Software Configuration Guide

Patton Electronics Company, Inc.
7622 Rickenbacker Drive Gaithersburg, MD 20879 USA
Copyright Copyright © 2012, Patton Electronics Company. All rights reserved.
Electronics assumes no liability for errors that may appear in this document.
The software described in this document is furnished under a license and may
be used or copied only in accordance with the terms of such license.
Supported Models

1 Getting Started with the Web Portal 22
2 Configuring VoIP Interfaces 36
3 Configuring an ISDN-SIP Gateway 42
4 Configuring SS7 Signaling 80
5 Configuring SIGTRAN Applications 112
6 Configuring CAS R2 191
7 Configuring H.248 203
8 Configuring SNMP 220
9 Contacting Patton 226


1 SmartNode Web Portal Navigation 24 2 SmartNode Web Portal Menus 24 3 SmartNode User Access Levels 25 4 Global > Users 25 5 User List 26 6 User List > Create New User 26 7 User List > Delete User 27 8 Navigation Menu: Logout 27 9 Global > Backups 28 10 Backups > Create new database backup 28 11 Database Backup Message 28 12 Database Backup List 28 13 Download Database Backup 29 14 Upload Database Backup File 29 15 Restore Database Backup File 29 16 Applications > Instances 30 17 Application Instance List 30 18 Application Instance List > Edit 31 19 Application Status 31 20 Apply States 31 21 SmartNode Interfaces 32 22 Application Status List 32 23 Global > Systems 33 24 System List 33 25 Name and Activate Configuration 33 26 Successful Activation 34 27 Global > Status 34 28 Status: General View 35 29 Status: Detailed View 35 30 Menu > IP Interfaces 37 31 IP Interface List 37 32 Editing an IP Interface 38 33 Adapters (General View) 39 34 Adapters (Detailed View) > Hardware 40 35 Adapters (Detailed View) > Sensors 40 36 Adapters (Detailed View) > Licensed Features 41 37 IP Interfaces (Detailed View) 41 38 Global > Configurations 44 39 Configuration List 45 40 Name and Copy a Configuration File 45 41 Successful Configuration Copy 45 42 TDM Interfaces > Line Interfaces 46 43 Line Interface List 46 44 Create New Line Interface 47 45 Confirmation Message for New Line Interface 47 46 TDM Interfaces > Line Interfaces 48 47 Line Interface List 48

Smart Media Software Configuration Guide
48 Editing a Line Interface to Create a New Service 48 49 Create New Line Service 49 50 Line Services List 49 51 Menu: IP Interfaces 50 52 Editing Port Ranges 51 53 Creating a New Port Range 51 54 Confirmation Message for Port Range 51 55 Signaling > ISDN 52 56 ISDN Stack List 52 57 Create New ISDN Stack 53 58 Confirmation Message for New ISDN Stack 53 59 Menu: Clocking 54 60 External System Clock Reference List 54 61 Creating New External System Clock 54 62 Confirmation Message for System Clock 54 63 Menu: SIP 55 64 SIP Configuration List 56 65 Creating a New SIP Stack 56 66 Confirmation Message for SIP 56 67 Menu: SIP 57 68 Edit SIP Configuration List 57 69 Transport Servers List 57 70 Creating a New SIP Transport Server 58 71 Confirmation Message for SIP Transport Server 58 72 Menu: SIP 59 73 Edit SIP Configuration List 59 74 Service Access Points (SAP) List 59 75 Creating a New SAP 59 76 Confirmation Message for SIP SAP 59 77 Associating Transport Servers 60 78 Menu: Profiles 60 79 Edit Profile List 61 80 DTMF Relay Scheme List 61 81 Menu: NAP 65 82 Edit NAP List 65 83 Creating a New ISDN NAP 65 84 Confirmation Message for New NAP 65 85 Associating ISDN Stacks with NAPs 66 86 Menu: NAP 66 87 Edit NAP List 66 88 Creating a New SIP NAP 67 89 Confirmation Message for New NAP 67 90 Associating SIP SAPs with NAPs 67 91 Configurations > Routes 69 92 Static Routes List 69 93 Creating a New Route 70 94 Confirmation Message for New Route 70 95 General View: Line Interfaces and Services 72 96 Detailed View: Line Interface 73 97 Detailed View: Line Service 73 98 General View: ISDN Stack List 74







1 Configuration Parameters for IP Interfaces 38 2 Configuration Parameters for New Line Interfaces 47 3 Configuration Parameters for New Line Services 50 4 Loopback Types 50 5 Configuration Parameters for New IP Port Ranges 51 6 Configuration Parameters for New ISDN Stacks 53 7 Configuration Parameters for the Clocking Source 55 8 Configuration Parameters for New SIP Stacks 57 9 Configuration Parameters for SIP Transport Servers 58 10 Configuration Parameters for SIP SAPs 60 11 Codec Payload Type Values 63 12 Configuration Parameters for NAPs 66 13 Configuration Parameters for SIP NAPs 68 14 Configuration Parameters for Static Routes 71 15 Configuration Parameters for New MTP2 Configurations 83 16 Configuration Parameters for New MTP2 Links 85 17 Configuration Parameters for New MTP3 Configurations 87 18 Configuration Parameters for New MTP3 Networks 88 19 Configuration Parameters for New Point Codes 89 20 Configuration Parameters for New MTP3 Linksets 91 21 Configuration Parameters for New MTP3 Links 93 22 Configuration Parameters for New MTP3 Routes 95 23 Configuration Parameters for New ISUP Stack 96 24 Configuration Parameters for New ISUP Network 98 25 Configuration Parameters for New ISUP User Part 99 26 Configuration Parameters for New ISUP Interface 101 27 Circuit Group Status Settings 111 28 Configuration Parameters for New Hardware Adapters 119 29 Configuration Parameters for New Line Interfaces 120 30 Configuration Parameters for New Line Services 123 31 Loopback Types 123 32 Configuration Parameters for New SCTP Configurations 124 33 Configuration Parameters for New M2PA Configurations 125 34 Configuration Parameters for New M2PA SAP 127 35 Configuration Parameters for New M2PA Links 128 36 Configuration Parameters for New Point Codes 130 37 Configuration Parameters for New MTP3 Configurations 132 38 Configuration Parameters for New MTP3 Networks 133 39 Configuration Parameters for New MTP3 Linksets 134 40 Configuration Parameters for New MTP3 (M2PA) Links 136 41 Configuration Parameters for New MTP3 Routes 138 42 Configuration Parameters for New ISUP Stack 139 43 Configuration Parameters for New ISUP Network 140

Smart Media Software Configuration Guide
44 Configuration Parameters for New ISUP User Part 142 45 Configuration Parameters for New ISUP Interface 143 46 Configuration Parameters for New ISUP CIC Group 145 47 Configuration Parameters for NAPs (SIGTRAN) 147 48 Configuration Parameters for New MTP2 Configurations 149 49 Configuration Parameters for New MTP2 Links 151 50 Configuration Parameters for New M2UA Configurations 152 51 Configuration Parameters for New M2UA SAP 153 52 Configuration Parameters for New M2UA Cluster 154 53 Configuration Parameters for New M2UA Links 155 54 Configuration Parameters for New M2UA Peers 157 55 Configuration Parameters for New MTP3 (M2UA) Links 159 56 Configuration Parameters for New IUA Configurations 161 57 Configuration Parameters for New IUA SAP 162 58 Configuration Parameters for New IUA Cluster 163 59 Configuration Parameters for New IUA Links 164 60 Configuration Parameters for New IUA Peers 165 61 Configuration Parameters for New M3UA Configurations 167 62 Configuration Parameters for New M3UA SAPs 169 63 Configuration Parameters for New M3UA Networks 170 64 Configuration Parameters for New M3UA User Part 171 65 Configuration Parameters for New M3UA PSPs 172 66 Configuration Parameters for New M3UA Peer Servers 174 67 Configuration Parameters for New M3UA Routes 176 68 Configuration Parameters for New MTP3 (M3UA) Links 179 69 Configuration Parameters for New M3UA Configurations 180 70 Configuration Parameters for New M3UA PSPs 182 71 Configuration Parameters for New M3UA Routes 184 72 Configuration Parameters for New M3UA Configurations 186 73 Configuration Parameters for New M3UA PSPs 188 74 Configuration Parameters for New M3UA ISUP Network 190 75 Configuration Parameters for New Hardware Adapters 194 76 Configuration Parameters for New Line Interfaces 195 77 Configuration Parameters for New Line Services 198 78 Loopback Types 198 79 Configuration Parameters for CAS R2 Stacks 201 80 Configuration Parameters for NAPs 202 81 Configuration Parameters for New Hardware Adapters 206 82 Configuration Parameters for New Line Interfaces 207 83 Configuration Parameters for New Line Services 209 84 Loopback Types 209 85 Configuration Parameters for New IP Port Ranges 211 86 Configuration Parameters for VoIP NAPs 213 87 Configuration Parameters for TDM NAPs 214 88 Configuration Parameters for H.248 Configuration 217 89 Configuration Parameters for Media Gateway Controller 218

This Smart Media Software Configuration Guide describes how to configure components through the Web Por tal of Patton’s Smart Media system.
For detailed hardware or set-up information, refer to the product’s User Manual.
This guide is intended for the following users:
This guide contains the following chapters and appendices:

![Page 23 of the Patton electronic 07MSMARTMEDIA-SCG user manual — – http://[DEVICE HOST NAME]:12358](/cdn/reader/5e/5eb47e281d7443d84615c0aa9f3c4d5e527d3848e4e8a8044f61458356a4d06f/images/page-23.webp?w=400)
Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
This chapter explains how to access and manage the SmartNode Web Portal. Refer to the following sections for more details on:
This section describes how to login and navigate the SmartNode Web Portal.
Connecting to the web server and logging on to the Web Portal The first step involved in initially configuring any Smart Media system involves logging on to the Web Portal. This can be divided into two distinct tasks: Connecting to the web server, and logging on to the Web Portal.
Connecting to the web server Using a web browser, connect to the Web Portal by typing the following in your address bar:
– http://[DEVICE IP ADDRESS]:12358
Logging on to the Web Portal In order to log on to the Web Portal configuration tool, enter the root user ID and password. The default values for these parameters are:
Navigating the Web Portal Effective use of the Web Portal requires a basic understanding of the physical elements of the tool, how to access its various components and knowing your current location in the Web Portal display. The following topics are covered: Navigation and Information Panels and Knowing Your Location.
Navigation and Information Panels The Web Portal has been designed with a consistent streamlined approach for the presentation of Smart Media configuration data. Information related to the hierarchy of data is displayed in the left-hand navigation panel, while information related to a selected category is displayed in the information panel found on the right side of the window.
Selecting a category in the navigation panel causes related configuration and status information to be dynami cally displayed. The navigation panel displays information in a tree-like structure enabling you to understand how configuration parameters are contained by others.
or, alternately, · Overview 23

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
Figure 1. SmartNode Web Portal Navigation
Knowing Your Location As you navigate the Web Portal, it is important that you understand how to determine your current location. The Web Portal has been designed to make this easy for you. When you browse through the navigation panel, your current selection is always indicated by a graphical highlight. In addition, the system configuration that you are using and the specific Smart Media unit that is being configured is always displayed, as shown in the figure below.
Figure 2. SmartNode Web Portal Menus
Accessing and Navigating the Web Interface 24

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
This section describes how to mange user access levels in the SmartNode Web Portal. (Refer to “Connecting to the web server and logging on to the Web Portal” on page 23 for information about how to login to the Web Portal).
Understanding User Access Levels The Web Portal is designed to provide varying degrees of write and read privileges to users. By default, the root user is given full read and write access. This is required so that the root user can function as the system admin istrator without any restrictions imposed. Subsequent users can be created with the ability to read and write, or just to read. An integer value from 0 - 9 is assigned to each user.
Figure 3. SmartNode User Access Levels
Viewing the User List It is possible to create an unlimited list of users, each with an assignment from 0-9. Any user can view the entire list of users, however only a root user with an access level of 0 can modify the access rights of other users.
To view the user list:
Figure 4. Global > Users
Managing Users 25

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
Figure 5. User List
Creating a New User 1. Select Users from the navigation panel.
Figure 6. User List > Create New User
Managing Users 26

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
Deleting a User 1. Select Users from the navigation panel.
Figure 7. User List > Delete User
Logging Off When you are finished working in the Web Portal, it is recommended that you log out from your session. If you do not log out, the session between the Web Browser on your PC and the Web Portal remains active.
To log out from the Web Portal, select Logout from the navigation panel.
Managing Users 27

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
After carrying out system modifications, it is recommended that you back up the SQL database. This section describes how to back up the database for the first time, retrieve a saved backup file, upload a new backup file, and restore the database from a backup file.
Carrying out a First Database Backup To create a backup file of the database:
Figure 9. Global > Backups
Figure 10. Backups > Create new database backup
Figure 11. Database Backup Message
Figure 12. Database Backup List
Managing the Database Backup 28

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
Downloading a Database Backup Once you have created a backup of your database, it is recommended that you download it to store it to an external storage device.
Figure 13. Download Database Backup
Uploading a Database Backup An external backup of your database can be uploaded to your SmartNode.
Figure 14. Upload Database Backup File
Restoring a Database Backup The configuration settings of your system can be restored from a local or remote copy of your database.
Figure 15. Restore Database Backup File
Managing the Database Backup 29

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
This section explains how to manage applications and instances on the SmartNode Web Portal, how to activate a configuration, and how to configure IP interfaces. Refer to the following sections for information on:
Managing Applications This section explains how to start up and verify applications and instances on the Smart Media application server.
Viewing the List of Installed Applications The Smart Media application server is designed to run a large variety of applications. Before you can run an application, you must first be able to view it from a list of applications. To view the selection of applications:
Figure 16. Applications > Instances
Figure 17. Application Instance List
Applications are displayed in one of three states:
– Run (application is operating)
– Management (application is installed but not in operation)
– Fault (application has an operation fault)
Starting an Application In order to be able to load and start an application, it will need to have been installed on the Smart Media application server. In addition, at least one Smart Media unit must have been configured on the Smart Media application server so that you are able to connect to it.
Working with Configurations 30

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
When you first log on to the Web Portal, your system application will have been installed on the Smart Media application server, and it will be in a management state. This means that the application is not yet operating and controlling your system. In order to start an application, its state must be changed from Management to Run. To start an application:
Figure 18. Application Instance List > Edit
Figure 19. Application Status
Figure 20. Apply States
Working with Configurations 31

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
Verifying that an Application is Operating When an application’s target state is set to run, there are a number of crucial verifications that you should con duct in order to know that an application is running properly. These verifications are as follows:
Figure 21. SmartNode Interfaces
Verifying the Application Path One important indication of the normal operation of an application is when the application path is displayed in the hardware status window. To verify that the application path is displayed:
Figure 22. Application Status List
Working with Configurations 32

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
Activating the Configuration Changes made to the configuration of the Smart Media units are stored on the OAM&P Configuration and Logging database. In order for changes to be used by the system, they must first be activated. This is done at the system level and accessed from the Navigation panel.
Figure 23. Global > Systems

Figure 24. System List
Figure 25. Name and Activate Configuration
Working with Configurations 33

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
Figure 26. Successful Activation
Verifying status General and detailed status information about the applications that are run by one or more host machine(s) is accessible from the Applications tab of the Global-->Status menu.
Figure 27. Global > Status
You may view the status in General View or Detailed View.
Working with Configurations 34

Smart Media Software Configuration Guide 1 • Getting Started with the Web Portal
General View: The general view, shown below, lists the applications, and their current general status (ready, fault, not running. This window also provides a count of all applications with ready or fault status.
Detailed View: A more detailed description of each application can be viewed by following the appropriate link in the general window (shown above). The detailed status screen, shown below, lists the states of the appli cation, its name, the host machine and the location of the application on the host.
From this detailed view, the Oam target state may be changed.
To modify the Oam target state of an application: Select a state from the Oam target state combo box. Click Apply States to change the states.
Working with Configurations 35


Smart Media Software Configuration Guide 2 • Configuring VoIP Interfaces
The IP interface of the VoIP0 and VoIP1 ports can be configured by setting the following:
To configure a VoIP0 or VoIP1 port:
Figure 30. Menu > IP Interfaces
Figure 31. IP Interface List
– Indicate whether or not to use DHCP on this port
– Enter an IP address
– Enter a Netmask
– Enter a gateway address
– Click Save · Overview 37

Smart Media Software Configuration Guide 2 • Configuring VoIP Interfaces
Figure 32. Editing an IP Interface
The system will display the following notice, describing steps to apply your new configuration:
Table 1. Configuration Parameters for IP Interfaces
Use DHCP Indicates that the DHCP autoconfiguration protocol is to be used on an IP port.
IP Address Sets an address for accessing a new media gateway controller (MGC).
Netmask Sets a subnetwork mask number on an IP port.
Gateway Associates the address of a TCP/IP network gateway with an IP port.
Configuring Interfaces 38

