Gebruiksaanwijzing /service van het product BB08 van de fabrikant Pelco
Ga naar pagina of 20
BB08 Series Inter cept ® Back Box Installation/ Operation Manual C456M-D (1/98) Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-910.
2 Pelco Manual C456M-D (1/98) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 3 1.1 IMPORT ANT SAFEGU ARDS AND W ARNINGS ............................... 3 1.2 UNP A CKING INSTR UCTIONS .
Pelco Manual C456M-D (1/98) 3 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser v ed.
4 Pelco Manual C456M-D (1/98) 1.2 UNP ACKING INSTRUCTIONS Unpack and inspect all parts carefully . Be sure to sav e the shipping carton and any inser ts.
Pelco Manual C456M-D (1/98) 5 2.0 DESCRIPTION The BB08 Series of back bo xes is part of the IDS08 Intercept ® Series of domes. The IDS08 Series is an integral system that includes a back bo x (BB08), dome drive (DD08), dome receiv er/driver (DRD08), and imager/optics package (IOP08).
6 Pelco Manual C456M-D (1/98) 3.0 INST ALLA TION 3.1 SUSPENDED CEILING 1. Remov e the ceiling tile from the ceiling. If you are installing the back bo x into a 2' x 4' (61 x 122 cm) ceiling grid, cut the tile in half and install an additional “T” bar for support.
Pelco Manual C456M-D (1/98) 7 T able A. Video Coaxial Cable Requirements Cable T ype* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) * Minimum cable requirements.
8 Pelco Manual C456M-D (1/98) 3. T o create an opening for the wiring, use a hammer and punch to remov e one of the knock outs in the top of the back bo x.
Pelco Manual C456M-D (1/98) 9 Figure 2. 24 V AC Bac k Box Wiring Diagram.
10 Pelco Manual C456M-D (1/98) Figure 3. 120 V AC Bac k Bo x Wir ing Diagram.
Pelco Manual C456M-D (1/98) 11 12. If you are not using Coaxitron ® control, connect the control wiring to RXD+ and RXD-. F rom controller T o 4-wire terminal inside back bo x TXD+ RXD+ TXD- RXD- 13. Back bo x installation is now complete . Proceed with the installation of the dome drive unit.
12 Pelco Manual C456M-D (1/98) 13. If you are not using Coaxitron ® control, connect the control wiring to RXD+ and RXD-. F rom controller T o 4-wire terminal inside back box TXD+ RXD+ TXD- RXD- 14. The bezel and dome assemb ly can be attached to the back bo x at this time, or it can be done after the dome drive is installed.
Pelco Manual C456M-D (1/98) 13 Figure 4. BB08A120 Back Bo x Exploded Assembly Diagram 4.0 EXPLODED ASSEMBL Y DIAGRAMS E F A B 4 C D 6 2 3 5 7 8 1.
14 Pelco Manual C456M-D (1/98) Figure 5. BB08E120 and BB08E211 Bac k Bo x es Exploded Assembly Diag ram.
Pelco Manual C456M-D (1/98) 15 T able C. BB08A120 Back Bo x Exploded Assembly P ar ts List (Figure 4) Item Quantity Description Part Number 1 1 T rim ring, white 8082ASSY 1 Dome seal (not shown) 80810.
16 Pelco Manual C456M-D (1/98) Figure 6. Back Plate Exploded Assemb ly Diagram.
Pelco Manual C456M-D (1/98) 17 T able E. Back Plate Exploded Assembly P ar ts List Item Quantity Description Part Number 1 2 Latch backup plate 8004244COMP 2 2 Latch 8004105COMP 3 2 Latch bracket 8004143COMP 4 1 T ransformer (120 V A C model only) TRF21243.
18 Pelco Manual C456M-D (1/98) 5.0 SPECIFICA TIONS ELECTRICAL Enclosure Back Box Input Voltage: 24 VAC or 120 VAC Power Requirements Receiver/Driver: 48 vA for 24 VAC and 120 VAC dome drives Blower (continuous duty): One (1) at 33 cfm, 6.
Pelco Manual C456M-D (1/98) 19 Figure 7. BB08A120 Dimension Drawings Figure 8. BB08E120 and BB08E211 Dimension Dra wing NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES NOTE: VALUES .
20 Pelco Manual C456M-D (1/98) 6.0 WARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 1998, P elco . All rights reserved.
Een belangrijk punt na aankoop van elk apparaat Pelco BB08 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco BB08 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco BB08 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco BB08 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco BB08 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco BB08 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco BB08 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco BB08 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.