INHOUDp.31,0 ALGEMEENp.41.1 BELANGRIJKE WAARBORGEN EN WAARSCHUWINGENp.42.0 BESCHRIJVINGp.52.1 MODELLENp.53.0 INFORMATIE VOOR DE INSTALLATIEp.63.1 TOEGANG TOT VOORAANZICHT EN DIPSCHAKELAARp.63.1.1 DIP-schakelaarsp.63.1.2 LED'sp.63.2 REAR VIEWp.73.2.1 REL-contactpaarverbindingenp.83.2.2 Externe bedradingsconsideratiesp.93.2.3 Communicatieconnectorenp.93.2.3.1 DB-9 Connectorp.93.2.3.2 RJ-45 Datakabelsp.103.2.4 Stroomaansluitingenp.113.3 OPZETp.123.3.1 Voorafgaande discussiep.123.3.2 DIP-schakelaarinstellingenp.143.3.3 Software-overwegingenp.174.0 INSTALLATIEp.184.1 DIRECTE MONTAGE VAN DE RACK-MOUNT CONNECTORp.184.2 VERRICHTING OP AFSTANDp.184.3 MADELIEFJESKETENp.195.0 BEWERKINGp.205.1 OPERATIONEEL OVERZICHTp.205.2 DE CM9760-REL VAN HET CM97 60-KBD BEDIENENp.205.2.1 Informatie Terugwinningp.205.2.2 Operatie toetsenbordp.226.0 SPECIFICATIESp.247.0 GARANTIE- EN RETOURINFORMATIEp.25LIJST VAN ILLUSTRATIESp.31 Vooraanzicht met paneel verwijderenp.62 Achteraanzicht van de CM9760-RELp.73 Relaisinterface-contactconfiguratiep.84 externe relais bedradingp.95 RJ-45 uitklapbare pinnenp.106 RJ-45 Kabeltypenp.107 Power Input Fuse Vervangingp.118 Relatie van de frameadresruimte en de Relay Interface Unitp.129 Relatie van frameadresruimte met betrekking tot het startenp.1310 DIP-switchfunctiesp.1411 Het instellen van het GPI-definieerbestand voor REL-operatiep.1712 Het COMMS-bestand instellen voor REL-bewerkingp.1713-eenheidsafmetingen en Rack-Mount installatiep.18Configuratie van de Relay Unit Daisy-Chainp.1915 Fysieke vertegenwoordiging van figuur 16p.2116 Controlling REL-uitvoercontacten van de CM9760-KBDp.23LIJST VAN TABELLENp.3Een Frame Adres, GPI Range Associatiep.15
Page 1 of the Pelco C543M-A user manual — Addendum nr.: C1577M-A
Pagina 1 · klik om te vergroten
Pagina 1

A D D E N D U M

Addendum nr.: C1577M-A

Datum: 4 augustus 2004

Beïnvloedde handleidingen: CM9760 Series Manuals C538M-A, C539M-A, C540M-B, C541M-C, C542M-B, C543M-A, C544M, C549M-A, C572M, C573M-D, C578M, C579M, C1501M, C1503M, C1510M-QS, C1510M-A, C1520M-B, C1528M-D, C1940M, C1941M, C1942M, en C1943M

Handmatig bijwerken: De CM9760-CC1 is vervangen door de CM9700-CC1, en de CM 9760-MGR manage- ment software is vervangen met de CM9700-Mgr managementsoftware.

Houd bij het verwijzen naar de instructies in deze handleidingen rekening met:

  • De CM9700-CC1 bevat de nieuwste CC1-software (versie 9.01 of hoger), en is geprogrammeerd met nieuwe CM970-MGR management software.
  • Ondanks het verschil in modelnummers functioneert de CM9700-CC1 hetzelfde als de CM 9760-CC1, en is de meeste informatie in deze handleidingen van toepassing op versie 9.01 (of hoger) CPU.
  • U kunt de CM9700-CC1 toevoegen aan een bestaand CM9760 systeem als u bestaande CM97 60-CC1-eenheden met huidige software upgrade (versieniveau 9.01 of hoger).

Software versie 9.01 vereist een minimum van 16 MB aan RAM in de CPU. Indien nodig kunt u het RAM-geheugen upgraden in oudere CM9760-CC1-eenheden met behulp van de softwareupgradekit die geschikt is voor uw CPU.

  • Gebruik de CM9760-MGR instructies in deze handleidingen niet. Raadpleeg de CM9700-MGR Started Software Guide, hulp op het scherm of Online Help voor instructies.
  • Pelco World Headquarters
  • 3500 Pelco Way, Clovis, California 93612-5699 Verenigde Staten
  • <a href="http://www.pelco.com" rel="nofollow noopener" target=" blanc">www.spelco.nl</a> USA & Canada: Tel: 800/289/9100
  • Fax: 800/289/9150 International: Tel.: 1-559/292-1981
  • Fax: 1-559/348-1120

®

Page 2 of the Pelco C543M-A user manual
Pagina 2 · klik om te vergroten
Pagina 2
Pelco C543M-A diagram (page 2)
Afb. 1
  • Pelco World Headquarters
  • 3500 Pelco Way, Clovis, CA 93612-5699 Verenigde Staten
  • <a href="http://www.pelco.com" rel="nofollow noopener" target=" blanc">www.plco.nl</a>
  • USA & Canada: Tel: 800/289-9100
  • Fax: 800/289/9150 International: Tel.: 1-559/292-1981
  • Fax: 1-559/348-1120
Page 3 of the Pelco C543M-A user manual — LIJST VAN TABELLEN
Pagina 3 · klik om te vergroten
Pagina 3

INHOUD

Sectiepagina 1.0 ALGEMENE 3 1.1 BELANGRIJKE BESCHERMINGSZORGEN EN WAARSCHUWINGEN 3 2.0 BESCHRIJVING 4 2.1 MODELLEN 4 3.0 VOORINSTALERINGINFORMATIE 5 3.1 TOEGANG TOT DE VOORUITZICHTEN EN DIP-WISSELING 5 3.1.1 DIP Schakelaars 5 3.1.2 LED's 5 3.2 RECREAR VIEW 6 3.2.1 REL Contact Pairaansluitingen 7 3.2.2 Externe relais Wierende Bedrading Overwegingen 8 3.2.3 Communicatieconnectoren 8.3.2.3.1 DB-9 Connector 8 3.2.3.2 RJ-45 Datakabels 9 3.2.4 Stroomverbindingen 10 3.3 SETUP 11 3.3.1 Voorlopige discussie 11 3.3.2 DIP switch Instellingen 13 3.3.3 Software-overwegingen 16 4.0 INSTALLATIE 17 4.1 RECHTSTREEKSE RACKMOUNT HOOK-UP 17 4.2 ReEMOTE OPWERKING 17 4.3 DAISY-CHAINE 18 5.0 EXPLOITATIE 19 5.2 IN VERBAND MET DE UIT HET CM9760-KBD 19.2.2012 RETREGALE INFORMATIE RetrievaL19.5.7 Keyboardoperatie 21.6.2011 23.7.2 WARRANTY EN HERHAAL INFORMATIE 24 0.0 VERLEIDINGEN

