Pelco DX9100
Inhoudsopgave 80 secties DX9200 Digital Video Recorder and DX9100 Viewstation · LIST OF ILLUSTRATIONS · LIST OF TABLES · IMPORTANT SAFETY INSTRUCTIONS · … TonenVerbergen
DX9200 Digital Video Recorder and DX9100 Viewstationp.1LIST OF ILLUSTRATIONSp.4LIST OF TABLESp.6IMPORTANT SAFETY INSTRUCTIONSp.7CAUTION:p.7REGULATORY NOTICESp.8RADIO AND TELEVISION INTERFERENCEp.8DESCRIPTIONp.9ETHERNET SWITCHp.9MODELSp.10FRONT VIEW (RECORDER)p.11 p.11 p.11BACK VIEW (RECORDER)p.12 p.12FRONT VIEW (VIEWSTATION)p.13DVD-RW/CD-RWp.13 p.13 p.13BACK VIEW (VIEWSTATION)p.14INSTALLATIONp.15INSTALLATION GUIDELINESp.16MOUNTINGp.17SLOTTED HOLES TOWARDS FRONT OF UNITp.18TAPERED ENDS TOWARDS REAR OF UNITp.18CONNECTIONSp.19POWER UP THE EQUIPMENTp.21PROGRAMMINGp.22VIEWSTATION NETWORK CONFIGURATIONp.22CHANGING THE VIEWSTATION’S IDENTIFICATIONp.23CHANGING THE VIEWSTATION’S IP ADDRESS AND SUBNET MASKp.24CHANGING THE RECORDER’S IDENTIFICATIONp.26TIME SYNCHRONIZATIONp.27SETTING DATE/TIME PROPERTIESp.28CLIENT CONFIGURATION UTILITYp.29RECORDER INITIALIZATION OPTIONSp.31SERVER STATEp.33ADVANCED RECORDER OPTIONSp.35DATABASE BACKUP AND REPAIRp.35DATABASE RESTORATIONp.36RAID MANAGER UTILITYp.45DISABLING THE RAID MANAGER GATEWAYp.45RAID MANAGER GATEWAY CONFIGURATIONp.45GATEWAY CONFIGURATION SETTINGSp.48Event Notificationp.48Netsend Settingp.49VIEWSTATION IP ADDRESSp.50RAID MANAGER HOME PAGEp.52DISK INFORMATION PLATEp.54HOST AND RAID INFORMATION PLATEp.56STATUS PLATEp.57CAMERA RECORDING PROPERTIESp.58CONTINUOUS RECORDING SCHEDULEp.60DAILY RECORDING SCHEDULEp.60WEEKLY RECORDING SCHEDULEp.62MOTION DETECTIONp.63CHANNEL SETUPp.64DEFINING USERSp.66Edit Existing Usersp.67Adding a New Userp.67Deleting a Userp.67ADVANCED FEATURESp.68I/O INTERFACEp.68I/O HANDLERp.68I/O MANAGERp.68CONNECTING AN ALARM UNITp.69RECORDERp.69ALARM UNIT CONFIGURATIONp.70I/O Manager for Alarm Unitp.72CONNECTING A RELAY UNITp.75RELAY UNIT CONFIGURATIONp.76I/O Manager for Relay Unitp.78CONNECTING A CM9760-CC1p.80CONNECTING A CM6800p.81NULL MODEM CABLEp.81RS-232 TO RS-422 CONVERTERp.81DATA TRANSLATOR CONFIGURATIONp.82I/O Manager for Data Translatorp.84DVR MANAGEMENTp.86DATA TRANSLATOR CONNECTIONSp.86
Page 1 of the Pelco DX9100 user manual — ®
Pagina 1 · klik om te vergroten
Pagina 1

I N S T A L L A T I O N M A N U A L

DX9200 Digital Video Recorder and DX9100 Viewstation

®

Pelco DX9100 — ® diagram (page 1)
Afb. 1
Page 2 of the Pelco DX9100 user manual — DX9200 Digital Video Recorder and DX9100 Viewstation
Pagina 2 · klik om te vergroten
Pagina 2
Page 2 of the Pelco DX9100 user manual — DX9200 Digital Video Recorder and DX9100 Viewstation
Page 3 of the Pelco DX9100 user manual — DX9200 Digital Video Recorder and DX9100 Viewstation
Pagina 3 · klik om te vergroten
Pagina 3
Page 3 of the Pelco DX9100 user manual — DX9200 Digital Video Recorder and DX9100 Viewstation
Page 4 of the Pelco DX9100 user manual — LIST OF ILLUSTRATIONS
Pagina 4 · klik om te vergroten
Pagina 4

LIST OF ILLUSTRATIONS

1. DX9200 System Overview 9 2. Front View of Recorder 11 3. Back View of Recorder 12 4. Front View of Viewstation 13 5. Back View of Viewstation 14 6. DX9200 Rack Mount Installation 18 7. 37-Pin Connectors 19 8. HASP Key Message 19 9. System Connections 20 10. Viewstation Network Identification Page 23 11. Viewstation Identification Changes Dialog Box 23 12. Viewstation Network Connections Window 24 13. Viewstation Local Area Connection Status Dialog Box 24 14. Viewstation Local Area Connection Properties Dialog Box 25 15. Viewstation Internet Protocol (TCP/IP) Properties Dialog Box 25 16. Server Configuration Utility Dialog Box 26 17. Server Identification Dialog Box 26 18. Date & Time Page 28 19. Time Zone Page 28 20. Client Configuration Login Dialog Box 29 21. Client Configuration Utility 29 22. Export to Server Dialog Box 30 23. DX9216H Frame Rate and Resolution 31 24. DX9208F Frame Rate and Resolution 31 25. License Information Dialog Box 31 26. Server State 33 27. Configuration Options 34 28. Error Alert 34 29. Advanced Options 35 30. Database Backup and Repair Confirmation 35 31. System Tray 36 32. Server Service Manager Window 36 33. Stop SQL Dialog Box 1 36 34. Stop SQL Dialog Box 2 36 35. Start/Continue Window 37 36. My Computer Window 37 37. Databases Window 38 38. Rename MSSQL 38 39. C Drive Databases Window 39 40. MSSQL Folders 39 41. Start/Continue Window 40 42. Database Backups Window 40 43. Explorer Windows 41 44. Restore Utility Dialog Box 41 45. System Tray 41 46. Server Service Manager Window 42 47. Stop SQL Dialog Box 1 42 48. Stop SQL Dialog Box 2 42 49. Start/Continue Window 42 50. Replace Database Dialog Box 43 51. Restore Confirmation Dialog Box 43 52. Operation Completed Dialog Box 43 53. Maintenance Dialog Box 43 54. Finished Scan Dialog Box 44 55. Finished Merging Dialog Box 44 56. Raid Manager Gateway Configuration Window 45 57. Default Server Information Window 46 58. Edit Server Window 46

Figure Page

Page 5 of the Pelco DX9100 user manual — LIST OF ILLUSTRATIONS
Pagina 5 · klik om te vergroten
Pagina 5

59. Add Server Window 46 60. Edit Group Window 47 61. Add Group Window 47 62. Event Notification Page 48 63. NetSend Setting Page 49 64. Internet Properties Window 50 65. Internet Information Services Window 50 66. Default Web Site Properties 51 67. Raid Manager Home Page 52 68. Storage Information Window 53 69. Controller Information Window 53 70. No Hard Drive Information 54 71. Configured Hard Drive Information 55 72. Newly Replaced Hard Drive Information 55 73. Spare Hard Drive Information 55 74. Host & Raid Information Screen 56 75. Host 1 Interface Details 56 76. RAID Information Details 57 77. Host 2 Interface Details 57 78. Status Plate 57 79. Camera Properties Dialog Box 58 80. Select Channel Dialog Box 59 81. Continuous Recording Schedule Page 59 82. Continuous Daily Recording Schedule Page 60 83. Daily Event Recording Page 61 84. Continuous Weekly Recording Schedule Page 62 85. Weekly Event Recording Schedule Page 62 86. Motion Detection Page 63 87. Camera Video Setup Page 64 88. User Access Dialog Box 66 89. User Manager Dialog Box 66 90. Connecting a CM9760-ALM 69 91. Alarm I/O Handler Configuration Dialog Box 70 92. CM9760 Alarm Driver Dialog Box 70 93. Device 2 Alarm Driver Dialog Box 71 94. CM9760 Alarm Configuration Dialog Box 71 95. Dialog Box to ConExternal 1 Source 72 96. Sample Configuration for External 1 Source 73 97. Dialog Box to ConExternal 2 Source 74 98. Connecting a CM9760-REL 75 99. Relay I/O Handler Dialog Box 76 100. CM9760 Relay Driver Dialog Box 76 101. Device 1 Relay Driver Dialog Box 77 102. CM9760 Relay Configuration Dialog Box 77 103. Relay Unit Step 3 Screen 78 104. Dialog Box to ConRelay Event Type 79 105. Connecting a CM9760-CC1 80 106. Connecting a CM6800 81 107. Data Translator I/O Handler Configuration Dialog Box 82 108. CM9760 Data Translator Driver Dialog Box 82 109. Device 1 Data Translator Driver Dialog Box 83 110. CM9760 Relay Configuration Dialog Box 83 111. Dialog Box to ConData Translator 84 112. Dialog Box to ConData Translator Event Type 85 113. Connecting a CM9760-DT for DVR Management 86 114. Data Translator Configuration Dialog Box 87 115. Data Translator Driver Dialog Box 87 116. Data Translator Driver Settings Dialog Box 87 117. CM9760-DT Configuration 88 118. Connecting a CM9760-REL for DVR Management 89 119. Relay Unit Configuration Dialog Box 90 120. Relay Unit Driver Dialog Box 90 121. Relay Unit Driver Settings Dialog Box 90

Page 6 of the Pelco DX9100 user manual — LIST OF TABLES
Pagina 6 · klik om te vergroten
Pagina 6

122. CM9760-REL Configuration Dialog Box 91 123. Change System Location 92 124. Select System Location 93 125. Power Supply Replacement 94 126. Raid Server Window 95 127. Login Window 95 128. Remote Monitor Window 96 129. Fast Trak Window 96 130. Array Window 97 131. Drive 2 Status 97 132. Drive 1 Status 98 133. Hard Drive Replacement 98 134. Rebuilding System Array 99

LIST OF TABLES

A. Server State Symbols 34 B. Disk Status 54 C. Channel Setup 65 D. User Access Rights 66

Table Page

Page 7 of the Pelco DX9100 user manual — CAUTION:
Pagina 7 · klik om te vergroten
Pagina 7

IMPORTANT SAFETY INSTRUCTIONS

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum specified load.
1. A readily accessible disconnect device shall be incorporated in the building installation wiring.
2. The socket-outlet shall be installed near the equipment and shall be easily accessible.
3. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other that contained in the operating instructions unless you are qualified to do so.
4. CAUTION: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type. Dispose of used batteries according to the instructions provided by the battery manufacturer. Only use replacement parts recommended by Pelco.

