Contents ...................................................................................................................... iii Notices ..................................................................................................
iv Contents 2.6 Onboard switch ........................................................................................ 2-24 2.7 Jumpers .................................................................................................... 2-25 2.8 Connectors .
v Contents 3.5.5 Intel(R) SpeedStep(TM) T ech .................................................. 3-15 3.5.6 Intel(R) T urboMode T ech .......................................................... 3-15 3.5.7 Xtreme Phase Full Power Mode ..................
vi Contents 3.9.2 AI NET 2 .................................................................................... 3-34 3.9.3 ASUS EZ Flash 2 ...................................................................... 3-34 3.9.4 Express Gate .................
vii Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received including interference that may cause undesired operation.
viii Safety information Electrical safety • T o prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. • When adding or removing devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected.
ix About this guide Th is u se r gu id e co nt ai ns t he in fo rm at io n yo u ne ed w he n in st al li ng a nd co n gu ri ng t he m ot he rb oa rd. How this guide is organized This guide contains the following parts: • Chapter 1: Product introduction This chapter describes the features of the motherboard and the new technology it supports.
x Conventions used in this guide T o ensure that you perform certain tasks properly , take note of the following symbols used throughout this manual. T ypography Bold text Indicates a menu or an item to select. Italic s Used to emphasize a word or a phrase.
xi P7P55D specications summary (continued on the next page) CPU LGA1 156 socket for Intel ® Core™ i7 Processors/ Core™ i5 processors Supports Intel ® T urbo Boost T echnology * Refer to www .
xii (continued on the next page) P7P55D specications summary ASUS Unique Features ASUS Hybrid Processor – ASUS T urboV EVO - Auto T uning, TurboV , and Turbo Key ASUS Hybrid Phase - T .
xiii *Specications are subject to change without notice. P7P55D specications summary Internal I/O Connectors 3 x USB connectors support additional 6 USB ports 1 x IDE connector 7 x SA T A connec.
xiv.
ASUS P7P55D 1-1 1.1 Welcome! Thank you for buying an ASUS ® P7P55D motherboard! The motherboard delivers a host of new features and latest technologies, making it another standout in the long line of.
1-2 Chapter 1: Product Introduction Chapter 1 1.3 Special features 1.3.1 Product highlights Green ASUS This motherboard and its packaging comply with the European Union’s Restriction on the use of Hazardous Substances (RoHS).
ASUS P7P55D 1-3 Chapter 1 1.3.2 ASUS Xtreme Design—Hybrid Processor T urboV EVO Ultimate O.C. Processor The ultimate O.C. processor satises every level of overclockers—from die-hard enthusiasts to beginners. Auto tuning intelligently pushes the system to the fastest clock speeds while maintaining stability .
1-4 Chapter 1: Product Introduction Chapter 1 1.3.5 ASUS Exclusive Features MemOK! Any Memory is A-OK! Memory compatibility is among the top concerns during computer upgrades.
ASUS P7P55D 1-5 Chapter 1 ASUS Crystal Sound This feature can enhance speech-centric applications like Skype, online game, video conference and recording.
1-6 Chapter 1: Product Introduction Chapter 1 ASUS MyLogo2™ This feature allows you to convert your favorite photo into a 256-color boot logo for a more colorful and vivid image on your screen. ASUS Multi-language BIOS The multi-language BIOS allows you to select the language of your choice from the available options.
ASUS P7P55D 2-1 2.1 Before you proceed T ake note of the following precautions before you install motherboard components or change any motherboard settings.
2-2 Chapter 2: Hardware information Chapter 2 2.2.1 Motherboard layout Refer to 2.8 Connectors for more information about rear panel connectors and internal connectors.
ASUS P7P55D 2-3 Chapter 2 2.2.2 Layout contents Connectors/Jumpers/Slots Page 1. A TX power connectors (24-pin EA TXPWR, 8-pin EA TX12V) 2-38 2. LGA1 156 CPU Socket 2-5 3.