LIJST VAN ILLUSTRATIES

Figuurpagina 1 front View with Panel Removal 5 2 rear View of the CM9760-REL 6 3 relaisinterface Contactconfiguratie 7 4 externe relay bedrading 8 5 RJ-45 pinnen 9 6 RJ-4 kabeltypes 9 7 stroomingang Fuse Vervanging 10 8 relatie van het Frame Adresruimte en de Relais Interface Unit... 11 9 Relatie van de frame-adresruimte met betrekking tot het beginadres en de Relay Interface Units 12 10 DIP switch functies 13 11 Het instellen van het GPI Definieer bestand voor REL operatie 16 12 Het configureren van het COMMS bestand voor REL werking 16 13 Eenheid Afmetingen en Rack-Mount installatie 17 14 Relay unit Daisy-Chain configuratie 18 15 Fysische weergave van figuur 16 20 16 Controleren REL uitvoercontacten vanuit CM9760-KBD 22

LIJST VAN TABELLEN

Tabelpagina Een Frame Adres, GPI Range Association 14

Page 4 of the Pelco C543M-A user manual — Gelieve uzelf grondig vertrouwd te maken met de informatie
Pagina 4 · klik om te vergroten
Pagina 4

1,0 ALGEMEEN

1.1 BELANGRIJKE WAARBORGEN EN WAARSCHUWINGEN

Vóór de installatie en het gebruik van dit product dienen volgende WAARSCHUWINGEN te worden waargenomen.

1. Installatie en onderhoud mogen alleen worden uitgevoerd door gekwalificeerd personeel van de dienst, dat aan alle lokale codes voldoet.
2. Tenzij de eenheid specifiek is gemarkeerd als NEMA type 3, 3R, 3S, 4, 4X ,6 of 6P behuizing, is deze ontworpen voor gebruik binnenshuis en mag hij niet worden geïnstalleerd wanneer het wordt blootgesteld aan regen en vocht.
3. Gebruik alleen de door Pelco aanbevolen vervangende onderdelen.
4. Na vervanging/reparatie van deze eenheid zijn elektrische onderdelen niet aangesloten op lijncircuits.

Het product en/of de handleiding mogen voorzien zijn van:

Dit symbool geeft aan dat er binnen deze eenheid gevaarlijke spanning aanwezig is die een gevaar voor elektrische schokken vormt.

Dit symbool geeft aan dat er belangrijke bedienings- en onderhoudsinstructies in de literatuur bij deze eenheid.

VOORZICHTIGHEID:

RISICO VAN ELEKTRISCHE SCHOK.

DO NOT OPEN.

VOORZICHTIGHEID: HET RISICO VAN ELEKTRISCHE SCHOKKEN TE VERMINDEREN;

DE DEKKING NIET VERWIJDEREN. GEEN GEBRUIKSBARE ONDERDELEN BINNEN. REFER SERVICE

OP GEKWALIFICEERD PERSONEEL.

Gelieve uzelf grondig vertrouwd te maken met de informatie

in deze handleiding voorafgaand aan installatie en werking.

Page 5 of the Pelco C543M-A user manual — 2.1 MODELLEN
Pagina 5 · klik om te vergroten
Pagina 5

2.0 BESCHRIJVING

De CM9760-REL Relay Interface Unit is een optioneel accessoire van het System 9760®. De relaisinterface-eenheid zorgt voor een droge contactschakelaar om de randapparatuur direct of automatisch te controleren. De unit verbindt elke RS-422 COMM-poort aan de achterzijde van het CM9760-CC1.

Enkele van de belangrijkste kenmerken van het CM9760-REL zijn:

  • Elke eenheid biedt tot 64 enkelpolige, enkelvoudige-duw (SPST) contactuitgangen voor het bedienen van verschillende randapparatuur.
  • Relay-uitvoercontacten kunnen worden geconfigureerd voor N/O (factory default) of N/C werking.
  • Met een handige .memory
  • Meerdere eenheden kunnen worden gecascadeerd om het aantal relaiscontactuitgangen te verlengen die vanuit één poort op de CC1 bediend zijn (meer dan 5.000 relaise uitgangen kunnen geconfigureerd worden).
  • De relais kan op afstand worden geplaatst tot 4.000 voet (1.219,2 meter) van de controller (RS-422 werking).
  • De unit wordt aangedreven door een automatische voeding.
  • De unit is een uniek, één rack-unit chassis (1.75 inch of 4.45 cm) geschikt voor meerdere soorten montages.

2.1 MODELLEN

CM9760-REL Enkel relaiseenheid die tot 64 contactuitgangen per eenheid kan regelen. CE)

Page 6 of the Pelco C543M-A user manual — 3.1.2 LED's
Pagina 6 · klik om te vergroten
Pagina 6

3.0 INFORMATIE VOOR DE INSTALLATIE

3.1 TOEGANG TOT VOORAANZICHT EN DIPSCHAKELAAR

Figuur 1 illustreert een vooraanzicht van de eenheid met het frontpaneel verwijderd. Vermogen (groen) en Data-leds (rood) bezetten tegenover elkaar liggende uiteinden van de unit paneel. Zoals geïllustreerd, de verwijdering van vijf platte-kop Phillips schroeven die het frontpaneel op zijn plaats houden toegang tot de eenheden drie DIP switches en de reset switch. Alle andere schakelaars en aansluitingen bevinden zich aan de achterkant van het toestel.

3.1.1 DIP-schakelaars

De relais interface unit heeft drie 10-positie DIP schakelaars die de communicatie parameters voor het apparaat configureren en ook de parameters instellen voor contact met relaise uitgang. DIP-switchfuncties worden besproken in paragraaf 3.3.2, instellingen voor dip switch.

3.1.2 LED's

De groene POWER LED aan de linkerkant van het frontpaneel van de unit komt op vermogen.

De rode DATA LED aan de rechterkant van het frontpaneel knippert voortdurend in en uit met een regelmatig tempo (ongeveer 1/2 seconden interval) totdat het eerste geldige commando wordt ontvangen. De LED zal niet meer knipperen totdat er een ander geldig commando is ontvangen. In cascaded configuraties geeft elke relaiseenheid alleen de ontvangen gegevens aan wanneer deze het overeenkomstige adres van de eenheid hebben. Met andere woorden, LED-activiteit is adresspecifiek.

Als de stroom wordt gefietst, als een DIP-schakelaar geschakeld is of wanneer er een reset van het frontpaneel optreedt zal de LED opnieuw met tussenpozen knipperen totdat het eerste geldige commando ontvangen is.

