Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108 Inte.
2 Pelco Manual C1488M-A (9/98) REVISION HISTOR Y Manual # Date Comments C1488M 6/98 Original version. C1488M-A 9/98 Rev A. Re vised the manual to incorporate Spectra™ Lite material. CONTENTS Section Page 1.0 GENERAL .................................
Pelco Manual C1488M-A (9/98) 3 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser v ed. 1. Installation and servicing should only be done by qualified ser vice personnel and conform to all local codes.
4 Pelco Manual C1488M-A (9/98) 1.2 REGULA TOR Y NOTICES NOTE: This equipment has been tested and found to comply with the limits of a Class B digital de vice, pursuant to par t 15 of the FCC rules. These limits are de- signed to provide reasonab le protection against harmful interference in a residen- tial installation.
Pelco Manual C1488M-A (9/98) 5 Figure 1. Back Bo x P arts COMPASS TOOL SAFETY BRACKET CONDUIT FITTING & LOCK NUT T -RAIL CLIP 1.3 UNP ACKING INSTRUCTIONS Unpack and inspect all parts carefully . Be sure to sav e the shipping box and an y inser ts.
6 Pelco Manual C1488M-A (9/98) 2.0 DESCRIPTION The BB5A Series back bo xes are used with the SD5 Series of Spectra™ (Softw are V ersion 3.0) domes and SD5A Series of Spectra II™ domes. The BB5L Series back bo xes are used with the SD5L Series of Spectra™ Lite domes.
Pelco Manual C1488M-A (9/98) 7 3.0 INST ALLA TION FOR IN-CEILING MODELS This manual cov ers the installation of the BB5A-F , BB5A-PB , BB5A-PG, BB5A-PG-E, BB5L-F , BB5L-PG, and BB5L-PG-E back bo x es only . For complete installation and operating instructions f or the SD5 Series of Spectra™ (Software V ersion 3.
8 Pelco Manual C1488M-A (9/98) 3.1.2 Suspended Ceiling 1. Remov e the ceiling tile from the ceiling. 2. Locate the center point to drill a hole in the tile. 3. Drill a hole in the ceiling tile using a 3/32-inch drill bit. 4. Remov e the compass tool from the par ts bag (refer to Figure 2).
Pelco Manual C1488M-A (9/98) 9 Figure 4. Installing Back Bo x Figure 5. F astening Bac k Bo x HARD CEILING OR CEILING TILE T -RAIL CLIP FOR CEILING TILE HARD CEILING OR CEILING TILE T -RAIL CLIP FOR C.
10 Pelco Manual C1488M-A (9/98) Figure 6. Wiring Diagram f or Spectra™ (V er . 3.0) and Spectra II™ CONTROL (RS-422) 7 +5 to +24 VDC EXTERNAL RELA Y (WIRING EXAMPLE) CONTROL (RS-422) Figure 7.
Pelco Manual C1488M-A (9/98) 11 T able B. 24 V AC Wir ing Distances The follo wing are the recommended maximum distances f or 24 V AC with a 10- percent voltage drop . (T en percent is generally the maximum allo wable voltage drop for A C-po wered devices .
12 Pelco Manual C1488M-A (9/98) 3.3 BACK BOX INST ALLA TION 1. Suspended Ceiling Only (f or hard ceiling, go to step 2) – Install the ceiling tile with the bac k box. Attach a T -rail clip on each side of the ceiling tile as shown in Figure 5. The clips for the ceiling tile are supplied with the bac k bo x.
Pelco Manual C1488M-A (9/98) 13 3.4 BACK BOX CONNECTIONS Depending on the type of dome, ref er to either Figure 10 or 11 to attach the wiring to the interconnect circuit board inside the back bo x. Also refer to Figure 6 or 7 if necessary . 1. Earth Ground - Connect ear th ground to the middle connector on the po wer connector .
14 Pelco Manual C1488M-A (9/98) From contr oller T o 4-Wire terminal on circuit board RX- TX- RX+ TX+ TX- RX- TX+ RX+ NOTE: Connect only a low v olt- age de vice to the rela y output. Maximum current r ating of the re- la y contacts is two amperes. CAUTION: The maxi- mum output of A UX 2 is 150 mA.
Pelco Manual C1488M-A (9/98) 15 NOTE: If outdoors, apply Duct Seal inside the pipe por tion of the back bo x to pre vent moisture or cold air inside the mount from en- ter ing the unit and causing conden- sation on the dome. Duct Seal can be purchased through local elec- tr ical supply houses.
16 Pelco Manual C1488M-A (9/98) 5.0 TROUBLESHOOTING Symptom: LED does not light. If the red pow er LED on the door of the interconnect circuit board in the back bo x does not light: 1. T urn off power . 2. Open the door to the interconnect circuit board and check the fuse .
Pelco Manual C1488M-A (9/98) 17 6.0 SPECIFICA TIONS MECHANICAL Construction Back box: Aluminum Cable Entry In-Ceiling: .75" (1.91 cm) conduit fitting Pendant: Through 1.
18 Pelco Manual C1488M-A (9/98) Figure 12. SD5 Series Dimension Drawing 6.60 (16.76) 5.25 (13.34) 3.25 (8.26) 7.25 (18.13) 8.25 (20.96) 5.90 (14.99) In-Ceiling Dome Pendant Dome NO TE: V ALUES IN P ARENTHESES ARE CENTIMETERS , ALL OTHERS ARE INCHES . 5.
Pelco Manual C1488M-A (9/98) 19 NOTES.
20 Pelco Manual C1488M-A (9/98) 7.0 W ARRANTY AND RETURN INFORMA TION WARRANTY P elco will repair or replace, without charge , any merchandise prov ed def ective in material or workmanship for a period of one year after the date of shipment.
Een belangrijk punt na aankoop van elk apparaat Pelco BB5L (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco BB5L heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco BB5L vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco BB5L leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco BB5L krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco BB5L bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco BB5L kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco BB5L . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.