2-4 Chapter 2: Hardware information Chapter 2 2.2.3 Placement direction When installing the motherboard, ensure that you place it into the chassis in the correct orientation. The edge with external ports goes to the rear part of the chassis as indicated in the image below .
ASUS P7P55D 2-5 Chapter 2 2.3 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA1 156 socket designed for the Intel ® Core™ i7 / Core™ i5 Processor . 2.3.1 Installing the CPU T o install a CPU: 1. Locate the CPU socket on the motherboard.
2-6 Chapter 2: Hardware information Chapter 2 3. Lift the load lever in the direction of the arrow until the load plate is completely lifted. Load plate 4.
ASUS P7P55D 2-7 Chapter 2 6. Apply some Thermal Interface Material to the exposed area of the CPU that the heatsink will be in contact with, ensuring that it is spread in an even thin layer . Some heatsinks come with pre- applied thermal paste. If so, skip this step.
2-8 Chapter 2: Hardware information Chapter 2 2.3.2 Installing the CPU heatsink and fan The Intel ® LGA1 156 processor requires a specially designed heatsink and fan assembly to ensure optimum thermal condition and performance. • When you buy a boxed Intel ® processor , the package includes the CPU fan and heatsink assembly .
ASUS P7P55D 2-9 Chapter 2 3. Connect the CPU fan cable to the connector on the motherboard labeled CPU_F AN. DO NOT forget to connect the CPU fan connector! Hardware monitoring errors can occur if you fail to plug this connector . 2.3.3 Uninstalling the CPU heatsink and fan T o uninstall the CPU heatsink and fan: 1.
2-10 Chapter 2: Hardware information Chapter 2 2.4 System memory 2.4.1 Overview The motherboard comes with four Double Data Rate 3 (DDR3) Dual Inline Memory Modules (DIMM) sockets. A DDR3 module has the same physical dimensions as a DDR2 DIMM but is notched differently to prevent installation on a DDR2 DIMM socket.
ASUS P7P55D 2-1 1 Chapter 2 2.4.2 Memory congurations Y ou may install 1GB, 2GB and 4GB unbuffered and non-ECC DDR3 DIMMs into the DIMM sockets. • The default memory operation frequency is dependent on its Serial Presence Detect (SPD), which is the standard way of accessing information from a memory module.
2-12 Chapter 2: Hardware information Chapter 2 P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1067MHz capability for CPU at 2.66, 2.8 and 2.93GHz P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1333MHz capability for CPU at 2.66, 2.8 and 2.
ASUS P7P55D 2-13 Chapter 2 P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1333MHz capability for CPU at 2.66, 2.8 and 2.93GHz (continued) V endor Part No. Size SS/ DS Chip Brand Chip NO. Timing Dimm(Bios) V oltage DI MM s oc ke t s up po rt ( Op ti on al ) A* B* C* Crucial CT25672BA1339.
2-14 Chapter 2: Hardware information Chapter 2 P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1600MHz capability for CPU at 2.66GHz V endor Part No.
ASUS P7P55D 2-15 Chapter 2 P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1600MHz capability for CPU at 2.8 and 2.93GHz V endor Part No. Size SS/ DS Chip Brand Chip NO.
2-16 Chapter 2: Hardware information Chapter 2 P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1800MHz capability for CPU at 2.66GHz P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1800MHz capability for CPU at 2.8 and 2.93GHz P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1625MHz capability for CPU at 2.
ASUS P7P55D 2-17 Chapter 2 P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1866MHz capability for CPU at 2.66GHz P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-1866MHz capability for CPU at 2.8 and 2.93GHz P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-2000MHz capability for CPU at 2.
2-18 Chapter 2: Hardware information Chapter 2 P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-2133MHz capability for CPU at 2.8 and 2.93GHz P7P55D Motherboard Qualied V endors Lists (QVL) DDR3-2000MHz capability for CPU at 2.8 and 2.93GHz V endor Part No.