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

CAUTION:

RISK OF ELECTRIC SHOCK.

This symbol indicates that there are important operating and mainte- nance instructions in the literature accompanying this unit.

DO NOT OPEN.

Page 8 of the Pelco DX9100 user manual — RADIO AND TELEVISION INTERFERENCE
Pagina 8 · klik om te vergroten
Pagina 8

REGULATORY NOTICES

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

RADIO AND TELEVISION INTERFERENCE

This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

In order to maintain compliance with FCC regulations shielded cables must be used with this equipment. Operation with non- approved equipment or unshielded cables is likely to result in interference to radio and television reception.

Page 9 of the Pelco DX9100 user manual — ETHERNET SWITCH
Pagina 9 · klik om te vergroten
Pagina 9

DESCRIPTION

The DX9200 system consists of at least one digital video recorder (DVR), one viewstation, and one storage unit.

The DX9200 digital video recorder can record images simultaneously from as many as 48 cameras at 15 images per second (ips) or from as many as 40 cameras at 30 ips. The DX9200 digital video recorder is compatible with DX9200HDDI storage units.

Thousands of cameras can be recorded and viewed at the same time when multiple DX9200 recorders and DX9100 viewstations are linked to each other through a local area network (LAN) or wide area network (WAN).

The DX9100VS viewstation has these features:

  • Simultaneous viewing of live or recorded video can be seen from as many as four cameras.
  • Live video can be marked for later review by the user or by using the motion detection feature.
  • Scan feature allows the user to search recorded video for movement of a specific object.
  • Video files can be saved in MPEG format to a compact disk, hard drive, or anywhere on the network.
  • A current video frame can be printed on a standard PC printer.
Pelco DX9100 — DESCRIPTION diagram (page 9)
Afb. 2

ETHERNET SWITCH

Pelco DX9100 — ETHERNET SWITCH diagram (page 9)
Afb. 3

Figure 1. DX9200 System Overview

Page 10 of the Pelco DX9100 user manual — MODELS
Pagina 10 · klik om te vergroten
Pagina 10

MODELS

DX9100VSR Viewstation; rack mountable DX9216H Records at maximum 15 images per second (ips); 16 channels DX9232H Same as DX9216H, except has 32 channels DX9248H Same as DX9216H, except has 48 channels DX9208F Records at maximum 30 ips; 8 channels DX9216F Same as DX9208F, except has 16 channels DX9224F Same as DX9208F, except has 24 channels DX9232F Same as DX9208F, except has 32 channels DX9240F Same as DX9208F, except has 40 channels

Page 11 of the Pelco DX9100 user manual —
Pagina 11 · klik om te vergroten
Pagina 11

FRONT VIEW (RECORDER)

Rack Ear (2) Handle (2) Fan Ventilation Lock (2 Keys Supplied) Power LED HDD (Hard Disk Drive) LED Fan (2) Power Button 3.5-Inch Floppy Drive

Pelco DX9100 —  diagram (page 11)
Afb. 4

Figure 2. Front View of Recorder

Page 12 of the Pelco DX9100 user manual —
Pagina 12 · klik om te vergroten
Pagina 12

BACK VIEW (RECORDER)

Power Supply (2) Power Supply Reset Button AT Keyboard Connector (Not Used) SCSI Connector (2) 37-Pin Connector (Maximum of 6) RS-232 Connector (COM 2) RS-232 Connector (COM 1) RJ-45 Network Connector USB Port for HASP USB Key PS/2 Connector (Keyboard/Mouse) VGA Connector

Pelco DX9100 —    diagram (page 12)
Afb. 5

Figure 3. Back View of Recorder

Page 13 of the Pelco DX9100 user manual —
Pagina 13 · klik om te vergroten
Pagina 13

FRONT VIEW (VIEWSTATION)

HDD (Hard Disk Drive) LED

Key Lock (2 Keys Supplied)

DVD-RW/CD-RW

3.5-Inch Floppy Drive

Figure 4. Front View of Viewstation

Show 6 more labels / short text on this page
Power LED · Fan Ventilation · Handles · Rack Ears · Fan · Power Button
Page 14 of the Pelco DX9100 user manual — BACK VIEW (VIEWSTATION)
Pagina 14 · klik om te vergroten
Pagina 14

BACK VIEW (VIEWSTATION)

Power Input (100-240 VAC)

PS/2 Connectors (Keyboard/Mouse)

Secondary RJ-45 Network Connector

RS-232 Connector (COM 1)

Primary RJ-45 Network Connector

Audio Inputs (Line In, Line Out/Headphone, Microphone In)

RS-232 Connector (COM 2)

Pelco DX9100 — BACK VIEW (VIEWSTATION) diagram (page 14)
Afb. 6

Figure 5. Back View of Viewstation

Show 4 more labels / short text on this page
USB Ports · Parallel Port · VGA Connectors · Modem Connectors
Page 15 of the Pelco DX9100 user manual — INSTALLATION
Pagina 15 · klik om te vergroten
Pagina 15

INSTALLATION

Make sure all parts are present for each unit.

1 Recorder 4 Power cords (2 USA standard and 2 European standard) 2 Brackets 6 Screws, 8-32 x .250-inch, pan head 2 Rear mounting rails 8 Screws, 10-32 x .375-inch, flat head 2 Front mounting rails 6 Screws, 8-32 x .375-inch, pan head with washers 4 Screws, 10-32 x .375-inch, flat head 1 Patch panel 1-6 37-pin connector cables 4 Screws, 10-32 x .750-inch, Phillips, pan head with washers 1 Y-cable 2 Keys 1 USB HASP key 1 Windows® 2000 license label (on unit) 1 pcAnywhere™ package 1 Resource CD

1 Viewstation 2 Power cords (1 USA standard and 1 European standard) 1 PS/2 keyboard 1 PS/2 mouse 1 Analog video output adapter cable 1 Modem cable 2 Brackets 6 Screws, 8-32 x .250-inch, pan head 2 Rack ears 4 Screws, 10-32 x .250-inch, flat head 4 Screws, 10-32 x .750-inch, Phillips, pan head with washers 2 Rear mounting rails 8 Screws, 10-32 x .375-inch, flat head 2 Front mounting rails 6 Screws, 8-32 x .375-inch, pan head with washers 4 Screws, 10-32 x .375-inch, flat head 2 Keys 1 Windows 2000 license label (on unit) 1 pcAnywhere package 1 Resource CD

Recorder · Viewstation

Page 16 of the Pelco DX9100 user manual — INSTALLATION GUIDELINES
Pagina 16 · klik om te vergroten
Pagina 16

INSTALLATION GUIDELINES

Follow these guidelines for the best system performance.

  • The DX9200 recorders require connection to an uninterruptible power supply (UPS) to ensure no corruption of data during a power loss.
  • The DX9200 system must be installed in a climate-controlled room. The temperature range should be 41 ° to 85 ° F (5 ° to 29 ° C).
  • All network devices that will transport DX9200 video must be capable of moving multicast traffic.
  • Pelco recommends that the DX9200 recorder be installed in a ventilated rack enclosure.
  • When securing the recorder to the rack enclosure, do not lift the recorder by the handles only.
  • Make sure the rack enclosure is properly grounded.
  • Pelco recommends that a spare phone line be installed and connected to a primary DX9100 viewstation to allow the Pelco Technical Support Group to dial into the site upon customer request. Pelco personnel will not make changes unless authorized by the customer. This phone line can be protected by a password to prevent unauthorized access.

Lack of adherence to these guidelines gives Pelco discretion in honoring product warranty.

Page 17 of the Pelco DX9100 user manual — MOUNTING
Pagina 17 · klik om te vergroten
Pagina 17

MOUNTING

The DX9200 recorder and DX9100 viewstation are supplied with the necessary parts for mounting into an industry standard 19-inch (48.26 cm) wide equipment rack. The units can also be placed on a flat surface, such as a shelf.

Page 18 of the Pelco DX9100 user manual — SLOTTED HOLES TOWARDS FRONT OF UNIT
Pagina 18 · klik om te vergroten
Pagina 18

To install the unit into an equipment rack:

1. Attach the two brackets to both sides of the unit. 2. Attach the mounting rails to the equipment rack. 3. Place the unit onto the mounting rails. It should slide in and out of the rack easily. 4. Fasten the rack ears to the equipment rack.
Pelco DX9100 — SLOTTED HOLES TOWARDS FRONT OF UNIT diagram (page 18)
Afb. 7

(6) SCREWS, 8-3 2X .375-INCH, PAN HEAD WITH WASHERS

(4) SCREWS, 10-3 2X .750-INCH PHILLIPS, PANHEAD WITH WASHERS

SLOTTED HOLES TOWARDS FRONT OF UNIT

TAPERED ENDS TOWARDS REAR OF UNIT

Figure 6. DX9200 Rack Mount Installation

Page 19 of the Pelco DX9100 user manual — CONNECTIONS
Pagina 19 · klik om te vergroten
Pagina 19

CONNECTIONS

Refer to Figure 9.

1. Connect the viewstation and the recorder to an Ethernet switch. Use straight, shielded network cables.
2. Connect the supplied cables from the 37-pin connectors on the recorder to the 37-pin connectors on the back of the patch panel.

Figure 7. 37-Pin Connectors

3. Connect a SCSI cable from the recorder to the storage unit.
4. Connect cameras to the video input coaxial connectors on the front of the patch panel, and then set the switches on the back of the patch panel to Terminated (75 ohms). This is the default setting. You can use a minimum of 8 camera inputs or a maximum of 48 camera inputs.
5. Plug the HASP (Hardware Against Software Piracy) USB key into the USB port on the recorder. A red light on the key indicates that it is working properly. The key contains the product license and its configured permissions. The following message will appear when you power up the system if you do not plug in the HASP key.
Pelco DX9100 — CONNECTIONS diagram (page 19)
Afb. 8

Figure 8. HASP Key Message

6. Connect a monitor, keyboard, and mouse to the viewstation and to the recorder.
7. Connect all power cords.
8. Connect looping video sources, such as monitors, to the video output coaxial connectors on the front of the patch panel, and then set the switches on the back of the patch panel to Looped.
9. Connect a CM9760-REL, CM9760-ALM, or CM9760-DT to COM 1 or COM 2 on the recorder. Refer to the Advanced Features section.
Page 20 of the Pelco DX9100 user manual — CONNECTIONS
Pagina 20 · klik om te vergroten
Pagina 20
Pelco DX9100 — CONNECTIONS diagram (page 20)
Afb. 9
10/100 BASE T ETHERNET INTERFACEALLOWS MULTIPLE VIEWSTATIONS AND RECORDERS

Figure 9. System Connections

Page 21 of the Pelco DX9100 user manual — POWER UP THE EQUIPMENT
Pagina 21 · klik om te vergroten
Pagina 21

POWER UP THE EQUIPMENT

Follow these steps after you make all connections:

1. Turn on the storage units and let them run for at least one minute (the hard disk drives must spin through their warm-up cycle).
2. Turn on the recorder and let it boot for at least 30 seconds.
3. Turn on the viewstation.