Smart Media Software Configuration Guide 2 • Configuring VoIP Interfaces
General and detailed status information about the Smart Media units, also referred to as adapters, is accessible from the Adapters tab of the Global Status view.
Adapters (General View) The general view of the Adapters status screen provides information about the Smart Media units in a system. From this view you can know the status of Smart Media units by seeing if they are up, down, or disabled. In addition, similar information can be known about the IP interfaces of the Smart Media units. Selecting a Smart Media unit link will cause its detailed view to be displayed. The same is true for the IP interface links.
Figure 33. Adapters (General View)
Adapters (Detailed View) The Adapters detailed view groups status information about a specific adapter under three tabs, as follows:
Viewing the Status of Interfaces 39

Smart Media Software Configuration Guide 2 • Configuring VoIP Interfaces
Hardware The Hardware status screen displays detailed information about the Smart Media unit, such as the software version, the firmware version, and the configuration state. From this view, the OAM target state can be modi fied from enabled to disabled, and the option to reboot the adapter or not can be changed.
Figure 34. Adapters (Detailed View) > Hardware
Sensors The Sensors status screen displays detailed information about the temperature and voltage recorded by various sensors located inside the Smart Media unit chassis.
Figure 35. Adapters (Detailed View) > Sensors
Viewing the Status of Interfaces 40

Smart Media Software Configuration Guide 2 • Configuring VoIP Interfaces
Licensed Features The Licensed Feature status screen displays detailed information about licensed features. A zero in the 'Licensed feature cnt' column means that the Smart Media unit does not have access to the feature. A value of 1 or more indicates the quantity purchased. A number in the 'Maximum feature cnt' column indicates the maximum amount of a licensed feature that can be purchased.
Figure 36. Adapters (Detailed View) > Licensed Features
IP Interfaces (Detailed View) The IP Interfaces status screen displays detailed information about a specific IP interface. This view displays the state of the link, its activity, and configuration settings.
Figure 37. IP Interfaces (Detailed View)
Viewing the Status of Interfaces 41



Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
The following sections describe a typical configuration scenario for an ISDN to SIP gateway. This type of installation allows for the transfer of information from traditional ISDN signaling to SIP protocol for VoIP applications. Please follow each step one after another as these are listed in logical order.
Refer to the following sections to configure the SmartNode for an ISDN to SIP gateway:
After completing the setup process, remember to activate the con figuration. Refer to “Activating the Configuration” on page 33 for more information.
Once you are logged on to the Web Portal, you should make a copy of the default configuration, so as not to alter the original. Should you need to restore the default system configuration, the original file will still be avail able.
Figure 38. Global > Configurations
Overview 44

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Figure 39. Configuration List
Figure 40. Name and Copy a Configuration File
Figure 41. Successful Configuration Copy
Creating a New Configuration 45

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Allocating physical interfaces involves creating a new line interface and creating a new line service.
Creating a new line interface Line interface is a generic term for TDM physical interfaces. The SmartNode 10200 Series supports three types of physical interfaces: T1/E1/J1 interfaces, DS3 interfaces, and Oc3/STM1 interfaces.
To create a new line interface:
Figure 42. TDM Interfaces > Line Interfaces
Figure 43. Line Interface List
– Enter a name for the interface
– Set a type for the interface
– Set a local index for the line
– Select a length and an encoding scheme
Allocating Physical Interfaces 46

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Figure 44. Create New Line Interface
Figure 45. Confirmation Message for New Line Interface
Understanding Parameters for Line Interfaces
Table 2. Configuration Parameters for New Line Interfaces
Name Used by the Web Portal to indicate a specific object or string in the system
Type Defines the type of line interface: E1/DS3/T1/J1/STM1/OC3
Local Index Assigns an integer to represent an object
Length Indicates the physical length of a line: Short/Long/Autodetect/Monitoring
Encoding Sets an encoding scheme for a line interface. Values depend on the interface type:
HDB3/AMI B3ZS B8ZS/AMI/AMI CLEAR (None)
Allocating Physical Interfaces 47

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Creating a new line service You must create a new line service for your line interface. A line service defines the payload type of a line inter face or another line service. The line service chain stops when it reach the E1/J1/T1 line service. The E1/J1/T1 line services are also known as trunks or spans.
To create a new line service:
Figure 46. TDM Interfaces > Line Interfaces
Figure 47. Line Interface List
Figure 48. Editing a Line Interface to Create a New Service
– Enter a name for the new line
– Select an available local index, from the drop-down box
– Select appropriate framing and loopback modes
Allocating Physical Interfaces 48

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Figure 49. Create New Line Service
Figure 50. Line Services List
Allocating Physical Interfaces 49

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Understanding Parameters for Line Services
Table 3. Configuration Parameters for New Line Services
Name Used by the Web Portal to indicate a specific object or string in the system
Local Index Assigns an integer to represent an object
Framing Sets a framing type for a line service. Select from: AUTO (typical for E1)/STD/MFRAME/SF/ESF (typical for T1)/SLC96
Loopback Used to set a loopback state for a line service. Refer to Table 4 for details.
Table 4. Loopback Types
Loopback Type Description Behavior Use
All traffic is received and sent on the line Always
LINE Analog Line Loopback
All received traffic is re-routed on the transmit line. The clock and data recovered from the line inputs are routed back to the line outputs of the analog transceiver bypassing the framer modules.
First step in testing a physical connection
PAYLOAD Digital Line Loopback
All received traffic is re-routed on the transmit line.The clock and data recovered from the line inputs are routed back to the line outputs after the deframer/framer.
Second step in testing a physical connection. This tests the framer configuration.
This forces the transmit line to stop sending. This is the second-best thing to disconnecting the line interface physi cally.
LOCAL Local Loopback All received traffic is dropped. The traffic sent
Never. Used for inter nal testing only
is re-routed internally.
Creating an IP port range After you have properly allocated all of your system's physical interfaces, you must create a new IP port range.
Allocating Physical Interfaces 50
NONE Normal Operation · GENERATE_LOS Generate Loss · of Signal

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Figure 52. Editing Port Ranges
– Enter a name for the port range
– Select an IP interface
– Enter a port min value (must be at least 1024)
– Enter a port max value
Figure 53. Creating a New Port Range
Figure 54. Confirmation Message for Port Range
Understanding Parameters for IP Port Ranges
Table 5. Configuration Parameters for New IP Port Ranges
Name Used by the Web Portal to indicate a specific object or string in the system
IP Interface Identifies an IP interface that is to be associated with the structure being created
Port Min Sets a minimum value for an IP port range. Since only even-numbered ports will be used to send RTP over, it is recommended that the Port Min value be at least 1000
Port Max Sets a maximum value for an IP port range. Since only even-numbered ports will be used to send RTP over, it is recommended that the Port Min value be at least 1000. Ex.: 10000-20000 --> 5000 connections
Allocating Physical Interfaces 51

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Integrated Systems Digital Network (ISDN) is a circuit-switched telephone system that integrated voice and data on the same lines. The Smart Media system can be configured to provide an ISDN signaling stack on the trunks of one or more units to meet system configuration requirements. In order to configure ISDN-PRI sig naling for your system, you must create a new ISDN stack.
To create a new ISDN stack:
Figure 55. Signaling > ISDN
Figure 56. ISDN Stack List
– Verify that the box labeled Enabled is checked
– Enter a name for the new ISDN stack
– Select a variant to associate with the stack
– Determine whether the stack will operate on the user side, or the network side
– Select a primary D-channel line service
Configuring ISDN-PRI Signaling 52

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Figure 57. Create New ISDN Stack
Figure 58. Confirmation Message for New ISDN Stack
Table 6. Configuration Parameters for New ISDN Stacks
Enabled Indicates whether an object is currently implemented or not
Name Used by the Web Portal to indicate a specific object or string in the system
Line Service Indicates which TDM line service is to be associated with the object being created
Variant Indicates the protocol variant to be used on a signaling stack. Possible values: 4ESS/AUS/5ESS/DMS/NI2/HONG-KONG/JAPAN INS
Side Defines each side of an ISDN stack. Possible values: Network/User
Configuring ISDN-PRI Signaling 53

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
The clock is a necessary component of a TDM network. Synchronizing your system on the right clock, allows it to offer good sound quality. It is recommended that you configure an external clocking source for your sys tem.
Figure 60. External System Clock Reference List
– Select the appropriate hardware adapter
– Select a clock reference type (in this example, Line Service was chosen)
– Select a clock reference source (in this example "Line_Service_00")
Figure 61. Creating New External System Clock
Figure 62. Confirmation Message for System Clock
Defining a Clocking Source 54

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Table 7. Configuration Parameters for the Clocking Source
Adapter Defines the Smart Media hardware adapter for which a new object is created
Clock Reference Type Defines which type of object is to be used as an external clocking source. Possible values: Line Service/Bits Port/Sonet SDH
Clock Reference Source Defines which object is to be used as an external clocking source.
Possible values available depend on the selected Clock Reference Type.
Smart Media provides support for signaling using the Session Initiation Protocol, more commonly known as SIP, for voice over IP (VoIP) communications. SIP may be used in conjunction with various voice codecs for the media component of a call. Smart Media supports SIP signaling concurrently with SS7, ISDN and other signaling protocols. SIP signaling stacks are configured for IP applications and for each Smart Media unit requiring SIP signaling.
Based upon your system requirements, you can configure a SIP stack to carry signaling traffic over multiple transport servers, which are IP endpoints comprised of: protocol type (TCP/UDP), port number, IP interface, IP address, IP name, and SAPs.
Refer to the following sections to configure SIP signaling for your Smart Media device:
Creating a SIP stack In order to configure SIP signaling for your system, you must first create a SIP stack.
Configuring SIP Signaling 55

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Figure 64. SIP Configuration List
– Verify that the box labeled Enabled is checked
– Enter a name for the stack
– Select a virtual adapter
Figure 65. Creating a New SIP Stack
Figure 66. Confirmation Message for SIP
Configuring SIP Signaling 56

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Understanding Parameters for SIP Stacks
Table 8. Configuration Parameters for New SIP Stacks
Enabled Indicates whether an object is currently implemented or not
Name Used by the Web Portal to indicate a specific object or string in the system
Virtual Adapter Defines the Smart Media hardware adapter for which a new object is being created
Creating a SIP transport server After you have created a SIP stack, you must create a new SIP transport server for your configuration.
Figure 68. Edit SIP Configuration List
Figure 69. Transport Servers List
– Enter a name for the server
– Select an appropriate port type
– Select a hardware adapter
– Select an appropriate IP interface
Configuring SIP Signaling 57

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Figure 70. Creating a New SIP Transport Server
Figure 71. Confirmation Message for SIP Transport Server
Understanding Parameters for SIP Transport Servers
Table 9. Configuration Parameters for SIP Transport Servers
Name Used by the Web Portal to indicate a specific object or string in the system
Port Type Identifies the type of IP port used by a SIP transport server. Possible values: UDP/TCP
Adapter Defines the Smart Media hardware adapter for which a new object is being cre ated
IP Interface Identifies an IP interface that is to be associated with the structure being created
Configuring SIP Signaling 58

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Creating a SIP service access point (SAP) After you have created a SIP stack and transport server, you must create a new service access point (SAP) for your configuration. The Service Access Point is used to bind the SIP stack with a transport server. Depending on the system configuration, multiple SAPs can be configured.
To create a new SIP SAP:
Figure 73. Edit SIP Configuration List
Figure 74. Service Access Points (SAP) List
– Enter a name for the SAP
Figure 75. Creating a New SAP
Figure 76. Confirmation Message for SIP SAP
Configuring SIP Signaling 59

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
– Select a transport server from the list of available servers
– Associate this configuration by clicking the "<<" button
– The transport server will now appear in the list to the left:
Figure 77. Associating Transport Servers
Understanding Parameters for SIP SAPs
Table 10. Configuration Parameters for SIP SAPs
Name Used by the Web Portal to indicate a specific object or string in the system
This section describes how to access and configure tone detection profiles, and also how to write and submit the code for the Session Description Protocol (SDP).
Accessing Profiles and Validating Settings You must access your system's default sound codec and tone detection profiles, in order to validate whether or not they are configured correctly.
Configuring Codecs and Tone Detection 60

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Figure 79. Edit Profile List
– Select an appropriate DTMF relay scheme from the list
– Add the chosen scheme by clicking the "<<" button
Figure 80. DTMF Relay Scheme List
The configuration will not be saved if the text box designed to con tain the session definition protocol (SDP) is left empty. The SDP must be written in section “Managing the Session Description Pro tocol (SDP)” on page 62.
Configuring Codecs and Tone Detection 61
– Click Save

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Managing the Session Description Protocol (SDP) You can specify the Profile SDP Description to define which voice codecs are supported in the Network Access Point (NAP) using this Profile.
Here is the default Profile SDP Description:
m=audio 0 RTP/AVP 0 8 4 96 97 18 98 13 a=rtpmap:96 iLBC/8000 a=rtpmap:97 iLBC/8000 a=fmtp:97 mode=20 a=rtpmap:98 telephone-event/8000
Each line of the Profile SDP Description consists of text of the form =. is always exactly one character and is case-significant. is a structured text string whose format depends on . It also will be case-significant unless a specific field defines otherwise. Whitespace is not permitted either side of the `=' sign. In general is either a number of fields delimited by a single space character or a free format string.
In our Profile SDP Description, only 2 are used.
Media Announcement The format of media announcement is as follows:
m=
- the payload type number for static payload types
- the payload type number along with additional encoding information for dynamically allocated payload
types.
The payload type, which is carried in the actual RTP packet header, is used to identify the type of codec infor mation carried in the packet. A list of payload type values for each codec is defined within RFC3551. Unfortu nately, since the payload type field is only 7 bits-wide, all codecs cannot have a permanent payload type value understood universally by all VoIp systems. Therefore, some codecs have dynamic values that need to be nego tiated through a call control or session control protocol such as SIP before the actual RTP session can take place.
Configuring Codecs and Tone Detection 62

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Table 11 shows the list of codec payload type values per RFC3551:
Table 11. Codec Payload Type Values
Codec Payload Type Value
G.711 uLaw 0
G.711 aLaw 8
G.729AB 18
G.726-40 dynamic
G.726-32 2 or dynamic (depends on network)
G.726-24 dynamic
G.726-16 dynamic
G.729EG dynamic
When you use dynamic payload types, you need to specify the additional encoding information using the attribute for media announcement.
Attribute for Media Announcement A media description may have any number of attributes ("a=" fields) which are media specific. The format of attribute is as follows.
a=:
Here are some examples of attributes:
Dynamic payload type. You specify the additional encoding information for dynamic payload type in the fol lowing format:
a=rtpmap: /[/]
For audio streams, may specify the number of audio channels. This parameter may be omitted if the number of channels is one provided no additional parameters are needed.
Other media specific attribute. The use of other media specific attributes depends on the specification of the RTP payload format for the specific media type. Here are some example of attributes.
a=fmtp:
This attribute allows parameters that are specific to a particular format to be conveyed in a way that SDP doesn't have to understand them. The format must be one of the formats specified for the media. Format-spe
Configuring Codecs and Tone Detection 63

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
cific parameters may be any set of parameters required to be conveyed by SDP and given unchanged to the media tool that will use this format.
a=ptime:
This gives the length of time in milliseconds represented by the media in a packet. This is probably only mean ingful for audio data. It should not be necessary to know ptime to decode RTP or vat audio, and it is intended as a recommendation for the encoding/packetisation of audio. It is a media attribute, and is not dependent on charset.
Examples. Here are some examples of the attributes found in the default profile SDP description:
a=rtpmap:97 iLBC/8000 a=fmtp:97 mode=20
The above defines iLBC codec of 8000/sec sample rate with 20ms frame size.
a=rtpmap:98 telephone-event/8000
The above defines the DTMF relay using RFC2833.
Here is another example, enabling Voice Activity Detection (VAD) for G.711 ulaw, G.711 alaw, G.723.1a and G.729b, in addition to telephony events:
m=audio 0 RTP/AVP 0 8 4 18 98 13 a=rtpmap:0 PCMU/8000 a=rtpmap:8 PCMA/8000 a=rtpmap:4 G723/8000 a=fmtp:4 bitrate=6300;annexa=yes a=rtpmap:18 G729/8000 a=fmtp:18 annexb=yes a=rtpmap:98 telephone-event/8000 a=fmtp:98 0-15 a=rtpmap:13 CN/8000
This one is for a direct SIP INVITE with T.38. This can be useful if you know this route will always be with fax. It also doesn't require any IVR resources to detect the fax tones:
m=image 0 udptl t38 a=T38FaxVersion:0 a=T38MaxBitRate:14400 a=T38FaxFillBitRemoval:0 a=T38FaxTranscodingMMR:0 a=T38FaxTranscodingJBIG:0 a=T38FaxRateManagement:transferredTCF a=T38FaxMaxBuffer:400 a=T38FaxMaxDatagram:400 a=T38FaxUdpEC:t38UDPRedundancy
Configuring Codecs and Tone Detection 64