ASUS P7P55D 2-19 Chapter 2 2.4.4 Removing a DIMM T o remove a DIMM 2. Remove the DIMM from the socket. Support the DIMM lightly with your ngers when pressing the retaining clip. The DIMM might get damaged when it ips out with extra force. 2.4.3 Installing a DIMM 3.
2-20 Chapter 2: Hardware information Chapter 2 2.5 Expansion slots In the future, you may need to install expansion cards. The following subs ections describe the slots and the expansion cards that they support. 2.5.1 Installing an expansion card T o install an expansion card 1.
ASUS P7P55D 2-21 Chapter 2 2.5.3 Interrupt assignments Standard interrupt assignments * These IRQs are usually available for PCI devices. IRQ Priority Standard function 0 1 System T imer 1 2 Keyboard .
2-22 Chapter 2: Hardware information Chapter 2 2.5.4 PCI slots The PCI slots support cards such as a LAN card, SCSI card, USB card, and other cards that comply with PCI specications.
ASUS P7P55D 2-23 Chapter 2 • In single VGA card mode, use the PCIe 2.0 x16_1 slot (blue) for a PCI Express x16 graphics card to get better performance. • We recommend that you provide sufcient power when running CrossFireX™ mode. See page 2-38 for details.
2-24 Chapter 2: Hardware information Chapter 2 2.6 Onboard switch Onboard switch allows you to ne-tune performance when working on a bare or open- case system. This is ideal for overclockers and gamers who continually change settings to enhance system performance.
ASUS P7P55D 2-25 Chapter 2 2.7 Jumpers 1. Clear RTC RAM (3-pin CLRTC) This jumper allows you to clear the Real T ime Clock (RTC) RAM in CMOS. Y ou can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data.
2-26 Chapter 2: Hardware information Chapter 2 2. DRAM overvoltage setting (3-pin OV_DRAM) This jumper allows you to enable or disable the DRAM overvoltage settings in BIOS. • Before you change the jumper settings for extra-high overvoltage ability , use the BIOS items rst to adjust the desired DRAM performance.
ASUS P7P55D 2-27 Chapter 2 2.8 Connectors 2.8.1 Rear panel connectors Rear panel connectors 1. PS/2 mouse port (green) 7. Optical S/PDIF Out port 2. USB 2.0 ports 7 and 8 8. External SA T A port 3. USB 2.0 ports 5 and 6 9. IEEE 1394a port 4. USB 2.0 ports 3 and 4 10.
2-28 Chapter 2: Hardware information Chapter 2 2.8.2 Audio I/O connections Audio I/O ports Connect to Headphone and Mic ** Audio 2, 4, 6, or 8-channel conguration SPEED LED ACT/LINK LED LAN port Ac.
ASUS P7P55D 2-29 Chapter 2 Connect to Stereo Speakers Connect to 2.1 channel Speakers Connect to 4.1 channel Speakers.
2-30 Chapter 2: Hardware information Chapter 2 Connect to 5.1 channel Speakers Connect to 7.1 channel Speakers.
ASUS P7P55D 2-31 Chapter 2 2.8.3 Internal connectors 1. Digital audio connector (4-1 pin SPDIF_OUT) This connector is for an additional Sony/Philips Digital Interface (S/PDIF) port(s). Connect the S/PDIF Out module cable to this connector , then install the module to a slot opening at the back of the system chassis.
2-32 Chapter 2: Hardware information Chapter 2 Drive jumper setting Mode of device(s) Cable connector Single device Cable-Select or Master - Black T wo devices Cable-Select Master Black Slave Gray Master Master Black or gray Slave Slave 3. IDE connector (40-1 pin PRI_EIDE) The onboard IDE connector is for the Ultra DMA 133/100/66 signal cable.
ASUS P7P55D 2-33 Chapter 2 • T hese connectors are set to Standard IDE mode by default. In Standard IDE mode, you can connect Serial A T A boot/data hard disk drives to these connectors. If you intend to create a Serial A T A RAID set using these connectors, set the Congure SA T A as item in the BIOS to [RAID].