Pelco C543M-A — 3.1.2 LED's diagram (page 6)
Afb. 2 · 3.1.2 LED's

Figuur 1. Vooraanzicht met paneel verwijderen

Page 7 of the Pelco C543M-A user manual — 3.2 REAR VIEW
Pagina 7 · klik om te vergroten
Pagina 7

3.2 REAR VIEW

De achterkant van de eenheid wordt geïllustreerd in figuur 2. Van links naar rechts zijn de volgende:

1. Vier blokken bestaande uit 16 contactparen, elk met paarpluggen voor de bevestiging van randapparatuur. (Alleen het blok voor de eerste 16 contactparen wordt getoond met paarpluggen.)
2. RS-422 ingangs-/outputcommunicatieconnectoren (RJ-45 type).
3. Eén DB-9 connector (alleen voor industrieel gebruik).
4. De gegroepeerde input power functies, bestaande uit ingangsvoeding terminals, een zekering en een AAN/UIT schakelaar.
Pelco C543M-A — 3.2 REAR VIEW diagram (page 7)
Afb. 3

Figuur 2. Achteraanzicht van de CM9760-REL

Page 8 of the Pelco C543M-A user manual — 3.2.1 REL-contactpaarverbindingen
Pagina 8 · klik om te vergroten
Pagina 8

3.2.1 REL-contactpaarverbindingen

Fysiek bestaat elk relaisblok uit 16 relaisoncontacten en twee paarpluggen. Aangezien een relaiscontact twee terminalposities vereist, biedt elke stekker 8 contacten via 16 schroefterminals.

Om de schroef-eindpennummers voor een bepaald contact te bepalen, zie figuur 3.

Pelco C543M-A — 3.2.1 REL-contactpaarverbindingen diagram (page 8)
Afb. 4 · 3.2.1 REL-contactpaarverbindingen

Figuur 3. Interface-configuratie relais

Page 9 of the Pelco C543M-A user manual — 3.2.3.1 DB-9 Connector
Pagina 9 · klik om te vergroten
Pagina 9

3.2.2 Externe bedradingsconsideraties

Onderdelen van externe relaisbedrading worden geïllustreerd in figuur 4.

3.2.3 Communicatieconnectoren

De communicatie van en naar de eenheid wordt verzorgd via twee RJ-45 havens aan de achterzijde van het CM9760-REL. De havens worden fysiek aangeduid als IN en OUT-havens.

De RJ-45 IN aansluiting maakt het mogelijk de REL unit aan te sluiten op een geschikte Sercom poort achteraan een CM9760-CC1-controller. Deze poort is fabrieksset voor RS-422 communicatie.

De RJ-45 OUT vrouwelijke stekker aan de achterzijde van het apparaat is altijd geconfigureerd voor RS-422 en wordt gebruikt om volgende REL eenheden te cascaden.

De RJ-45 aansluitingspen is afgebeeld in figuur 5.

3.2.3.1 DB-9 Connector

De achterpaneel DB-9 connector (alleen voor industrieel gebruik).

Pelco C543M-A — 3.2.3.1 DB-9 Connector diagram (page 9)
Afb. 5 · 3.2.3.1 DB-9 Connector

32°-122°F (0°-50°C)

Figuur 4. Externe relaisbedrading

Page 10 of the Pelco C543M-A user manual — 3.2.3.2 RJ-45 Datakabels
Pagina 10 · klik om te vergroten
Pagina 10

3.2.3.2 RJ-45 Datakabels

Omdat beide RJ-45 aansluitingen dezelfde bedradingspenuittreksels hebben, zijn ze voor hetzelfde gebruik nodig. Met andere woorden, de IN-connector vereist een .Flipped Een .Flipped Zie figuur 6.

Pelco C543M-A — 3.2.3.2 RJ-45 Datakabels diagram (page 10)
Afb. 6 · 3.2.3.2 RJ-45 Datakabels

Figuur 5. RJ-45 Pinnen

Pelco C543M-A — 3.2.3.2 RJ-45 Datakabels diagram (page 10)
Afb. 7 · 3.2.3.2 RJ-45 Datakabels

Figuur 6. RJ-45 Kabeltypen

Page 11 of the Pelco C543M-A user manual — 3.2.4 Stroomaansluitingen
Pagina 11 · klik om te vergroten
Pagina 11

3.2.4 Stroomaansluitingen

De CM9760-REL maakt gebruik van een automatisch uit te breiden interne transformator circuit dat het mogelijk maakt ingangsvermogen variëren van 100-240 VAC, 50/60Hz. In verband met het ingangsvermogen is de stroomschakelaar AAN/UIT en de instroom zekering verbonden. De zekering wordt gemakkelijk gewijzigd zoals in figuur 7 is aangegeven.

Pelco C543M-A — 3.2.4 Stroomaansluitingen diagram (page 11)
Afb. 8 · 3.2.4 Stroomaansluitingen

Figuur 7. Vervanging van stroomingangslus

Page 12 of the Pelco C543M-A user manual — DE FUNCTIE RELAISINTERFACEGEHEUGEN
Pagina 12 · klik om te vergroten
Pagina 12

3.3 OPZET

3.3.1 Voorafgaande discussie

FRAMEADRESSEN

De IRC, VCRC en de CM9760-REL Relay Interface Unit gebruiken allemaal software GPI's om controle van externe apparaten te activeren.

Het aantal GPI's dat elk hardwareapparaat nodig heeft, varieert. Het aantal GPI's (Algemeen Doel Interface) dat door de REL wordt vereist, is acht.

De adresinstelling die in de DIP-schakelaars wordt ingevoerd, is echter gebaseerd op wat een frameadres heet.

Er is een directe numerieke relatie tussen GPI's en het adresseren van de beelden, wat als volgt luidt:

Het gebruik van 32 GPI's spaneert een frame-adres, met betrekking tot het niet gebruikte DE VICE-TYPE (andere apparaten dan REL-eenheden gebruiken ook de controle over GPI).

Daarom beslaat een enkele REL, die acht GPI's gebruikt, slechts 1/4 van de framead-jurk (zie figuur 8).

Pelco C543M-A — FRAMEADRESSEN diagram (page 12)
Afb. 9

Dit betekent dat vier relaiseenheden in één frame adresruimte passen. Om REL-eenheden binnen dit frame adresruimte uniek te maken en aan te sluiten, worden twee extra bits van het adres (subframe bit) gebruikt (zie figuur 10).

Het frameadres dat in de DIP-schakelaar voor het REL (of een ander apparaat) wordt ingevoerd, dient als startpunt voor de ruimte waar het frames naartoe moet. Zodra een startframe adres is ingevoerd, kan de REL worden beschouwd als het toewijzen van zelf de volgende acht GPI's of de gelijkwaardige 1/4 frameadresruimte die nodig is om te werken. De REL is natuurlijk uniek in die zin dat wanneer je een groep van REL-eenheden hebt, totaal vier of minder, ze allemaal meer dan waarschijnlijk het SAME FRAME ADRES zullen delen en alleen verschillen in hun SUBFRAME adres bit instellingen.

AANVULLENDE OPMERKINGEN OVER FRAMEADRESSEN EN GPIS

Een frame adres is equivalent aan het gebruik van 32 GPI's. Met een totaal van slechts 700 GPI's beschikbaar, zijn er alleen 700/32 of 21.8 (afgerond tot 22) frame adressen nodig. Frameadressering begint bij De indeling van alle 22 frameadressen en bijbehorende GPI-bereiken is te vinden in tabel A.

