(Lens : option) SDII day/night Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.
-2- WARNING: To prevent fire or electric shock hazard, do not expose this appliance to rain or moisture. The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus.
-3- IMPORT ANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings.
-4- CONTENTS IMPORTANT SAFETY INSTRUCTIONS ....................... 3 PREFACE ..................................................................... 5 Features .................................................................... 5 Computer Requirements .
-5- Features • 10/100BASE-T terminal enables your PC to view camera images via the network. • SD II (super dynamic) system allows a wide range of 46 dB while preventing images from being spoiled by strong background light. • High resolution supported by a 1/3” CCD having 380 000 pixels •A 0.
-6- 1. The installation should be made by qualified service personnel or system installers. 2. Do not attempt to disassemble the camera. To prevent electric shock, do not remove screws or covers. There are no user-serviceable parts inside. Ask qualified service personnel for servicing.
t i yo u q w e r WV – NP472 ALARM IN ALARM OUT AUX OUT DAY/NIGHT IN GND AB VIDEO OUT RCV LINK 10BASE-T/ 100BASE-TX POWER DC 12V IN !3 !4 !2 !1 !0 -7- MAJOR OPERA TING CONTROLS AND THEIR FUNCTIONS Slide the panel to the left until it locks.
-8- • Mounting the Lens Notes: • Using the lens having improper protrusion will damage the camera. The protrusion of the lens into the camera body should be within the length indi- cated in the figure. • Secure both the lens and camera with the support- er (not supplied) if a lens heavier than 450 g (0.
-9- • Flange-back Adjustment The adjustment is required only when a lens without focus-adjusting mechanism is mounted, or when a lens with adjusting mechanism is mounted and focus that is more accurate is needed. 1. Loosen the flange-back fixing screw on the flange- back adjusting ring.
-10- Power-in Connections Notes: • Use only a class-2 power supply suitable to the voltage and current required by the camera. See specifications. • Use a UL listed cable (VW-1, style 1007) to pre- vent fire or electric shock. You can use the formula below to select the power supply, and power cable.
• Connection to Intranet (Type 2) • Connection to Internet (Type 3) • Connection to Internet (Type 4) -11- ALARM IN ALARM OUT AUX OUT DAY/NIGHT IN GND AB VIDEO OUT RCV LINK 10BASE-T/ 100BASE-TX .
-12- OPERA TING THE CAMERA You can operate the camera in two ways: from the PC by way of network, or locally from the camera or system device. Access from the PC Your PC can access the camera to view images and to set up menus. Prior to operating from the PC, confirm that connections are made properly as shown in the previous page, CONNECTIONS.
• Function Comparison / PC Network vs. Camera site -13- 4. Set the following parameters. Note: Ask your system administrator about param- eters if you are unsure. IP Address: Enter numbers 0 through 255 into four sections split by dots. Netmask: Enter numbers 0 through 255 into four sections split by dots.
-14- PRIOR TO SETUP This section describes setup procedures common to accesses from the PC and from the camera. The PC can control more functions than camera itself, e.g. transmitting images to FTP server, sending alarm notice mail, auxiliary device control, clock setup, and LED control.
-15- 7. Move the cursor to CAMERA O , and click the ENTER button. CAM SETUP opens. Notes: • Refer to the next page for setup operations. • Return the menu to ** SET UP *** (step 3 above), then go to step 8. 8. Click the Menu OFF button after finishing the setup operations.
-16- The following pages describe setting operations from the camera. For accessing from the PC, interpret these instructions as follows. SETTING PROCEDURES SETUP SELECTION 1. Move the cursor to CAMERA or NETWORK, and press I to open the desired setup menu.
-17- To edit the CAMERA ID 1. Move the cursor to CAMERA ID. The factory default setting is OFF. 2. Press I . The CAMERA ID menu appears. The cursor on the letter “0” is highlighted. 3. Move the cursor to the character you want to edit by pressing L / M / J / K .