2-34 Chapter 2: Hardware information Chapter 2 5. JMicron ® JMB363 Serial A T A connector (7-pin SA T A_E1) This connector is for the Serial A T A signal cable for Serial A T A hard disk drives and optical disc drives.
ASUS P7P55D 2-35 Chapter 2 6. USB connectors (10-1 pin USB910, USB11 12, USB1314) These connectors are for USB 2.0 ports. Connect the USB module cable to any of these connectors, then install the module to a slot opening at the back of the system chassis.
2-36 Chapter 2: Hardware information Chapter 2 8. IEEE 1394a port connector (10-1 pin IE1394_2) This connector is for an IEEE 1394a port. Connect the IEEE 1394a module cable to this connector , then install the module to a slot opening at the back of the system chassis.
ASUS P7P55D 2-37 Chapter 2 10. CPU, chassis, and power fan connectors (4-pin CPU_F AN, 4-pin CHA_F AN1, 3-pin CHA_F AN2, 3-pin PWR_FAN) The fan connectors support cooling fans of 350 mA~1000 mA (12 W max.
2-38 Chapter 2: Hardware information Chapter 2 1 1. A TX power connectors (24-pin EA TXPWR, 8-pin EA TX12V) These connectors are for A TX power supply plugs. The power supply plugs are designed to t these connectors in only one orientation. Find the proper orientation and push down rmly until the connectors completely t.
ASUS P7P55D 2-39 Chapter 2 • System power LED (2-pin PLED) This 2-pin connector is for the system power LED. Connect the chassis power LED cable to this connector . The system power LED lights up when you turn on the system power , and blinks when the system is in sleep mode.
2-40 Chapter 2: Hardware information Chapter 2 2.8.4. ASUS Q-Connector (system panel) Use the ASUS Q-Connector to connect/disconnect the chassis front panel cables. T o install the ASUS Q-Connector 1. Connect the front panel cables to the ASUS Q-Connector .
ASUS P7P55D 2-41 Chapter 2 2.9 Onboard LEDs 1. POST State LEDs POST State LEDs check key components (CPU, DRAM, VGA card, and HDD) in sequence during motherboard booting process. If an error is found , the LED next to the error device will continue lighting until the problem is solved.
2-42 Chapter 2: Hardware information Chapter 2 2.10 Starting up for the rst time 1. After making all the connections, replace the system case cover. 2. Ensure that all switches are off. 3. Connect the power cord to the power connector at the back of the system chassis.
ASUS P7P55D 3-1 3.1 Knowing BIOS BIOS (Basic Input and Output System) stores system hardware settings such as storage device conguration, overclocking settings, advanced power management, and boot device conguration that are needed for system startup in the motherboard CMOS.
3-2 Chapter 3: BIOS setup Chapter 3 Installing ASUS Update T o install ASUS Update: 1. Place the support DVD in the optical drive. 2. From th e Main menu, cli ck the Utilit ies ta b, and then c lick In stall ASUS U pdate VX.X X. XX . 3. The ASUS Update utility is copied to your system.
ASUS P7P55D 3-3 Chapter 3 b. Select the ASUS FTP site nearest you to avoid network trafc, or click Auto Select . Click Next . c. From the FTP site, select the BIOS version that you wish to download, then click Next . Updating from a BIOS file a. Select Select Update BIOS from a le , then click Next .
3-4 Chapter 3: BIOS setup Chapter 3 P7P55D P7P55D.ROM Ensure to load the BIOS default settings to ensure system compatibility and stability . Select the Load Setup Defaults item under the Exit menu. See section 3.10 Exit Menu for details. b. Locate the BIOS le from the Open Locate the BIOS le from the Open window , then click Open .
ASUS P7P55D 3-5 Chapter 3 3.2.2 ASUS EZ Flash 2 utility The ASUS EZ Flash 2 feature allows you to update the BIOS without using an OS-based utility . Before you start using this utility , download the latest BIOS from the ASUS website at www. asus.com.