Figuur 8. Relatie van het frame

Adresruimte en de Relay Interface Unit

DE FUNCTIE RELAISINTERFACEGEHEUGEN

SW3 DIP switch instellingen (SW3-3 door SW3-6) regelen wat kan worden gedacht als de contact

Normaal gesproken zou men verwachten dat wanneer de stroom wordt gecycled (via een power-office of reset van het frontpaneel) de contacten met het relais zouden terugkeren naar hun standaardinstellingen, die voor REL worden bepaald door normaal open en normale gesloten instellingen (N/O, N/C), ingevoerd in DIP switch 2 (SW2-7 tot SW2-10).

De extra DIP-schakelaarinstellingen voor de geheugenfunctie laten u toe om het standaard instellen in het event power wordt gecycled. Met een schakelaarinstelling van Voor groepen die niet zijn ingeschakeld, zullen de contacten zich tot hun standaardwaarden (per DIP-schakelaar 2 instellingen) uitstrekken als het vermogen is gecycled (zie figuur 10).

Page 13 of the Pelco C543M-A user manual — WERKVOORSCHRIFTEN
Pagina 13 · klik om te vergroten
Pagina 13

Bij het instellen van frameadressen op de voorpaneelschakelaars voor een groep met daisy-ketende REL eenheden, houd er rekening mee dat u enkele werkregels moet volgen:

WERKVOORSCHRIFTEN

1. Begin met frameadres 0, dat wordt geassocieerd met fysieke GPI 1, en werk achtereenvolgens vooruit totdat alle relais interface eenheden zijn verwerkt. Zorg ervoor dat de frameadresruimte aan elkaar is verbonden (zie VOORBEELD EEN en TWEE van figuur 9).

Figuur 9 doet illustreert dat frame adresinstellingen: (1) Moet uniek zijn voor elke eenheid. (2) Moet de werkregels volgen

2. De fysieke volgorde waarin relaiseenheden zijn aangesloten is irrelevant. In een cascadede situatie moeten echter overgebleven REL combinaties met minder dan één frameadresruimte aan het einde van de toegewezen adresruimte worden geplaatst.

vermeld.

3. Overlap de frameadresruimtes niet (zie VOORBEELD VIER in figuur 9).
4. Laat geen open frameadresruimtes in de indeling (zie VOORBEELD DRIE in figuur 9).

Voor verklarende doeleinden wordt de opstelling in figuur 9 opnieuw gebruikt in andere delen van het handboek om verschillende aspecten van REL configuratie en setup te illustreren.

Pelco C543M-A — WERKVOORSCHRIFTEN diagram (page 13)
Afb. 10

ELK VAK GEEFT DE FRAME ADRESRUIMTE WEER (ACHT GPIS) DIE DOOR ÉÉN REL-EENHEID WORDT GEBRUIKT.

3 2 1 0 3 2 1 0 3 2 1 0 3 2 1 0 3 2 1 0 3 2 1 0

EENHEIDSREFERENTIEÉÉN FRAME ADRESRUIMTE OVERSPANT 32 GPIS

Figuur 9. Relatie van frameadresruimte met betrekking tot

Startadres en de Relay Interface Units

Page 14 of the Pelco C543M-A user manual — 3.3.2 DIP-schakelaarinstellingen
Pagina 14 · klik om te vergroten
Pagina 14

3.3.2 DIP-schakelaarinstellingen

DIP-schakelaarinstellingen worden geïllustreerd en besproken in figuur 10.

Pelco C543M-A — 3.3.2 DIP-schakelaarinstellingen diagram (page 14)
Afb. 11 · 3.3.2 DIP-schakelaarinstellingen

Figuur 10. DIP-schakelaarfuncties

Page 15 of the Pelco C543M-A user manual — Een Frame Adres, GPI Range Associatie
Pagina 15 · klik om te vergroten
Pagina 15

Tafel A. Frameadres, GPI-bereikassociatie

Daisy-Chained Frame Subframe Gecombineerde geassocieerde GPI Range Relay Units Adressen Adressen Frame/Subframe Acht Vereiste GPI # . Geassocieerde SW2 SW3-adressen met een Frame / subframe Address 1 2 3 4 5 6 1 2 FA/SFA 1 2 4 5 7 8

1 00 1 2 3 4 5 6 7 8

2 0 1 0 01 9 10 11 12 13 14 15 16

3 0 1 02 17 18 19 20 21 22 23 24

4 0 1 1 03 25 26 27 28 29 30 31 32

5 1 0 10 33 34 35 36 37 38 39 40

6 1 0 1 0 11 41 42 43 44 45 46 47 48

7 1 0 1 12 49 50 51 52 53 54 55 56

8 1 0 1 1 13 57 58 59 60 61 62 63 64

9 0 1 0 20 65 66 67 68 69 70 71 72

10 0 1 0 1 0 21 73 74 75 76 77 78 79 80

11 0 1 0 1 22 81 82 83 84 85 86 87 88

12 0 1 0 1 1 23 89 90 91 92 93 94 95 96

13 1 1 0 30 97 98 99 100 101 102 103 104

14 1 1 0 1 0 31 105 106 107 108 109 110 111 112

15 1 1 0 1 32 113 114 115 116 117 118 119 120

16 1 1 0 1 1 33 121 122 123 124 125 126 127 128

17 0 0 1 0 40 129 130 131 132 133 134 135 136

18 0 0 1 0 0 0 1 0 41 137 138 139 140 141 142 143 144

19 0 0 1 0 1 42 145 146 147 148 149 150 151 152

20 0 0 1 0 0 0 1 1 43 153 154 155 156 157 158 159 160

21 1 0 1 0 50 161 162 163 164 165 166 167 168

22 1 0 1 0 0 0 1 0 51 169 170 171 172 173 174 175 176

23 1 0 1 0 1 52 177 178 179 180 181 182 183 184

24 1 0 1 0 0 0 1 1 53 185 186 187 188 189 190 191 192

25 0 1 1 0 60 193 194 195 196 197 198 199 200

26 0 1 1 0 0 0 1 0 61 201 202 203 204 205 206 207 208

27 0 1 1 0 1 62 209 210 211 212 213 214 215 216

28 0 1 1 0 0 0 1 1 63 217 218 219 220 221 222 223 224

29 1 1 1 0 70 225 226 227 228 229 230 231 232

30 1 1 1 0 0 0 1 0 71 233 234 235 236 237 238 239 240

31 0 1 72 241 242 243 244 245 246 247 248

32 1 1 1 0 0 0 1 1 73 249 250 251 252 253 254 255 256

33 0 0 0 1 0 80 257 258 259 260 261 262 263 264

34 0 0 0 1 0 0 1 0 81 265 266 267 268 269 270 271 272

35 0 0 0 1 0 0 0 1 82 273 274 275 276 277 278 279 280

36 0 0 0 1 0 0 1 1 83 281 282 283 284 285 286 287 288

37 1 0 0 1 0 90 289 290 291 292 293 294 295 296

38 1 0 0 1 0 0 1 0 91 297 298 299 300 301 302 303 304

39 1 0 0 1 0 0 0 1 92 305 306 307 308 309 310 311 312

40 1 0 0 1 0 0 1 1 93 313 314 315 316 317 318 319 320

41 0 1 0 1 0 100 321 322 323 324 325 326 327 328

42 0 1 0 1 0 0 1 0 101 329 330 331 332 333 334 335 336

43 0 1 0 1 0 0 0 1 102 337 338 339 340 341 342 343 344

44 0 1 0 1 0 0 1 1 103 345 346 347 348 349 350 351 352

(Vervolg op de volgende bladzijde)