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
The next step in configuring an ISDN-SIP gateway is to configure the Network Access Points (NAPs).
Allocating an ISDN NAP 1. Click NAP in the navigation panel:
Figure 82. Edit NAP List
– Enter a name for the NAP
Figure 83. Creating a New ISDN NAP
Figure 84. Confirmation Message for New NAP
Configuring Network Access Points (NAPs) 65

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
– Select a stack from the ISDN stack list
– Click the "<<" button to associate it with the NAP
Figure 85. Associating ISDN Stacks with NAPs
Understanding Parameters for ISDN NAPs
Table 12. Configuration Parameters for NAPs
Name Used by the Web Portal to indicate a specific object or string in the system
Allocating a SIP NAP 1. Click NAP in the navigation panel:
Figure 87. Edit NAP List
Configuring Network Access Points (NAPs) 66

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
– Enter a name for the NAP
Figure 88. Creating a New SIP NAP
Figure 89. Confirmation Message for New NAP
– Select a SIP SAP from the service access points list
– Click the "<<" button to associate it with the NAP
Figure 90. Associating SIP SAPs with NAPs
Configuring Network Access Points (NAPs) 67

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Understanding Parameters for SIP NAPs
Table 13. Configuration Parameters for SIP NAPs
Name Used by the Web Portal to indicate a specific object or string in the system
Filter by destination address
Checked: Filters out incoming calls that do not have a proxy as their source address Unchecked: NAP may accept calls from any source IP
Filter by local port Checked: Filters out calls that are not coming in on this local port Unchecked: NAP may accept calls on any configured local port
Local port Indicates a port number to use when filtering by local port
Register to proxy Indicates that a NAP should be registered to a proxy server
Address to register Indicates the address of a record the NAP uses when registering to a proxy server
Poll remote proxy Enables proxy polling, in order to detect available proxies
Map any response to available status
Set to consider proxies as available on any response class (2xx/3xx/4xx). This is required when a peer proxy does not support being polled with the OPTIONS method.
183 triggers call process Set to change the behavior of an inbound SIP 183 message from triggering a call alert signal to triggering a call progress signal.
Realm Determines an authentication realm. This is typically a description of the computer or system being accessed, and for which user authentication will be provided.
User Submits a user name for authentication
Password Submits the password for a user name for authentication
Configuring Network Access Points (NAPs) 68

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
You must set up call routing for your Smart Media system. Call routing refers to the ability to route calls based on criteria such as origin, destination, time of day, service provider rates, and more.
Creating a primary call route 1. Click Routes in the navigation panel:
Figure 91. Configurations > Routes
Figure 92. Static Routes List
– Enter a RoutesetName for the route
– Select a NAP, or leave empty to match calls from any NAP
– Select a Remapped NAP
Creating Call Routing Rules 69

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Figure 93. Creating a New Route
Figure 94. Confirmation Message for New Route
Creating Call Routing Rules 70

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Understanding Parameters for Call Routing
Table 14. Configuration Parameters for Static Routes
Routeset Name Used by the Web Portal to indicate a specific object or string in the system
Called Sets a filter to which each called number of an incoming call will be compared to see if the call matches the route. The called number can be a fixed number but it can also be a regular expression (regex).
Calling Sets a filter to which each calling number of an incoming call will be compared to see if the call matches the route. The called number can be a fixed number but it can also be a regular expression (regex).
NAP Identifies a network access point (NAP) to be associated with a new object
Remapped NAP Defines which outgoing NAP will be selected when a particular route is used
Creating Call Routing Rules 71

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
General and detailed status information about the TDM lines, also referred to as Adapters is accessible from the TDM Lines tab of the Global Status view.
General View The TDM Lines general view, shown below, provides information about the physical line interfaces of a TDM module and the line services that they carry. From this view you can know the status of line interfaces and line services by seeing if they are up, down, defective, or in an alarmed state. Selecting an active link will display the detailed view for line interfaces and line services.
Viewing the Status of the TDM Lines 72

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Line Interface The detailed status view for each line interface allows you to reset status, or view extended status.
Line Service The detailed status view for each line service allows you to reset the service's status, or to set the loopback mode in the loopback drop-down box.
Viewing the Status of the TDM Lines 73

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
General and detailed status information about the ISDN stack is accessible from the ISDN tab of the Global Status view.
General View The ISDN general view, shown below, lists the ISDN stacks and indicates which are up (online) or down (offline). This general view provides links to a detailed status view for the ISDN stacks on a specific Smart Media device.
Viewing the Status of the ISDN Stack 74

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
Timeslot States Diagram This diagram indicates the timeslot slates for every line service associated with the NFAS stack.The legend below indicates whether the timeslot is:

Figure 99. Timeslot States Diagram
Viewing the Status of the ISDN Stack 75

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
General and detailed status information about the SIP stack is accessible from the SIP tab of the Global Status view.
General View The SIP general view, shown below, provides a listing of the SIP stacks and the Smart Media devices on which they reside as well as SIP decode/encode failure counters. Selecting a SIP stack link from this view displays its detailed information.
Viewing the Status of the SIP Stack 76

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
SIP Stack Configuration Status The Stack tab of the SIP Configuration status screen, shown below, displays the detailed status counters of one SIP stack. Furthermore, the counters may be reset from this screen. To reset the counters of this screen:
The SIP SAPs tab of the SIP Configuration status screen, shown below, lists the configured SAPs of one SIP stack, as well as call transmit and receive counters. Selecting a SAP link from this screen displays its detailed view. Furthermore, the counters may be reset from this screen:
Viewing the Status of the SIP Stack 77

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
SIP SAP Detailed Status The SIP SAP status screen, shown below, displays the call transmit and receive counters. The counters may be reset from this screen.To reset the counters of this screen
Viewing the Status of the SIP Stack 78

Smart Media Software Configuration Guide 3 • Configuring an ISDN-SIP Gateway
General and detailed status information about the Network Access Points (NAPs) are accessible from the NAP tab of the Global Status view.
General View The NAP general view, shown below, provides a listing of the configured NAPs. In addition, the number of assigned circuits, idle circuits, and the incoming/outgoing call counters are indicated for each NAP.
Figure 104. NAP Status
Viewing the Status of the NAPs 79



Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
The following sections explain how to configure the SS7 signaling protocol. Refer to the following sections to configure the SmartNode for SS7:
The Message Transfer Part Level 2 (MTP2) provides the data link layer functionality within the OSI model and is a service provider to the MTP3 link layer. The steps to configuring the MTP2 layer include creating a configuration and creating a MTP2 link.
Creating an MTP2 Configuration 1. Select MTP2 from the navigation panel:
Figure 105. Signaling > MTP2
– Enter a name for the configuration
Figure 106. Creating the New MTP2 Configuration
Figure 107. Successful Configuration Message
– Click Save · Overview 82

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Understanding Parameters for MTP2 Configurations
Table 15. Configuration Parameters for New MTP2 Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Creating MTP2 Links Now that you have created an MTP2 configuration, you must create the necessary MTP2 links. An MTP2 link is used to connect the MTP2 physical layer to a line service carrying SS7 signaling.
To create an MTP2 link:
Figure 108. MTP2 Link in MTP2 Configuration Window
– Enter a name for the new link
– Select a connection mode
– Select a line service
– Assign timeslots to the link
– Select a protocol type
– Select a DPC length
– Select a timeslot rate
Configuring the MTP2 Layer 83

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Figure 109. Creating a New MTP2 Link
Figure 110. Successful Link Message
Configuring the MTP2 Layer 84

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Understanding Parameters for MTP2 Links
Table 16. Configuration Parameters for New MTP2 Links
Name Used by the Web Portal to indicate a specific object or string in the system
Connection Mode Defines the type of connection used in an SS7 system. Possible values: Normal/Hsl (High-speed link)
Line Service Indicates which TDM line service is to be associated with the object being created
Timeslots Allows the selection of individual voice or data channels of a line. Values for this parameter are listed as check boxes (ranging from 1-24). Individual timeslots can be selected by checking the boxes. Occasionally, all timeslots can be selected at once by clicking the Select All link.
Protocol Type Identifies the SS7 protocol variant that will be used with a particular object. The appropriate protocol variant depends on the user's geographical location. Values are chosen from a drop-down list. The Protocol Type parameter can take on the following values, depending on the object being configured:
TELCORDIA ANSI88 ANSI92 ANSI95
SINGAPORE Q767 TTC NTT
CHINA ETSI ETSIV3 UK
DPC Length Sets a format for the Destination Point Code (DPC) used by an object. Possible values: 14bits format=3.8.3/16bits format=7.4.5/24bits format=8.8.8
Timeslot Rate Indicates the data rate for timeslots on a line. Possible values: 64 Kbps/56 Kbps/48 Kbps
Configuring the MTP2 Layer 85

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
The Message Transfer Part Level 3 (MTP3) provides message routing between signaling points in an SS7 net work. Refer to the following sections for the steps to configuring the MTP3 layer:
Creating an MTP3 Configuration 1. Select MTP3 from the navigation panel:
Figure 111. SS7 > MTP3
– Enter a name for the MTP3 configuration
– Make sure the Enabled and SSf Validation boxes are checked
– Select SP as the signaling point type
– Select a restart procedure
Figure 112. Creating the New MTP3 Configuration
Configuring the MTP3 Layer 86

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Figure 113. Successful Configuration Message
Understanding Parameters for MTP3 Configurations
Table 17. Configuration Parameters for New MTP3 Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Enabled Indicates whether or not an object is to be implemented or not
Ssf Validation Allows the activation of sub-service field validation for an MTP3 configuration
Signaling Point Type Indicates the intended purpose of an SS7 MTP3 layer object. Possible values: SP (Signaling Point)/STP (Signal Transfer Point)
Restart Procedure Indicates the standard by which a configuration will carry out a restart process. Possible values: None/ITU88/ITU92/ANSI
Creating an MTP3 Network After you have created your system's MTP3 configuration, you must create a new MTP3 network. An MTP3 network is created to define its point codes, link sets and routes. This can be done from the MTP3 configura tion information panel
To create an MTP3 network:
Figure 114. MTP3 Networks in MTP3 Configuration Window
– Enter a name for the network
– Select a sub service field
– Select a link type
– Select the SS7 DPC length
Figure 115. Creating a New MTP3 Network
Configuring the MTP3 Layer 87

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Figure 116. Successful Network Message
Understanding Parameters for MTP3 Networks
Table 18. Configuration Parameters for New MTP3 Networks
Name Used by the Web Portal to indicate a specific object or string in the system
Sub Service Field Differentiates between national and international signals in MTP3 networks. Possible values: International/National/Nat. Reserved/Inter. Reserved
Link Type Sets a protocol type for signaling links. Possible values: ANSI/ITU/CHINA/ANSI96
SS7 DPC Length Sets a format for the Destination Point Code (DPC) used by an object. Possible values: 14bits format=3.8.3/16bits format=7.4.5/24bits format=8.8.8
Creating an MTP3 Point Code After you have configured your MTP3 network, you must create point codes for your system. Point codes are used to define the Smart Media system network, the adjacent network and the target network so that calls are properly routed from one network to the next.
To create SS7 originating (OPC) and destination (DPC) point codes:
Figure 117. SS7 > Point Codes
Figure 118. Point Codes
Configuring the MTP3 Layer 88

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
– Enter a name for the point code
– Select a point code type (select type-specific parameters)
– Select a point code length (14, 16, 24 bits)
– Enter a point code
Figure 119. Creating the New MTP3 Point Code
Figure 120. Successful Point Code Message
Understanding Parameters for SS7 Point Codes
Table 19. Configuration Parameters for New Point Codes
Name Used by the Web Portal to indicate a specific object or string in the system
Type Defines the type of point code being created. Possible values: OPC/DPC/Mask
DPC Length Sets a format for the Destination Point Code (DPC) used by an object. Possible values: 14bits format=3.8.3/16bits format=7.4.5/24bits format=8.8.8
Point Code Defines a point code by assigning it numerical values.
Configuring the MTP3 Layer 89

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Creating an MTP3 Linkset After you have created an MTP3 network, you are ready to create an MTP3 linkset. This can be done through the MTP3 network configuration window. A linkset is used to logically combine multiple MTP3 links going to the same DPC into a single entity. One linkset could be the links between a point code identifying the Smart Media SS7 node and a point code identifying the adjacent SS7 equipment.
To create an MTP3 linkset:
Figure 121. MTP3 Linksets
– Enter a name for the linkset
– Select an origin point code (OPC)
– Select an adjacent point code
– Make sure the desired state is set to Active
Figure 122. Creating the New MTP3 Linkset
Figure 123. Successful Linkset Message
Configuring the MTP3 Layer 90

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Understanding Parameters for MTP3 Linksets
Table 20. Configuration Parameters for New MTP3 Linksets
Name Used by the Web Portal to indicate a specific object or string in the system
Origin Point Code Associates an object with an originating point code (OPC)
Adjacent Point Code Associates an object with an adjacent point code
Desired State Indicates whether an object is to be active or inactive upon creation Possible values: Active/Inactive
Creating MTP3 Links After you have created an MTP3 linkset, you must create MTP3 links for your system. An MTP3 link is used to connect with an MTP2 link; they are connected in a one-to-one fashion. To create an MTP3 link:
Figure 124. MTP3 Links
– Enter a name for the link
– Under Type of link to bind, select MTP2
– Select an MTP2 link
Configuring the MTP3 Layer 91

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Figure 125. Creating the New MTP3 Link
Figure 126. Successful MTP3 Link Message
Configuring the MTP3 Layer 92

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Understanding Parameters for MTP3 Links
Table 21. Configuration Parameters for New MTP3 Links
Name Used by the Web Portal to indicate a specific object or string in the system
Type of Link to Bind Indicates the type of link to bind when creating an MTP3 link Possible values: MTP2/M2PA/M2UA
MTP2 Selects an MTP2 link to bind to an object
M2PA Selects an M2PA (MTP2 Peer-to-Peer Adaptation Layer) link to bind to an object
M2UA Selects an M2UA (MTP2 User Adaptation Layer) link to bind to an object
Creating an MTP3 Route MTP3 routes are built to route traffic from previously created point codes using linksets. One route is created for each previously defined point code.
To create an MTP3 route:
Figure 127. MTP3 Routes
– Enter a name for the route
– Select a point code for the route
– Select a restart procedure
– Select a point type
– Check the Route to Adjacent box, if this route is directed to an adjacent network
Configuring the MTP3 Layer 93
Links

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Figure 128. Creating the New MTP3 Route
Figure 129. Successful MTP3 Route Message
– Select a linkset from the list provided at the bottom of the route configuration window
– Click the "<<" button to associate the linkset with the newly created route
Figure 130. Associating Routes with Linksets
Configuring the MTP3 Layer 94

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Understanding Parameters for MTP3 Routes
Table 22. Configuration Parameters for New MTP3 Routes
Name Used by the Web Portal to indicate a specific object or string in the system
Point Code Associates a point code with the MTP3 route
Restart Procedure Indicates the standard by which a configuration will carry out a restart process. Possible values: None/ITU88/ITU92/ANSI
Point Type Indicates the intended purpose of an SS7 MTP3 layer object. Possible values: SP (signaling Point)/STP (Signal Transfer Point)
Route to Adjacent Used when an MTP3 route is directed toward an adjacent network
The ISDN User Part (ISUP) is the highest layer in the SS7 signaling stack and is responsible for the handling of calls.. Refer to the following sections for the steps to configuring the ISUP layer:
Creating an ISUP Stack After you have configured the MTP3 layer of your SS7 system, you must create an ISDN user part stack. To create an ISUP stack:
Figure 131. SS7 > ISUP
Figure 132. ISUP Stack List
Configuring the ISUP Layer 95

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
– Make sure the box labeled Enabled is checked
– Enter a name for the stack
– Select a primary hardware adapter
– Select a secondary hardware adapter
Figure 133. Creating the New ISUP Stack
Figure 134. Successful ISUP Stack Message
Understanding Parameters for ISUP Stacks
Table 23. Configuration Parameters for New ISUP Stack
Name Used by the Web Portal to indicate a specific object or string in the sys tem
Primary Hardware Adapter Identifies a main Smart Media hardware device to run an ISUP stack
Secondary Hardware Adapter Identifies a secondary (backup) Smart Media hardware device to run
Configuring the ISUP Layer 96
an ISUP stack

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Creating an ISUP Network After you have created an initial ISUP stack, you must create a new ISUP network. The ISUP network tells the ISUP protocol layer about a collection of SS7 nodes that are accessible through MTP3 or M3UA. Based upon your system configuration, one or more ISUP networks are created. Repeat this section for as many networks as you require.
To create an ISUP network:
Figure 135. Editing ISUP Networks
– Enter a name for the network
– Select MTP3 or M3UA as the type of network to bind
– Select a MTP3 network or a M3UA network
Figure 136. Creating the New ISUP Network
Figure 137. Successful ISUP Network Message
Configuring the ISUP Layer 97