3-6 Chapter 3: BIOS setup Chapter 3 3.3 BIOS setup program Use the BIOS Setup program to update the BIOS or congure its parameters. The BIOS screens include navigation keys and brief online help to guide you in using the BIOS Setup program.
ASUS P7P55D 3-7 Chapter 3 Using the power button, reset button, or the <Ctrl>+<Alt>+<Del> keys to force reset from a running operating system can cause damage to your data or system. We recommend to always shut down the system properly from the operating system.
3-8 Chapter 3: BIOS setup Chapter 3 3.3.3 Navigation keys At the bottom right corner of a menu screen are the navigation keys for that particular menu. Use the navigation keys to select items in the menu and change the settings. The navigation keys may differ from one screen to another .
ASUS P7P55D 3-9 Chapter 3 3.4 Main menu When you enter the BIOS Setup program, the Main menu screen appears, giving you an overview of the basic system information. Y ou can also set the system time and date and BIOS language in this menu. Refer to 3.
3-10 Chapter 3: BIOS setup Chapter 3 T ype [Auto] Allows you to select the type of SA T A drive installed. [Not Installed] Select this option if no SA T A drive is installed. [Auto] Allows automatic selection of the appropriate SA T A device type. [CDROM] Select this option if you are specically conguring a CD-ROM drive.
ASUS P7P55D 3-1 1 Chapter 3 3.4.2 Storage Conguration The Storage Conguration menu allows you to congure your storage devices. Select an item then press <Enter> to display the submenu.
3-12 Chapter 3: BIOS setup Chapter 3 SA T A Port1 [Auto] Allows you to select the type of device connected to the system. Conguration options: [Auto] [Not Installed] SMART Monitoring [Enabled] Allows you to set the Self-Monitoring, Analysis and Reporting T echnology .
ASUS P7P55D 3-13 Chapter 3 3.5 Ai Tweaker menu The Ai T weaker menu items allow you to congure overclocking-related items. Be cautious when changing the settings of the Ai T weaker menu items. Incorrect eld values can cause the system to malfunction.
3-14 Chapter 3: BIOS setup Chapter 3 3.5.3 Ai Overclock T uner [Auto] Allows selection of CPU overclocking options to achieve desired CPU internal frequency . Select either one of the preset overclocking conguration options: Manual Allows you to individually set overclocking parameters.
ASUS P7P55D 3-15 Chapter 3 3.5.5 Intel(R) SpeedStep(TM) T ech [Enabled] When set to [Disabled], the CPU runs at its default speed. When set to [Enabled], the CPU speed is controlled by the operating system. Conguration options: [Disabled] [Enabled] 3.
3-16 Chapter 3: BIOS setup Chapter 3 1st Information: 7-7-7-20-4-59-8-6-20 The values vary depending on your settings of the following sub-items: DRAM CAS# Latency [Auto] Conguration options: [Auto.
ASUS P7P55D 3-17 Chapter 3 DRAM WRITE to READ Delay(DR) [Auto] Conguration options: [Auto] [1 DRAM Clock] – [8 DRAM Clock] DRAM WRITE to READ Delay(SR) [Auto] Conguration options: [Auto] [10 D.
3-18 Chapter 3: BIOS setup Chapter 3 Offset V oltage [Auto] This item appears only when you set the CPU V oltage Mode item to [Offset] and allows you to set the Offset voltage.
ASUS P7P55D 3-19 Chapter 3 Blue Y ellow Purple Red IMC V oltage 1.10000V– 1.16875V 1.17500V– 1.22500V 1.23125V– 1.30000V 1.30625V– 1.70000V DRAM V oltage 1.5000V– 1.5625V 1.5750V– 1.6250V 1.6375V– 1.6875V 1.7000V– 2.5000V CPU PLL V oltage 1.