Page 16 of the Pelco C543M-A user manual — Een Frame Adres, GPI Range Associatie
Pagina 16 · klik om te vergroten
Pagina 16

Tafel A. Frameadres, GPI Range Association (Vervolg)

Daisy-Chained Frame Subframe Gecombineerde geassocieerde GPI Range Relay Units Adressen Adressen Frame/Subframe Acht Vereiste GPI # . Geassocieerde SW2 SW3-adressen met een Frame / subframe Address 1 2 3 4 5 6 1 2 FA/SFA 1 2 4 5 7 8

45 1 1 0 1 0 110 353 354 355 356 357 358 359 360

46 1 1 0 1 0 0 1 0 111 361 362 363 364 365 366 367 368

47 1 1 0 1 0 0 0 1 112 369 370 371 372 373 374 375 376

48 1 1 0 1 0 0 1 1 113 377 378 379 380 381 382 383 384

49 0 0 1 1 0 120 385 386 387 388 389 390 391 392

50 0 0 1 1 0 0 1 0 121 393 394 395 396 397 398 399 400

51 0 0 1 1 0 0 0 1 122 401 402 403 404 405 406 407 408

52 0 0 1 1 0 0 1 1 123 409 410 411 412 413 414 415 416

53 1 0 1 1 0 130 417 418 419 420 421 422 423 424

54 1 0 1 1 0 0 1 0 131 425 426 427 428 429 430 431 432

55 1 0 1 1 0 0 0 1 132 433 434 435 436 437 438 439 440

56 1 0 1 1 0 0 1 1 133 441 442 443 444 445 446 447 448

57 0 1 1 1 0 140 449 450 451 452 453 454 455 456

58 0 1 1 1 0 0 1 0 141 457 458 459 460 461 462 463 464

59 0 1 1 1 0 0 0 1 142 465 466 467 468 469 470 471 472

60 0 1 1 1 0 0 1 1 143 473 474 475 476 477 478 479 480

61 0 150 481 482 483 484 485 486 487 488

62 1 0 0 1 0 151 489 490 491 492 493 494 495 496

63 1 0 0 0 1 152 497 498 499 500 501 502 503 504

64 1 0 0 1 1 153 505 506 507 508 509 510 511 512

65 0 1 0 0 0 160 513 514 515 516 517 518 519 520

66 0 1 0 1 0 161 521 522 523 524 525 526 527 528

67 0 1 0 0 1 162 529 530 531 532 533 534 535 536

68 0 1 0 1 1 163 537 538 539 540 541 542 543 544

69 1 0 0 0 1 0 0 0 170 545 546 547 548 549 550 551 552

70 1 0 0 0 1 0 1 0 171 553 554 555 556 557 558 559 560

71 1 0 0 0 1 0 0 1 172 561 562 563 564 565 566 567 568

72 1 0 0 0 1 0 1 1 173 569 570 571 572 573 574 575 576

73 0 1 0 0 1 0 0 0 180 577 578 579 580 581 582 583 584

74 0 1 0 0 1 0 1 0 181 585 586 587 588 589 590 591 592

75 0 1 0 0 1 0 0 1 182 593 594 595 596 597 598 599 600

76 0 1 0 0 1 0 1 1 183 601 602 603 604 605 606 607 608

77 1 1 0 0 1 0 0 0 190 609 610 611 612 613 614 615 616

78 1 1 0 0 1 0 1 0 191 617 618 619 620 621 622 623 624

79 1 1 0 0 1 0 0 1 192 625 626 627 628 629 630 631 632

80 1 1 0 0 1 0 1 1 193 633 634 635 636 637 638 639 640

81 0 0 1 0 1 0 0 0 200 641 642 643 644 645 646 647 648

82 0 0 1 0 1 0 1 0 201 649 650 651 652 653 654 655 656

83 0 0 1 0 1 0 0 1 202 657 658 659 660 661 662 663 664

84 0 0 1 0 1 0 1 1 203 665 666 667 668 669 670 671 672

85 1 0 1 0 1 0 0 0 210 673 674 675 676 677 678 679 680

86 1 0 1 0 1 0 1 0 211 681 682 683 684 685 686 687 688

87 1 0 1 0 1 0 0 1 212 689 690 691 692 693 694 695 696

88 1 0 1 0 1 0 1 1 213 697 698 699 700 701 702 703 704

Page 17 of the Pelco C543M-A user manual — R1, R2...R8 GECONFIGUREERD ALS
Pagina 17 · klik om te vergroten
Pagina 17

3.3.3 Software-overwegingen

Toegang tot de werking van specifieke apparaten die zijn aangesloten op REL-eenheden met behulp van toetsenborden of macrobewerkingen hangt af van het GPI en de specifieke GPI bereik elke REL eenheid wordt toegewezen. Om dit mogelijk te maken, moet de software GPI Definieer Bestand worden geconfigureerd met behulp van het MGR programma. Wat volgt is een korte inleiding tot de configuratie van GPI en COMM setup bestanden die moeten worden geprogrammeerd voor succesvolle REL werking. Deze introductie kan niet betrekking hebben op andere items die nodig zijn voor uw specifieke systeem werking. Raadpleeg uw MGR handleiding en bijbehorende software voor andere specifieke of gedetailleerde informatie.

De macro moet uw werkelijke configuratie weerspiegelen; als u de instellingen wijzigt, dient u de macro dienovereenkomstig aan te passen. Als bijvoorbeeld een macro werd geschreven om drie REL's in een madelief-ketenconfiguratie te controleren en één van de RL's vervolgens verwijderd was, dan zou elke eerder geschreven macro die deze drie RL ' s bevatte herschreven moeten worden om opnieuw met die verandering over te gaan. Ook de instelling van het frameadres van een REL is in wezen hetzelfde als die welke fysiek uit de configuratie wordt verwijderd.

Op een PC en beeldscherm met het 9760 MGR setup programma, start u het programma en toegang tot de GPI File (GPI bestand). Zie figuur 11.

Elke GPI kan tot acht relais bedienen; we moeten daarom 8 GPI's configureren om de 64 relaissen op één REL-eenheid te besturen.

1. Programmaeer de logische GPI-nummers voor alle fysieke GPI nummers die zullen worden gebruikt. In de meeste gevallen is het raadzaam om een logisch getal te programmeren dat gelijk is aan het bestaande fysieke GPI-nummer.
2. Voor elke GPI die hiermee is verbonden, worden individuele relais als momentary of locking geconfigureerd, afhankelijk van de toepassing.

R1 R2 R3 R8 Latching . . .