The recorder applications start automatically. There are four applications that should be running in order for the recorder to work.

  • SQL Server Service Manager (
  • appears in system tray)
  • Server Attendant
  • Recording Server
  • Time Synchronizer (

appears in system tray)

The pcAnywhere™ application is preinstalled on all recorders and viewstations. You can use this application to access remote recorders or viewstations.

Page 22 of the Pelco DX9100 user manual — VIEWSTATION NETWORK CONFIGURATION
Pagina 22 · klik om te vergroten
Pagina 22

PROGRAMMING

VIEWSTATION NETWORK CONFIGURATION

After you make all connections, you have to configure the viewstation to work on the network. To configure the viewstation, you need the following information. You can obtain this information from your network administrator.

  • Unique viewstation name: (Examples are Pelcovs1, Pelcovs2, Pelcovs3, etc. This is the default naming scheme.)
  • Unique IP address: (Examples are 100.0.0.201, 100.0.0.202, 100.0.0.203, etc. This is the default addressing scheme.) Each viewstation is identified by a logical IP address over a local area network (LAN). Each requires a unique IP address for communication using TCP/IP protocol. The IP address identifies a system’s location on the network and must be globally unique and have a uniform format.
  • Network subnet mask: This must be the same on all recorders and viewstations. (For example, 255.0.0.0 is the default.)
  • Computer workgroup name: This must be the same on all recorders and viewstations. (For example, DX9000_GROUP is the default.)
Page 23 of the Pelco DX9100 user manual — CHANGING THE VIEWSTATION’S IDENTIFICATION
Pagina 23 · klik om te vergroten
Pagina 23

CHANGING THE VIEWSTATION’S IDENTIFICATION

To change the default computer name or workgroup:

1. Close all windows on the viewstation desktop. 2. Right-click My Computer and then go to Properties. 3. Click the Network Identification tab. The following page appears.
Pelco DX9100 — CHANGING THE VIEWSTATION’S IDENTIFICATION diagram (page 23)
Afb. 10

Figure 10. Viewstation Network Identification Page

4. Click Properties. The following dialog box appears.
Pelco DX9100 — CHANGING THE VIEWSTATION’S IDENTIFICATION diagram (page 23)
Afb. 11

Figure 11. Viewstation Identification Changes Dialog Box

5. Enter the new computer name or workgroup. 6. Click OK. 7. Restart.
Page 24 of the Pelco DX9100 user manual — CHANGING THE VIEWSTATION’S IP ADDRESS AND SUBNET MASK
Pagina 24 · klik om te vergroten
Pagina 24

CHANGING THE VIEWSTATION’S IP ADDRESS AND SUBNET MASK

To change the viewstation’s IP address:

1. Close all windows on the viewstation desktop.
2. Right-click My Network Places and then go to Properties. The following window appears.
Pelco DX9100 — CHANGING THE VIEWSTATION’S IP ADDRESS AND SUBNET MASK diagram (page 24)
Afb. 12

Figure 12. Viewstation Network Connections Window

3. Double-click Local Area Connection. The following dialog box appears.
Pelco DX9100 — CHANGING THE VIEWSTATION’S IP ADDRESS AND SUBNET MASK diagram (page 24)
Afb. 13

Figure 13. Viewstation Local Area Connection Status Dialog Box

Page 25 of the Pelco DX9100 user manual — CHANGING THE VIEWSTATION’S IP ADDRESS AND SUBNET MASK
Pagina 25 · klik om te vergroten
Pagina 25
4. Click Properties. The following dialog box appears.
Pelco DX9100 — CHANGING THE VIEWSTATION’S IP ADDRESS AND SUBNET MASK diagram (page 25)
Afb. 14

Figure 14. Viewstation Local Area Connection Properties Dialog Box

5. Make sure the “Show icon in taskbar when connected” checkbox is selected.
6. Double-click Internet Protocol (TCP/IP). The following dialog box appears.
Pelco DX9100 — CHANGING THE VIEWSTATION’S IP ADDRESS AND SUBNET MASK diagram (page 25)
Afb. 15

Figure 15. Viewstation Internet Protocol (TCP/IP) Properties Dialog Box

7. Enter the IP address (for example, 100.0.0.201). The last three digits must be different for each viewstation (for example, 201, 202, 203, etc.).
8. Enter the subnet mask.
9. Click OK, close all windows, and then restart the viewstation.
Page 26 of the Pelco DX9100 user manual — CHANGING THE RECORDER’S IDENTIFICATION
Pagina 26 · klik om te vergroten
Pagina 26

CHANGING THE RECORDER’S IDENTIFICATION

The recorder name has been preset during manufacturing. The default name is Pelco1. Changing the recorder’s name should be done through the Server Identification dialog box only.

1. Close all applications on the recorder. 2. Double-click the DX9000 Server Configuration Utility icon on the desktop. The following dialog box appears.
Pelco DX9100 — CHANGING THE RECORDER’S IDENTIFICATION diagram (page 26)
Afb. 16

Figure 16. Server Configuration Utility Dialog Box

3. Click Server Identification. The following dialog box appears.
Pelco DX9100 — CHANGING THE RECORDER’S IDENTIFICATION diagram (page 26)
Afb. 17

Figure 17. Server Identification Dialog Box

4. Enter the new computer name.
5. Enter the new IP address. Make sure the network cable is plugged in before changing the IP address. 6. Click Apply. 7. Click OK to restart the system. 8. Repeat steps 1-7 for all recorders.
Page 27 of the Pelco DX9100 user manual — TIME SYNCHRONIZATION
Pagina 27 · klik om te vergroten
Pagina 27

TIME SYNCHRONIZATION

All equipment in your system must have the same time. Pelco recommends you select all recorders as time synchronization recorders. Creating this chain ensures that the system will maintain the correct time in case one or more recorders fail. All recorders and viewstations must belong to the same workgroup or local area network (LAN).

Follow these steps for each recorder and each viewstation:

1. Close all applications on the recorder and viewstation. 2. Make sure that the recorder and viewstation are connected to the network switch.
3. Right-click

in the system tray of each unit and select Exit.

4. Make sure the Date/Time Properties are correct on the recorder. You can access the date and time from the system tray.
Page 28 of the Pelco DX9100 user manual — SETTING DATE/TIME PROPERTIES
Pagina 28 · klik om te vergroten
Pagina 28

SETTING DATE/TIME PROPERTIES

Follow these steps to set the Date/Time Properties on the recorder and the viewstation. Make sure you close all applications on the recorder and viewstation.

1. Double-click the time on the system tray. The following page appears.
Pelco DX9100 — SETTING DATE/TIME PROPERTIES diagram (page 28)
Afb. 18

Figure 18. Date & Time Page

2. Set the date and time and then click Apply.
3. Click Time Zone. The following page appears.
Pelco DX9100 — SETTING DATE/TIME PROPERTIES diagram (page 28)
Afb. 19

Figure 19. Time Zone Page

4. Select your time zone from the drop-down box. The default is (GMT -08:00) Pacific Time (US & Canada); Tijuana.
5. Make sure that the “Automatically adjust clock for daylight saving changes” checkbox is selected, if applicable for the location of installation.
6. Click Apply and then OK.
Page 29 of the Pelco DX9100 user manual — CLIENT CONFIGURATION UTILITY
Pagina 29 · klik om te vergroten
Pagina 29

CLIENT CONFIGURATION UTILITY

You can do the following with this utility:

  • Synchronize the time between the recorder and the viewstation
  • Identify all the recorders that interface with the viewstation
  • Set the Daylight Saving Time for the viewstation
  • Import and export the server chain list
  • Build a list of local servers
1. Go to Start > Programs > DX9000 Viewstation > Client Configuration Utility. The following dialog box appears.
Pelco DX9100 — CLIENT CONFIGURATION UTILITY diagram (page 29)
Afb. 20

Figure 20. Client Configuration Login Dialog Box

2. Enter your “User name” and Password.
3. Click Login. The following dialog box appears.
Pelco DX9100 — CLIENT CONFIGURATION UTILITY diagram (page 29)
Afb. 21

Figure 21. Client Configuration Utility

4. Select “Build a list of local servers.”
Page 30 of the Pelco DX9100 user manual — CLIENT CONFIGURATION UTILITY
Pagina 30 · klik om te vergroten
Pagina 30
5. Select “Standard naming” or “Custom naming.”

a. Standard naming: Select this option if all recorders have the same name and the only difference is the numbers. For example, Pelco1, Pelco2, Pelco3.

b. Custom naming: If your recorders have different names, enter the names and then click Add.

6. Click Configure. The following dialog box appears.
Pelco DX9100 — CLIENT CONFIGURATION UTILITY diagram (page 30)
Afb. 22

Figure 22. Export to Server Dialog Box

7. Select “Export to server.”
8. Select the name of the first recorder from the drop-down box.
9. Click Configure.
10. Click Close.
11. Refer to Step 8 of the Recorder Initialization Options section to complete time synchronization.
Page 31 of the Pelco DX9100 user manual — RECORDER INITIALIZATION OPTIONS
Pagina 31 · klik om te vergroten
Pagina 31

RECORDER INITIALIZATION OPTIONS

To set the recorder initialization options, you must open the DX9000 Server Configuration Utility.

1. Double-click the DX9000 Server Configuration Utility icon on the desktop.
2. Set the “Frame rate & resolution” from the drop-down box. The default is CIF, Half, which is 15 ips at CIF resolution for DX9216H models and 30 ips at CIF resolution for DX9208F models.

The following figure shows the options for the DX9216H models.

Figure 23. DX9216H Frame Rate and Resolution

The following figure shows the options for the DX9208F models.

Pelco DX9100 — RECORDER INITIALIZATION OPTIONS diagram (page 31)
Afb. 23

Figure 24. DX9208F Frame Rate and Resolution

The number of channels is set automatically based on the frame rate and resolution you select. Click

for more information. The License Information dialog box displays important information about your license, such as the maximum allowed channels and the frame rates and resolutions that are allowed.

Pelco DX9100 — RECORDER INITIALIZATION OPTIONS diagram (page 31)
Afb. 24

Figure 25. License Information Dialog Box

3. Select PAL or NTSC as the recording format. The default is NTSC.
Page 32 of the Pelco DX9100 user manual — RECORDER INITIALIZATION OPTIONS
Pagina 32 · klik om te vergroten
Pagina 32
4. Enter the “Multicast group.” This number is based on the recorder’s IP address. For example, if the IP address is 100.0.0.101, then the multicast group number should be 239.0.0.101. The last three numbers should match.
5. Enter the Multicast TTL number (1-20). This is the number or routers, if any, which separate the recorder from its farthest viewstation on the network. If you do not know the number of routers, contact the network administrator.
6. Enter the “Alarm interval.” This is the time (in seconds) between alarms. No alarm will be triggered until the end of the specified interval. The default value is 300 seconds. The range is from 0 to 7,200.
7. Enter the “Pre-Alarm interval.” Set the number of seconds to record before the event. The default value is 60 seconds. The range is from 0 to 7,200.
8. Click Suggest to see a list of available recorders. This option is available only if you performed the “Export to server” procedures as described in the Client Configuration Utility. If not, enter the name of the recorders in the “Define time synchronization chain” box. The order of entry for the recorders must be entered identically on each recorder.
9. Select a recorder and then click Add to add it to the time synchronization chain.
10. Click Configure.
11. Restart all recorders and viewstations.
Page 33 of the Pelco DX9100 user manual — SERVER STATE
Pagina 33 · klik om te vergroten
Pagina 33

SERVER STATE

The Server State utility checks the status of the recorders that are connected to the viewstation. It verifies if a recorder is recording, not recording, or unreachable. The Server State application should be running in the background all the time.