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Understanding Parameters for ISUP Networks
Table 24. Configuration Parameters for New ISUP Network
Name Used by the Web Portal to indicate a specific object or string in the system
Type of Network to Bind Indicates the type of network to associate with an ISUP Network Possible values: MTP3/M3UA
MTP3 Network Associates an MTP3 network with a higher level network in an SS7 system
M3UA Network Associates an MTP3 network with a higher level network in an SS7 system
Creating an ISUP User Part After you have created your ISUP network, you must create a new ISUP user part. The user part is the con tainer for the multiple ISUP interfaces. One user part is required for each protocol variant.
Multiple ISUP user parts can be instantiated within a single ISUP protocol layer. This allows a user application to interface with multiple SS7 ISUP protocol variants at the same time. Only one ISUP user part is required for a specific variant as it can be assigned to multiple ISUP networks.
A user part can easily be seen as a protocol variant that a host application wants to use on the SS7 network.
To create an ISUP user part:

Figure 138. Editing Userparts
– Enter a name for the user part
– Select a protocol variant (depending on location)
– Select an MTP3 sub service field (the same that was previously set for MTP3)
– Select an address indicator type
– Select a Numbering Plan
Configuring the ISUP Layer 98
Networks

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Figure 139. Creating the New ISUP User Part
Figure 140. Successful ISUP User Part Message
Understanding Parameters for ISUP User Parts
Table 25. Configuration Parameters for New ISUP User Part
Name Used by the Web Portal to indicate a specific object or string in the system
Protocol Type Identifies the SS7 protocol variant that will be used with a particular object. The appropriate protocol variant depends on the user's geographical location. Values are chosen from a drop-down list. The Protocol Type parameter can take on the following values, depending on the object being configured:
TELCORDIA ANSI88 ANSI92 ANSI95
SINGAPORE Q767 TTC NTT
CHINA ETSI ETSIV3 UK
Sub Service Field Differentiates between national and international signals in MTP3 networks. Possible values: International/National/Nat. Reserved/Inter. Reserved
Address Indicator Type Assigns a default address value in ISUP user parts, when unspecified.
Numbering Plan Assigns a default numbering plan in ISUP user parts, when unspecified. Possible values:
Configuring the ISUP Layer 99

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Creating an ISUP Interface After you have created an ISUP user part to contain them, you must create new ISUP interfaces.
The ISUP interface creates a binding within the ISUP layer of a particular variant, a specific network, and an OPC/DPC pair to which circuits can be assigned. The ISUP interface contains the circuit identifier codes (CICs) within the ISUP user part. One interface is created for each similar grouping of CICs within one user part protocol variant.
To create an ISUP interface:
Figure 141. Editing ISUP Interfaces
– Enter a name for the interface
– Select an ISUP user part
– Select an ISUP network
– Select a trunk type
– Select an originating point code (OPC)
– Select a destination point code (DPC)
Figure 142. Creating the New ISUP Interface
Figure 143. Successful ISUP Interface Message
Configuring the ISUP Layer 100

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Understanding Parameters for ISUP Interfaces
Table 26. Configuration Parameters for New ISUP Interface
Name Used by the Web Portal to indicate a specific object or string in the system
ISUP User Part Associates an ISUP user part with an ISUP interface
ISUP Network Associates an ISUP network with an ISUP interface
OPC Associates an object with an originating point code (OPC)
DPC Associates an object with a destination point code (DPC)
Configuring the ISUP Layer 101

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
General and detailed status information about the SS7 MTP2 stack is accessible from the SS7 MTP2 tab of the Global Status view.
General View The SS7 MTP2 general view provides information about the health of the MTP2 links. From this view you can know the status of MTP2 links by seeing if they are up or down. Selecting an active link will display the detailed view for that line.
MTP2 Link Detailed Status The MTP2 Link detailed status screen enables you to view the state of an MTP2 link and to modify the datalink state value for testing purposes.
Viewing the Status of SS7 MTP2 Links 102

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
MTP2 Link Listing The MTP2 Link listing, shown below, displays an expanded listing of each MTP2 link. In addition to indicat ing whether a link is up or down, this listing provides supplemental information. Selecting an MTP2 link from this listing displays its detailed information. For a full listing of all MTP2 Links, select MTP2 from the naviga tion panel, and choose the Status tab in the control panel.
Viewing the Status of SS7 MTP2 Links 103

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
General and detailed status information about the SS7 MTP3 stack is accessible from the SS7 MTP3 tab of the Global Status view.
General View The SS7 MTP3 general view, shown below, provides information about the health of the MTP3 links. From this view you can know the status of MTP3 links by seeing if they are up or down. This general view provides links to other detailed status screens for the MTP3 configuration, its links, linksets, and routes.
Detailed View The SS7 MTP3 detailed view groups status information into four screens, as follows:
Viewing the Status of SS7 MTP3 Links 104

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
MTP3 Stack Status The MTP3 Stack Status, shown below, displays counters for a variety of status messages that in turn are used to indicate the current health of the MTP3 stack. This status screen is accessed from the MTP3 CFG 0 link of the General view, shown in the figure above. Counters may be reset from this screen to determine if a problem per sists.
MTP3 Linkset The Linksets status screen, accessible from a linkset link shown in MTP3 Network Status: Linksets Tab, groups status information under two tabs as follows:
MTP3 Linkset Status: Linksets Tab. The Linkset tab of the MTP3 Network status screen, shown below, dis plays the detailed information of one MTP3 linkset, such as linkset state, configured values, and counters. From this screen the desired linkset state may be set to Active or Inactive, and counters may be reset.
Viewing the Status of SS7 MTP3 Links 105

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
MTP3 Linkset Status: Links Tab. The Links tab of the MTP3 Network status screen, shown below, displays a listing of the MTP3 links that are used by a specific MTP3 Linkset. In the listing, the status of each link is displayed as well as a link congestion timer. Accessing a particular MTP3 Link displays its detailed informa tion.
Viewing the Status of SS7 MTP3 Links 106

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
MTP3 Link The MTP3 Link status screen, shown below, displays the detailed information about one MTP3 link, such as the link state, configured values, and counters. Hovering over fields causes help bubbles to display. For exam ple, in the figure below, an information bubble is displayed for a counter of the number of invalid Protocol Data Units (PDUs) received.
To modify the Desired Locally Inhibited state:
Viewing the Status of SS7 MTP3 Links 107

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
General and detailed status information about the SS7 ISUP stack is accessible from the SS7 ISUP tab of the Global Status view.
General View The SS7 ISUP general view, shown below, lists ISUP stacks and indicates which are active, in standby, or out of service (Oos). In addition, the SS7 ISUP general view lists ISUP interfaces and indicates which are available, congested, or unavailable. This general view provides links to detailed status views of the ISUP stacks and net works.
Viewing the Status of SS7 ISUP Stacks 108

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Detailed View The SS7 ISUP detailed view groups status information into these main screens:
ISUP Stack Status The ISUP Stack status screen groups status information about the ISUP Stack under two tabs, as follows:
ISUP Stack Status: Stack tab. The Stack tab of the ISUP Stack status screen provides the name of the pri mary and optionally secondary Smart Media unit that hosts the ISUP stack and the status.
ISUP Stack Status: Interfaces tab. The Interfaces tab of the ISUP Stack status screen lists the configured ISUP interfaces of the ISUP stack and provides the states of each network as well as their transmit and receive message counters. Selecting an ISUP Interface link displays its detailed information.
Viewing the Status of SS7 ISUP Stacks 109

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
ISUP Interface Status The ISUP Interface status screen groups status information about the interface under two tabs, as follows:
ISUP Interface Status: Interface Tab. The Interface tab of the MTP3 Network status screen, shown below, provides transmit and receive message counters for a specific ISUP interface.
ISUP Interface Status: Circuit Groups Tab. The Circuit Groups tab of the ISUP Stack status screen, shown below, lists the configured circuits groups for a specific ISUP interface. In addition, this screen provides status and counters for each circuit group. Selecting a circuit group link displays its detailed information.
Viewing the Status of SS7 ISUP Stacks 110

Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Circuit Group Status The Circuit Group status screen displays detailed information for one circuit group, such as status counters and configured values. From this screen, the desired group state may be set to Unblocked, Blocked, or Default.
Table 27. Circuit Group Status Settings
Circuit Group State Description
Default Lets the system decide the state of the circuit or circuit group. For example, a trunk down will block the circuits.
Blocked Forces a local block condition. No calls can be made on these circuits even if the trunks are up. This function is useful for forcing calls on specific circuits by blocking other circuits in the system.
Unblocked Forces a local unblock condition. This will force the circuits to be unblocked, even if the trunks are down. To be used for testing only.
To modify the desired group state:
Viewing the Status of SS7 ISUP Stacks 111




The Smart Media system enables you to configure SIGTRAN and extend SS7 signaling functionality to the IP network. Smart Media enables you to configure a number of SIGTRAN applications based upon your require ments. Refer to the following sections for configuring SIGTRAN applications:
Overview 115

In this configuration, the SS7 MTP2 layer is replaced by the SIGTRAN M2PA layer which extends MTP2 sig nalling functionality into the IP network. This application is typically used between a Signaling Gateway and an IP Signaling Point, or between two IP Signaling Points. Refer to the following sections to configure an M2PA system:
– “Creating an M2PA SAP” on page 126
– “Creating M2PA Links” on page 127
– “Creating an MTP3 Network” on page 132
– “Creating an MTP3 Linkset” on page 133
– “Creating MTP3 Links (M2PA)” on page 134
– “Creating an MTP3 Route” on page 136
– “Creating an ISUP Network” on page 139
– “Creating an ISUP User Part” on page 141
– “Creating an ISUP Interface” on page 142
– “Creating ISUP CIC Groups” on page 144
– “Creating a NAP (SIGTRAN)” on page 145
Configuring an M2PA System 116

Adding an Adapter When you receive a new system, at least one hardware configuration will have been set in the Smart Media application server, by default. To add other hardware devices, you must use the Smart Media Web Portal. To add one or more additional hardware devices to the Smart Media system configuration, their serial numbers must be registered with the Smart Media application server.
To add a hardware device:
Figure 158. config_patton > Hardware
Figure 159. Hardware List
– Enter a name for the hardware device
– Enter the serial number of the new hardware device (filling in the Serial Number field will cause auto-
completion of the field to occur).
– Select the appropriate hardware device from the Adapter Type field.
– Select Enabled from the Target State field.
Configuring an M2PA System 117

Figure 160. Creating the New Hardware Device
Figure 161. Successful Device Message
Configuring an M2PA System 118

Understanding Parameters for Hardware Adapters
Table 28. Configuration Parameters for New Hardware Adapters
Name Used by the Web Portal to indicate a specific object or string in the system
Serial Defines a product serial number, when creating a new hardware device. Enter ing characters into the Serial field will cause the number to auto-complete.
Adapter Type Specifies the type of hardware device being created, when adding a new adapter. Possible values: TMP/TMS
Sets a maximal delay for calls to terminate normally before an adapter is upgraded
Location Identifies the physical location of a hardware adapter
Description Describes the purpose of a particular hardware adapter
Target State Sets the live state of a hardware adapter. Possible values: Disabled/Probation/Enabled
Creating Line Interfaces Line interface is a generic term for TDM physical interfaces. The SmartNode 10200 Series supports three types of physical interfaces: T1/E1/J1 interfaces, DS3 interfaces, and Oc3/STM1 interfaces.
To create a new line interface:
Figure 162. TDM Interfaces > Line Interfaces
Figure 163. Line Interface List
– Enter a name for the interface
– Set a type for the interface
Configuring an M2PA System 119
Graceful Upgrade Timeout

– Set a local index for the line
– Select a length and an encoding scheme
Figure 164. Create New Line Interface
Figure 165. Confirmation Message for New Line Interface
Understanding Parameters for Line Interfaces
Table 29. Configuration Parameters for New Line Interfaces
Name Used by the Web Portal to indicate a specific object or string in the system
Type Defines the type of line interface: E1/DS3/T1/J1/STM1/OC3
Local Index Assigns an integer to represent an object
Length Indicates the physical length of a line: Short/Long/Autodetect/Monitoring
Encoding Sets an encoding scheme for a line interface. Values depend on the interface type:
HDB3/AMI B3ZS B8ZS/AMI/AMI CLEAR (None)
Configuring an M2PA System 120

Creating Line Services You must create a new line service for your line interface. A line service defines the payload type of a line inter face or another line service. The line service chain stops when it reach the E1/J1/T1 line service. The E1/J1/T1 line services are also known as trunks or spans.
To create a new line service:
Figure 166. TDM Interfaces > Line Interfaces
Figure 167. Line Interface List
Figure 168. Editing a Line Interface to Create a New Service
– Enter a name for the new line
– Select an available local index, from the drop-down box
– Select appropriate framing and loopback modes
Configuring an M2PA System 121

Figure 169. Create New Line Service
Figure 170. Line Services List
Configuring an M2PA System 122

Understanding Parameters for Line Services
Table 30. Configuration Parameters for New Line Services
Name Used by the Web Portal to indicate a specific object or string in the system
Local Index Assigns an integer to represent an object
Framing Sets a framing type for a line service. Select from: AUTO (typical for E1)/STD/MFRAME/SF/ESF (typical for T1)/SLC96
Loopback Used to set a loopback state for a line service. Refer to Table 31 for details.
Table 31. Loopback Types
Loopback Type Description Behavior Use
All traffic is received and sent on the line Always
LINE Analog Line Loopback
All received traffic is re-routed on the transmit line. The clock and data recovered from the line inputs are routed back to the line outputs of the analog transceiver bypassing the framer modules.
First step in testing a physical connection
PAYLOAD Digital Line Loopback
All received traffic is re-routed on the transmit line.The clock and data recovered from the line inputs are routed back to the line outputs after the deframer/framer.
Second step in testing a physical connection. This tests the framer configuration.
This forces the transmit line to stop sending. This is the second-best thing to disconnecting the line interface physi cally.
LOCAL Local Loopback All received traffic is dropped. The traffic sent
Never. Used for inter nal testing only
is re-routed internally.
Configuring an M2PA System 123
NONE Normal Operation · GENERATE_LOS Generate Loss · of Signal

Creating the SCTP Configuration Stream Control Transmission Protocol (SCTP), a Transport Layer protocol, ensures reliable, in-sequence transport of messages. To edit your system's SCTP configuration:
Figure 171. Signaling > SCTP
– Make sure the box labeled Enabled is checked
– Enter a name for the SCTP service
– Select an appropriate service type: RAW_IP or UDP
Figure 172. Creating a New MTP2 Link
Figure 173. Successful SCTP Configuration Message
Understanding Parameters for SCTP Configurations
Table 32. Configuration Parameters for New SCTP Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Service Type Defines the purpose of an SCTP configuration. Possible values:
RAW IP: Enables the direct transmission and reception of network packets by applications, bypassing all encapsulation in the networking software of the operating system.
UDP: Provides a direct way to send and receive datagrams over IP networks.
Configuring an M2PA System 124

Creating an M2PA Configuration For the configuration of your SIGTRAN M2PA system, you will need to create a new M2PA configuration. In this system, the SS7 MTP2 layer is replaced by the SIGTRAN M2PA layer which extends MTP2 signaling functionality into the IP network.
To create an M2PA configuration:
Figure 174. Signaling > M2PA
– Verify that the Enabled box is checked
– Enter a name for the M2PA configuration
Figure 175. Creating the New M2PA Configuration
Figure 176. Successful M2PA Configuration Message
Understanding Parameters for M2PA Configurations
Table 33. Configuration Parameters for New M2PA Configurations
Enabled Indicates whether or not an object is to be implemented or not
Name Used by the Web Portal to indicate a specific object or string in the system
Configuring an M2PA System 125

Creating an M2PA SAP After you have created an M2PA configuration, you must create a new M2PA service access point (SAP) for your system. The SAP is an identifying label for endpoints in your network.
To create a new M2PA SAP:
Figure 177. M2PA SAPs
– Enter a name for the SAP
– Enter an SCTP source port for the SAP
Figure 178. Creating the New M2PA SAP
Figure 179. Successful M2PA Configuration Message
– Select an IP interface from the list in the information panel
– Click the "<<" button to add the selected IP interface. This is the outgoing route from the hardware
adapter.
Figure 180. Associating IP Interfaces
Configuring an M2PA System 126

Understanding Parameters for M2PA SAPs
Table 34. Configuration Parameters for New M2PA SAP
Name Used by the Web Portal to indicate a specific object or string in the system
SCTP Source Port Defines a source port for a service access point (SAP) in a system using SIGTRAN protocols
Creating M2PA Links After you have created an M2PA service access point (SAP), you must create a new M2PA link. This can be done from the M2PA SAP configuration window.
To create an M2PA link:
Figure 181. M2PA Links
– Enter a name for the new link
– Set other features, as needed: Number of SCTP Streams / IP Header TOS / Destination port (same
value as the one configured on the destination side)
Figure 182. Creating a New M2PA Link
Configuring an M2PA System 127

