CM9760-KBD/ CM9760-KBR System 9760™ Keyboar d Installation/ Operation Manual C540M (6/98) System 9750™ T In Out Near Far Open Close Fwd Bwd Run Mac Rcl Alt Prst Lock Mon 3 6 9 2 5 8 1 4 7 0 Cam Esc Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.
2 Pelco Manual C540M (6/98) CONTENTS Section Page 1.0 GENERAL ............................................................................................... 5 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS ............................... 5 1.2 CER TIFICA TIONS .
Pelco Manual C540M (6/98) 3 5.0 ADV ANCED OPERA TION ......................................................................... 22 5.1 PRESET CAMERA POSITIONS ...................................................... 22 5.1.1 Recalling Presets ...........
4 Pelco Manual C540M (6/98) LIST OF ILLUSTRA TIONS Figure Page 1 The CM9760-KBD/9760-KBR ............................................................ 6 2 Default Menu Icons ............................................................................ 7 3 DIP Switches .
Pelco Manual C540M (6/98) 5 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
6 Pelco Manual C540M (6/98) 2.0 DESCRIPTION The CM9760-KBD /CM9760-KBR keyboard is the interface between the operator and the CM9760 system. It can be used to select and maneuve r cameras, and to control a CM9760 system. The keyboard is programmable, and can be used to create and execute macros.
Pelco Manual C540M (6/98) 7 2.3 PHYSICAL LA YOUT The CM9760-KBD keyboard (see Figure 1) comprises: 1. Liquid crystal display (LCD) 4 . User definable control keys 2 .
8 Pelco Manual C540M (6/98) 2.3.5 Function Control This section of the keyboard provides the following facilities: Backward step through available camera selections Forward step through available came.
Pelco Manual C540M (6/98) 9 Figure 4. Com Ports and DIP Switches 3.0 INST ALLA TION AND SETUP 3.1 INST ALLA TION (Refer to Figure 5 on the next page) 1. Ensure that all DIP switches are in the OFF position, as shown in Figure 3. The DIP switches are on the underside of the keyboard.
10 Pelco Manual C540M (6/98) Figure 5. Basic Keyboard Setup Configuration and Wiring TX + 1 TX - 2 3 4 5 6 RX - 7 RX + 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 TX + 1 TX - 2 3 4 5 6 RX - 7 RX + 8 RJ-45 SERCO.
Pelco Manual C540M (6/98) 11 3.2.2 T o Leave Setup Mode 1. Select and return DIP switch 2 to the OFF position. 3.2.3 Cr eating a Setup PIN The factory settings for the CM9760-KBD include the default password 1234. An alternative password can be defined as follows: 1.
12 Pelco Manual C540M (6/98) 3.2.7 Dir ect Camera Control/Serial Por t Speeds Intercept ® receiver/drivers can be connected directly to the CM9760-KBD. In this configuration, cameras are controlled directly by the keyboard, and not via an inter- mediate switching matrix controller.
Pelco Manual C540M (6/98) 13 5. Select the camera icon, . 6. The next screen gives you a choice for “Camera direct control type.” Change, if necessary , the receiver/driver type listed as being attached to COM 1 and/or COM 2 to the receiver/driver type you actually have connected to COM 1 and/ or COM 2 (usually this is Pelco).
14 Pelco Manual C540M (6/98) 3.2.9 User Definable Control Keys The user definable control keys can be assigned various functions such as the enter function. While in setup mode, functions can be assigned to the user defin- able control keys as follows: 1 .
Pelco Manual C540M (6/98) 15 4 . Up to ten user-defined icons. T o upload a keyboard setup to all keyboards connected to a specific CM9760 system in a multiple-node CCTV installation, you must know the appropriate node number .
16 Pelco Manual C540M (6/98) The Keyboard LCD will indicate that it is cycling through the camera map settings; when finished, the LCD will display “End of Tx.” 3.2.12.2 Downloading Through the CM9760 System Setups can be downloaded/uploaded using keyboards connected to 9760 systems.