1. Go to Start > Programs > DX9000 Viewstation > Server State.
Pelco DX9100 — SERVER STATE diagram (page 33)
Afb. 25

Figure 26. Server State

2. Select “All servers” to run the test on all recorders or “Server” to run the test on a specific recorder.
3. Click Configure.
Page 34 of the Pelco DX9100 user manual — SERVER STATE
Pagina 34 · klik om te vergroten
Pagina 34
Pelco DX9100 — SERVER STATE diagram (page 34)
Afb. 26

Figure 27. Configuration Options

4. Select the refresh interval. The recommended setting is 60 seconds. Any setting less than 60 seconds will become network intensive because the viewstation constantly polls the recorders.
5. Click OK.
6. Check the “Auto-refresh” checkbox. The application checks the refresh interval when you click start.
7. Check the “Alert on errors or warning” checkbox. The following message appears when an error occurs.
Pelco DX9100 — SERVER STATE diagram (page 34)
Afb. 27

Figure 28. Error Alert

8. Click Start. The following table explains the symbols that appear next to the server name.

Table A. Server State Symbols

Status is not known. The server has not been tested yet.

Test in progress. This arrow appears next to each server being tested.

The server is working.

Server alert. The error alert message above appears. The error results appear in the bottom right panel.

Alerts you to a server problem even thought the server is still recording.

Symbol Status

Page 35 of the Pelco DX9100 user manual — DATABASE BACKUP AND REPAIR
Pagina 35 · klik om te vergroten
Pagina 35

ADVANCED RECORDER OPTIONS

To set the advanced recorder options, you must open the DX9000 Server Configuration Utility. Double-click the DX9000 Server Configuration Utility icon on the desktop. The Server Configuration Utility dialog box appears with the Advanced Options section. Make sure you close all other desktop applications on the viewstation and recorder.

Pelco DX9100 — ADVANCED RECORDER OPTIONS diagram (page 35)
Afb. 28

Figure 29. Advanced Options

Delete existing info on database: Select the checkbox to restore the database to its initial state. Click Configure.

Assume continuous recording on Scheduler: Select the checkbox to employ continuous recording on the scheduler. Click Configure.

Delete custom settings from recorder server: Select the checkbox to restore the DVMD settings to the default settings. Click Configure.

Delete custom channel setup settings: Select the checkbox to restore the channel setup settings to the default settings. Click Configure.

DATABASE BACKUP AND REPAIR

This option backs up the database files to a backup folder, which it automatically creates in e:\databasebackups\. The system backs up the database automatically once a day.

You can also use this option to back up the database manually to the current time. This ensures you will not lose any information, such as camera titles, in case of system failure.

1. Double-click the DX9000 Server Configuration Utility icon on the desktop. 2. Click Repair and Backup Database. 3. Click OK.
Pelco DX9100 — DATABASE BACKUP AND REPAIR diagram (page 35)
Afb. 29

Figure 30. Database Backup and Repair Confirmation

Page 36 of the Pelco DX9100 user manual — DATABASE RESTORATION
Pagina 36 · klik om te vergroten
Pagina 36

DATABASE RESTORATION

The following procedure explains how to restore a database that has been backed up.

1. Close all recorder applications. 2. Go to the system tray.
Pelco DX9100 — DATABASE RESTORATION diagram (page 36)
Afb. 30

Figure 31. System Tray

3. Double-click the SQL server icon. The following window appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 36)
Afb. 31

Figure 32. Server Service Manager Window

4. Click Stop. The following dialog box appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 36)
Afb. 32

Figure 33. Stop SQL Dialog Box 1

5. Click Yes. The following dialog box appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 36)
Afb. 33

Figure 34. Stop SQL Dialog Box 2

Page 37 of the Pelco DX9100 user manual — DATABASE RESTORATION
Pagina 37 · klik om te vergroten
Pagina 37
6. Click Yes. Start/Continue is enabled after several seconds.
Pelco DX9100 — DATABASE RESTORATION diagram (page 37)
Afb. 34

Figure 35. Start/Continue Window

7. Exit the window. 8. Double-click the recorder name icon on your desktop. The following window appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 37)
Afb. 35

Figure 36. My Computer Window

Page 38 of the Pelco DX9100 user manual — DATABASE RESTORATION
Pagina 38 · klik om te vergroten
Pagina 38
9. Go to D:\Databases. The following window appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 38)
Afb. 36

Figure 37. Databases Window

10. Rename MSSQL to MSSQL_old.
Pelco DX9100 — DATABASE RESTORATION diagram (page 38)
Afb. 37

Figure 38. Rename MSSQL

Page 39 of the Pelco DX9100 user manual — DATABASE RESTORATION
Pagina 39 · klik om te vergroten
Pagina 39
11. Go to C:\Copy of D Drive\Databases. The following window appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 39)
Afb. 38

Figure 39. C Drive Databases Window

12. Copy the MSSQL folder and paste it to D:\Databases.
Pelco DX9100 — DATABASE RESTORATION diagram (page 39)
Afb. 39

Figure 40. MSSQL Folders

13. Delete MSSQL_old.
Page 40 of the Pelco DX9100 user manual — DATABASE RESTORATION
Pagina 40 · klik om te vergroten
Pagina 40
14. Double-click the SQL server icon. The following window appears.

Figure 41. Start/Continue Window

15. Select SQL Server Agent from the Services drop-down box. 16. Click Start/Continue. Stop is enabled and the status is Running after several seconds. 17. Select SQL Server from the Services drop-down box. 18. Exit the window. 19. Go to E:\DatabaseBackups. The following window appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 40)
Afb. 40

Figure 42. Database Backups Window

20. Select the most recent database backup file (Vigilant Server_db). 21. Double-click the recorder name icon on your desktop again, and then go to C:\AvServer\Config\avRestoreDBR2.
Page 41 of the Pelco DX9100 user manual — DATABASE RESTORATION
Pagina 41 · klik om te vergroten
Pagina 41
Pelco DX9100 — DATABASE RESTORATION diagram (page 41)
Afb. 41

Figure 43. Explorer Windows

22. Drag the database backup file to C:\AvServer\Config\avRestoreDBR2. The following dialog box appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 41)
Afb. 42

Figure 44. Restore Utility Dialog Box

23. Go to the system tray.

Figure 45. System Tray

Page 42 of the Pelco DX9100 user manual — DATABASE RESTORATION
Pagina 42 · klik om te vergroten
Pagina 42
24. Double-click the SQL server icon. The following window appears.

Figure 46. Server Service Manager Window

25. Click Stop. The following dialog box appears.

Figure 47. Stop SQL Dialog Box 1

26. Click Yes. The following dialog box appears

Figure 48. Stop SQL Dialog Box 2

27. Click Yes. Start/Continue is enabled after several seconds.

Figure 49. Start/Continue Window

Page 43 of the Pelco DX9100 user manual — DATABASE RESTORATION
Pagina 43 · klik om te vergroten
Pagina 43
28. Select SQL Server Agent from the Services drop-down box. 29. Click Start/Continue. Stop is enabled and the status is Running after several seconds. 30. Select SQL Server from the Services drop-down box. 31. Exit the window.
Pelco DX9100 — DATABASE RESTORATION diagram (page 43)
Afb. 43

Figure 50. Replace Database Dialog Box

32. Click OK. The following dialog box appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 43)
Afb. 44

Figure 51. Restore Confirmation Dialog Box

33. Click OK to restore from the selected backup file. The following dialog box appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 43)
Afb. 45

Figure 52. Operation Completed Dialog Box

34. Click OK and restart the recorder. 35. Close all recorder applications. 36. Go to C:\AvServer\Config, and then double-click Maintenance. The following dialog box appears.
Pelco DX9100 — DATABASE RESTORATION diagram (page 43)
Afb. 46

Figure 53. Maintenance Dialog Box

37. Enter the name of the desired recorder. The default is the local recorder name. 38. Click Find. The utility counts the number of files on the disk that do not have corresponding records in the database and the number of records in the database that do not have corresponding files.
Page 44 of the Pelco DX9100 user manual — DATABASE RESTORATION
Pagina 44 · klik om te vergroten
Pagina 44
Pelco DX9100 — DATABASE RESTORATION diagram (page 44)
Afb. 47

Figure 54. Finished Scan Dialog Box

39. Select “Merge files not found on Database” to create new records on the database for the video files that were detected. 40. Select “Delete database records not found on Disk” to delete records on the database that do not have any video files. 41. Click Normalize to merge files and delete records. “Finished Merging” appears at the bottom of the window when the process is complete.
Pelco DX9100 — DATABASE RESTORATION diagram (page 44)
Afb. 48

Figure 55. Finished Merging Dialog Box

42. Click Close. 43. Restart the recorder.
Page 45 of the Pelco DX9100 user manual — RAID MANAGER GATEWAY CONFIGURATION
Pagina 45 · klik om te vergroten
Pagina 45

RAID MANAGER UTILITY

The Raid Manager Utility is preinstalled and preprogrammed on all DX9200 recorders and all DX9100 viewstations prior to shipping. The application monitors the health of the DX9200HDDI external hard drive storage unit and provides alarm notification if there is a malfunction. If you have changed recorder names and IP addresses, changed viewstation IP addresses, or added/removed recorders to the system, you must update this utility with the same information. This ensures compatibility and proper operation of the application.

The recorders have a program called the Raid Manager Server that serves as a logical recorder to obtain information from Raid subsystems via a COM, SCSI, or fiber connection.

The viewstations have a program called the Raid Manager Gateway that serves as a data center and gathers information from all Raid Manager recorders so that an administrator can monitor these recorders through a web browser.

DISABLING THE RAID MANAGER GATEWAY

You can have only one viewstation running the Raid Manager Gateway application on a network. You must disable the Raid Manager Gateway on the other viewstations.

To disable the Raid Manager Gateway:

1. Right-click

on the system tray. 2. Select “Remove from Windows Startup.” 3. Go to Start > Programs > Raid Manager Utility and then right-click to show the properties. 4. Select Delete. 5. Restart the viewstation. The icon and programs are no longer available.

RAID MANAGER GATEWAY CONFIGURATION

The Raid Manager Gateway Configuration window shows the main root, the default group (DX9000_GROUP), and the default recorder name (Pelco1). The default IP address of the recorder is 100.0.0.101.

