NL
Peerless Industries logo
Officiële handleiding

Peerless Industries SF 630P

23 pagina's·2.8 MB·Tv-beugel·PDF·EN
Peerless Industries SF 630P
Inhoudsopgave 18 secties Models: SF630P, SF630P-S, SF630, SF630-S · © U L US C · ISSUED: 04-18-05 SHEET #: 201-9427-7 04-20-10 · WALL CONSTRUCTION HARDWARE REQUIRED · … TonenVerbergen
Page 1 of the Peerless Industries SF 630P user manual — ISSUED: 04-18-05 SHEET #: 201-9427-7 04-20-10
Pagina 1 · klik om te vergroten
Pagina 1

Installation and Assembly: Universal Flat Wall Mount for 10" - 24" (25 - 61 cm) LCD Flat Panel Screens

Models: SF630P, SF630P-S, SF630, SF630-S

Peerless Industries SF 630P — Models: SF630P, SF630P-S, SF630, SF630-S diagram (page 1)
Afb. 1 · Models: SF630P, SF630P-S, SF630, SF630-S
  • Features:
  • For 10" - 24" (25 - 61 cm) fl at panel screens
  • Ultra-slim design holds the screen fl at against the wall

© U L US C

:

Max UL Load Capacity80 lb (36.3 kg)

ISSUED: 04-18-05 SHEET #: 201-9427-7 04-20-10

Page 3 of the Peerless Industries SF 630P user manual — G H F E C
Pagina 3 · klik om te vergroten
Pagina 3

Before you begin, make sure all parts shown are included with your product. Parts may appear slightly different than illustrated.

Parts List

SF 630P SF 630P-S SF 630 SF 630-S Description Qty Part # Part # Part # Part # A wall plate 1 095-1320 095-4320 095-1320 095-4320 B hook bracket 1 095-1321 095-4321 095-1321 095-4321 C M5 x 12 mm screw 2 520-1027 520-1027 520-1064 520-1064 D M4 x 10 mm phillips screw 4 504-9012 E M4 x 20 mm phillips screw 4 504-9020 F retaining spacer 4 590-5005 G #14 x 2.5" wood screw 2 5S1-015-C03 H concrete anchor 2 590-0320 I 4 mm security allen wrench 1 - - 560-1145 560-1145

Peerless Industries SF 630P — Parts List diagram (page 3)
Afb. 2 · Parts List
Peerless Industries SF 630P — Parts List diagram (page 3)
Afb. 3 · Parts List
Peerless Industries SF 630P — Parts List diagram (page 3)
Afb. 4 · Parts List

G H F E C

Peerless Industries SF 630P — G H F E C diagram (page 3)
Afb. 5
Page 4 of the Peerless Industries SF 630P user manual — Installation to Single Wood Stud Wall
Pagina 4 · klik om te vergroten
Pagina 4

Installation to Single Wood Stud Wall

  • Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
  • Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is highly recommended.
  • Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).

Use a stud fi nder to locate the edges of the stud. Use of an edge-to-edge stud fi nder is highly recommended. Based on its edges, draw a vertical line down the stud’s center. Place wall plate (A) on wall as a template, making sure that the two mounting holes are over the stud centerline. Level plate, and mark the center of the two holes. Drill two 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Make sure that the wall plate is level, secure it using two #14 x 2.5" wood screws (G) as shown.

Skip to step 2.

Peerless Industries SF 630P — Installation to Single Wood Stud Wall diagram (page 4)
Afb. 6 · Installation to Single Wood Stud Wall
Page 5 of the Peerless Industries SF 630P user manual — CINDER BLOCK SOLID CONCRETE
Pagina 5 · klik om te vergroten
Pagina 5

Installation to Solid Concrete or Cinder Block

  • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
  • Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
  • Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.

Make sure that wall plate (A) is level, use it as a template to mark two mounting holes. Drill two 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (H) in holes fl ush with wall as shown (right). Place wall plate over anchors and secure with two #14 x 2.5" screws (G). Level, then tighten all fasteners.

H

Drill holes and insert anchors (H).

A

  • Tighten screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

H G

Place plate (A) over anchors (H) and secure with screws (G).

  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Always attach concrete expansion anchors directly to load-bearing concrete.
  • Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other fi nishing material. If mounting to concrete surfaces covered with a fi nishing surface is unavoidable (not evaluated by UL), the fi nishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).

Tighten all fasteners.