– Click the "<<" button to add the destination address to the address list
Figure 183. Designating a Destination Address
Figure 184. Successful M2PA Link Message
Understanding Parameters for M2PA Links
Table 35. Configuration Parameters for New M2PA Links
Name Used by the Web Portal to indicate a specific object or string in the system
Protocol Type Identifies the SS7 protocol variant that will be used with a particular object. The appropriate protocol variant depends on the user's geographical loca tion. Values are chosen from a drop-down list. The Protocol Type parameter can take on the following values, depending on the object being config ured:
TELCORDIA ANSI88 ANSI92 ANSI95
SINGAPORE Q767 TTC NTT
CHINA ETSI ETSIV3 UK
Number of SCTP Streams Sets the number of streams on a link in a system using the SCTP protocol
IP Header TOS Assigns a Type of Service (TOS) value to a line
Destination Port Sets a destination for a line in a system using SIGTRAN protocols
Configuring an M2PA System 128

Creating SS7 Point Codes Point codes are used to define the Smart Media system network, the adjacent network and the target network so that calls are properly routed from one network to the next.
To create SS7 originating (OPC) and destination (DPC) point codes:
Figure 185. SS7 > Point Codes
Figure 186. Point Codes
– Enter a name for the point code
– Select a point code type (select type-specific parameters)
– Select a point code length (14, 16, 24 bits)
– Enter a point code
Figure 187. Creating the New MTP3 Point Code
Configuring an M2PA System 129

Figure 188. Successful Point Code Message
Understanding Parameters for SS7 Point Codes
Table 36. Configuration Parameters for New Point Codes
Name Used by the Web Portal to indicate a specific object or string in the system
Type Defines the type of point code being created. Possible values: OPC/DPC/Mask
DPC Length Sets a format for the Destination Point Code (DPC) used by an object. Possible values: 14bits format=3.8.3/16bits format=7.4.5/24bits format=8.8.8
Point Code Defines a point code by assigning it numerical values.
Configuring an M2PA System 130

Creating an MTP3 Configuration MTP3 provides message routing between signaling points in an SS7 network.
To create an MTP3 configuration:
Figure 189. SS7 > MTP3
– Enter a name for the MTP3 configuration
– Make sure the Enabled and SSf Validation boxes are checked
– Select SP as the signaling point type
– Select a restart procedure
Figure 190. Creating the New MTP3 Configuration
Figure 191. Successful Configuration Message
Configuring an M2PA System 131

Understanding Parameters for MTP3 Configurations
Table 37. Configuration Parameters for New MTP3 Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Enabled Indicates whether or not an object is to be implemented or not
Ssf Validation Allows the activation of sub-service field validation for an MTP3 configuration
Signaling Point Type Indicates the intended purpose of an SS7 MTP3 layer object. Possible values: SP (Signaling Point)/STP (Signal Transfer Point)
Restart Procedure Indicates the standard by which a configuration will carry out a restart process. Possible values: None/ITU88/ITU92/ANSI
Creating an MTP3 Network After you have created your system's MTP3 configuration, you must create a new MTP3 network. An MTP3 network is created to define its point codes, link sets and routes. This can be done from the MTP3 configura tion information panel.
To create an MTP3 network:
Figure 192. MTP3 Networks in MTP3 Configuration Window
– Enter a name for the network
– Select a sub service field
– Select a link type
– Select the SS7 DPC length
Figure 193. Creating a New MTP3 Network
Figure 194. Successful Network Message
Configuring an M2PA System 132

Understanding Parameters for MTP3 Networks
Table 38. Configuration Parameters for New MTP3 Networks
Name Used by the Web Portal to indicate a specific object or string in the system
Sub Service Field Differentiates between national and international signals in MTP3 networks. Possible values: International/National/Nat. Reserved/Inter. Reserved
Link Type Sets a protocol type for signaling links. Possible values: ANSI/ITU/CHINA/ANSI96
SS7 DPC Length Sets a format for the Destination Point Code (DPC) used by an object. Possible values: 14bits format=3.8.3/16bits format=7.4.5/24bits format=8.8.8
Creating an MTP3 Linkset After you have created an MTP3 network, you are ready to create an MTP3 linkset. This can be done through the MTP3 network configuration window. A linkset is used to logically combine multiple MTP3 links going to the same DPC into a single entity. One linkset could be the links between a point code identifying the Smart Media SS7 node and a point code identifying the adjacent SS7 equipment.
To create an MTP3 linkset:
Figure 195. MTP3 Linksets
– Enter a name for the linkset
– Select an origin point code (OPC)
– Select an adjacent point code
– Make sure the desired state is set to Active
Configuring an M2PA System 133

Figure 196. Creating the New MTP3 Linkset
Figure 197. Successful Linkset Message
Understanding Parameters for MTP3 Linksets
Table 39. Configuration Parameters for New MTP3 Linksets
Name Used by the Web Portal to indicate a specific object or string in the system
Origin Point Code Associates an object with an originating point code (OPC)
Adjacent Point Code Associates an object with an adjacent point code
Desired State Indicates whether an object is to be active or inactive upon creation Possible values: Active/Inactive
Creating MTP3 Links (M2PA) This can be done from the MTP3 linkset configuration window. A linkset is used to logically combine multi ple MTP3 links going to the same DPC into a single entity. One linkset could be comprised of the links between a point code identifying the Smart Media SS7 node and a point code identifying the adjacent SS7 equipment.
To create an MTP3 link:
Figure 198. M2PA Links
– Enter a name for the link
Configuring an M2PA System 134

– Under Type of link to bind, select M2PA
– Select an MTP2 link
– Select a priority level (from 0 to 3)
– Select a message priority (from "none" to 3)
– Set the C Link value
– Enter a Link Test Slc (this value is unique in the link list)
– Enter Link Test Characters
Figure 199. Creating the New MTP3 (M2PA) Link
Figure 200. Successful MTP3 Link Message
Configuring an M2PA System 135

Understanding Parameters for MTP3 (M2PA) Links
Table 40. Configuration Parameters for New MTP3 (M2PA) Links
Name Used by the Web Portal to indicate a specific object or string in the system
Type of Link to Bind Indicates the type of link to bind when creating an MTP3 link Possible values: MTP2/M2PA/M2UA
MTP2 Link Selects an MTP2 link to bind to an object
Priority Level Sets a priority for MTP3 links. Possible values: Priority 0/Priority 1/Priority 2/Priority 3
Message Priority Sets a priority for messages on an MTP3 link. Possible values: None/Priority 0/Priority 1/Priority 2/Priority 3
C Link Used only when two identical signal transfer points (STPs) are interconnected
Link Test Slc Used in SLTM/SLTA messages on MTP3 links. Possible values: 0-15 *NOTE: Both ends of the line must use the same value, or the line will fail.
Link Test Characters Creates a test packet for MTP3 lines
Creating an MTP3 Route MTP3 routes are built to route traffic from previously created point codes using linksets. One route is created for each previously defined point code.
To create an MTP3 route:
Figure 201. MTP3 Routes
– Enter a name for the route
– Select a point code for the route
– Select a restart procedure
– Select a point type
– Check the Route to Adjacent box, if this route is directed to an adjacent network
Configuring an M2PA System 136

Figure 202. Creating the New MTP3 Route
Figure 203. Successful MTP3 Route Message
– Select a linkset from the list provided at the bottom of the route configuration window
– Click the "<<" button to associate the linkset with the newly created route
Figure 204. Associating Routes with Linksets
Configuring an M2PA System 137
– Create

Understanding Parameters for MTP3 Routes
Table 41. Configuration Parameters for New MTP3 Routes
Name Used by the Web Portal to indicate a specific object or string in the system
Point Code Associates a point code with the MTP3 route
Restart Procedure Indicates the standard by which a configuration will carry out a restart process. Possible values: None/ITU88/ITU92/ANSI
Point Type Indicates the intended purpose of an SS7 MTP3 layer object. Possible values: SP (signaling Point)/STP (Signal Transfer Point)
Route to Adjacent Used when an MTP3 route is directed toward an adjacent network
Creating an ISUP Stack After you have configured the MTP3 layer of your SS7 system, you must create an ISDN user part stack. To create an ISUP stack:
Figure 205. SS7 > ISUP
Figure 206. ISUP Stack List
– Make sure the box labeled Enabled is checked
– Enter a name for the stack
– Select a primary hardware adapter
– Select a secondary hardware adapter
Configuring an M2PA System 138

Figure 207. Creating the New ISUP Stack
Figure 208. Successful ISUP Stack Message
Understanding Parameters for ISUP Stacks
Table 42. Configuration Parameters for New ISUP Stack
Name Used by the Web Portal to indicate a specific object or string in the sys tem
Primary Hardware Adapter Identifies a main Smart Media hardware device to run an ISUP stack
Secondary Hardware Adapter Identifies a secondary (backup) Smart Media hardware device to run
Creating an ISUP Network After you have created an initial ISUP stack, you must create a new ISUP network. The ISUP network tells the ISUP protocol layer about a collection of SS7 nodes that are accessible through MTP3 or M3UA. Based upon your system configuration, one or more ISUP networks are created. Repeat this section for as many networks as you require.
To create an ISUP network:
Figure 209. Editing ISUP Networks
Configuring an M2PA System 139
an ISUP stack

– Enter a name for the network
– Select MTP3 or M3UA as the type of network to bind
– Select a MTP3 network or a M3UA network
Figure 210. Creating the New ISUP Network
Figure 211. Successful ISUP Network Message
Understanding Parameters for ISUP Networks
Table 43. Configuration Parameters for New ISUP Network
Name Used by the Web Portal to indicate a specific object or string in the system
Type of Network to Bind Indicates the type of network to associate with an ISUP Network Possible values: MTP3/M3UA
MTP3 Network Associates an MTP3 network with a higher level network in an SS7 system
M3UA Network Associates an MTP3 network with a higher level network in an SS7 system
Configuring an M2PA System 140
Networks

Creating an ISUP User Part After you have created your ISUP network, you must create a new ISUP user part. The user part is the con tainer for the multiple ISUP interfaces. One user part is required for each protocol variant.
Multiple ISUP user parts can be instantiated within a single ISUP protocol layer. This allows a user application to interface with multiple SS7 ISUP protocol variants at the same time. Only one ISUP user part is required for a specific variant as it can be assigned to multiple ISUP networks.
A user part can easily be seen as a protocol variant that a host application wants to use on the SS7 network.
To create an ISUP user part:
Figure 212. Editing Userparts
– Enter a name for the user part
– Select a protocol variant (depending on location)
– Select an MTP3 sub service field (the same that was previously set for MTP3)
– Select an address indicator type
– Select a Numbering Plan
Figure 213. Creating the New ISUP User Part
Figure 214. Successful ISUP User Part Message
Configuring an M2PA System 141

Understanding Parameters for ISUP User Parts
Table 44. Configuration Parameters for New ISUP User Part
Name Used by the Web Portal to indicate a specific object or string in the system
Protocol Type Identifies the SS7 protocol variant that will be used with a particular object. The appropriate protocol variant depends on the user's geographical location. Values are chosen from a drop-down list. The Protocol Type parameter can take on the following values, depending on the object being configured:
TELCORDIA ANSI88 ANSI92 ANSI95
SINGAPORE Q767 TTC NTT
CHINA ETSI ETSIV3 UK
Sub Service Field Differentiates between national and international signals in MTP3 networks. Possible values: International/National/Nat. Reserved/Inter. Reserved
Address Indicator Type Assigns a default address value in ISUP user parts, when unspecified.
Numbering Plan Assigns a default numbering plan in ISUP user parts, when unspecified. Possible values:
Creating an ISUP Interface After you have created an ISUP user part to contain them, you must create new ISUP interfaces.
The ISUP interface creates a binding within the ISUP layer of a particular variant, a specific network, and an OPC/DPC pair to which circuits can be assigned. The ISUP interface contains the circuit identifier codes (CICs) within the ISUP user part. One interface is created for each similar grouping of CICs within one user part protocol variant.
To create an ISUP interface:
Figure 215. Editing ISUP Interfaces
Configuring an M2PA System 142

– Enter a name for the interface
– Select an ISUP user part
– Select an ISUP network
– Select a trunk type
– Select an originating point code (OPC)
– Select a destination point code (DPC)
Figure 216. Creating the New ISUP Interface
Figure 217. Successful ISUP Interface Message
Understanding Parameters for ISUP Interfaces
Table 45. Configuration Parameters for New ISUP Interface
Name Used by the Web Portal to indicate a specific object or string in the system
ISUP User Part Associates an ISUP user part with an ISUP interface
ISUP Network Associates an ISUP network with an ISUP interface
OPC Associates an object with an originating point code (OPC)
DPC Associates an object with a destination point code (DPC)
Configuring an M2PA System 143

Creating ISUP CIC Groups After you have created an ISUP interface, you must create a new ISUP Cicuit Identification Code (CIC) group for your system.A CIC represents a physical timeslot between two SS7 nodes. Both of those nodes must com monly agree upon a CIC numbering scheme.
To create an ISUP CIC group:
Figure 218. Editing CIC Groups
– Enter a name for the group
– Enter a number for the first CIC in the group (this value must follow other CIC group values, and not
– Select a line service
– Check the appropriate timeslots (click "Select all" to check all timeslots)
– Select a call control method
Figure 219. Creating the New ISUP CIC Group
Figure 220. Successful ISUP CIC Group Message
Configuring an M2PA System 144
overlap)

Understanding Parameters for ISUP CIC Groups
Table 46. Configuration Parameters for New ISUP CIC Group
Name Used by the Web Portal to indicate a specific object or string in the system
First CIC Sets a value for the first circuit identification code in an ISUP CIC group
Line Service Indicates which TDM line service is to be associated with the object being cre ated
Timeslots Allows the selection of individual voice or data channels of a line. Values for this parameter are listed as check boxes (ranging from 1-24). Individual timeslots can be selected by checking the boxes. Occasionally, all timeslots can be selected at once by clicking the Select All link.
Call Control Sets a call control method for ISUP CIC groups. Possible values: Incoming/Outgoing/Bothway/Controlled/Controlling
Creating a NAP (SIGTRAN) After you have created an ISUP CIC group, you must create a network access point, in order to finish config uring your system. A Network Access Point (NAP) represents the entry point to another network or destina tion peer.
To create a network access point (NAP):
Figure 222. Edit NAP List
– Enter a name for the NAP
– Select a user-created profile, if not, select default
Configuring an M2PA System 145

Figure 223. Creating a New NAP (SIGTRAN)
Figure 224. Confirmation Message for New NAP
– Select an interface (the newly-created ISUP CIC group)
– Click the "<<" button to associate it with the NAP
Figure 225. Associating ISUP CIC Groups with NAPs
The following screen displays:
Figure 226. Saving the New NAP SS7 Parameters
– Select a value for Channel Usage to avoid call collision.
Configuring an M2PA System 146
– Click Save

Figure 227. Confirmation Message for Updated NAP
Understanding Parameters for NAPs (SIGTRAN)
Table 47. Configuration Parameters for NAPs (SIGTRAN)
Name Used by the Web Portal to indicate a specific object or string in the system
Default Profile Sets a profile for a NAP. The default value is simply labeled "Default", but can be changed if alternate profiles have been created.
Channel Usage Sets a channel usage scheme for Network Access Points (NAPs), also called trunk
groups, in order to avoid call collision. Possible values:
Round-Robin: Traverse, in order, all timeslots of the NAP from first timeslot of first trunk to last timeslot of last trunk, before starting to use first timeslot of first trunk again.
Lowest Timeslot: Start from lowest timeslot of every trunk and will reuse them if they are idle.
Highest Timeslot: Start from highest timeslot of every trunk and will reuse them if they are idle.
Lowest Mapping ID: Start from lowest timeslot of first trunk, second lowest of first trunk, etc. Once the first trunk is full, will start using second trunk. Will reuse the channels if they are idle.
trunk, etc. Once the last trunk is full, will start using second-to- last trun. Will reuse the channels if they are idle.
Lowest CIC: Start from lowest CIC value of the NAP and will reuse them if they are idle.
Highest CIC: Start from highest CIC value of the NAP and will reuse them if they are idle.
Odd Lowest CIC: Start from lowest CIC, odd value, and will reuse them if they are idle. Will only use even CICs when all odd CICs are used.
Odd Highest CIC: Start from highest CIC, odd value, and will reuse them if they are idle. Will only use even CICs when all odd CICs are used.
Even Lowest CIC: Start from lowest CIC, even value, and will reuse them if they are idle. Will only use even CICs when all even CICs are used.
Even Highest CIC: Start from highest CIC, even value, and will reuse them if they are idle. Will only use even CICs when all odd CICs are used.
Configuring an M2PA System 147

In this configuration, M2UA bridges the SS7 MTP2 layer of a Signaling Gateway across an IP network . Refer to the following sections to configure an M2UA system:
– “Creating MTP2 Links” on page 149
– “Creating an M2UA SAP” on page 152
– “Creating an M2UA Cluster” on page 153
– “Creating M2UA Links” on page 154
– “Creating M2UA Peers” on page 156
Creating an MTP2 Configuration 1. Select MTP2 from the navigation panel:
Figure 228. Signaling > MTP2
– Enter a name for the configuration
Figure 229. Creating the New MTP2 Configuration
Configuring an M2UA System on a Signaling Gateway 148
– Click Save