Pelco Manual C540M (6/98) 17 3.3 DIAGNOSTICS MODE Diagnostics mode is activated when DIP switch 1 is ON . T o leave diagnostics mode, select and return DIP switch 1 to the OFF position. Diagnostics mode allows you to test the: 1 . LCD display 2 . Keys 3.
18 Pelco Manual C540M (6/98) 4.0 OPERA TION 4.1 INTRODUCTION This chapter describes the operation of a CM9760 System using the CM9760-KBD. The following is assumed: 1. The CM9760 system is functional. 2. Initial power-up has been completed. 3. CM9760 setup files have been programmed.
Pelco Manual C540M (6/98) 19 4.4 LOGGING OFF T o log of f, select from the default menu, which can be reached by pressing . This will result in the prompt Are you sure you want to log off? Select to log off, or select to remain logged on. Alternatively , select monitor 0 to log OFF from any menu level without the log-off prompt.
20 Pelco Manual C540M (6/98) 4.7 LOCKING CAMERAS OR INPUT DEVICES T o lock a camera to a monitor (or other output device), select the appropriate cam- era or input, then select . 4.8 GROUP INPUT SELECTION The CM9760-KBD includes 24 user definable control keys.
Pelco Manual C540M (6/98) 21 4.9 OPERA TING PTZ CAMERAS The controls for PTZ cameras are located on the right-hand side of the keyboard (see Figure 1). If a selected camera is a PTZ type, the operator will be informed via a display prompt. The joystick is proportional, enabling variable speed drives (where fitted) to be speed controlled.
22 Pelco Manual C540M (6/98) 5.0 ADV ANCED OPERA TION 5.1 PRESET CAMERA POSITIONS A preset camera position is a set of parameters which define pan, tilt, zoom and focus adjustments. A preset camera position can be recalled as follows: 1. Manually , using the CM9760 keyboard 2 .
Pelco Manual C540M (6/98) 23 5.2 VCR CONTROL VCRs can be connected and controlled via a CM9760 system and CM9760 key- board in the following configurations: 1 . Via a start/stop signal from the Pelco Alarm Interface Unit (no full control) 2. V ia a Relay Interface unit, enabling remote control using the CM9760 key- board 3.
24 Pelco Manual C540M (6/98) NOTE: If the GPI number is valid, GPI n will be displayed (where n is the GPI number). If the GPI has not been installed, GPI not present will appear . If access to the GPI has been denied to that operator , GPI denied will ap- pear .
Pelco Manual C540M (6/98) 25 5.4.2 Pausing Macros T o pause a macro: 1. Select to display the running macro number. 2. Select and to step through macros that have been loaded. 3. When the required macro is selected, ensure that it is running by referring to the display .
26 Pelco Manual C540M (6/98) 5.4.5 Deleting Macr os T o delete a macro: 1. Using the numeric keypad, enter the required macro number . 2. Press to display the macro sub-menu. 3. Select to delete the specified macro. or , 1. Select from the default menu.
Pelco Manual C540M (6/98) 27 Using macros, camera sequences can be programmed directly from the CM9760 keyboard. T o program a macro: 1. Select from the default menu. 2. If necessary , enter your define PIN. 3. Select to display the macro program sub-menu 4.
28 Pelco Manual C540M (6/98) 5.6 SETTING THE TIME AND DA TE The time and date can be changed from the 9760 keyboard. T ime and date infor- mation is stored in the CM9760 system. T o change the time and date: 1. Select from the default menu, in order to call up the program sub- menu.
Pelco Manual C540M (6/98) 29 6.0 ALARMS Alarms can be armed or disarmed from the CM9760 keyboard. Alarms which are armed using the CM9760 keyboard affect only the operators responsible for them. Such operators receive alarm messages and are able to reset these alarms when triggered.