-18- 2-2. ALC Mode with SUPER-D2 OFF and ELC Mode Note: If ELC is selected, set MASK SET according to this procedure. 1. Move the cursor to SUPER-D2 and select OFF. (When you select ELC, SUPER-D2 is not available.) MASK SET appears on the menu. 2. Move the cursor to MASK SET and press I .
-19- 5. Electronic Sensitivity Enhancement (SENS UP) There are two modes for SENS UP. AUTO: If you select X10 AUTO, for example, the sensitivity is automatically raised to X10 max. When AUTO is selected, AGC is automatically set to ON. FIX: If you select X32 FIX, for example, the sensitiv- ity is raised to just X32.
-20- Manual Fine Adjustment for AWC (ATW) You can set the white balance items manually. 1. To set MASK SET, proceed as described in steps 2 to 4 of “ALC mode with SUPER-D2 OFF and ELC mode”. 2. Move the cursor to R. 3. Press L or M to obtain the optimum amount of red gain.
-21- 10. Special Menu This menu lets you adjust and set up the video signal of the camera to meet your requirements. Move the cursor to RET in the bottom line of the CAM SET UP menu and press L and M simultaneously (holding down L and press M ) for 2 seconds or more.
-22- To reset to the factory settings (CAMERA RESET) 1. Move the cursor to CAMERA RESET. PUSH SW is highlighted. 2. While holding down L and M , hold down I for 2 seconds or more. The camera is reset to the factory settings. NETWORK SETUP Set up network parameters when connecting the 10/100BASE jack with a network.
-23- SETUP FROM THE PC PREP ARA TIONS FOR THE PC ■ Connections Prior to connections, specify the connection type and prepare relevant devices and cables. Notes: • We recommend that you use connection type 1 or type 2 when setting up the network address of the camera.
-24- ■ Network Setup of the PC To set up the network of the PC, first change the TCP/IP settings of the PC to match them to the default settings of the camera. The following are the default network settings of the camera. IP address : 192.168.0.10 Subnet mask : 255.
-25- 6. Click “Internet Protocol (TCP/IP)”, and then click the [Properties] button. 7. Click the “Use the following IP address” radio but- ton and enter the IP address and the subnet mask as follows. IP address : 192.168.0.9 Subnet mask : 255.
-26- 3. Click the Setup Menu button. The User Setup win- dow appears. • Enter “admin” in the user name column. • Click the OK button. ■ Network Setup Parameters vs. Connection T ype Connection type Item Description of the parameter Connection type 1 IP address Enter “192.
-27- Connection type 2 IP address Set the IP address designated by your network administrator. However, the setting is not required if DHCP is used in an intranet. Subnet mask Set the subnet mask designated by your network administra- tor. However, the setting is not required if DHCP is used in an intranet.
-28- Secondary server Set the IP address of DNS when using the DNS server. Refer to your internet Internet service provider for the IP address of the DNS.
-29- Host name Refer to your Internet service provider and set the designated host name if required. DNS Set to ON when using the DNS server. Primary server No setting required Secondary server Set the IP address of DNS when using the DNS server. Refer to your internet Internet service provider for the IP address of the DNS.
-30- CAMERA SETUP FROM THE PC The camera setup menus overlaid on the camera pic- ture appear by clicking the Camera Setup button in the main page. You will be prompted by authentication dia- log box.
-31- ■ Camera Setup Menus Menu windows are shown in this page. Refer to page 16 for menu operations..
-32- Setup windows listed below are accessible only from the PC. Operations in these windows are described in the following pages. Click any of the setup selection buttons on top of the screen to open the desired window. The following are opened from the Network Setup win- dow.
-33- 3. E-Mail Notice Setup • Select ON or OFF for E-mail Notice. ON: Sends an e-mail when an alarm operates. OFF: Does not send. • Enter the e-mail server address. A hostname.domainname can be entered when using the DNS function. • Enter the sender name.