Figure 230. Successful Configuration Message
Understanding Parameters for MTP2 Configurations
Table 48. Configuration Parameters for New MTP2 Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Creating MTP2 Links Now that you have created an MTP2 configuration, you must create the necessary MTP2 links. An MTP2 link is used to connect the MTP2 physical layer to a line service carrying SS7 signaling.
To create an MTP2 link:
Figure 231. MTP2 Link in MTP2 Configuration Window
– Enter a name for the new link
– Select a connection mode
– Select a line service
– Assign timeslots to the link
– Select a protocol type
– Select a DPC length
– Select a timeslot rate
Configuring an M2UA System on a Signaling Gateway 149

Figure 232. Creating a New MTP2 Link
Figure 233. Successful Link Message
Configuring an M2UA System on a Signaling Gateway 150

Understanding Parameters for MTP2 Links
Table 49. Configuration Parameters for New MTP2 Links
Name Used by the Web Portal to indicate a specific object or string in the system
Connection Mode Defines the type of connection used in an SS7 system. Possible values: Normal/Hsl (High-speed link)
Line Service Indicates which TDM line service is to be associated with the object being created
Timeslots Allows the selection of individual voice or data channels of a line. Values for this parameter are listed as check boxes (ranging from 1-24). Individual timeslots can be selected by checking the boxes. Occasionally, all timeslots can be selected at once by clicking the Select All link.
Protocol Type Identifies the SS7 protocol variant that will be used with a particular object. The appropriate protocol variant depends on the user's geographical location. Values are chosen from a drop-down list. The Protocol Type parameter can take on the following values, depending on the object being configured:
TELCORDIA ANSI88 ANSI92 ANSI95
SINGAPORE Q767 TTC NTT
CHINA ETSI ETSIV3 UK
DPC Length Sets a format for the Destination Point Code (DPC) used by an object. Possible values: 14bits format=3.8.3/16bits format=7.4.5/24bits format=8.8.8
Timeslot Rate Indicates the data rate for timeslots on a line. Possible values: 64 Kbps/56 Kbps/48 Kbps
Creating an M2UA Configuration To create your M2UA system, you must create a new M2UA configuration.
M2UA (Message Transfer Part 2 User Adaptation Layer) is used to interface the MTP2 Layer of a signaling gateway to the MTP3 Layer of a media gateway controller (MGC). M2UA can also be seen as a way to extend an MTP2 link. An M2UA link is always bound to an MTP2 link.
To create an M2UA configuration:
Figure 234. Signaling > M2UA
– Enter a name for the M2UA service
Configuring an M2UA System on a Signaling Gateway 151

Figure 235. Creating the New M2UA Configuration
Figure 236. Successful M2UA Configuration Message
Understanding Parameters for M2UA Configurations
Table 50. Configuration Parameters for New M2UA Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Creating an M2UA SAP After you have created an M2UA configuration, you must create a new M2UA service access point (SAP) for your system. The SAP is an identifying label for endpoints in your network.
To create an M2UA SAP:
Figure 237. M2UA SAPs
– Enter a name for the SAP
– Enter an SCTP source port for the SAP
Configuring an M2UA System on a Signaling Gateway 152

Figure 238. Creating the New M2UA SAP
Figure 239. Successful M2UA Configuration Message
– Select an IP interface from the Edit IP Interfaces list
– Associate the interface with the SAP, using the "<<" button.
Figure 240. Associating IP Interfaces
Understanding Parameters for M2UA SAPs
Table 51. Configuration Parameters for New M2UA SAP
Name Used by the Web Portal to indicate a specific object or string in the system
SCTP Source Port Defines a source port for a service access point (SAP) in a system using SIGTRAN protocols
Creating an M2UA Cluster After you have created an M2UA SAP, you must create an M2UA cluster for your system.
To create an M2UA cluster:
Figure 241. M2UA Clusters
Configuring an M2UA System on a Signaling Gateway 153

– Enter a name for the cluster
– Select a traffic mode
– Select a load share mode
Figure 242. Creating the New M2UA Cluster
Figure 243. Successful M2UA Cluster Message
Understanding Parameters for M2UA Clusters
Table 52. Configuration Parameters for New M2UA Cluster
Name Used by the Web Portal to indicate a specific object or string in the system
Traffic Mode Sets the scheme for managing traffic on an M2UA cluster. Possible values: ACTIVE_STANDBY/LOADSHARE
Load Share Mode Sets a scheme for sharing traffic loads on M2UA clusters. Possible values: ROUND_ROBIN/PER_LINK
Creating M2UA Links After you have created an M2UA cluster, you must create M2UA links for your system. An M2UA link is always bound to an MTP2 link, and can be seen a way of extending MTP2 functionality.
To create an M2UA link:
Figure 244. M2UA Links
– Enter a name for the link
Configuring an M2UA System on a Signaling Gateway 154

–For a system on a signaling gateway: Select an MTP2 link
–For a system on a media gateway controller: Select NONE
– Select a protocol type (same as MTP2)
– Select an interface ID type
– Enter an appropriate interface ID (must be unique to each link)
Figure 245. Creating a New M2UA Link
Figure 246. Successful M2UA Link Message
Understanding Parameters for M2UA Links
Table 53. Configuration Parameters for New M2UA Links
Name Used by the Web Portal to indicate a specific object or string in the system
MTP2 Link Selects an MTP2 link to bind to an object
Protocol Type Identifies the SS7 protocol variant that will be used with a particular object. The appropriate protocol variant depends on the user's geographical loca tion. Values are chosen from a drop-down list. The Protocol Type parameter can take on the following values, depending on the object being config ured:
TELCORDIA ANSI88 ANSI92 ANSI95
SINGAPORE Q767 TTC NTT
CHINA ETSI ETSIV3 UK
Interface ID Type Defines the data type of an M2UA Link's interface ID. Possible values: Integer/String
Interface ID Identifies the interface of an M2UA link
Configuring an M2UA System on a Signaling Gateway 155

Creating M2UA Peers After you have created the M2UA links, you must define M2UA peers for your system.
To create an M2UA peer:
Figure 247. M2UA Peers
– Enter a name for the peer
– Enter a destination port (as configured in the destination element)
Figure 248. Creating the New M2UA Peer
Figure 249. Successful M2UA Peer Message
– Enter a destination address
– Click the "<<" button to add it to the list of destination addresses
– Verify that the “(your address) was successfully added” message displays
Figure 250. Editing Destination Addresses
Configuring an M2UA System on a Signaling Gateway 156

Understanding Parameters for M2UA Peers
Table 54. Configuration Parameters for New M2UA Peers
Name Used by the Web Portal to indicate a specific object or string in the system
Destination Port Sets a destination for a line in a system using SIGTRAN protocols
Destination Address Indicates the destination for a line in a system using SIGTRAN protocols
Configuring an M2UA System on a Signaling Gateway 157


Creating MTP3 Links (M2UA) After you have created an MTP3 linkset, you must create MTP3 links for your system. An MTP3 link is used to connect with a M2UA link; they are connected in a one-to-one fashion.
To create an MTP3 link on your M2UA system:
Figure 251. MTP3 Links
– Enter a name for the link
– Under Type of link to bind, select M2UA
– Select an M2UA link
Figure 252. Creating the New MTP3 (M2UA) Link
Figure 253. Successful MTP3 Link Message
Understanding Parameters for MTP3 (M2UA) Links
Table 55. Configuration Parameters for New MTP3 (M2UA) Links
Name Used by the Web Portal to indicate a specific object or string in the system
Type of Link to Bind Indicates the type of link to bind when creating an MTP3 link Possible values: MTP2/M2PA/M2UA
M2UA Link Selects an M2UA link to bind to an object
Configuring an M2UA System on a Media Gateway Controller 159

In this configuration, IUA bridges the SS7 MTP2 layer of a Signaling Gateway across an IP network with the SS7 MTP3 layer of a Media Gateway Controller. Refer to the following sections to configure an IA system:
– “Creating an IUA SAP” on page 161
– “Creating an IUA Cluster” on page 162
– “Creating IUA Links” on page 163
– “Creating IUA Peers” on page 164
Creating an IUA Configuration An IUA system on a Signaling Gateway Controller interfaces with an IUA system on a Media Gateway Con troller. To create your IUA system, you must create a new IUA configuration.
To create an IUA configuration:
Figure 254. Signaling > IUA
– Enter a name for the IUA service
Figure 255. Creating the New IUA Configuration
Configuring an IUA System on a Signaling Gateway 160
– Click Save

Understanding Parameters for IUA Configurations
Table 56. Configuration Parameters for New IUA Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Creating an IUA SAP After you have created an IUA configuration, you must create a new IUA service access point (SAP) for your system. The SAP is an identifying label for endpoints in your network.
To create an IUA SAP:
Figure 256. IUA SAPs
– Enter a name for the SAP
– Enter a number for the SCTP source port
Figure 257. Creating the New IUA SAP
Figure 258. Successful IUA Configuration Message
– Select an IP interface from the Edit IP Interfaces list
– Associate the interface with the SAP, using the "<<" button.
Figure 259. Associating IP Interfaces with the IUA SAP
Configuring an IUA System on a Signaling Gateway 161

Understanding Parameters for IUA SAPs
Table 57. Configuration Parameters for New IUA SAP
Name Used by the Web Portal to indicate a specific object or string in the system
SCTP Source Port Defines a source port for a service access point (SAP) in a system using SIGTRAN protocols
Creating an IUA Cluster After you have created an IUA SAP, you must create an IUA cluster for your system.
To create an IUA cluster:
Figure 260. IUA Clusters
– Enter a name for the cluster
– Select a traffic mode
– Select a load share mode
Figure 261. Creating the New IUA Cluster
Figure 262. Successful IUA Cluster Message
Configuring an IUA System on a Signaling Gateway 162

Understanding Parameters for IUA Clusters
Table 58. Configuration Parameters for New IUA Cluster
Name Used by the Web Portal to indicate a specific object or string in the system
Traffic Mode Sets the scheme for managing traffic on an IUA cluster. Possible values: ACTIVE_STANDBY/LOADSHARE
Load Share Mode Sets a scheme for sharing traffic loads on IUA clusters. Possible values: ROUND_ROBIN/PER_LINK
Creating IUA Links After you have created an IUA cluster, you must create IUA links for your system. To create an IUA link:
Figure 263. IUA Links
– Enter a name for the link
– Enter an appropriate interface ID (must be unique to each link)
– Select a line service
– Select a variant
– Select a side
Figure 264. Creating a New IUA Link
Figure 265. Successful IUA Link Message
Configuring an IUA System on a Signaling Gateway 163

Understanding Parameters for IUA Links
Table 59. Configuration Parameters for New IUA Links
Name Used by the Web Portal to indicate a specific object or string in the system
Interface ID Identifies the interface of an IUA link
Variant Indicates the protocol variant to be used on a signaling stack. Possible values:
AUS HONG-KONG
5ESS JAPAN INS
DMS
Side Defines each side of an ISDN stack. Possible values: Network/User
Creating IUA Peers After you have created the IUA links, you must define IUA peers for your system.To create an IUA peer:
Figure 266. IUA Peers
– Enter a name for the peer
– Enter a destination port (as configured in the destination element)
Figure 267. Creating the New IUA Peer
Figure 268. Successful IUA Peer Message
– Enter a destination address
– Click the "<<" button to add it to the list of destination addresses
Configuring an IUA System on a Signaling Gateway 164

– Verify that the “(your address) was successfully added” message displays
Figure 269. Editing Destination Addresses
Understanding Parameters for IUA Peers
Table 60. Configuration Parameters for New IUA Peers
Name Used by the Web Portal to indicate a specific object or string in the system
Destination Port Sets a destination for a line in a system using SIGTRAN protocols
Destination Address Indicates the destination for a line in a system using SIGTRAN protocols
Configuring an IUA System on a Signaling Gateway 165


Creating an M3UA Configuration (IPSP) To set up your M3UA system on an IP server process (IPSP), you must first create a new M3UA configuration. In this configuration the SS7 MTP2 and MTP3 layers are replaced entirely by the SIGTRAN M3UA layer. This system is typically set up on two IP signaling points. To create an M3UA configuration on IPSP:
Figure 270. SS7 > M3UA
– Enter a name for the configuration
– Select IP Server Process (IPSP) as the node type
Figure 271. Creating the New M3UA Configuration
Figure 272. Successful Configuration Message
Understanding Parameters for M3UA Configurations
Table 61. Configuration Parameters for New M3UA Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Node Type Assigns a configuration to an M3UA network. Possible values: Signaling Gateway Process (SGP) Application Server Process (ASP) IP Server Process (IPSP)
Configuring an M3UA System on IP Signaling Points 167

Creating an M3UA SAP After you have created an M3UA configuration, you must create a new M3UA service access point (SAP) for your system. The SAP is an identifying label for endpoints in your network. To create an M3UA SAP:
Figure 273. M3UA SAPs
– Enter a name for the SAP
– Select an SCTP adapter to use
– Select an SCTP source port
Figure 274. Creating a New M3UA SAP
Figure 275. Successful Link Message
– Select an IP interface from the Edit IP Interfaces list
– Associate the interface with the SAP, using the "<<" button.
Figure 276. Associating IP Interfaces with the M3UA SAP
Configuring an M3UA System on IP Signaling Points 168

Understanding Parameters for M3UA SAPs
Table 62. Configuration Parameters for New M3UA SAPs
Name Used by the Web Portal to indicate a specific object or string in the system
SCTP Adapter Defines a virtual adapter for a service access point (SAP) in a system using SIGTRAN protocols
SCTP Source Port Defines a source port for a service access point (SAP) in a system using SIGTRAN protocols
Creating an M3UA Network After you have created M3UA SAPs, you must create a new M3UA network to be used with them. To create an M3UA network:
Figure 277. M3UA Networks List
– Enter a name for the network
– Select a protocol type
– Select a sub-service field
– Select a Destination Point Code (DPC )length
– Select an Signaling Link Selection (SLS) range
Figure 278. Creating the New M3UA Network
Figure 279. Successful M3UA Network Message
Configuring an M3UA System on IP Signaling Points 169

Understanding Parameters for M3UA Networks
Table 63. Configuration Parameters for New M3UA Networks
Name Used by the Web Portal to indicate a specific object or string in the system
Protocol Type Identifies the SS7 protocol variant that will be used with a particular object. The appropriate protocol variant depends on the user's geographical location. Values are chosen from a drop-down list. The Protocol Type parameter can take on the following values, depending on the object being configured:
TELCORDIA ANSI88 ANSI92 ANSI95
SINGAPORE Q767 TTC NTT
CHINA ETSI ETSIV3 UK
Sub Service Field Differentiates between national and international signals in MTP3 networks. Possible values: International/National/Nat. Reserved/Inter. Reserved
DPC Length Sets a format for the destination point code (DPC) used by an object. Possible values: 14bits format=3.8.3 / 16bits format=7.4.5 / 24bits format=8.8.8
SLS Range Used to route MPT3 links in the SS7 network
Creating an M3UA User Part After you have created an M3UA network, you must create a new M3UA user part. To create an M3UA user part:
Figure 280. M3UA Network Configuration Window: Create M3UA User Part
– Enter a name for the user part
–For a system set up on a Signaling Gateway: Select an MTP3 network
–For a system set up on IPSP or ASP, the MTP3 network field is not visible.
Figure 281. Creating the New M3UA User Part
Configuring an M3UA System on IP Signaling Points 170

Figure 282. Successful M3UA User Part Message
Understanding Parameters for M3UA User Parts
Table 64. Configuration Parameters for New M3UA User Part
Name Used by the Web Portal to indicate a specific object or string in the system
MTP3 Network (Only displays for Signaling Gateway) Associates an MTP3 network with a higher level network in an SS7 system
Creating an M3UA Peer Signaling Process (IPSP) After you have created M3UA user part, you must create a new M3UA peer signaling process (PSP). A PSP is used to describe a remote IPSP that is accessible through the M3UA system.
To create an M3UA Peer Signalling Process (PSP) on IPSP:
Figure 283. M3UA Network Configuration Window: Create M3UA PSP
– Enter a name for the PSP
– Select IP Server Process (IPSP) as the PSP type
– Enter a destination port (as configured in the destination element)
Figure 284. Creating the New M3UA PSP
Configuring an M3UA System on IP Signaling Points 171