Als het vakje is aangevinkt, wordt de sluiting vergrendeld; anders gaat het om mometarie (zie figuur 11).

3. Definieer de toegang tot operator, sla het GPI-bestand op, keer terug naar het hoofdmenuscherm van MGR en druk op het tabblad om het COMMS bestand (.SCP file) te brengen. Zie figuur 12.

4. In het COMMs-bestand, een apparaatnummer (PIN) van 17 toekennen aan de poort op CC1 die zal worden gebruikt voor communicatie met de REL. Stel de communicatie instellingen in voor 9600 baud en zelfs pariteit. Sla het COMMs bestand op, ga terug uit MGR programma en breng alle juiste configuratie bestanden over naar schijf en laad deze bestanden in de CC1 waaraan uw REL-configuratie is gekoppeld. U moet nu klaar zijn om uw REL te bedienen via directe controle vanuit de CM9760- KBD. Voor handmatige of automatische controle van REL-functies onder macrocontrole, raadpleeg de desbetreffende secties van het MGR handleiding.

Pelco C543M-A — 3.3.3 Software-overwegingen diagram (page 17)
Afb. 12 · 3.3.3 Software-overwegingen
Pelco C543M-A — 3.3.3 Software-overwegingen diagram (page 17)
Afb. 13 · 3.3.3 Software-overwegingen

R1, R2...R8 GECONFIGUREERD ALS

TIJDELIJK OF VERGRENDELING (AFHANKELIJK VAN DE TOEPASSING)

Figuur 11. Het GPI-bestand instellen

Figuur 12. Het COMMS-bestand voor instellen

REL-operatie · RLE-bewerking

Page 18 of the Pelco C543M-A user manual — 4.2 VERRICHTING OP AFSTAND
Pagina 18 · klik om te vergroten
Pagina 18

4.0 INSTALLATIE

De fysieke installatie van de REL-eenheid is relatief eenvoudig, hoewel verschillende configuraties mogelijk zijn.

4.1 DIRECTE MONTAGE VAN DE RACK-MOUNT CONNECTOR

De REL-eenheid monteert in een standaard 19-inch rek en neemt slechts één spoorwegonderneming (1,75" of 4,45 cm) rackruimte (zie figuur 13).

4.2 VERRICHTING OP AFSTAND

De relais kan op iets anders dan een standaard 19-inch rek worden gemonteerd door de rack oren naar andere positie te verplaatsen. Indien gewenst, moet de REL-eenheid op enige afstand van het regelapparaat (CM9760-CC1) worden geplaatst; de RS-422 communicatie vanuit de relais unit naar de controller mag niet meer dan 4.000 voet (1.219 m) bedragen.

Pelco C543M-A — 4.2 VERRICHTING OP AFSTAND diagram (page 18)
Afb. 14

Figuur 13. Eenheidsafmetingen en Rack-Mount installatie

Page 19 of the Pelco C543M-A user manual — 4.3 MADELIEFJESKETEN
Pagina 19 · klik om te vergroten
Pagina 19

4.3 MADELIEFJESKETEN

Daisy-chaining treedt op wanneer meer dan 64 relais nodig zijn.

Belangrijker is dat elke eenheid geconfigureerd moet worden om een uniek adres te hebben, aangeduid als Frame Address. In punt 3.3.1 wordt ingegaan op de aanpak van REL-eenheden. Wat volgt is een discussie over de fysieke aansluiting van meerdere REL-eenheden. Systeemsoftware ondersteunt tot 700 GPI's of 5.600 relais. Of het nu gaat om twee of meerdere REL-eenheden, de eerste eenheid is verbonden met zijn De volgende eenheden zijn op dezelfde manier aan elkaar geketend.

Figuur 14 illustreert de fysieke aansluiting van twee gecascadeerde configuraties, die elk negen REL-eenheden bevatten en waarvan het frameadres in figuur 9 is weergegeven.

Merk ook op dat de opmerkingen in het vorige deel over RS-422 bedrading loop afstanden van toepassing zijn hier bij rekening kabels afstand loopt tussen daisy-geketende eenheden.

Pelco C543M-A — 4.3 MADELIEFJESKETEN diagram (page 19)
Afb. 15

HET ONDERSTAANDE DIAGRAM GEEFT GELDIGE FYSIEKE AANKOPPELVARIATIES VAN DE SETUP BESPROKEN IN FIGUUR 9 (VEEL ANDERE ZIJN MOGELIJK).

AANGEZIEN ELKE EENHEID EEN UNIEK ADRES HEEFT, MAAKT HET GEEN VERSCHIL WAAR IN DE CASCADEKETEN ZICH EEN BEPAALDE UNIT BEVINDT.

CONNECT-UP (1) EN (2) VERSCHILLEN FYSIEK, MAAR ZIJN OPERATIONEEL HETZELFDE (ZIE NOOT).

WISSELKABEL OF OMGEKEERDE KABEL (ZIE HET GEDEELTE OVER COMMUNICATIECONNECTOREN)

MAAR OPERATIONEEL HETZELFDE OMDAT HET FRAME ADRES NIET IS VERANDERD.

Figuur 14. Configuratie van de Relay Unit Daisy-Chain

Page 20 of the Pelco C543M-A user manual — 5.2.1 Informatie Terugwinning
Pagina 20 · klik om te vergroten
Pagina 20

5.0 BEWERKING

5.1 OPERATIONEEL OVERZICHT

De basisfunctie van de REL-eenheid is om gebruikers/operators in staat te stellen verschillende randapparatuur via relaiscontacten aan te sturen. Elke REL-eenheid verwerkt en voert alleen commando's uit met adressen die overeenkomen met dat van de RL (frameadres). Wanneer een REL een opdracht met ongepast adres ontvangt, geeft het deze door aan de volgende eenheid (indien van toepassing) via zijn OUT-poort.

Wanneer de macht voor het eerst wordt toegepast op de eenheid, RAM is gewist en initialisatie routines worden genoemd. De power LED is aangestoken, de operationele chips zijn geconfigureerd, interrupt-a priori banden worden ingesteld en de Data LED begint te knipperen met ongeveer 1/2 seconde intervallen (zie artikel 3.1.2, leds). De eenheid wacht op zijn eerste geldige com-mand.

5.2 DE CM9760-REL VAN HET CM97 60-KBD BEDIENEN

Directe controle van randapparatuur die aan REL's is bevestigd vanuit een CM9760-KBD, is relatief eenvoudig zodra u hebt vastgesteld welke GPI te bellen en AUX om te activeren. In het volgende deel bespreken we twee methoden om deze informatie te verkrijgen. Methode 1 gebruikt figuur 16 en tabel A; methode II maakt alleen gebruik van de CM9760-REL GPI/AUX CAlcULATATOR (alleen verwijzingen naar VCRC negeren aan de achterkant van de rekenmachine).

5.2.1 Informatie Terugwinning

ONS VOORBEELD: Stel dat u vijf cascaded REL-eenheden hebt en het randapparaat wilt activeren, bevestigd aan relais 39 op REL unit 5.

Welke informatie moet u weten? Waar vind je de informatie?