CINDER BLOCK SOLID CONCRETE

INCORRECT CORRECT

H

CUTAWAY VIEW

A

G

Show 6 more labels / short text on this page
concrete surface · concrete concrete · wall plate · wall plate · plaster/ dry wall · plaster/ dry wall
Page 6 of the Peerless Industries SF 630P user manual — fi g. 2.1 fi g. 2.2
Pagina 6 · klik om te vergroten
Pagina 6

Attaching Hook Bracket to Flat Panel Screen Using VESA 75 and 100 mm mounting patterns

Thread M5 phillips screws (C) to hook bracket (B) making the screws fl ush with bracket as shown in fi gures 2.1 and 2.2. 2

B

B

fi g. 2.1 fi g. 2.2

Peerless Industries SF 630P — fi g. 2.1 fi g. 2.2 diagram (page 6)
Afb. 7 · fi g. 2.1 fi g. 2.2
  • If screws don't get three complete turns in the screen inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to screen or product may fail.

FOR VESA 75 MOUNTING PATTERN: Choose hole pattern as shown below. Attach hook bracket (B) to back of screen using four M4 x 10 mm screws (D) as shown below.

FOR VESA 100 MOUNTING PATTERN: Choose hole pattern as shown below. Attach hook bracket (B) to back of screen using four M4 x 10 mm screws (D) as shown below.

*Note: If hole pattern is in a pocket, attach hook bracket (B) to back of screen using four M4 x 20 mm screws (E) and four spacers (F) as indicated below.

Peerless Industries SF 630P — fi g. 2.1 fi g. 2.2 diagram (page 6)
Afb. 8 · fi g. 2.1 fi g. 2.2

*For screens with a hole pattern in a pocket, spacers (F) go between adapter plate (B) and screen. F

Page 7 of the Peerless Industries SF 630P user manual — Installing and Removing Flat Panel Screen
Pagina 7 · klik om te vergroten
Pagina 7

Installing and Removing Flat Panel Screen

6 A SCREEN

Hook screen onto wall plate (A) fi gure 6.1. Tighten M5 x 12 mm screws (C), shown in fi gure 6.2 and detail 1.

Peerless Industries SF 630P — Installing and Removing Flat Panel Screen diagram (page 7)
Afb. 9 · Installing and Removing Flat Panel Screen

To remove screen from mount, loosen screws (C) and lift screen off of mount.

Peerless Industries SF 630P — Installing and Removing Flat Panel Screen diagram (page 7)
Afb. 10 · Installing and Removing Flat Panel Screen
  • Do not lift more weight than you can handle. Use additional man power or mechanical lifting equipment to safely handle placement of the screen.
  • Failure to lock hook bracket with screws ( C ) can cause screen to come off mount if hit accidentally.
  • Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten screws to 20 in.
  • lb (2.26 N.M.) maximum torque.
Peerless Industries SF 630P — Installing and Removing Flat Panel Screen diagram (page 7)
Afb. 11 · Installing and Removing Flat Panel Screen

© 2009, Peerless Industries, Inc. All rights reserved. All other brand and product names are trademarks or registered trademarks of their respective owners.

Peerless Industries, Inc.

3215 W. North Ave. Melrose Park, IL 60160 www.peerlessmounts.com

Page 8 of the Peerless Industries SF 630P user manual — PUBLICADO: 04-18-05 HOJA #: 201-9427-7 04-20-10
Pagina 8 · klik om te vergroten
Pagina 8

Instalación y ensamblaje: Soporte universal de pared plano para pantallas planas de LCD de 10" - 24" (25 - 61 cm)

Modelos: SF630P, SF630P-S, SF630, SF630-S

Peerless Industries SF 630P — Modelos: SF630P, SF630P-S, SF630, SF630-S diagram (page 8)
Afb. 12 · Modelos: SF630P, SF630P-S, SF630, SF630-S
  • Características:
  • Para pantallas planas de 10" - 24" (25 - 61 cm)
  • El diseño ultra esbelto sostiene la pantalla a ras de la pared

© U L US C

:

Máxima capacidad de UL carga:

80 lb (36.3 kg)

PUBLICADO: 04-18-05 HOJA #: 201-9427-7 04-20-10

Vraag stellen over de Peerless Industries SF 630P

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Peerless Industries SF 630P

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Peerless Industries SF 630P handleiding-pdf

23 pagina's·2.8 MB·Tv-beugel·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…