Gebruiksaanwijzing /service van het product C2410M-H van de fabrikant Pelco
Ga naar pagina of 17
ADDENDUM P elco W or ldwide Headquar t ers 3500 Pelco Way • Clovis , California 93612 USA USA & Canada • T el: 800/289-9100 • Fax: 800/28 9-9150 International • T el: 1-559/292-1 981 • Fax : 1-559/348-112 0 www .
® INST ALLA TION 110 Series Camclosure ® Integrated Camera System C2403M-C (10/05).
2 C2403M-C (10/05) Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C2403M-C (10/05) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
4 C2403M-C (10/05) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
C2403M-C (10/05) 5 Description The ICS110 Series Camclosure ® integrated camera system combines an environmental cover, back box, camera, lens, and lower dome into a small, high-security system that is quick and easy to install.
6 C2403M-C (10/05) Installation MOUNTING DIRECTLY TO SURFACE WIRING THROUGH BASE Follow the proceeding steps when feeding wire/cables through the base of the cover and back box: 1. Using the cover as a template, mark one of the large hole positions onto the mounting surface.
C2403M-C (10/05) 7 WIRING THROUGH SIDE CONDUIT Follow the proceeding steps when feeding wire/cables through the side conduit opening of the unit: 1. Attach the cover to the mounting surface (hardware not supplied). Use stainless steel hardware when installing the system outdoors.
8 C2403M-C (10/05) Install Camera 1. Some indoor installations do not require a heater . If the installation does not require a heater , remove the heater board from the camera assembly. T o remove the heater press on an end of the board. 2. 12 VDC operation only: The camera is set for 24 V AC operation at the factory.
C2403M-C (10/05) 9 5. Always make sure the tab on the camera bracket is pointing out of the enclosure (away from the ceiling or wall). Gently squeeze the bracket, place it against the groove inside back box, and gently release.
10 C2403M-C (10/05) Install Dome and T rim Ring 1. Domes with Liners (only) – 2. Align the screw holes in the trim ring with those in the Camclosure base. Position the viewing window over the lens of the camera. a. Loosen the three Phillip screws located in the dome.
C2403M-C (10/05) 11 AUTO IRIS LEVEL ADJUSTMENT If you have a varifocal lens or fi xed focal length lens with an auto iris, you can adjust the level setting to increase or decrease brightness.
12 C2403M-C (10/05) SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) i.
C2403M-C (10/05) 13 SWITCH SETTINGS FOR V ARIFOCAL LENS The high resolution camera with varifocal lens and auto iris is confi gured at the factory for optimal performance in lighting conditions where auto iris is required. It is also confi gured with the shutter speed set at 1/60 (NTSC) or 1/50 (PAL) and manual gain set at 6 dB.
14 C2403M-C (10/05) Specifications General Operating T emperature -50° to 122°F (-46° to 50°C) De-ices to 25°F (-4°C) Cable Entry 3/4-inch (1.91 cm) conduit fi tting and 3/4-inch (1.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
® United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.
Een belangrijk punt na aankoop van elk apparaat Pelco C2410M-H (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco C2410M-H heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco C2410M-H vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco C2410M-H leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco C2410M-H krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco C2410M-H bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco C2410M-H kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco C2410M-H . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.