Figure 285. Successful M3UA PSP Message
– Select a SAP from the list of available SAPs
– Click the "<<" button to associate it with the PSP.
Figure 286. Associating SAPs with the M3UA PSP
– Enter a destination address
– Click the "<<" button to add the destination address to the PSP
– Verify that the "(your address) was successfully added" message appears.
Figure 287. Editing Destination Address for the PSP
Understanding Parameters for M3UA PSPs
Table 65. Configuration Parameters for New M3UA PSPs
Name Used by the Web Portal to indicate a specific object or string in the system
PSP Type Assigns a configuration to an M3UA peer signaling process. Possible values: Signaling Gateway Process (SGP) Application Server Process (ASP) IP Server Process (IPSP)
Destination Port Sets a destination for a line in a system using SIGTRAN protocols
Configuring an M3UA System on IP Signaling Points 172

Creating an M3UA Peer Server After you have created an M3UA peer signaling process (PSP), you must create a new Peer server. A peer server is a logical entity on the IP network that is served by one or more PSPs. To create an M3UA peer server:
Figure 288. M3UA Network Configuration Window: Create M3UA Peer Server
– Enter a name for the peer server
– Check the Local box for local peer server (OPC).
For remote peer server (DPC), do not check this box.
– Enter a value for the routing context (must be unique within a local or non-local server list. However,
this value does not need to be unique across lists).
Figure 289. Creating the New M3UA Peer Server
Figure 290. Successful M3UA Peer Server Message
– Select a PSP from the list of available PSPs
Configuring an M3UA System on IP Signaling Points 173

– Click the "<<" button to associate the PSP with the peer server.
Figure 291. Associating PSPs with the New Peer Server
Understanding Parameters for M3UA Peer Servers
Table 66. Configuration Parameters for New M3UA Peer Servers
Name Used by the Web Portal to indicate a specific object or string in the system
Local Defines an M3UA peer server as a local server
Routing Context Sets an integer value for an M3UA peer server, to identify information sent. Values for this parameter are entered into a field, and must be unique within a single server list.
Configuring an M3UA System on IP Signaling Points 174

Creating an M3UA Route After you have configured M3UA user parts, PSPs, and peer servers, you must create an M3UA route for your system. To create an M3UA route:
Figure 292. M3UA Network Configuration Window: Create M3UA Route
– Enter a name for the route
– Select a route type
– Select an M3UA peer server (choose Local Peer server, if associated with an OPC, select Remote Peer
server, if using DPC)
– Select an M3UA user part (select NONE, if associated with a DPC)
– Select a point code
– Select a point code mask (Recommended value: Exact-match)
– Select a sub-service field type
Figure 293. Creating the New M3UA Route
Figure 294. Successful M3UA Route Message
Configuring an M3UA System on IP Signaling Points 175

Understanding Parameters for M3UA Routes
Table 67. Configuration Parameters for New M3UA Routes
Name Used by the Web Portal to indicate a specific object or string in the system
Route Type Assigns a type to an M3UA Route. Possible values: Local / Psvr
M3UA Peer Server (Only available if Psrv was chosen as the route type) Associates a peer server with an M3UA route
M3UA User Part Associates a userpart with an M3UA route
Point Code Associates a point code with the M3UA route
Point Code Mask Sets a scheme for accepting point codes in an M3UA route. By default, the only available value is “Exact match”.
Sub-Service Field Type Sets a type for the sub-service field (SSF) of an M3UA route.
Configuring an M3UA System on IP Signaling Points 176

An M3UA system on a Signaling Gateway Process interfaces with an M3UA system on an Application Server Process. In this configuration, the MTP3 links are extended across the IP network. Refer to the following sec tions to configure an M3UA system:
– “Creating an MTP3 Network” on page 132
– “Creating an MTP3 Linkset” on page 133
– “Creating MTP3 Links (M3UA)” on page 178
– “Creating an MTP3 Route” on page 136
– “Creating an M3UA SAP” on page 168
– “Creating an M3UA Network” on page 169
– “Creating an M3UA User Part” on page 170
– “Creating an M3UA Peer Signaling Process (SGP)” on page 181
– “Creating an M3UA Peer Server” on page 173
– “Creating an M3UA Route (SGP)” on page 183
Configuring an M3UA System on a Signaling Gateway 177

Creating MTP3 Links (M3UA) After you have created an MTP3 linkset, you must create MTP3 links for your system. An MTP3 link is used to connect with a MTP2 link; they are connected in a one-to-one fashion.
To create an MTP3 link on your M3UA system:
Figure 295. MTP3 Links
– Enter a name for the link
– Select MTP2 as the type of link to bind
– Select an MTP2 link
– Select a priority level
– Select a Messages priority
– Set the C Link value
– Enter a Link Test Slc (this value is unique in the link list)
– Enter Link Test Characters
Figure 296. Creating the New MTP3 (M3UA) Link
Configuring an M3UA System on a Signaling Gateway 178

Figure 297. Successful MTP3 Link Message
Understanding Parameters for MTP3 (M3UA) Links
Table 68. Configuration Parameters for New MTP3 (M3UA) Links
Name Used by the Web Portal to indicate a specific object or string in the system
Type of Link to Bind Indicates the type of link to bind when creating an MTP3 link Possible values: MTP2/M2PA/M2UA
MTP2 Link Selects an MTP2 link to bind to an object
Priority Level Sets a priority for MTP3 links. Possible values: Priority 0/Priority 1/Priority 2/Priority 3
Message Priority Sets a priority for messages on an MTP3 link. Possible values: None/Priority 0/Priority 1/Priority 2/Priority 3
C Link Used only when two identical signal transfer points (STPs) are interconnected
Link Test Slc Used in SLTM/SLTA messages on MTP3 links. Possible values: 0-15 *NOTE: Both ends of the line must use the same value, or the line will fail.
Link Test Characters Creates a test packet for MTP3 lines
Configuring an M3UA System on a Signaling Gateway 179

Creating an M3UA Configuration (SGP) To set up your M3UA system on a signaling gateway process (SGP), you must first create a new M3UA config uration. In this configuration the SS7 MTP2 layer is replaced entirely by the SIGTRAN M3UA layer, and the MTP3 layer is extended over the IP network. To create an M3UA configuration on an SGP:
Figure 298. SS7 > M3UA
– Enter a name for the configuration
– Select Signaling Gateway Process (SGP) as the node type
Figure 299. Creating the New M3UA (SGP) Configuration
Figure 300. Successful Configuration Message
Understanding Parameters for M3UA Configurations
Table 69. Configuration Parameters for New M3UA Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Node Type Assigns a configuration to an M3UA network. Possible values: Signaling Gateway Process (SGP) Application Server Process (ASP) IP Server Process (IPSP)
Configuring an M3UA System on a Signaling Gateway 180

Creating an M3UA Peer Signaling Process (SGP) After you have created M3UA user part, you must create a new M3UA peer signaling process (PSP). A PSP is used to describe a remote ASP that is accessible through the M3UA system.
To create an M3UA Peer Signaling Process (PSP) on an SGP system:
Figure 301. M3UA Network Configuration Window: Create M3UA PSP
– Enter a name for the PSP
– Select Signaling Gateway Process (SGP) as the PSP type
– Enter a destination port (as configured in the destination element)
Figure 302. Creating the New M3UA PSP (ASP)
Figure 303. Successful M3UA PSP Message
– Select a SAP from the list of available SAPs
Configuring an M3UA System on a Signaling Gateway 181

– Click the "<<" button to associate it with the PSP.
Figure 304. Associating SAPs with the M3UA PSP
– Enter a destination address
– Click the "<<" button to add the destination address to the PSP
– Verify that the "(your address) was successfully added" message appears.
Figure 305. Editing Destination Address for the PSP
Understanding Parameters for M3UA PSPs
Table 70. Configuration Parameters for New M3UA PSPs
Name Used by the Web Portal to indicate a specific object or string in the system
PSP Type Assigns a configuration to an M3UA peer signaling process. Possible values: Signaling Gateway Process (SGP) Application Server Process (ASP) IP Server Process (IPSP)
Destination Port Sets a destination for a line in a system using SIGTRAN protocols
Configuring an M3UA System on a Signaling Gateway 182

Creating an M3UA Route (SGP) After you have configured M3UA user parts, PSPs, and peer servers, you must create an M3UA route for your system. To create an M3UA route on an SGP:
Figure 306. M3UA Network Configuration Window: Create M3UA Route
– Enter a name for the route
– Select a route type
– Select an M3UA peer server (choose Remote Peer server, if associated with an OPC, select NONE, if
– Select an M3UA user part (if associated with a DPC, select NONE for OPC)
– Select a point code
– Select a point code mask (Recommended value: Exact-match)
– Select a sub-service field type
Figure 307. Creating the New M3UA Route
Figure 308. Successful M3UA Route Message
Configuring an M3UA System on a Signaling Gateway 183
using DPC)

Understanding Parameters for M3UA Routes
Table 71. Configuration Parameters for New M3UA Routes
Name Used by the Web Portal to indicate a specific object or string in the system
Route Type Assigns a type to an M3UA Route. Possible values: Local / Psvr
M3UA Peer Server (Only available if Psrv was chosen as the route type) Associates a peer server with an M3UA route
M3UA User Part Associates a userpart with an M3UA route
Point Code Associates a point code with the M3UA route
Point Code Mask Sets a scheme for accepting point codes in an M3UA route. By default, the only available value is “Exact match”.
Sub-Service Field Type Sets a type for the sub-service field (SSF) of an M3UA route.
Configuring an M3UA System on a Signaling Gateway 184


Creating an M3UA Configuration (ASP) To set up your M3UA system on an application server process (ASP), you must first create a new M3UA con figuration. In this configuration the SS7 MTP2 layer is replaced entirely by the SIGTRAN M3UA layer, and the MTP3 layer is extended over the IP network. To create an M3UA configuration on an ASP:
Figure 309. SS7 > M3UA
– Enter a name for the configuration
– Select Application Server Process (ASP) as the node type
Figure 310. Creating the New M3UA (ASP) Configuration
Figure 311. Successful Configuration Message
Understanding Parameters for M3UA Configurations
Table 72. Configuration Parameters for New M3UA Configurations
Name Used by the Web Portal to indicate a specific object or string in the system
Node Type Assigns a configuration to an M3UA network. Possible values: Signaling Gateway Process (SGP) Application Server Process (ASP) IP Server Process (IPSP)
Configuring an M3UA System on an Application Server 186

Creating an M3UA Peer Signaling Process (ASP) After you have created M3UA user part, you must create a new M3UA peer signaling process (PSP). A PSP is used to describe a remote SGP that is accessible through the M3UA system. To create an M3UA Peer Signal ing Process (PSP) on an ASP system:
Figure 312. M3UA Network Configuration Window: Create M3UA PSP
– Enter a name for the PSP
– Select Application Server Process (SGP) as the PSP type
– Enter a destination port (as configured in the destination element)
Figure 313. Creating the New M3UA PSP (ASP)
Figure 314. Successful M3UA PSP Message
– Select a SAP from the list of available SAPs
– Click the "<<" button to associate it with the PSP.
Figure 315. Associating SAPs with the M3UA PSP
Configuring an M3UA System on an Application Server 187

– Enter a destination address
– Click the "<<" button to add the destination address to the PSP
– Verify that the "(your address) was successfully added" message appears.
Figure 316. Editing Destination Address for the PSP
Understanding Parameters for M3UA PSPs
Table 73. Configuration Parameters for New M3UA PSPs
Name Used by the Web Portal to indicate a specific object or string in the system
PSP Type Assigns a configuration to an M3UA peer signaling process. Possible values: Signaling Gateway Process (SGP) Application Server Process (ASP) IP Server Process (IPSP)
Destination Port Sets a destination for a line in a system using SIGTRAN protocols
Configuring an M3UA System on an Application Server 188

Creating an M3UA ISUP Network After you have created an initial ISUP stack, you must create a new ISUP network. The ISUP network tells the ISUP protocol layer about a collection of SS7 nodes that are accessible through MTP3 or M3UA. Based upon your system configuration, one or more ISUP networks are created. Repeat this section for as many networks as you require.
To create an M3UA ISUP network:
Figure 317. Editing ISUP Networks
– Enter a name for the network
– Select M3UA as the type of network to bind
– Select an M3UA Userpart
Figure 318. Creating the New M3UA ISUP Network
Figure 319. Successful ISUP Network Message
Configuring an M3UA System on an Application Server 189

Understanding Parameters for M3UA ISUP Networks
Table 74. Configuration Parameters for New M3UA ISUP Network
Name Used by the Web Portal to indicate a specific object or string in the system
Type of Network to Bind Indicates the type of network to associate with an ISUP Network Possible values: MTP3/M3UA
M3UA Userpart Associates a userpart with an M3UA route
Configuring an M3UA System on an Application Server 190


Smart Media Software Configuration Guide 6 • Configuring CAS R2
The Smart Media Software allows you to configure CAS R2 signaling stacks. Refer to the following sections to configure CAS R2:
When you receive a new system, at least one hardware configuration will have been set in the Smart Media application server, by default. To add other hardware devices, you must use the Smart Media Web Portal. To add one or more additional hardware devices to the Smart Media system configuration, their serial numbers must be registered with the Smart Media application server.
To add a hardware device:
Figure 321. config_patton > Hardware
Figure 322. Hardware List
– Enter a name for the hardware device
– Enter the serial number of the new hardware device (filling in the Serial Number field will cause auto-
completion of the field to occur).
Overview 192

Smart Media Software Configuration Guide 6 • Configuring CAS R2
– Select the appropriate hardware device from the Adapter Type field.
– Select Enabled from the Target State field.
Figure 323. Creating the New Hardware Device
Figure 324. Successful Device Message
Adding an Adapter 193

Smart Media Software Configuration Guide 6 • Configuring CAS R2
Understanding Parameters for Hardware Adapters
Table 75. Configuration Parameters for New Hardware Adapters
Name Used by the Web Portal to indicate a specific object or string in the system
Serial Defines a product serial number, when creating a new hardware device. Enter ing characters into the Serial field will cause the number to auto-complete.
Adapter Type Specifies the type of hardware device being created, when adding a new adapter. Possible values: TMP/TMS
Sets a maximal delay for calls to terminate normally before an adapter is upgraded
Location Identifies the physical location of a hardware adapter
Description Describes the purpose of a particular hardware adapter
Target State Sets the live state of a hardware adapter. Possible values: Disabled/Probation/Enabled
Creating Line Interfaces Line interface is a generic term for TDM physical interfaces. The SmartNode 10200 Series supports three types of physical interfaces: T1/E1/J1 interfaces, DS3 interfaces, and Oc3/STM1 interfaces.
To create a new line interface:
Figure 325. TDM Interfaces > Line Interfaces
Figure 326. Line Interface List
– Enter a name for the interface
– Set a type for the interface
Adding an Adapter 194
Graceful Upgrade Timeout

Smart Media Software Configuration Guide 6 • Configuring CAS R2
– Set a local index for the line
– Select a length and an encoding scheme
Figure 327. Create New Line Interface
Figure 328. Confirmation Message for New Line Interface
Understanding Parameters for Line Interfaces
Table 76. Configuration Parameters for New Line Interfaces
Name Used by the Web Portal to indicate a specific object or string in the system
Type Defines the type of line interface: E1/DS3/T1/J1/STM1/OC3
Local Index Assigns an integer to represent an object
Length Indicates the physical length of a line: Short/Long/Autodetect/Monitoring
Encoding Sets an encoding scheme for a line interface. Values depend on the interface type:
HDB3/AMI B3ZS B8ZS/AMI/AMI CLEAR (None)
Adding an Adapter 195

Smart Media Software Configuration Guide 6 • Configuring CAS R2
Creating Line Services You must create a new line service for your line interface. A line service defines the payload type of a line inter face or another line service. The line service chain stops when it reach the E1/J1/T1 line service. The E1/J1/T1 line services are also known as trunks or spans.
To create a new line service:
Figure 329. TDM Interfaces > Line Interfaces
Figure 330. Line Interface List
Figure 331. Editing a Line Interface to Create a New Service
– Enter a name for the new line
– Select an available local index, from the drop-down box
– Select appropriate framing and loopback modes
Adding an Adapter 196

Smart Media Software Configuration Guide 6 • Configuring CAS R2
Figure 332. Create New Line Service
Figure 333. Line Services List
Adding an Adapter 197

Smart Media Software Configuration Guide 6 • Configuring CAS R2
Table 77. Configuration Parameters for New Line Services
Name Used by the Web Portal to indicate a specific object or string in the system
Local Index Assigns an integer to represent an object
Framing Sets a framing type for a line service. Select from: AUTO (typical for E1)/STD/MFRAME/SF/ESF (typical for T1)/SLC96
Loopback Used to set a loopback state for a line service. Refer to table 78 for details.
Table 78. Loopback Types
Loopback Type Description Behavior Use
All traffic is received and sent on the line Always
LINE Analog Line Loopback
All received traffic is re-routed on the transmit line. The clock and data recovered from the line inputs are routed back to the line outputs of the analog transceiver bypassing the framer modules.
First step in testing a physical connection
PAYLOAD Digital Line Loopback
All received traffic is re-routed on the transmit line.The clock and data recovered from the line inputs are routed back to the line outputs after the deframer/framer.
Second step in testing a physical connection. This tests the framer configuration.
This forces the transmit line to stop sending. This is the second-best thing to disconnecting the line interface physi cally.
LOCAL Local Loopback All received traffic is dropped. The traffic sent
Never. Used for inter nal testing only
is re-routed internally.
Adding an Adapter 198
NONE Normal Operation · GENERATE_LOS Generate Loss · of Signal