To edit the default recorder name and IP address:

1. Go to your viewstation desktop and make sure the Raid Manager Gateway icon is in the system tray. 2. Go to Start > Programs > Raid Manager Utility > Raid Manager Gateway > Raid Manager Gateway Config. The following window appears.
Pelco DX9100 — RAID MANAGER GATEWAY CONFIGURATION diagram (page 45)
Afb. 49

Figure 56. Raid Manager Gateway Configuration Window

Page 46 of the Pelco DX9100 user manual — RAID MANAGER UTILITY
Pagina 46 · klik om te vergroten
Pagina 46
3. Select Pelco1 and then click Edit Server. The following window appears.
Pelco DX9100 — RAID MANAGER UTILITY diagram (page 46)
Afb. 50

Figure 57. Default Server Information Window

4. Enter the new recorder name and IP address. The following example shows the recorder name Orangeburg and the IP address 100.0.0.110.
Pelco DX9100 — RAID MANAGER UTILITY diagram (page 46)
Afb. 51

Figure 58. Edit Server Window

5. Click OK. The new recorder name appears.

To add a new recorder to the group:

1. Select DX9000_GROUP. 2. Click Add Server. The following window appears.
Pelco DX9100 — RAID MANAGER UTILITY diagram (page 46)
Afb. 52

Figure 59. Add Server Window

3. Enter the recorder name and IP address and then click OK. The added recorder appears under the selected group.

To delete a recorder:

1. Select a recorder. 2. Click Delete Server.
Page 47 of the Pelco DX9100 user manual — RAID MANAGER UTILITY
Pagina 47 · klik om te vergroten
Pagina 47

To edit the group:

1. Select DX9000_GROUP. 2. Click Edit Group. The following window appears.
Pelco DX9100 — RAID MANAGER UTILITY diagram (page 47)
Afb. 53

Figure 60. Edit Group Window

3. Enter the new Group Name and then click OK. The new group name appears under ROOT.

You can add a new group for systems located remotely. To add a new group:

1. Select ROOT. 2. Click Add Group. The following window appears.
Pelco DX9100 — RAID MANAGER UTILITY diagram (page 47)
Afb. 54

Figure 61. Add Group Window

3. Enter the Group Name and then click OK. The added group appears under ROOT.

To delete a group:

1. Select a group. 2. Click Delete Group.
Page 48 of the Pelco DX9100 user manual — Event Notification
Pagina 48 · klik om te vergroten
Pagina 48

GATEWAY CONFIGURATION SETTINGS

You must set up the events on the Event Notification page. In case of failure, these settings will send a default error message to the viewstation, regardless if the Raid Manager application is open or closed.

In the NetSend Setting page, you must enter the IP addresses of all viewstations on the network.

Event Notification

1. Select Setting on the Raid Manager Configuration Window. The Event Notification page appears.
Pelco DX9100 — Event Notification diagram (page 48)
Afb. 55 · Event Notification

Figure 62. Event Notification Page

2. Make sure the “Add Events to EventLog” checkbox is selected. This is the default setting. 3. Make sure all checkboxes in the “Event Notify in case of” section are selected. This is the default setting. 4. Click OK.
Page 49 of the Pelco DX9100 user manual — Netsend Setting
Pagina 49 · klik om te vergroten
Pagina 49

Netsend Setting

1. Click the NetSend Setting tab. The following page appears.
Pelco DX9100 — Netsend Setting diagram (page 49)
Afb. 56 · Netsend Setting

Figure 63. NetSend Setting Page

2. Make sure the NetSend Notify checkbox is selected to activate the net send notification. This is the default setting. 3. Enter the IP address of the additional viewstations. 4. Click Add. 5. Click OK. 6. Restart the viewstation.
Page 50 of the Pelco DX9100 user manual — VIEWSTATION IP ADDRESS
Pagina 50 · klik om te vergroten
Pagina 50

VIEWSTATION IP ADDRESS

If you change the IP address on the viewstation, you must follow these steps to make sure the Raid Manager Gateway works properly:

1. Right-click the Internet Explorer icon on your viewstation desktop. 2. Select Properties. The following window appears.
Pelco DX9100 — VIEWSTATION IP ADDRESS diagram (page 50)
Afb. 57

Figure 64. Internet Properties Window

3. Replace the viewstation IP address in the Address box and then click OK. Do not delete /html/index_win.htm . 4. Double-click My Computer > Control Panel > Administrative Tools > Internet Services Manager. The following window appears.
Pelco DX9100 — VIEWSTATION IP ADDRESS diagram (page 50)
Afb. 58

Figure 65. Internet Information Services Window

Page 51 of the Pelco DX9100 user manual — VIEWSTATION IP ADDRESS
Pagina 51 · klik om te vergroten
Pagina 51
5. Double-click the viewstation name under the Internet Information Services tree. 6. Right-click Default Web Site and then select Properties. The following window appears.
Pelco DX9100 — VIEWSTATION IP ADDRESS diagram (page 51)
Afb. 59

Figure 66. Default Web Site Properties

7. Enter the viewstation’s IP address in the IP Address box. 8. Click Apply. 9. Click OK.
Page 52 of the Pelco DX9100 user manual — RAID MANAGER HOME PAGE
Pagina 52 · klik om te vergroten
Pagina 52

RAID MANAGER HOME PAGE

After you configure the Raid Manager Gateway, you must go to your web browser.

1. Double-click the Internet Explorer icon on your viewstation desktop. Internet Explorer opens and the Raid Manager home page appears.
Pelco DX9100 — RAID MANAGER HOME PAGE diagram (page 52)
Afb. 60

Figure 67. Raid Manager Home Page

2. Verify that the recorder names you added or edited are correct. 3. Select the desired recorder.
Page 53 of the Pelco DX9100 user manual — RAID MANAGER HOME PAGE
Pagina 53 · klik om te vergroten
Pagina 53
4. Double-click the name and serial number information. The storage information window appears.
Pelco DX9100 — RAID MANAGER HOME PAGE diagram (page 53)
Afb. 61

Figure 68. Storage Information Window

5. Click Controller Information to see the unit type and details. The following window is an example.
Pelco DX9100 — RAID MANAGER HOME PAGE diagram (page 53)
Afb. 62

Figure 69. Controller Information Window

The Raid Manager main screen is divided into three plates:

  • Disk Information Plate
  • Host & RAID Information Plate
  • Status Plate
Page 54 of the Pelco DX9100 user manual — DISK INFORMATION PLATE
Pagina 54 · klik om te vergroten
Pagina 54

DISK INFORMATION PLATE

This screen shows you the status for each of your disks. The disk status appears on each icon. Refer to Table B.

Table B. Disk Status

No hard drive is installed in the disk slot.

The hard drive is online and configured.

Rebuilding the newly replaced drive.

The hard drive in the disk slot is a spare.

Hard drive failure.

Double-click each icon to see its configuration. The following screenshot shows the disk information of a hard drive that is not installed.

Pelco DX9100 — DISK INFORMATION PLATE diagram (page 54)
Afb. 63

Figure 70. No Hard Drive Information

Icon Description

Page 55 of the Pelco DX9100 user manual — DISK INFORMATION PLATE
Pagina 55 · klik om te vergroten
Pagina 55

The following screenshot shows the disk information of a hard drive that is online and configured.

Pelco DX9100 — DISK INFORMATION PLATE diagram (page 55)
Afb. 64

Figure 71. Configured Hard Drive Information

The following screenshot shows the disk information of a hard drive that is rebuilding the newly replaced drive.

Pelco DX9100 — DISK INFORMATION PLATE diagram (page 55)
Afb. 65

Figure 72. Newly Replaced Hard Drive Information

The following screenshot shows the disk information of a hard drive that is a spare.

Pelco DX9100 — DISK INFORMATION PLATE diagram (page 55)
Afb. 66

Figure 73. Spare Hard Drive Information

Page 56 of the Pelco DX9100 user manual — HOST AND RAID INFORMATION PLATE
Pagina 56 · klik om te vergroten
Pagina 56

HOST AND RAID INFORMATION PLATE

This screen shows you the host and raid configuration. You can see the connections between the Lun and Slice on each array.

This screen has three columns:

  • Host 1 Interface
  • Raid Information
  • Host 2 Interface
Pelco DX9100 — HOST AND RAID INFORMATION PLATE diagram (page 56)
Afb. 67

Figure 74. Host & Raid Information Screen

To see the information for each column:

1. Click the Host 1 Interface Detail button to see the host information.
Pelco DX9100 — HOST AND RAID INFORMATION PLATE diagram (page 56)
Afb. 68

Figure 75. Host 1 Interface Details

2. Click the Raid Information Detail button to see the array information.
Page 57 of the Pelco DX9100 user manual — STATUS PLATE
Pagina 57 · klik om te vergroten
Pagina 57
Pelco DX9100 — STATUS PLATE diagram (page 57)
Afb. 69

Figure 76. RAID Information Details

3. Click the Host 2 Interface Detail button to see the host information.
Pelco DX9100 — STATUS PLATE diagram (page 57)
Afb. 70

Figure 77. Host 2 Interface Details

4. Move the cursor on the Slice or Lun column to see their logical connection on each array.

STATUS PLATE

The status plate has four indicators for the raid unit:

  • Fan
  • Temp
  • Power
  • UPS
Pelco DX9100 — STATUS PLATE diagram (page 57)
Afb. 71

Figure 78. Status Plate

The status plate lets you know whether the fan, temperature, and power are working. In case of failure, the indicator changes from working to failed. The UPS indicator shows if the UPS is off or on.

Page 58 of the Pelco DX9100 user manual — CAMERA RECORDING PROPERTIES
Pagina 58 · klik om te vergroten
Pagina 58

CAMERA RECORDING PROPERTIES

Camera recording properties should be set by the system administrator during installation. Only system administrators and operators with a Level 1 authorization can set or change camera recording properties. To set or change camera recording properties, you must open the DX9000 Viewstation application. The System button on the main toolbar is not available to Level 2-6 operators. If you do not have access, see the system administrator.

To set or change camera recording properties:

1. Click System > Properties on the main toolbar. The following window appears.
Pelco DX9100 — CAMERA RECORDING PROPERTIES diagram (page 58)
Afb. 72

Figure 79. Camera Properties Dialog Box

Page 59 of the Pelco DX9100 user manual — CAMERA RECORDING PROPERTIES
Pagina 59 · klik om te vergroten
Pagina 59
2. Click “Select channel” to display a list of recorders. An example is shown below.
Pelco DX9100 — CAMERA RECORDING PROPERTIES diagram (page 59)
Afb. 73

Figure 80. Select Channel Dialog Box

3. Select a channel.
4. Select the Preview checkbox, as shown below, to verify that you have the correct camera.
Pelco DX9100 — CAMERA RECORDING PROPERTIES diagram (page 59)
Afb. 74

Figure 81. Continuous Recording Schedule Page

Page 60 of the Pelco DX9100 user manual — DAILY RECORDING SCHEDULE
Pagina 60 · klik om te vergroten
Pagina 60

CONTINUOUS RECORDING SCHEDULE

1. Select the “Continuous recording” radio button. (This is the default setting and should already be selected the first time you select a channel.) Refer to Figure 81.
2. Click Apply.