3-20 Chapter 3: BIOS setup Chapter 3 3.6.1 CPU Conguration The items in this menu show the CPU-related information that the BIOS automatically detects. The items shown in this screen may be different due to the CPU you installed. Be cautious when changing the settings of the Advanced menu items.
ASUS P7P55D 3-21 Chapter 3 CPU Ratio Setting [Auto] Allows you to adjust the ratio between CPU Core Clock and BCLK Frequency . Use the <+> and <-> keys to adjust the value. The valid value ranges dif ferently according to your CPU model. C1E Support [Enabled] [Enabled] Enables the C1E support function.
3-22 Chapter 3: BIOS setup Chapter 3 Active Processor Cores [All] [All] Activate all CPU cores in the processor package. [1] Activate only 1 CPU core in the processor package. [2] Activate 2 CPU cores in the processor package. A20M [Disabled] [Enabled] Legacy OSes and APs may need this function enabled.
ASUS P7P55D 3-23 Chapter 3 HDA Controller [Enabled] [Enabled] Enables the High Denition Audio Controller . [Disabled] Disables the controller . Front Panel T ype [HD Audio] [AC97] Set the front panel audio connector (AAFP) mode to legacy AC’97 [HD Audio] Set the front panel audio connector (AAFP) mode to high-denition audio.
3-24 Chapter 3: BIOS setup Chapter 3 3.6.4 USB Conguration The items in this menu allows you to change the USB-related features. Select an item then press <Enter> to display the conguration options. The USB Devices Enabled item shows the auto-detected values.
ASUS P7P55D 3-25 Chapter 3 3.6.5 PCIPnP The PCIPnP menu items allow you to change the advanced settings for PCI/PnP devices. Plug And Play O/S [No] [Y es] When set to [Y es] and if you install a Plug and Play operating system, the operating system congures the Plug and Play devices not required for boot.
3-26 Chapter 3: BIOS setup Chapter 3 3.7.1 Suspend Mode [Auto] Allows you to select the Advanced Conguration and Power Interface (ACPI) state to be used for system suspend. [S1 (POS) only] Sets the APCI suspend mode to S1/POS (Power On Suspend). [S3 only] Sets the APCI suspend mode to S3/STR (Suspend T o RAM).
ASUS P7P55D 3-27 Chapter 3 3.7.6 APM Conguration APM Conguration Restore on AC Power Loss [Power Off] Power On By RTC Alarm [Disabled] Power On By External Modems [Disalbed] Power On By PCI Devi.
3-28 Chapter 3: BIOS setup Chapter 3 3.7.7 Hardware Monitor CPU/MB T emperature [xxxºC/xxxºF] [xxxºC/xxxºF] The onboard hardware monitor automatically detects and displays the CPU and motherboard temperatures. Select Ignored if you do not wish to display the detected temperatures.
ASUS P7P55D 3-29 Chapter 3 Chassis Q-Fan Control [Disabled] [Disabled] Disables the Chassis Q-Fan control feature. [Enabled] Enables the Chassis Q-Fan control feature. Chassis Fan Profile [Standard] This item appears only when you enable the Chassis Q-Fan Control feature and allows you to set the appropriate performance level of the chassis fan.
3-30 Chapter 3: BIOS setup Chapter 3 3.8.2 Boot Settings Conguration Quick Boot [Enabled] [Disabled] When set to [Disabled], BIOS performs all the POST items. [Enabled] When set to [Enabled], BIOS skips some power on self tests (POST) while booting to decrease the time needed to boot the system.
ASUS P7P55D 3-31 Chapter 3 3.8.3 Security The Security menu items allow you to change the system security settings. Select an item then press <Enter> to display the conguration options.
3-32 Chapter 3: BIOS setup Chapter 3 User Access Level [Full Access] This item allows you to select the access restriction to the Setup items. [No Access] Prevents user access to the Setup utility . [View Only] Allows access but does not allow change to any eld.
ASUS P7P55D 3-33 Chapter 3 3.9 Tools menu The T ools menu items allow you to congure options for special functions. Select an item then press <Enter> to display the submenu.