Smart Media Software Configuration Guide 6 • Configuring CAS R2
If you plan to modify an existing CASR2 script, you may optionally create a copy of that script first.
Figure 334. Menu > CASR2 Scripts
Figure 335. Copy from Scripts List
– Enter a new name for the script
Figure 336. Creating a New Script File
Figure 337. Successful Script File Message
Figure 338. User Scripts List
Copying a Variant Script (optional) 199

Smart Media Software Configuration Guide 6 • Configuring CAS R2
Now that the necessary underlying structures have been configured, you must create a new CAS R2 stack.
The Smart Media CAS R2 stack features a scriptable register signaling engine that, in practice, allows the com plete customization of communication processes using tones. More specifically, it is possible to modify the tim ing(s) of the tone exchanges, change the meaning(s) of each tone and dynamically specify the sequence in which the tones are played. The CAS R2 stack also provides integrated interoperability between variants and between other signaling types. For instance, the calling party category can be converted between variants and propagated to a SS7 call leg. To create a CAS R2 stack:
Figure 339. Signaling > CASR2
Figure 340. CASR2 Stack List
– Make sure the Enabled box is checked
– Enter a name for the stack
– Select a line service
– Select a variant script
Figure 341. Creating the New CAS R2 Stack
Creating a CAS R2 Stack 200

Smart Media Software Configuration Guide 6 • Configuring CAS R2
Table 79. Configuration Parameters for CAS R2 Stacks
Enabled Indicates whether or not an object is to be implemented or not
Name Used by the Web Portal to indicate a specific object or string in the system
Line Service Indicates which TDM line service is to be associated with the object being created
Variant Script Sets a regional script for a CAS R2 signaling. Possible values: brazil.lua / itu.lua
After you have created a CAS R2 stack, you must create a network access point, in order to finish configuring your system. A Network Access Point (NAP) represents the entry point to another network or destination peer.
To create a network access point (NAP):
Figure 342. Menu > NAP
Figure 343. Network Access Point List
– Enter a name for the NAP
– Select a user-created profile. If none, select default.
Creating a CAS R2 NAP 201

Smart Media Software Configuration Guide 6 • Configuring CAS R2
Figure 344. Creating New CAS R2 NAP
Figure 345. Successful NAP Message
– Select an interface (the newly-created CASR2 stack)
– Click the "<<" button to add the interface to the list
Figure 346. Associating a CAS R2 Stack with the NAP
Figure 347. Successful NAP Update Message
Table 80. Configuration Parameters for NAPs
Name Used by the Web Portal to indicate a specific object or string in the system
Default Profile Sets a profile for a NAP. The default value is simply labeled "Default", but can be changed if alternate profiles have been created.
Creating a CAS R2 NAP 202
– Click Save


Smart Media Software Configuration Guide 7 • Configuring H.248
Refer to the following sections to configure the H.248 media gateway control protocol:
– “Allocating a VoIP network access point (NAP)” on page 212
– “Allocating a TDM Network Access Point (NAP)” on page 213
When you receive a new system, at least one hardware configuration will have been set in the Smart Media application server, by default. To add other hardware devices, you must use the Smart Media Web Portal. To To add a hardware device:
Figure 348. config_patton > Hardware
Figure 349. Hardware List
Overview 204

Smart Media Software Configuration Guide 7 • Configuring H.248
– Enter a name for the hardware device
– Enter the serial number of the new hardware device (filling in the Serial Number field will cause auto-
completion of the field to occur).
– Select the appropriate hardware device from the Adapter Type field.
– Select Enabled from the Target State field.
Figure 350. Creating the New Hardware Device
Figure 351. Successful Device Message
Adding an Adapter 205

Smart Media Software Configuration Guide 7 • Configuring H.248
Understanding Parameters for Hardware Adapters
Table 81. Configuration Parameters for New Hardware Adapters
Name Used by the Web Portal to indicate a specific object or string in the system
Serial Defines a product serial number, when creating a new hardware device. Enter ing characters into the Serial field will cause the number to auto-complete.
Adapter Type Specifies the type of hardware device being created, when adding a new adapter. Possible values: TMP/TMS
Sets a maximal delay for calls to terminate normally before an adapter is upgraded
Location Identifies the physical location of a hardware adapter
Description Describes the purpose of a particular hardware adapter
Target State Sets the live state of a hardware adapter. Possible values: Disabled/Probation/Enabled
Creating Line Interfaces Line interface is a generic term for TDM physical interfaces. The SmartNode 10200 Series supports three types of physical interfaces: T1/E1/J1 interfaces, DS3 interfaces, and Oc3/STM1 interfaces.
To create a new line interface:
Figure 352. TDM Interfaces > Line Interfaces
Figure 353. Line Interface List
– Enter a name for the interface
– Set a type for the interface
Adding an Adapter 206
Graceful Upgrade Timeout

Smart Media Software Configuration Guide 7 • Configuring H.248
– Set a local index for the line
– Select a length and an encoding scheme
Figure 354. Create New Line Interface
Figure 355. Confirmation Message for New Line Interface
Understanding Parameters for Line Interfaces
Table 82. Configuration Parameters for New Line Interfaces
Name Used by the Web Portal to indicate a specific object or string in the system
Type Defines the type of line interface: E1/DS3/T1/J1/STM1/OC3
Local Index Assigns an integer to represent an object
Length Indicates the physical length of a line: Short/Long/Autodetect/Monitoring
Encoding Sets an encoding scheme for a line interface. Values depend on the interface type:
HDB3/AMI B3ZS B8ZS/AMI/AMI CLEAR (None)
Adding an Adapter 207

Smart Media Software Configuration Guide 7 • Configuring H.248
Creating Line Services You must create a new line service for your line interface. A line service defines the payload type of a line inter face or another line service. The line service chain stops when it reach the E1/J1/T1 line service. The E1/J1/T1 line services are also known as trunks or spans.
To create a new line service:
Figure 356. TDM Interfaces > Line Interfaces
Figure 357. Line Interface List
Figure 358. Editing a Line Interface to Create a New Service
– Enter a name for the new line
– Select an available local index, from the drop-down box
– Select appropriate framing and loopback modes
Adding an Adapter 208

Smart Media Software Configuration Guide 7 • Configuring H.248
Figure 359. Create New Line Service
Figure 360. Line Services List
Understanding Parameters for Line Services
Table 83. Configuration Parameters for New Line Services
Name Used by the Web Portal to indicate a specific object or string in the system
Local Index Assigns an integer to represent an object
Framing Sets a framing type for a line service. Select from: AUTO (typical for E1)/STD/MFRAME/SF/ESF (typical for T1)/SLC96
Loopback Used to set a loopback state for a line service. Refer to table 84 for details.
Table 84. Loopback Types
Loopback Type Description Behavior Use
All traffic is received and sent on the line Always
LINE Analog Line Loopback
All received traffic is re-routed on the transmit line. The clock and data recovered from the line inputs are routed back to the line outputs of the analog transceiver bypassing the framer modules.
First step in testing a physical connection
PAYLOAD Digital Line Loopback
All received traffic is re-routed on the transmit line.The clock and data recovered from the line inputs are routed back to the line outputs after the deframer/framer.
Second step in testing a physical connection. This tests the framer configuration.
Adding an Adapter 209
NONE Normal Operation

Smart Media Software Configuration Guide 7 • Configuring H.248
Table 84. Loopback Types
Loopback Type Description Behavior Use
This forces the transmit line to stop sending. This is the second-best thing to disconnecting the line interface physi cally.
LOCAL Local Loopback All received traffic is dropped. The traffic sent
Never. Used for inter nal testing only
is re-routed internally.
Creating an IP port range After you have properly allocated all of your system's physical interfaces, you must create a new IP port range.
Figure 362. Editing Port Ranges
– Enter a name for the port range
– Select an IP interface
– Enter a port min value (must be at least 1024)
– Enter a port max value
Creating an IP Port Range 210
GENERATE_LOS Generate Loss · of Signal

Smart Media Software Configuration Guide 7 • Configuring H.248
Figure 363. Creating a New Port Range
Figure 364. Confirmation Message for Port Range
Table 85. Configuration Parameters for New IP Port Ranges
Name Used by the Web Portal to indicate a specific object or string in the system
IP Interface Identifies an IP interface that is to be associated with the structure being created
Port Min Sets a minimum value for an IP port range. Since only even-numbered ports will be used to send RTP over, it is recommended that the Port Min value be at least 1000
Port Max Sets a maximum value for an IP port range. Since only even-numbered ports will be used to send RTP over, it is recommended that the Port Min value be at least 1000. Ex.: 10000-20000 --> 5000 connections
Creating an IP Port Range 211

Smart Media Software Configuration Guide 7 • Configuring H.248
A network access point or NAP represents the entry point to another network or destination peer (e.g. SIP proxy, ISUP interface peer, etc).
Allocating a VoIP network access point (NAP) Now that you have created the necessary IP port ranges, you must allocate a VoIP network access point for your system.
Figure 366. Edit NAP List
– Enter a name for the NAP
Figure 367. Creating the New VoIP NAP
Figure 368. Confirmation Message for New NAP
Configuring Network Access Points (NAPs) 212

Smart Media Software Configuration Guide 7 • Configuring H.248
– Select VoIP media from the VoIP Media Only menu (this is the port range that was created earlier)
– Click the "<<" button to associate it with the NAP
Figure 369. Associating VoIP Media with the New NAP
Understanding Parameters for VoIP NAPs
Table 86. Configuration Parameters for VoIP NAPs
Name Used by the Web Portal to indicate a specific object or string in the system
Allocating a TDM Network Access Point (NAP) You must now allocate a TDM network access point for your system. A network access point or NAP repre sents the entry point to another network or destination peer (e.g. SIP proxy, ISUP interface peer, etc).
Figure 371. Edit NAP List
– Enter a name for the NAP
Configuring Network Access Points (NAPs) 213

Smart Media Software Configuration Guide 7 • Configuring H.248
Figure 372. Creating the New TDM NAP
Figure 373. Confirmation Message for New NAP
– Select a line service from the LS Media Only menu (this is the line service that was created earlier)
– Click the "<<" button to associate it with the NAP
Figure 374. Associating VoIP Media with the New NAP
Understanding Parameters for TDM NAPs
Table 87. Configuration Parameters for TDM NAPs
Name Used by the Web Portal to indicate a specific object or string in the system
Configuring Network Access Points (NAPs) 214

Smart Media Software Configuration Guide 7 • Configuring H.248
To configure the media gateway for H.248:
Figure 375. Menu > Configurations
Figure 376. Setting the Application Mode to H.248
Configuring the Media Gateway for H.248 Mode 215
– Select H248 · – Click Save

Smart Media Software Configuration Guide 7 • Configuring H.248
After you have created the necessary VoIP and TDM NAPs, you are ready to create a new H.248 configura tion.
Figure 377. Gateway > H248
– Select a transport protocol type
– Enter a public IP address
– Enter a private IP address
Figure 378. Creating the New H.248 Configuration
Figure 379. Successful Configuration Message
Creating an H.248 Configuration 216

Smart Media Software Configuration Guide 7 • Configuring H.248
Table 88. Configuration Parameters for H.248 Configuration
Transport Protocol Type Sets the kind of protocol handled by an H.248 configuration. Possible values: UDP / SCTP
Public IP Address Sets an address for externally accessing an H.248 configuration
Private IP Address Sets an address for privately accessing an H.248 configuration
After you have created the H.248 configuration, you must create a new media gateway controller (MGC).
A Media Gateway Controller (MGC) is a system used in VoIP architectures to control a number of Media Gateway terminals.:
Figure 380. H.248 MGCs
– Enter a name for the MGC
– Enter an IP address
Figure 381. Creating a New H.248 MGC
Figure 382. Successful MGC Message
Adding a New Media Gateway Controller (MGC) 217

Smart Media Software Configuration Guide 7 • Configuring H.248
Table 89. Configuration Parameters for Media Gateway Controller
Name Used by the Web Portal to indicate a specific object or string in the system
IP Address Sets an address for accessing a new media gateway controller (MGC)
You must now associate the TDM and VoIP network access points (NAPs) you previously created with the H.248 configuration:
Figure 383. Gateway > H248
– Select a NAP from the TDM Media list
– Click the "<<" button to associate the NAP with your H.248 configuration.
Figure 384. Associating a TDM NAP
– Select a NAP from the TDM Media list
– Click the "<<" button to associate the NAP with your H.248 configuration
Figure 385. Associating a VoIP NAP
Associating NAPs with the H.248 Configuration 218

Smart Media Software Configuration Guide 7 • Configuring H.248
Finally, you must assign timeslots to the TDM interfaces that have been associated with the H.248 configura tion:
Figure 386. MG H.248 TDM Terminations Window
– Add the desired timeslots by checking individual boxes, or simply select all times by clicking Select all
Figure 387. Enabling Timeslots
Figure 388. Successful Update Message
Selecting Timeslots for TDM Interfaces 219
– Click Save


Smart Media Software Configuration Guide 8 • Configuring SNMP
To use the Simple Network Management Protocol (SNMP)on your machine, you must first configure the tbSnmpAgent. The tbSnmpAgent is a software application that interfaces between the Smart Media system hardware and the NetSnmp implementation of the SNMP that is supported by Patton. By default, tbSn mpAgent is disabled. In order to use the SNMP protocol to monitor and manage your hardware, complete the following tasks:
Once these tasks are completed, your Smart Media platform is ready to expose system variables for polling with the Simple Network Management Protocol (SNMP).
Before starting, make sure that the SELinux service is disabled, or else it will prevent the SNMP service from starting. Then, you may activate SNMP through the Web Portal.
Disabling the SELinux Service To disable the SELinux service (so that it does not interfere with the SNMP agent):
# This file controls the state of SELinux on the system. # SELINUX= can take one of these three values: # enforcing - SELinux security policy is enforced. # permissive - SELinux prints warnings instead of enforcing. # disabled - SELinux is fully disabled. SELINUX=disabled # SELINUXTYPE= type of policy in use. Possible values are: # targeted - Only targeted network daemons are protected. # strict - Full SELinux protection. SELINUXTYPE=targeted
shutdown -r now or setenforce 0
sestatus · vi /etc/selinux/config · Overview 221

Smart Media Software Configuration Guide 8 • Configuring SNMP
Activating the tbSnmpAgent application After you have disabled the SELinux service, log into the Web Portal and follow the steps below to activate SNMP:
Figure 389. Global > Status
Figure 390. Status > Applications tab
Figure 391. Applications > Not running list
Figure 392. Application Instance Status Window
Activating the tbSnmpAgent 222

Smart Media Software Configuration Guide 8 • Configuring SNMP
Figure 393. Applications > Ready list
The tbSnmpAgent application has now been activated.
Once you are logged into the Web Portal and have successfully activated the tbSnmpAgent application, follow these steps to configure the application to suit your needs:
Configuring SNMP system parameters 1. Under the Applications heading, in the Web Portal navigation panel, click the Configurations tab.
Figure 394. Applications > Configurations
Figure 395. Application Configuration List
Configuring the tbSnmpAgent 223

Smart Media Software Configuration Guide 8 • Configuring SNMP
Figure 396. Application Params section
– Polling delay to generate traps: this sets the length for the time intervals at which the SNMP agent
polls for newly generated traps. The value entered is in seconds.
Figure 397. Application Params > Polling Delay
Configuring the tbSnmpAgent 224

Smart Media Software Configuration Guide 8 • Configuring SNMP
Configuring SNMPv1, SNMPv2c 1. Under the SNMPv1 SNMPv2c Communities heading, new communities can be created for SNMP:
– By default, there are standard communities: public (read-only access), and private (read-write access).
– Click Create new community to create a new community for SNMPv1 or SNMPv2.
Figure 398. Create New SNMP Community window
Configuring SNMPv3 1. Under the SNMPv3 Users heading, new users can be created for SNMP version 3:
– By default, no SNMPv3 users are created
– Click Create new SNMPv3 user to create a new user definition for SNMPv3
Figure 399. Create New SNMP User window
Configuring traps 1. Under the SNMP Trap Destinations heading, destination addresses for SNMP traps can be defined:
– By default, no SNMP trap destinations are defined
– Click Create New SNMP Trap Destination to create a new destination to send SNMP traps
Figure 400. Create New SNMP Trap Destination window
Configuring the tbSnmpAgent 225


Smart Media Software Configuration Guide 9 • Contacting Patton
This chapter contains the following information:
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
Patton support headquarters in the USA • Online support: available at www.patton.com
Alternate Patton support for Europe, Middle East, and Africa (EMEA) • Online support: available at www.patton.com
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.
Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Introduction 227

Smart Media Software Configuration Guide 9 • Contacting Patton
Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro- phes may require replacement.
Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 228
Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.