Eerst moet je twee dingen bepalen:

1. Welke GPI om de 704 beschikbaar te bellen.
2. Welke AUX, geassocieerd met de GPI, om te drukken.

Methode I

Figuur 15 is een fysieke weergave van ONS VOORBEELD. We zullen het ook gebruiken om de informatie te hervatten die nodig is voor het uitvoeren van de stappen zoals weergegeven in figuur 16.

Eerst het GPI bereik. Elke REL-eenheid wordt geassocieerd met een bereik van acht GPI's. In onze opeenvolgende cascaded units heeft REL 5 een GPI bereik van 33-40. (Als we in plaats daarvan geïnteresseerd waren geweest in REL unit 1, dan zou het GPI bereik dat wij zouden willen 1-8) zijn.

Het GPI bereik kan op een aantal manieren worden bepaald: (1) u heeft misschien al een lijst of (2), je kunt het frame/sub-frame adres van de fysieke REL eenheid vergelijken met die in tabel A en dus vinden de GPI range en (3), als je al weet dat het raam / sub-frames adres, kun je alleen Tabel A gebruiken.

Vanaf de linker in Figuur 15 kunt u rechts van GPI 37 volgen naar waar het snijdt met AUX geassocieerd met relaisgroep 33-40. GPI 37, is daarom de specifieke GPI die we nodig hebben om onze taak te vervullen. Van acht AUX-geten met GPI 37, kunnen we zien dat AUX 7 is degene die wij nodig hebben. Volg de verticale lijn van AUX 7 tot waar het snijdt de bijbehorende relais nummers en u vindt nummer 39.

Page 21 of the Pelco C543M-A user manual — 15 Fysieke vertegenwoordiging van figuur 16
Pagina 21 · klik om te vergroten
Pagina 21
Pelco C543M-A — 15 Fysieke vertegenwoordiging van figuur 16 diagram (page 21)
Afb. 16 · 15 Fysieke vertegenwoordiging van figuur 16

REL UNIT 1 REL UNIT 2 REL UNIT 3 REL UNIT 4 REL UNIT 5

Figuur 15. Fysieke vertegenwoordiging van figuur 16

Page 22 of the Pelco C543M-A user manual — 5.2.2 Operatie toetsenbord
Pagina 22 · klik om te vergroten
Pagina 22

Methode II . De CM9760-GPI/AUX Calculator

Als we het zojuist in figuur 15 besproken en geïllustreerde voorbeeld opnieuw bekijken, kunnen we onmiddellijk de informatie vinden die nodig is door direct af te lezen van de gegevensvakken op de voorkant van de rekenmachine.

Verplaats het rekenmachinewiel totdat de nummer .5" verschijnt in de Relay Unit # doos. Ga naar de tafel rechts daarvan en lokaliseer relais 39 in het gele gemarkeerde vak; reis links langs die rij en lees GPI 37 uit op de gpi Range slot. Vervolgens lees je de AUX die nodig is af door naar de Associated aux rij te kijken en zoek het nummer van de Aux # direct boven 39. U heeft nu de benodigde informatie (bel GPI 37, druk op AUX 7) om het gewenste relais te bedienen vanaf 9760-KBD. Zodra de GPI en AUX informatie bij de hand is, controle van het toetsenbord is eenvoudig. (Zie punt 5.2.2, "KEYBOARD-WERKING").

Andere bewerkingen met behulp van de Calculator De CM9760-GPI/AUX Calculator is handig voor andere bewerkingen dan het verkrijgen van de informatie die nodig is om direct toetsenbordbesturing te kunnen uitvoeren.

Andere toepassingen kunnen het volgende omvatten:

1. Als referentie voor het instellen van frame/sub-frame adresschakelaars bij de installatie van een groep gecascadede REL eenheden in een systeeminstallatie. Geef gewoon elke Relay Unit # weer in de volgorde die het geïnstalleerd is (1-5, laten we zeggen) en bij iedere instelling van het wiel, lees uit het frame/sub-frame Dip Schakel metingen af en zet de bijbehorende switches op de REL eenheid zelf.
2. Als u het GPI bereik van een bepaalde eenheid moet kennen, beweeg dan het wiel totdat de DIP-schakelaarinstellingen overeenkomen met die welke in de rekenmachine zijn weergegeven. Lees direct het GPI-bereik voor de gegeven REL-eenheid af.
3. Controleer de geldigheid van een GPI-oproep.
4. Gebruik het wiel tijdens de programmering van GPI en andere gerelateerde bestanden om dubbel-checken of de relatie tussen de GPI's wordt gedefinieerd met betrekking tot het relais daadwerkelijk worden ingesteld voor gebruik op welke eenheid.
5. Als informatiebron in probleemoplossingssituaties.

5.2.2 Operatie toetsenbord

Met behulp van de specifieke GPI/AUX-informatie verkregen via methode I of methode II, is het mogelijk om het gewenste randapparaat te bedienen vanaf CM9760-KBD.

Hieronder vindt u de stappen die nodig zijn om deze informatie te gebruiken voor directe controle op het toetsenbord 9760.

Page 23 of the Pelco C543M-A user manual — 16 Controlling REL-uitvoercontacten van de CM9760-KBD
Pagina 23 · klik om te vergroten
Pagina 23

Zodra het systeem draait en een toetsenbord on-line is, wordt de directe controle van een REL als volgt (zie figuur 16):

1. Gebruik het toetsenbord om in te voeren wat de relaisuitvoer is die u wilt activeren (gegevens verkregen via methode I of methode II).
2. Na het invoeren van de gewenste nummer, drukt u op de GPI-knop om het submenu te verhogen.
3. Het GPI submenu toont de eerste zes van acht hulpfunctiepictogrammen, overeenkomend met 6 relais die geassocieerd zijn met het geselecteerde GPI. Druk op de MEER knop om de resterende twee te zien.
4. Druk op de juiste AUX functieknop direct onder het gewenste Aux-pictogram om het relais en bijbehorende randapparaat te activeren.
5. Herhaal stap 1 tot en met 4 om extra apparaten te bedienen.
Pelco C543M-A — 16 Controlling REL-uitvoercontacten van de CM9760-KBD diagram (page 23)
Afb. 17 · 16 Controlling REL-uitvoercontacten van de CM9760-KB…

Figuur 16. Controleren REL-uitvoercontacten vanuit de CM9760-KBD

Page 24 of the Pelco C543M-A user manual — MECHANISCH
Pagina 24 · klik om te vergroten
Pagina 24

6.0 SPECIFICATIES

ELEKTRISCH

RELAISCONTACTEN VAN DE EENHEID Parameters: Maximale schakelcapaciteit 60 Watt Maximum bedrijfsspanning 125V AC/DC Maximale stroomsterkte 2 Ampère Contactweerstand 75 m ohm Gespecificeerde belastingsparameters: .5A @ 125 VAC 2A versus 30 VDC

REL-UNITE invoerspanningAutomatisch uitrusten 100-240 VAC 50/60 Hz
VermogenVerbruik: 30 vA, 5 watt

Input: RS-422, RJ-45 stekker DIP switch instelbare baud rate.