-34- • Enter a file name and click a radio button. Fix: Uses repeatedly a single file name when overwriting new data. Date & Time: Creates and attaches a serial number and a date-and-time to the entered file name. • Set a transmission interval.
-35- ■ Host Setup Note: Never turn over the order: start with the host reg- istration, and then proceed to the authentication ON/OFF. 1. Open the Host Setup window. 2. Host Registration • Enter the IP address of the PC. A hostname.domainname can be entered when using the DNS function.
-36- You can reset the following data back to the factory default settings. Camera Setup Setup Menu (PC oriented) HTML files ■ Initializing the Camera Menu • Move the cursor to CAMERA RESET. • Hold down simultaneously L and M buttons for 2 seconds on the camera, or click the All Reset button on your computer display.
-37- VIEWING PICTURES ■ Image Quality Selection 1. Click the Setup Menu button in the main page. The Network Setup window opens. 2. Click the Image button in the menu bar lined on top of the screen. The Image Setup window appears. 3. Select the parameters.
-38- ■ Monochrome Mode You can switch the camera between the color mode and black-and-white mode. This may help picture become clear under conditions of insufficient lighting. 1. In the main page, click the Camera Menu button. 2. The Day & Night button appears in the lower-left of the screen.
-39- When an alarm sounds, the camera performs output functions depending on the setup. Inputs: • The alarm sensor connected to the ALARM IN ter- minal on the camera • The built-in VMD (Video Moti.
-40- ■ Canceling Alarm Display “Alarm” display in the upper right corner will disappear when you operate the following. • Click the Return button after once opening Alarm List. Or • Click the Return button after opening any of setup menus. ■ VMD Setup You can setup VMD (video Motion Detector).
-41- Transparency: Indicates a non-masked area that has been incorporated into the detection area. Blink: Indicates a non-masked area when the cur- sor is on it. Highlight: Indicates a masked area that has been exempted from detection. Stripe: Indicates an area already set to masked when the cursor is on it.
-42- 3. The selected picture is displayed, and the alarm image control panel appears on the bottom of the screen. The title of the control panel is followed by a fraction indicating the number of the displayed picture and total number for the event. 4.
-43- AUXILIAR Y OUTPUT CONTROL ■ Auxiliary Output Control You can turn on or off the connected device, for exam- ple a lamp that is connected to the AUX OUT terminal of the camera. 1. Open the auxiliary output control window clicking the AUX Output Control button in the main page.
Symptom No picture is displayed. -44- TROUBLESHOOTING HTML documents are not displayed. • Is the AC adapter firmly plugged in to the outlet? • Are the POWER IN terminals on the camera connected wi.
-45- SPECIFICA TIONS General Ambient Operating Temperature: –10 °C - +50 °C (14 °F - 122 °F) Ambient Operating Humidity: Less than 90 % Power Source and Power Consumption: 12 V DC, 700 mA Dimensions (without lens): 70 mm (W) x 65 mm (H) x 118 mm (D) 2-3/4” (W) x 2-5/8” (H) x 4-5/8” (D) Weight (without lens): 0.
-46- ST ANDARD ACCESSORIES Body Cap .............................................................................. 1 pc. ALC Lens Connector (YFE4191J100) ................................... 1 pc. CD-ROM (PDF Manual Contained) .........................
N1002-1112 3TR001281BAB Printed in Japan PANASONIC CANADA INC. 5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905)624-5010 PANASONIC SALES COMPANY DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO INC. San Gabriel Industrial Park 65th Infantry Ave.
Een belangrijk punt na aankoop van elk apparaat Panasonic WV-NP472 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Panasonic WV-NP472 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Panasonic WV-NP472 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Panasonic WV-NP472 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Panasonic WV-NP472 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Panasonic WV-NP472 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Panasonic WV-NP472 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Panasonic WV-NP472 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.