3-34 Chapter 3: BIOS setup Chapter 3 3.9.3 ASUS EZ Flash 2 Allows you to run ASUS EZ Flash 2. When you press <Enter>, a conrmation message appears. Use the left/right arrow key to select between [Y es] or [No], then press <Enter> to conrm your choice.
ASUS P7P55D 3-35 Chapter 3 3.9.4 Express Gate [Auto] Allows you to enable or disable the ASUS Express Gate feature. The ASUS Express Gate feature is a unique instant-on environment that provides quick access to the Internet browser and Skype.
3-36 Chapter 3: BIOS setup Chapter 3 3.10 Exit menu The Exit menu items allow you to load the optimal or failsafe default values for the BIOS items, and save or discard your changes to the BIOS items. Pressing <Esc> does not immediately exit this menu.
ASUS P7P55D 4-1 If Autorun is NOT enabled in your computer , browse the contents of the support DVD to locate the le ASSETUP .EXE from the BIN folder . Double-click the ASSETUP .EXE to run the DVD. 4.1 Installing an operating system This motherboard supports Windows ® XP/ 64-bit XP/ Vista / 64-bit V ista / 7 / 64-bit 7 operating systems (OS).
4-2 Chapter 4: Software support Chapter 4 4.2.2 Obtaining the software manuals The software manuals are included in the support DVD. Follow the instructions below to get the necessary software manuals. The software manual les are in Portable Document Format (PDF).
ASUS P7P55D 4-3 Chapter 4 4.3 Software information Most of the applications in the support DVD have wizards that will conveniently guide you through the installation. View the online help or readme le that came with the software application for more information.
4-4 Chapter 4: Software support Chapter 4 4.3.2 ASUS AI Suite ASUS AI Suite allows you to launch several ASUS utilities easily . Launching AI Suite 1. Install AI Suite from the motherboard support DVD. 2. Launch AI Suite by clicking Start > All Programs > ASUS > AI Suite > AI Suite v1.
ASUS P7P55D 4-5 Chapter 4 4.3.3 ASUS Fan Xpert Asus Fan Xpert allows you to adjust both the CPU and chassis fan speeds according to different ambient temperatures and your PC’ s system loading. The various fan proles offer exible controls of fan speeds to achieve a quiet and cool system environment.
4-6 Chapter 4: Software support Chapter 4 4.3.4 ASUS EPU-6 Engine ASUS EPU-6 Engine is an energy-efcient tool that satises different computing needs.
ASUS P7P55D 4-7 Chapter 4 4.3.5 ASUS Express Gate ASUS Express Gate is an instant-on environment that gives you quick access to the Internet, Skype, and viewing your pictures. Within a few seconds of powering on your computer , you will be at the Express Gate menu where you can start the web browser , Skype, or other Express Gate applications.
4-8 Chapter 4: Software support Chapter 4 Refer to the software manual in the support DVD or visit the ASUS website at www .asus.com for detailed software conguration. B. VIA HD Audio Deck for Windows XP Control settings window Conguration options Display panel and volume control Minimize button 4.
ASUS P7P55D 4-9 Chapter 4 4.4 ASUS Unique Overclocking Utility— TurboV EVO ASUS T urboV EVO introduces T urboV and T urbo Key —two powerful tools that allow you to overclock your system effectively and safely . Install ASUS T urboV EVO from the support DVD that came with the motherboard package.
4-10 Chapter 4: Software support Chapter 4 4.4.2 Using ASUS T urboV Auto T uning Mode The Auto T uning Mode allows smart auto-overclocking. Follow the instructions below to let T urboV EVO detect and overclock your system. • After pressing Start, the system starts performance tuning and may reboot 2 to 3 times.
ASUS P7P55D 4-1 1 Chapter 4 4.4.3 Using ASUS T urbo Key ASUS T urbo Key allows the user to set a group of hot-keys into physical overclocking buttons. After the easy setup, T urbo Key can boost perfor.