30 Pelco Manual C540M (6/98) 1 . Select , to display the alarm sub-menu. Select an alarm using and . 2. Select . 3. Enter your define PIN. 4. T o disarm more alarms repeat steps 1 to 3. 5. Having finished disarming the alarms, select or press . 6.3 ALARM ST A TUS T o see if a specific alarm is armed: 1.
Pelco Manual C540M (6/98) 31 7.0 APPENDICES Appendix A. Keyboard LCD Default Menu and Tree Listing Appendix B. Icon Legend Appendix C. Keyboard Connector Pin-Outs Appendix D. Keyboard to Keyboard Cabling Connections Appendix E. Setup Mode Menu T ree (DIP Switch 2 ON) Appendix F .
32 Pelco Manual C540M (6/98) Appendix A. Keyboard LCD Default Menu and T ree List MONITOR CAMERA PRESET P R OGRAM G P I ALARM MACR O LOG OFF DEF A UL T MENU FORW ARD BACKW ARD Q U I T MONIT OR SUB MEN.
Pelco Manual C540M (6/98) 33 Appendix B. Icon Lagend LOG OFF PIN SELECTION CAMERA SELECTION MONIT OR SELECTION GROUP CAMERA SELECTION FWD STEP BWD STEP CAMERA PRESET DELETE CAMERA PRESET GO T O A PRES.
34 Pelco Manual C540M (6/98) Appendix C. Keyboard Connector Pin-Outs RS-422 Serial Port Main port used for power into keyboard, and for comm’ s link to Pelco CM9760-CC1 CPU. It is also used to drive Camera Control Receiver/ Drivers in direct mode. These I/O lines are connected to 8 way RJ socket JP1 as shown below .
Pelco Manual C540M (6/98) 35 Appendix C. Keyboard Connector Pin-Outs (Continued) I 2 C Bus Port This special port will be used in future for expansion of keyboard func- tionality - it is not available for use as a general purpose serial commu- nications port.
36 Pelco Manual C540M (6/98) Appendix D. Keyboard-to-Keyboard Cabling Connections TO IDENTIFY A CABLE TYPE, PHYSICALL Y ORIENT THE RJ-45 CONNECTORS AS DEPICTED IN THE DRA WINGS T O THE LEFT .
Pelco Manual C540M (6/98) 37 Appendix E. Setup Mode Menu Tree (DIP Switch 2 ON) KEYBOARD DEFINE MODE > NOT DEFINED NUM 0 KEY DEFINE NUM 1 PLEASE ENTER A KEY NUM 3 NUM 4 NUM0 MONx MAC ARM/DISARM NUM.
38 Pelco Manual C540M (6/98) Appendix F . Diagnostic Mode Menu Tree (DIP Switch 1 ON) DIAGNOSTIC MODE V3.3 LCD TEST DIAGNOSTIC MODE V3.3 KEYBOARD TEST V3.3 PLEASE ENTER A KEY JOYSTICK POSITION - (129,129) DIAGNOSTIC MODE V3.3 SERIAL PORT TEST V3.3 (FOR F ACTORY USE ONL Y) DIAGNOSTIC MODE V3.
Pelco Manual C540M (6/98) 39 Appendix G. CM9760-KBD Specifications ELECTRICAL Input Voltage: 12 VDC from 120 or 230 VAC, 50/60 Hz (+10%) power pack Power Consumption: 400 mA Communications: RS-422, full-duplex Operating Distance: For direct control operation, Up to 3,900 ft (1.
40 Pelco Manual C540M (6/98) 8.0 WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Excep- tions to this warranty are as noted below: • Three years on Genex™ Series multiplexers.
Een belangrijk punt na aankoop van elk apparaat Pelco CM9760-KBR (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco CM9760-KBR heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco CM9760-KBR vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco CM9760-KBR leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco CM9760-KBR krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco CM9760-KBR bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco CM9760-KBR kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco CM9760-KBR . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.