Recording is done at all times and no schedule is defined. The entire daily and weekly recording schedules are marked in light yellow, and any previous definitions on the schedules are removed.

DAILY RECORDING SCHEDULE

1. Select the “Daily recording schedule” radio button. 2. Click Continuous or “Event record.” 3. In the time bar, click the desired start/end times for recording, or enter the exact start/end times in the “Fine tune” fields. 4. Click Apply.

The example below shows a Continuous daily recording schedule from 7:05 a.m. to 12:05 p.m. The box in the time bar is blue with a red border. You can make the box smaller or larger by dragging it with your mouse.

Pelco DX9100 — DAILY RECORDING SCHEDULE diagram (page 60)
Afb. 75

Figure 82. Continuous Daily Recording Schedule Page

Page 61 of the Pelco DX9100 user manual — CONTINUOUS RECORDING SCHEDULE
Pagina 61 · klik om te vergroten
Pagina 61

The example below shows a daily Event record schedule from 7:05 a.m. to 12:05 p.m. The box in the time bar is yellow with a red border. You can make the box smaller or larger by dragging it using your mouse.

Pelco DX9100 — CONTINUOUS RECORDING SCHEDULE diagram (page 61)
Afb. 76

Figure 83. Daily Event Recording Page

If you select event recording, the DX9200 actually records continuously. The difference between continuous and event recording is the way the video is saved in the database. When the hard drives are full, the DX9100 starts overwriting the oldest video. With continuous recording, the DX9200 overwrites the video in the order in which it was recorded, whether it is an event or a nonevent. With event recording, the DX9200 overwrites nonevents first and then events. Data is overwritten on a day-to-day basis.

To delete a time period:

1. Click “No record.” 2. Click the box in the time bar.
Page 62 of the Pelco DX9100 user manual — WEEKLY RECORDING SCHEDULE
Pagina 62 · klik om te vergroten
Pagina 62

WEEKLY RECORDING SCHEDULE

1. Select the “Weekly recording schedule” radio button.
2. Click Continuous or “Event record.”
3. In the time bars, click the desired start/end times for recording for each day of the week, or enter the exact start/end times in the “Fine tune” fields.
4. Click Apply.

The example below shows a Continuous weekly recording schedule from 7:05 a.m. to 12:05 p.m. The boxes in the time bars are blue with a red border. You can make the boxes smaller or larger by dragging them with your mouse.

Pelco DX9100 — WEEKLY RECORDING SCHEDULE diagram (page 62)
Afb. 77

Figure 84. Continuous Weekly Recording Schedule Page

The example below shows a weekly Event record schedule from 7:05 a.m. to 12:05 p.m. The boxes in the time bars are yellow with a red border. You can make the boxes smaller or larger by dragging them with your mouse.

Pelco DX9100 — WEEKLY RECORDING SCHEDULE diagram (page 62)
Afb. 78

Figure 85. Weekly Event Recording Schedule Page

To delete a time period:

1. Click “No record.” 2. Click the boxes in the time bars.
Page 63 of the Pelco DX9100 user manual — MOTION DETECTION
Pagina 63 · klik om te vergroten
Pagina 63

MOTION DETECTION

1. Click the DVMD tab. The DVMD page appears. Refer to Figure 86.
2. Select the “Detector on” radio button.
3. Select the Preview checkbox. The video has blue squares over the entire area meaning the entire video has been selected for motion detection.
4. Click “Clear all” to remove all of the boxes or click the right mouse button on each box you want to remove.
5. Click “Mark all” to select the entire video for motion detection or click the left mouse button to add individual boxes.
6. Click “Discard changes” to undo your changes.
7. Drag the triangles on the slider bars to select the minimum time between events and the video motion detection (VMD) sensitivity.
8. Click Apply.
Pelco DX9100 — MOTION DETECTION diagram (page 63)
Afb. 79

Figure 86. Motion Detection Page

Page 64 of the Pelco DX9100 user manual — CHANNEL SETUP
Pagina 64 · klik om te vergroten
Pagina 64

CHANNEL SETUP

This section describes how to set camera properties to get the best picture.

1. Click the Video tab. The Video page appears. Refer to Figure 87. 2. Select the Preview checkbox to see the video quality with the default settings. 3. Adjust the video quality by dragging the triangles on the slider bars to the desired values. Refer to Table C. 4. Click Apply.
Pelco DX9100 — CHANNEL SETUP diagram (page 64)
Afb. 80

Figure 87. Camera Video Setup Page

Page 65 of the Pelco DX9100 user manual — CHANNEL SETUP
Pagina 65 · klik om te vergroten
Pagina 65

Table C. Channel Setup

Channel Name Enter a new name for this channel. You can enter up to 20 characters.

Brightness Drag the triangle to change the brightness value. The higher the value, the higher the bit rate. The previous value is displayed to the right of the brightness bar.

Contrast Drag the triangle to change the contrast value. The higher the value, the higher the bit rate. The previous value is displayed to the right of the contrast bar.

Hue Drag the triangle to change the hue value. The previous value is displayed to the right of the hue bar.

Sat V Drag the triangle to increase or decrease the red color in the video. The previous value is displayed to the right of the Sat V bar.

Sat U Drag the triangle to increase or decrease the blue color in the video. The previous value is displayed to the right of the Sat U bar.

Vertical This reduces or eliminates video noise. The higher the value, the lower the bit rate. The lower the value, the higher the bit rate.

Horizontal This reduces or eliminates video noise. The higher the value, the lower the bit rate. The lower the value, the higher the bit rate.

Black/White Select this checkbox if the channel is connected to a black/white camera. This option ignores video noise.

White Crush Select this checkbox to reduce the intensity of the white images.

Parameter Description/Action

Page 66 of the Pelco DX9100 user manual — DEFINING USERS
Pagina 66 · klik om te vergroten
Pagina 66

DEFINING USERS

Only system administrators can define user names and passwords for the DX9100 Viewstation. Other users trying to access this option will get the following message:

Pelco DX9100 — DEFINING USERS diagram (page 66)
Afb. 81

Figure 88. User Access Dialog Box

This option allows an administrator to add, delete, and change the properties of users in the DX9200 system. There are seven predefined user access levels ranging from Administrator to Operator Level 6. Each user is assigned different access rights to the DX9200 network and videos.

Click System > Users on the main toolbar. In the example below, each operator level has been assigned a user name and password.

Pelco DX9100 — DEFINING USERS diagram (page 66)
Afb. 82

Figure 89. User Manager Dialog Box

Page 67 of the Pelco DX9100 user manual — Deleting a User
Pagina 67 · klik om te vergroten
Pagina 67

Table D. User Access Rights

Video Locked Export Unlock Video/ Define Live Video/ Playback/ Video Lock Image/ Change Camera Users/Audit User Live Events Query/Sherlock Playback Video Video Settings Viewer

Administrator ✓

Operator Level 1 ✓

Operator Level 2 ✓

Operator Level 3 ✓

Operator Level 4 ✓ ✓ ✓

Operator Level 5 ✓ ✓

Operator Level 6 ✓

Edit Existing Users

1. Select the server name from the “Filter per server” drop-down box. A list of users defined for the selected server appears under the Users List.
2. Select a user. The user’s properties appear in the Properties panel.
3. Select a new operator authorization level.
4. Select the server name from the “Accessible servers list.”
5. Click OK.

Adding a New User

1. Click New. 2. Enter the user name. This is the login user name. 3. Enter the user’s full name. 4. Enter the user’s password. This is the login password. 5. Reenter the same password. 6. Select the user’s authorization level: administrator or operator. 7. Highlight the server the user should have access to from the “Accessible servers list.” 8. Click OK.

Deleting a User

1. Select the user name from the “Users list.” 2. Select the server name from the “Accessible servers list.” 3. Click the left arrow button. 4. Click OK.
Page 68 of the Pelco DX9100 user manual — I/O MANAGER
Pagina 68 · klik om te vergroten
Pagina 68

ADVANCED FEATURES

I/O INTERFACE

The DX9200 system can interface with the CM6800, CM9740, or CM9760 matrix switchers. It can integrate with the CM9760-DT, CM9760-ALM, and CM9760-REL.

  • CM9760-DT data translator translates the ASCII protocol to the P protocol of the CM9740/CM9760 matrix switchers.
  • Connect up to four CM9760-ALM alarm units to each DX9200 recorder.
  • Connect up to four CM9760-REL relay units to each DX9200 recorder.

I/O HANDLER

This application allows the installer to identify one additional external device—the CM9760 data translator, the CM9760-ALM alarm unit, or the CM9760-REL relay unit—to be connected to the COM port on the recorder. Each of the external devices can be shared across multiple recorders, but when programming to external devices, the programming only needs to be done on the recorder which is physically attached to the device.

I/O MANAGER

This application is used in conjunction with the I/O Handler to interface to:

  • the CM9760-ALM
  • the CM9760-REL
  • the CM9760-DT

Since these devices can be shared across multiple recorders across the network, the installer can identify alarm inputs 1-16 for recorder #1, alarm inputs 17-32 for recorder #2, and so on.

Page 69 of the Pelco DX9100 user manual — RECORDER
Pagina 69 · klik om te vergroten
Pagina 69

CONNECTING AN ALARM UNIT

You can connect a maximum of four alarm units to a recorder.

To connect a CM9760-ALM to a DX9200 recorder using RS-232 communication:

1. Connect a null modem cable from the alarm unit’s RS-232 port to the recorder’s COM 1 or COM 2 port.
2. Set the DIP switches on the alarm unit for RS-232 communication. Refer to the CM9760-ALM Installation/Operation manual.

If using RS-422 communication:

1. Connect a cable from the alarm unit’s RJ-45 COM IN port to the recorder’s COM 1 or COM 2 port via an RS-232 to RS-422 converter.
2. Set the DIP switches on the alarm unit for RS-422 communication. Refer to the CM9760-ALM Installation/Operation manual.

RECORDER

Pelco DX9100 — RECORDER diagram (page 69)
Afb. 83

Figure 90. Connecting a CM9760-ALM

Page 70 of the Pelco DX9100 user manual — ALARM UNIT CONFIGURATION
Pagina 70 · klik om te vergroten
Pagina 70

ALARM UNIT CONFIGURATION

Follow these steps to configure a CM9760-ALM alarm unit.

