DRD08/DRD14 Series Receiver/Drivers for Intercept ® Series Domes Installation/ Operation Manual C466M-E (6/99) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.
2 Pelco Manual C466M-E (6/99) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 5 1.1 IMPORT ANT SAFEGUARDS AND WARNINGS ............................... 5 2.0 DESCRIPTION .
Pelco Manual C466M-E (6/99) 3 LIST OF ILLUSTRA TIONS Figur e Page 1 PC Board Locations ........................................................................... 8 2 CPU Board ..........................................................................
4 Pelco Manual C466M-E (6/99) (This page intentionally left blank.).
Pelco Manual C466M-E (6/99) 5 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed.
6 Pelco Manual C466M-E (6/99) 2.0 DESCRIPTION The DRD08 Series of receiver/drivers is part of the IDS08 Intercept ® Series of domes. The IDS08 Series is an integral system that includes a back box (BB08), dome drive (DD08), dome receiver/driver (DRD08), and imager/optics package (IOP08).
Pelco Manual C466M-E (6/99) 7 DRD08D22 Receiver/driver for 8" Intercept ® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns.
8 Pelco Manual C466M-E (6/99) 3.0 INST ALLA TION Installation of the Dome Receiver/Driver (DRD) into the DD08 or DD14 Dome Drive is accomplished at the factory . This is not a field installable option. 3.1 ADJUSTMENTS Although the DRD has been adjusted and set at the factory , some settings can and may require field adjusting.
Pelco Manual C466M-E (6/99) 9 Figure 3. R26/R27 Adjustment Location R26/R27 ADJUSTMENT Figure 2. CPU Board ON 1 2 3 4 5 6 7 8 MADE IN USA PCB8500110D JP2 JP1 RESET SWITCH JP3 JP5 JP6 SW1 UNTERMINA TED.
10 Pelco Manual C466M-E (6/99) T able A. Switch Settings for SW1 - D-T ype Control NOTES: For Coaxitron ® controls, SW1 is not used. For P-type control systems, refer to Table B.
Pelco Manual C466M-E (6/99) 11 T able A Switch Settings for SW1 - D-T ype Control (continued) Receiver Address Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 49 OFF ON ON ON OFF OFF ON.
12 Pelco Manual C466M-E (6/99) T able A Switch Settings for SW1 - D-T ype Control (continued) Receiver Address Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 101 OFF ON OFF ON ON OFF O.
Pelco Manual C466M-E (6/99) 13 T able A Switch Settings for SW1 - D-T ype Control (continued) Receiver Address Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 153 OFF ON ON OFF OFF ON O.
14 Pelco Manual C466M-E (6/99) T able A Switch Settings for SW1 - D-T ype Control (continued) Receiver Address Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 205 OFF ON OFF OFF ON ON O.
Pelco Manual C466M-E (6/99) 15 T able B. Switch Settings for SW1 - P-T ype Control NOTES: For Coaxitron ® controls, SW1 is not used. For D-type control systems, refer to Table A.
16 Pelco Manual C466M-E (6/99) 4.0 OPERA TION Upon applying power , the unit starts a configuration routine after 15 seconds. 4.1 SCAN OPERA TION Three (3) different scan mode options are of fered and can be selected according to operator preference: Auto Scan; (AUX 2), continuous panning, with a 5-second stop on limits.
Pelco Manual C466M-E (6/99) 17 4.3 PRESET FUNCTIONS 1. The DRD***2* units are capable of 32 complete preset scenes. On DRD**A2* models, each preset can have a 20-character label. T o set a preset, first enter the label then program the position. 2. Once programmed, the DRD***2* can be commanded to the preset.
18 Pelco Manual C466M-E (6/99) Figure 4. Receiver/Driver Reset Button Location 4.6 PA TTERNS 1. The DRD***2* units are capable of one 60-second pattern. This pattern can consist of any standard pan/tilt or lens command. Presets, flip and turbo are not allowed in a pattern.
Pelco Manual C466M-E (6/99) 19 5.0 FIRMW ARE 5.1 COAXITRON CONTROL COMMAND This section describes the protocol used to send commands to the receivers via Coaxitron. The hardware interface is a 32-bit PWM (pulse width modulated) signal, wherein a one microsecond pulse is considered a zero and a two microsecond pulse is con- sidered a one.
20 Pelco Manual C466M-E (6/99) 5.1.2 Extended Commands Extended commands will always have B0 of Byte 2 set to one. The following num- bers are in hexadecimal format: Command Byte 1 Byte 2 Byte 3 Byte .
Pelco Manual C466M-E (6/99) 21 5.2.2 Addressing The address is set on the CPU board PCB85001 10. The switch is labeled SW1. Setting the switch in the “ON” position represents a zero. Refer to T able A. SW1.1 Address Bit 0 SW1.2 Address Bit 1 SW1.3 Address Bit 2 SW1.
22 Pelco Manual C466M-E (6/99) 5.2.4 Extended Commands Extended commands will always have B0 of Word 4 set to one. The following num- bers are in hexadecimal format: Command Word 3 Word 4 Word 5 Word .
Pelco Manual C466M-E (6/99) 23 5.3.2 Addressing The address is set on the CPU board PCB85001 10. The switch is labeled SW1. Setting the switch in the “ON” position represents a zero. The first five positions set the receiver address (1 through 5) from a range of 0 to 31.
24 Pelco Manual C466M-E (6/99) Command Word 3 Word 4 Word 5 Word 6 Set preset XX 00 03 00 01 to 20 Clear preset XX 00 05 00 01 to 20 Go to preset XX 00 07 00 01 to 20 180 Flip preset 00 07 00 21 Zero pan position 00 07 00 22 Set aux XX 00 09 00 01 to 08 Clear aux XX 00 0B 00 01 to 08 Remote Reset 00 0F 00 00 Pat.
Pelco Manual C466M-E (6/99) 25 6.0 CIRCUIT BOARD P ARTS LIST T able C. Circuit Board Parts List Model CPU Board Video Board Power Board Backplane DRD08A11 CPU08A11ASSY PCB8500101ASSY PCB8500130ASSY PC.
26 Pelco Manual C466M-E (6/99) 7.0 SPECIFICA TIONS Input Voltage: 24 VAC, 60 Hz, ± 10% at the drive Maximum Input Power AC Motor Dome Drive: Pan — 7.
Pelco Manual C466M-E (6/99) 27 7.1 REGULA TOR Y NOTICES NOTE: This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
28 Pelco Manual C466M-E (6/99) 8.0 WARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 1999, Pelco. All rights reserved.
Een belangrijk punt na aankoop van elk apparaat Pelco DRD14 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco DRD14 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco DRD14 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco DRD14 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco DRD14 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco DRD14 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco DRD14 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco DRD14 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.