4-12 Chapter 4: Software support Chapter 4 4.5 RAID congurations The motherboard comes with the Intel ® P55 chipset that allows you to congure Serial A T A hard disk drives as RAID sets. The motherboard supports the following RAID congurations: RAID 0, RAID 1, RAID 10 and RAID 5.
ASUS P7P55D 4-13 Chapter 4 4.5.4 Intel ® Matrix Storage Manager option ROM utility T o enter the Intel ® Matrix Storage Manager option ROM utility 1. Turn on the system. 2. During POST , press <Ctrl> + <I> to display the utility main menu.
4-14 Chapter 4: Software support Chapter 4 The navigation keys at the bottom of the screen allow you to move through the menus and select the menu options. The RAID BIOS setup screens shown in this section are for reference only and may not exactly match the items on your screen.
ASUS P7P55D 4-15 Chapter 4 5. Use the up/down arrow key to select a drive, and then press <Space> to sel ect. A small triangle marks the selected drive. Press <Enter> after completing your selection. 6. Use the up/down arrow key to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and then press <Enter>.
4-16 Chapter 4: Software support Chapter 4 Deleting a RAID set T ake caution when deleting a RAID set. Y ou will lose all data on the hard disk drives when you delete a RAID set. T o delete a RAID set 1. From the utility main menu, select 2. Delete RAID V olume and press <Enter>.
ASUS P7P55D 4-17 Chapter 4 4.6 Creating a RAID driver disk A oppy disk with the RAID driver is required when installing Windows ® XP operating system on a hard disk drive that is included in a RAID set. For Windows ® Vista or later operating systems, use either a oppy disk or a USB ash drive with the RAID driver .
4-18 Chapter 4: Software support Chapter 4 4.6.3 Installing the RAID driver during Windows ® OS installation T o install the RAID driver for Windows ® XP 1. During the OS installation, the system prompts you to press the F6 key to install third- party SCSI or RAID driver .
ASUS P7P55D 4-19 Chapter 4 4. Click Details tab. The V endor ID (VID) and Product ID (PID) are displayed. 5. Browse the contents of the RAID driver disk to locate the le txtsetup.oem . 6. Double-click the le. A window appears, allowing you to select the program for opening the oem le.
4-20 Chapter 4: Software support Chapter 4 8. Find the [HardwareIds.scsi.iaAHCI_PCH] and [HardwareIds.scsi.iastor_8R9R10RDOPCH] sections in the txtsetup.oem le. 9. Type the following line to the bottom of the two sections: id = “USBVID_xxxx&PID_xxxx”, “usbstor” 10.
ASUS P7P55D 5-1 Chapter 5 Chapter 5: Multiple GPU technology support 5.1 ATI ® CrossFireX™ technology The motherboard supports the A TI ® CrossFireX™ technology that allows you to install multi- graphics processing units (GPU) graphics cards. Follow the installation procedures in this section.
5-2 Chapter 5: Multiple GPU technology support Chapter 5 4. Align and rmly insert the CrossFireX bridge connector to the goldngers on each graphics card. Ensure that the connector is rmly in place. 5.1.3 Installing two CrossFireX™ graphics cards The following pictures are for reference only .
ASUS P7P55D 5-3 Chapter 5 5.1.4 Installing the device drivers Refer to the documentation that came with your graphics card package to install the device drivers. Ensure that your PCI Express graphics card driver supports the A TI ® CrossFireX™ technology .
5-4 Chapter 5: Multiple GPU technology support Chapter 5 Enabling Dual CrossFireX settings 1. In the Catalyst Control Center window, click Graphics Settings > CrossFireX > Congure . 2. From the Graphics Adapter list, select the graphics card to act as the display GPU.
Een belangrijk punt na aankoop van elk apparaat Asus P7P55D (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Asus P7P55D heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Asus P7P55D vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Asus P7P55D leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Asus P7P55D krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Asus P7P55D bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Asus P7P55D kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Asus P7P55D . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.