UitvoerRS-422, RJ-45 aansluiting. DIP-schakelaar selecteerbare baud rate
UitvoerRS-232, DB-9 aansluiting
Indicatoren2 power LED's, groene 1 data led, rood
Fusing500 mA, 250V

ALGEMEEN

Afmetingen: 17,4" B x 1,73" H x 8,54" D (44,2 cm x 4,39 cm x 21,69 cm)

Bedrijfstemperatuur32 °F tot 122°F (0 °C tot 50 °C)
Gewicht8 lb (3,63 kg)

MECHANISCH

REL-ingang: Vier dualheader, 32 ingangsconnectoren met paarpluggen Vermogen: 3-draads, #18 AWG RS422: Twee RJ-45 aansluitingen RS-232: Eén DB-9 stekker (alleen voor gebruik in de fabriek) Uitstellen: Een 3pin kopstuk met paringsstekker

** Voor informatie over aanvullende gespecificeerde, bekende parameters, zie indien nodig de speci-ficeringsbladen voor relaistype G6SK-2F-H van OMRON.

(Ontwerp en productspecificaties kunnen zonder kennisgeving worden gewijzigd.)

Datapoorten · Connectors

Page 25 of the Pelco C543M-A user manual — REVISIEGESCHIEDENIS
Pagina 25 · klik om te vergroten
Pagina 25

7.0 GARANTIE- EN RETOURINFORMATIE

GARANTIE

Indien een garantiereparatie vereist is, dient de Dealer contact op te nemen met Pelco om (800) 289-9100 of (559) 292-1981 voor het verkrijgen van een reparatievergunning nummer BR en moet hij volgende informatie verstrekken:

Pelco zal alle goederen die in materiaal of afwerking zijn aangetast gedurende een periode van één jaar na de datum van verzending kosteloos repareren en vervangen. Uitzonderingen op deze garantie zijn als hieronder vermeld:

  • Vijf jaar op Pelco vervaardigde camera's (CC3500/CC3600/CC3700 en MC3500/MC3600/MC3700 Serie); twee jaar op alle andere camera' s.
1. Model en serienummer 2. Datum van verzending, P.O. nummer, verkoopordernummer of Pelco-factuur nr. 3. Gegevens over het defect of probleem
  • Drie jaar op Genex ® Series (multiplexers, server en toetsenbord) en 090 serie Camclosure ® Camera System.

Als er een geschil is over de garantie van een product dat niet onder bovengenoemde garanties valt, gelieve bij retournering ook een schriftelijke ex-planatie met het product te vermelden.

  • Twee jaar op 100/150, 200 en 300 Series Camlocking ® Camera Systemen.
  • Twee jaar op camera's en alle standaard gemotoriseerde of vaste brandpuntslenzen.

De wijze van retourzending is gelijk aan of gelijk aan de methode waarmee het artikel door Pelco werd ontvangen.

  • Twee jaar op Legacy ®, CM6700/CM6800/CM68000E/CM8550/CM9500/ CM9740/CM9760 Matrix, DF5 en DF8 Series Fixed Dome producten.

GEEFT

Om onderdelen die voor reparatie of krediet naar de fabriek worden teruggestuurd, te versnellen, gelieve om een nummer van het certificaat (CA-nummer bij terugzending voor credit en RA-nummer indien opnieuw in gebruik genomen) op te vragen.

  • Twee jaar op Spectra ®, Esprit ® en PS20-scanners, ook bij continu bewegingstoepassingen.
  • Twee jaar op Esprit® en WW5700 serie raamwisser (excl. wisserbladen).
  • Achttien maanden op DX Series digitale videorecorder.

Alle goederen die voor krediet worden geretourneerd, kunnen onderworpen zijn aan een toeslag van 20% bij het uitzetten en opknappen.

  • Een jaar (behalve videokoppen) op videocassetterecorders. Videokoppen worden gedurende zes maanden afgedekt.

Goederen die worden geretourneerd voor reparatie of krediet moeten duidelijk zijn geïdentificeerd met het toegewezen CA-nummer en de vracht moet vooraf betaald worden. Schip naar het adres hieronder.

  • Zes maanden op alle pan en kantelen, scanners of vooraf ingestelde lenzen gebruikt in continue beweging toepassingen (dat wil zeggen, voorinstelling van de scan, rondleiding en auto-scan modes).

Als u zich bevindt in het continentale Verenigde Staten, Alaska, Hawaii of Puerto Rico stuur de goederen naar:

Pelco zal alle vervangende onderdelen en reparaties gedurende 90 dagen vanaf de datum van verzending door Pelco. Alle goederen die garantie nodig hebben, worden vooraf naar Pelco, Clovis, Californië verzonden. Reparaties die noodzakelijk zijn wegens misbruik, wijziging, normale slijtage of ongeval vallen niet onder deze garantie.

Dienstverlening Pelco 3500 Pelco Way Clovis, CA 93612-5699

Pelco neemt geen risico en is niet aansprakelijk voor schade of verlies als gevolg van het specifieke gebruik of de toepassing van de Producten. De aansprakelijkheid van Pelco voor elke vordering, ongeacht of deze berust op een contractbreuk, negli-gence en schending van rechten van enige partij of productaansprakelijkheid die betrekking heeft op de Producten, mag niet hoger zijn dan de prijs die door de Handelaar aan Pelco betaald is. In geen geval zal Pelco aansprakelijk zijn voor enige bijzondere, incidentele of gevolgschade (inclusief gebruiksverlies, winstderving en schadeclaim van derden), maar dan wel veroorzaakt door nalatigheid van Pelco of anderszins.

Als u zich buiten het continentale Amerikaanse, Alaska, Hawaii of Puerto Rico bevindt en wordt geïnstrueerd om goederen terug te brengen naar de VS, kunt u een van de volgende doen:

Indien de goederen door een COURIER DIENST worden verzonden, wordt het goed gezonden naar:

Pelco 3500 Pelco Way Clovis, CA 93612-5699 Verenigde Staten

Indien de goederen door een FREIGHT FORWARDER worden verzonden, dient u deze te verzenden naar:

De bovenstaande garantie biedt de handelaar specifieke wettelijke rechten. De handelaar kan ook aanvullende rechten hebben, die onderhevig zijn aan variatie van staat tot staat.

Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 Verenigde Staten

Telefoon650-737-1700 Fax: 650-737-0933

REVISIEGESCHIEDENIS

Handleiding # Datum Commentaar C538M 12/98 Vertaald uit het Frans. C538M-A 3/04 Herziene figuren 2 en 10 met RS-232 informatie. Herziene specificaties. Bijgewerkt Garantie en Terugkeer Informatie.

® Pelco, het Pelco logo, Spectra, Genex, Legacy, Esprit, Camclosure en System 9760 zijn geregistreerde handelsmerken van Pelco. © Copyright 2004, Pelco. Alle rechten voorbehouden.

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Pelco C543M-A

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Pelco C543M-A

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Pelco C543M-A handleiding-pdf

25 pagina's·2.4 MB·Beveiligingscamera·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…