1. Go to Start > Programs > DX9000 Server > IO Handler Configuration. The following dialog box appears.
Pelco DX9100 — ALARM UNIT CONFIGURATION diagram (page 70)
Afb. 84

Figure 91. Alarm I/O Handler Configuration Dialog Box

2. Click Select Driver on Device 1 (COM 1) or Device 2 (COM 2) to define the external device that is connected to the recorder. The following dialog box appears.
Pelco DX9100 — ALARM UNIT CONFIGURATION diagram (page 70)
Afb. 85

Figure 92. CM9760 Alarm Driver Dialog Box

3. Select CM9760ALM.dll.
Page 71 of the Pelco DX9100 user manual — ALARM UNIT CONFIGURATION
Pagina 71 · klik om te vergroten
Pagina 71
4. Click Open. The following dialog box appears.
Pelco DX9100 — ALARM UNIT CONFIGURATION diagram (page 71)
Afb. 86

Figure 93. Device 2 Alarm Driver Dialog Box

5. Click Configure. The following dialog box appears.
Pelco DX9100 — ALARM UNIT CONFIGURATION diagram (page 71)
Afb. 87

Figure 94. CM9760 Alarm Configuration Dialog Box

6. Set the baud rate to 4800. The alarm unit should have this same baud rate.
7. Enter 1 or 2 in the COM Port field. This is the physical port on the recorder that connects to the alarm unit.
8. Set the default interval. This is the time interval between two events and sets the same time interval for all of the alarm ports. The default is 60 seconds.
9. Set the armed alarms. If the recorder is connected to two alarms units, you should have a range of 0-127 because each alarm has 64 ports. The default range is 0-63.
10. Add intervals for specific alarms. Figure 94 shows five different intervals for five different alarms.
11. Click OK.
12. Click Test.
13. Close the I/O Handler Configuration application.
Page 72 of the Pelco DX9100 user manual — I/O Manager for Alarm Unit
Pagina 72 · klik om te vergroten
Pagina 72

I/O Manager for Alarm Unit

1. Go to Start > Programs > DX9000 Server > IO Manager Configuration. The Overview dialog box appears.
2. Click Next. The following dialog box appears.
Pelco DX9100 — I/O Manager for Alarm Unit diagram (page 72)
Afb. 88 · I/O Manager for Alarm Unit

Figure 95. Dialog Box to Configure External 1 Source

3. Select the channel or channels that will receive events from the alarm unit.
4. Enter the server name that the alarm unit is connected to.
5. Select the device as configured in the I/O Handler. This is the logical device number that the alarm unit is connected to.
6. Enter the alarm port number that the selected channel will receive events from. If several channels are selected, this number specifies the related port of the first channel. For example, if eight channels are selected, port 0 relates to channel 0 and so on.
Page 73 of the Pelco DX9100 user manual — I/O Manager for Alarm Unit
Pagina 73 · klik om te vergroten
Pagina 73
7. Click OK. The information you entered appears on the screen, as shown in Figure 96.
Pelco DX9100 — I/O Manager for Alarm Unit diagram (page 73)
Afb. 89 · I/O Manager for Alarm Unit

Figure 96. Sample Configuration for External 1 Source

Page 74 of the Pelco DX9100 user manual — I/O Manager for Alarm Unit
Pagina 74 · klik om te vergroten
Pagina 74
8. Click Next. The following dialog box appears.
Pelco DX9100 — I/O Manager for Alarm Unit diagram (page 74)
Afb. 90 · I/O Manager for Alarm Unit

Figure 97. Dialog Box to Configure External 2 Source

9. Follow steps 3-7 if you want to define the second alarm input per camera. 10. Click Next. The Step 3 screen appears.
Page 75 of the Pelco DX9100 user manual — RECORDER
Pagina 75 · klik om te vergroten
Pagina 75

CONNECTING A RELAY UNIT

To connect a CM9760-REL to a DX9200 recorder using RS-232 communication:

1. Connect a null modem cable from the relay unit’s RS-232 port to the recorder’s COM 1 or COM 2 port.
2. Set the DIP switches on the relay unit for RS-232 communication. Refer to the CM9760-REL Installation/Operation manual.

If using RS-422 communication:

1. Connect a cable from the relay unit’s RJ-45 COM IN port to the recorder’s RS-232 port via an RS-232 to RS-422 converter.
2. Set the DIP switches on the relay unit for RS-422 communication. Refer to the CM9760-REL Installation/Operation manual.

RECORDER

Pelco DX9100 — RECORDER diagram (page 75)
Afb. 91

Figure 98. Connecting a CM9760-REL

Page 76 of the Pelco DX9100 user manual — RELAY UNIT CONFIGURATION
Pagina 76 · klik om te vergroten
Pagina 76

RELAY UNIT CONFIGURATION

Follow these steps to configure a CM9760-REL relay unit.

1. Go to Start > Programs > DX9000 Server > IO Handler Configuration. The following dialog box appears.

Figure 99. Relay I/O Handler Dialog Box

2. Click Select Driver on Device 1 (COM 1) or Device 2 (COM 2) to define the external device driver that is connected to the server. The following dialog box appears.
Pelco DX9100 — RELAY UNIT CONFIGURATION diagram (page 76)
Afb. 92

Figure 100. CM9760 Relay Driver Dialog Box

3. Select CM9760REL.dll.
Page 77 of the Pelco DX9100 user manual — RELAY UNIT CONFIGURATION
Pagina 77 · klik om te vergroten
Pagina 77
4. Click Open. The following dialog box appears.
Pelco DX9100 — RELAY UNIT CONFIGURATION diagram (page 77)
Afb. 93

Figure 101. Device 1 Relay Driver Dialog Box

5. Click Configure. The following dialog box appears.
Pelco DX9100 — RELAY UNIT CONFIGURATION diagram (page 77)
Afb. 94

Figure 102. CM9760 Relay Configuration Dialog Box

6. Set the baud rate to 9600 and the parity to Even. The relay unit should have these same settings.
7. Enter 1 or 2 in the COM Port field. This is the port on the recorder that connects to the relay unit.
8. Set the default latch time. This time activates the relays on the relay unit and sets the same latch time for all of the relay ports. The default is 5 seconds.
9. Add latch times for specific relays.
10. Click OK.
11. Click Test.
12. Close the I/O Handler Configuration application.
Page 78 of the Pelco DX9100 user manual — I/O Manager for Relay Unit
Pagina 78 · klik om te vergroten
Pagina 78

I/O Manager for Relay Unit

The Step 3 and Step 4 screens in the I/O Manager Configuration are used to finish configuring a relay unit. Step 3 configures the recorder channels with the selected relay ports. Step 4 translates the event type from one type to another.

If you are already in the I/O Manager Configuration, follow the steps below.

If you are not in the I/O Manager Configuration, go to Start > Programs > DX9000 Server > IO Manager Configuration. In the I/O Manager Configuration, click Next three times to reach Step 3.

Refer to Figure 103 for the following steps.

1. Select the channel or channels that will send events to the relay unit.
2. Enter the server name that the relay unit is connected to.
3. Select the device as configured in the I/O Handler. This is the logical device number that the relay unit is connected to.
4. Enter the relay port number that the selected channel will send events to. If several channels are selected, this number specifies the related port of the first channel. For example, if eight channels are selected, port 0 relates to channel 0 and so on.
5. Click OK. The information you entered appears on the screen.
Pelco DX9100 — I/O Manager for Relay Unit diagram (page 78)
Afb. 95 · I/O Manager for Relay Unit

Figure 103. Relay Unit Step 3 Screen

Page 79 of the Pelco DX9100 user manual — I/O Manager for Relay Unit
Pagina 79 · klik om te vergroten
Pagina 79
6. Click Next. The following dialog box appears.
Pelco DX9100 — I/O Manager for Relay Unit diagram (page 79)
Afb. 96 · I/O Manager for Relay Unit

Figure 104. Dialog Box to Configure Relay Event Type

7. Select the event type to translate.
8. Select “No translation.” 9. Click OK and then Finish.
Page 80 of the Pelco DX9100 user manual — CONNECTING A CM9760-CC1
Pagina 80 · klik om te vergroten
Pagina 80

CONNECTING A CM9760-CC1

To connect a CM9760-CC1 to a DX9200 recorder, you must use a CM9760-DT.

1. Connect a null modem cable from the CM9760-DT’s COM A port to the recorder’s COM 1 or COM 2 port. 2. Connect a null modem cable from the CM9760-DT’s COM B port to the COM 1 or COM 2 port on the CM9760-CC1. 3. Set the jumpers in the data translator for baud rate and parity. Refer to the CM9760-DT Installation/Operation manual.
Pelco DX9100 — CONNECTING A CM9760-CC1 diagram (page 80)
Afb. 97

PRINTER PRINTER COM 1 COM 1 COM 2 COM 2

Page 81 of the Pelco DX9100 user manual — RS-232 TO RS-422 CONVERTER
Pagina 81 · klik om te vergroten
Pagina 81

CONNECTING A CM6800

The CM6800 external alarm files must be set up correctly. You must set auto reset on the CM6800 to acknowledge alarms. Refer to the CM6800 Installation/Operation manual.

To connect a CM6800 to a DX9200 recorder:

1. Connect a null modem cable from the recorder’s COM 1 or COM 2 port to COM 1 (RS-232) on the CM6800. 2. Set the RS-232 COM 1 port on the CM6800 as ASCII. 3. Set the baud rate on the CM6800 to match the baud rate on the recorder.

You can also connect to the additional ASCII ports on the CM6800 via an RS-232 to RS-422 converter. Refer to the CM6800 or CM6800E manuals for the correct ASCII ports.

RECORDER

Pelco DX9100 — RECORDER diagram (page 81)
Afb. 98

NULL MODEM CABLE

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

RS-232 TO RS-422 CONVERTER

32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17

8 7 6 5 48 47 46 45 40 39 38 37 36 35 34 33

ALT 12 0/230 ~ 50/ 60 HZ 25 WATTS

Figure 106. Connecting a CM6800

Page 82 of the Pelco DX9100 user manual — DATA TRANSLATOR CONFIGURATION
Pagina 82 · klik om te vergroten
Pagina 82

DATA TRANSLATOR CONFIGURATION

Integrating a data translator serves two functions:

  • Synchronize time between the DX9200 system and the matrix switcher.
  • Send ASCII command strings to the matrix switcher (CM6800/CM9740/CM9760) for alarm conditions, such as sending alarms based on motion detection.

Follow these steps to configure a data translator unit.

1. Go to Start > Programs > DX9000 Server > IO Handler Configuration. The following dialog box appears.

Figure 107. Data Translator I/O Handler Configuration Dialog Box

2. Click Select Driver on Device 1 (COM 1) or Device 2 (COM 2) to define the external device driver that is connected to the server. The following dialog box appears.
Pelco DX9100 — DATA TRANSLATOR CONFIGURATION diagram (page 82)
Afb. 99

Figure 108. CM9760 Data Translator Driver Dialog Box

3. Select CM9760DT.dll.
Page 83 of the Pelco DX9100 user manual — DATA TRANSLATOR CONFIGURATION
Pagina 83 · klik om te vergroten
Pagina 83
4. Click Open. The following dialog box appears.
Pelco DX9100 — DATA TRANSLATOR CONFIGURATION diagram (page 83)
Afb. 100

Figure 109. Device 1 Data Translator Driver Dialog Box

5. Click Configure. The following dialog box appears.
Pelco DX9100 — DATA TRANSLATOR CONFIGURATION diagram (page 83)
Afb. 101

Figure 110. CM9760 Relay Configuration Dialog Box

6. Set the baud rate to 4800 and the parity to Even. The data translator should have these same settings.
7. Enter 1 or 2 in the COM Port field. This is the physical port on the recorder that connects to the data translator.
8. Set the Time Synch Update. This is the interval that the recorder updates the CM9760 clock. The default is 21,600 seconds (6 hours).
9. Click OK.
10. Click Test.
11. Close the I/O Handler Configuration application.
Page 84 of the Pelco DX9100 user manual — I/O Manager for Data Translator
Pagina 84 · klik om te vergroten
Pagina 84

I/O Manager for Data Translator

The Step 3 and Step 4 screens in the I/O Manager Configuration are used to configure the data translator. Step 3 configures the recorder channels with the selected data translator. Step 4 translates the event type from one type to another.

