BB14 Series Inter cept ® Back Box Installation/ Operation Manual C454M-C (1/98) Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-910.
2 Pelco Manual C454M-C (1/98) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 5 1.1 IMPORT ANT SAFEGUARDS AND WARNINGS ............................... 5 1.2 UNP ACKING INSTRUCTIONS .
Pelco Manual C454M-C (1/98) 3 REVISION HISTOR Y Manual # Date Comments C454M — Original version. C454M-A 6/95 Revised to incorporate B.O.M. quantity changes as per ECO# 94-445. Added 4-position terminal block information as per ECO# 94-042. Incorporated new “Front” labeling to B.
4 Pelco Manual C454M-C (1/98) (This page intentionally left blank.).
Pelco Manual C454M-C (1/98) 5 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed.
6 Pelco Manual C454M-C (1/98) 1.2 UNP ACKING INSTRUCTIONS Unpack and inspect all parts carefully . Be sure to save the shipping carton and any inserts.
Pelco Manual C454M-C (1/98) 7 2.0 DESCRIPTION The BB14 Series of back boxes is part of the IDS14 Intercept ® Series of domes. The IDS14 Series is an integral system that includes a back box (BB14), dome drive or fixed mount (DD14), and dome receiver/driver (DRD14).
8 Pelco Manual C454M-C (1/98) Indoor, Pendant BB14E100 Indoor, black, pendant-mount back box; smoked dome; hard- wire control. (CE, UL) BB14E101 Indoor, black, pendant-mount back box; clear dome; hard-wire control. (CE, UL) BB14E110 Indoor, black, pendant-mount back box; smoked dome; 120 VAC input.
Pelco Manual C454M-C (1/98) 9 3.0 INST ALLA TION 3.1 MOUNTING The Intercept ® Series of domes provide back box configurations for several applica- tions and environments (refer to Figures 12 and 13). Installation instructions for the applications listed below will appear in the following order: 1.
10 Pelco Manual C454M-C (1/98) 3.1.2 Hard Ceiling Mounting For installing the back box in a hard ceiling, an optional backup plate is provided for applications where additional reinforcement to the ceiling structure is needed. To mount the back box directly into a hard ceiling, perform the following steps.
Pelco Manual C454M-C (1/98) 11 3.1.3 Pendant Mounting The pendant back box is designed to be suspended from a suitable length of 1-1/2” pipe threaded at both ends. This pipe can be interfaced to the IWM Series or IDM4018 wall mounts or to the MRW A wall adapter mount or MRCA ceiling adapter mount.
12 Pelco Manual C454M-C (1/98) 3.2 WIRING INSTRUCTIONS How your back box will be wired depends on the type of unit you have: Units with an on-board receiver/driver Units without an on-board receiver/driver (hard-wire applications) Hardwire refers to installations using a remote receiver/driver or a true hardwire controller .
Pelco Manual C454M-C (1/98) 13 T able A. V ideo Coaxial Cable Requirements Cable T ype* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG1 1/U 1,500 ft (457 m) * Minimum cable requireme.
14 Pelco Manual C454M-C (1/98) Figure 3. 24 V AC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver).
Pelco Manual C454M-C (1/98) 15 Figure 4. 120 V AC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver).
16 Pelco Manual C454M-C (1/98) Figure 5. 230 V AC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver).
Pelco Manual C454M-C (1/98) 17 3.2.2 Hard-Wir e or Remote Receiver/Driver Refer to Figures 6 and 7 for wiring diagrams. Refer to T able A for the type of video coaxial cable to use. On models for suspended ceilings or hard ceilings, a plate is provided on the top of the back box with 1/2" and 3/4" conduit knockouts.
18 Pelco Manual C454M-C (1/98) Figure 6. Wiring Diagram, Hard-Wire Control with Heater NOTE: For fixed mount or dome drive with blower/heaters and without integral receiver/driver .
Pelco Manual C454M-C (1/98) 19 Figure 7. Wiring Diagram, Hard-Wire Control without Heater NOTE: For use in domes without integral receiver/driver or heaters and blower .
20 Pelco Manual C454M-C (1/98) 3.2.3 Heater/Blower Kit Field Installation The kits are shipped partially assembled, to complete assembly and to install the heater/blower kit perform the following steps: 1. Place the fan over the four (4) unused internally threaded standoffs located on the back plate (refer to Figure 1 1).
Pelco Manual C454M-C (1/98) 21 4.0 EXPLODED ASSEMBL Y DIAGRAMS Figure 8. Suspended Ceiling Back Box Exploded Assembly Diagram T able C. Suspended Ceiling Back Box Exploded Assembly Parts List Item Qua.
22 Pelco Manual C454M-C (1/98) Item Quantity Description Part Number 11 T rim ring, white SB262ASSY 21 Back box 8141202W A 31 Plate, gland 8004130COMP 44 Receiver ball stud PT180410001 1 Switch, on/of.
Pelco Manual C454M-C (1/98) 23 Figure 10. Pendant Back Box Exploded Assembly Diagram T able E. Pendant Back Box Exploded Assembly Part List Item Quantity Description Part Number 11 Bezel, black 814419.
24 Pelco Manual C454M-C (1/98) Figure 1 1. Back Plate Exploded Assembly Diagram.
Pelco Manual C454M-C (1/98) 25 T able F . Back Plate Exploded Assembly Parts List (Figure 1 1) Item Quantity Description Part Number 12 Latch backup plate 8004244COMP 22 Latch 8004105COMP 32 Latch bracket 8004143COMP 41 T ransformer (120 V AC model only) TRF21243.
26 Pelco Manual C454M-C (1/98) 5.0 SPECIFICA TIONS ELECTRICAL Enclosure Back Box Input Voltage: 24 VAC or 120 VAC Power Requirements Receiver/Driver: 48 vA for 24 VAC and 120 VAC dome drives Blower continuous duty: One (1) at 30 cfm, 1.92 watts, 24 VDC One (1) at 33 cfm, 6.
Pelco Manual C454M-C (1/98) 27 Figure 12. Suspended/Hard Ceiling Dimension Drawings Figure 13. Pendant-Mount Dimension Drawing NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES NOTE: .
28 Pelco Manual C454M-C (1/98) 6.0 WARRANTY AND RETURN INFORMA TION This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE).
Een belangrijk punt na aankoop van elk apparaat Pelco C454M-C (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco C454M-C heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco C454M-C vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco C454M-C leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco C454M-C krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco C454M-C bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco C454M-C kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco C454M-C . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.