If you are already in the I/O Manager Configuration, follow the steps below.

If you are not in the I/O Manager Configuration, go to Start > Programs > DX9000 Server > IO Manager Configuration. In the I/O Manager Configuration, click Next three times to reach Step 3.

Refer to Figure 86 for the following steps.

1. Select the channel(s) you want to configure with the data translator.
2. Enter the server name that the data translator is connected to.
3. Select the device as configured in the I/O Handler. This is the logical device number that the data translator is connected to.
4. In the Port field, enter the alarm number you want to activate in the matrix switcher.
5. Click OK. The information you entered appears on the screen.

Figure 111. Dialog Box to Configure Data Translator

Page 85 of the Pelco DX9100 user manual — I/O Manager for Data Translator
Pagina 85 · klik om te vergroten
Pagina 85
6. Click Next. The following dialog box appears.

Figure 112. Dialog Box to Configure Data Translator Event Type

7. Select the event type to translate.
8. Select “No translation.”
9. Click OK and then Finish.
Page 86 of the Pelco DX9100 user manual — VIEWSTATION
Pagina 86 · klik om te vergroten
Pagina 86

DVR MANAGEMENT

If the DX9200 DVR system is connected to a matrix switcher, the operation of the system can be managed with the Server Alert Configuration Utility. If recorders are not recording or there is no communication with recorders, this utility sends alarms to the matrix switcher.

If the DX9200 system is connected to a Pelco matrix switcher, such as the CM9740 or CM9760, alarms are sent through a data translator. For non-Pelco matrix switchers, alarms are sent through a relay unit.

DATA TRANSLATOR CONNECTIONS

The CM9760-DT should be used with Pelco matrix switchers, such as the CM9740 or CM9760.

1. Connect a null modem cable from the CM9760-DT’s COM A port to the COM 1 or COM 2 port on the viewstation. 2. Connect a null modem cable from the CM9760-DT’s COM B port to the COM 1 or COM 2 port on the CM9760-CC1. 3. Set the jumpers in the data translator for baud rate and parity. Refer to the CM9760-DT Installation/Operation manual.

VIEWSTATION

Pelco DX9100 — VIEWSTATION diagram (page 86)
Afb. 102

PRINTER PRINTER COM 1 COM 1 COM 2 COM 2

Figure 113. Connecting a CM9760-DT for DVR Management

Page 87 of the Pelco DX9100 user manual — CONFIGURING THE DATA TRANSLATOR
Pagina 87 · klik om te vergroten
Pagina 87

CONFIGURING THE DATA TRANSLATOR

1. Go to Start > Programs > DX9000 Viewstation > Server Alert Configuration Utility. The following dialog box appears.
Pelco DX9100 — CONFIGURING THE DATA TRANSLATOR diagram (page 87)
Afb. 103

Figure 114. Data Translator Configuration Dialog Box

2. Click Select. The following dialog box appears.
Pelco DX9100 — CONFIGURING THE DATA TRANSLATOR diagram (page 87)
Afb. 104

Figure 115. Data Translator Driver Dialog Box

3. Select CM9760DT.dll.
4. Click Open. The following dialog box appears.
Pelco DX9100 — CONFIGURING THE DATA TRANSLATOR diagram (page 87)
Afb. 105

Figure 116. Data Translator Driver Settings Dialog Box

5. Enter the offset number in the Server Alert Settings box.
Page 88 of the Pelco DX9100 user manual — DVR MANAGEMENT
Pagina 88 · klik om te vergroten
Pagina 88
6. Click Configure. The following dialog box appears.
Pelco DX9100 — DVR MANAGEMENT diagram (page 88)
Afb. 106

Figure 117. CM9760-DT Configuration

7. Set the baud rate to 4800 and the parity to Even. The data translator should have these same settings.
8. Enter the COM Port number. This is the port on the viewstation that connects to the data translator.
9. Click OK.
10. Click Test.
11. Click OK on the Server Alert Configuration screen to save your settings.
Page 89 of the Pelco DX9100 user manual — OR
Pagina 89 · klik om te vergroten
Pagina 89

RELAY UNIT CONNECTIONS

You can connect up to four relay units to each viewstation. The CM9760-REL should be used with third-party matrix switchers for hard-wired alarm integration.

To connect a CM9760-REL to a DX9100 viewstation using RS-232 communication:

1. Connect a null modem cable from the relay unit’s RS-232 port to the viewstation’s RS-232 port.
2. Set the DIP Switches on the relay unit for RS-232 communication. Refer to the CM9760-REL Installation/Operation manual.

If using RS-422 communication:

1. Connect a cable from the relay unit’s RJ-45 COM IN port to the viewstation’s COM 1 or COM 2 port via an RS-232 to RS-422 converter.
2. Set the DIP Switches on the relay unit for RS-422 communication. Refer to the CM9760-REL Installation/Operation manual.
Pelco DX9100 — RELAY UNIT CONNECTIONS diagram (page 89)
Afb. 107

OR

Pelco DX9100 — OR diagram (page 89)
Afb. 108

Figure 118. Connecting a CM9760-REL for DVR Management

Page 90 of the Pelco DX9100 user manual — CONFIGURING THE RELAY UNIT
Pagina 90 · klik om te vergroten
Pagina 90

CONFIGURING THE RELAY UNIT

1. Go to Start > Programs > DX9000 Viewstation > Server Alert Configuration Utility.

Figure 119. Relay Unit Configuration Dialog Box

2. Click Select. The following dialog box appears.
Pelco DX9100 — CONFIGURING THE RELAY UNIT diagram (page 90)
Afb. 109

Figure 120. Relay Unit Driver Dialog Box

3. Select CM9760REL.dll.
4. Click Open. The following dialog box appears.
Pelco DX9100 — CONFIGURING THE RELAY UNIT diagram (page 90)
Afb. 110

Figure 121. Relay Unit Driver Settings Dialog Box

5. Enter the relay number in the Server Alert Settings box. The first relay starts with 0.
Page 91 of the Pelco DX9100 user manual — DVR MANAGEMENT
Pagina 91 · klik om te vergroten
Pagina 91
6. Click Configure. The following dialog box appears.
Pelco DX9100 — DVR MANAGEMENT diagram (page 91)
Afb. 111

Figure 122. CM9760-REL Configuration Dialog Box

7. Set the baud rate to 9600 and the parity to Even. The relay unit should have these same settings.
8. Enter the COM Port number. This is the port on the viewstation that connects to the relay unit.
9. Change the default latch time. This time activates the relays on the relay unit and sets the same latch time for all of the relay ports. The default is 5 seconds.
10. Add latch times for specific relays.
11. Click OK.
12. Click Test.
13. Click OK on the Server Alert Configuration screen.
Page 92 of the Pelco DX9100 user manual — FOREIGN LANGUAGE PROGRAMMING
Pagina 92 · klik om te vergroten
Pagina 92

FOREIGN LANGUAGE PROGRAMMING

This programming is applicable to the viewstation only. You can select only the following locations for use with the DX9200 system:

  • English (United States)
  • French (France)
  • German (Germany)
  • Italian (Italy)
  • Polish
  • Portuguese (Brazil)
  • Russian
  • Chinese (PRC)
  • Spanish (Spain)

In the example below, the location is changed from the default English (United States) to Spanish (Spain).

1. Double-click My Computer > Control Panel > Regional Options. The following page appears.
Pelco DX9100 — FOREIGN LANGUAGE PROGRAMMING diagram (page 92)
Afb. 112

Figure 123. Change System Location

2. Change the location to Spanish (Spain).
3. Click Apply.
Page 93 of the Pelco DX9100 user manual — DVR MANAGEMENT
Pagina 93 · klik om te vergroten
Pagina 93
4. Click Set Default. The following dialog box appears.
Pelco DX9100 — DVR MANAGEMENT diagram (page 93)
Afb. 113

Figure 124. Select System Location

5. Select the same location. 6. Click OK. 7. Click Apply. 8. Click Yes to skip file copying and use existing files. 9. Click Yes to restart your computer.

The new settings take effect after the computer reboots. The DX9200 will support Spanish settings for numbers, currency, times, dates, menu strings, and text translations.

Follow these same steps to change the location back to English (United States) or to select another location.

Page 94 of the Pelco DX9100 user manual — PHILLIPS PAN HEAD SCREW
Pagina 94 · klik om te vergroten
Pagina 94

SERVICE

HOW TO REPLACE A RECORDER’S POWER SUPPLY

The two power supplies on the back of the recorder are redundant, hot-swappable. When a power supply fails, the green power LED on the power supply turns off and an alarm sounds. Refer to the illustration and steps below.

PHILLIPS PAN HEAD SCREW

POWER SUPPLY RESET BUTTON

POWER CABLE

HANDLE

POWER SWITCH

POWER LED

Figure 125. Power Supply Replacement

1. Press the red power supply reset button to turn off the alarm. 2. Turn off the power supply switch on the failed power supply. 3. Unplug the power cable from the failed power supply. 4. Remove the Phillips, pan head screw. 5. Pull out the defective power supply using the handle. 6. Slide the new power supply into the unit. 7. Tighten the Phillips, pan head screw. 8. Plug the power cable to the new power supply. 9. Turn on the power supply switch on the new power supply.

Page 95 of the Pelco DX9100 user manual — HOW TO REPLACE A RECORDER’S RAID 1 DRIVE
Pagina 95 · klik om te vergroten
Pagina 95

HOW TO REPLACE A RECORDER’S RAID 1 DRIVE

Before you replace a failed drive, you must open the Promise Array Management Utility to verify which drive has failed.

To open the Promise Array Management Utility:

1. Go to Start > Programs > Promise Array Management > Remote Monitoring Utility. The following window appears.
Pelco DX9100 — HOW TO REPLACE A RECORDER’S RAID 1 DRIVE diagram (page 95)
Afb. 114

Figure 126. Raid Server Window

2. Right-click on the desired recorder name and select Login. (The default recorder name is Pelco 1.) The following window appears. The Username is administrator and the Password is 1234 .
Pelco DX9100 — HOW TO REPLACE A RECORDER’S RAID 1 DRIVE diagram (page 95)
Afb. 115

Figure 127. Login Window

3. Click OK. 4. Double-click PELCO1 to expand the recorder tree.
Page 96 of the Pelco DX9100 user manual — DVR MANAGEMENT
Pagina 96 · klik om te vergroten
Pagina 96
Pelco DX9100 — DVR MANAGEMENT diagram (page 96)
Afb. 116

Figure 128. Remote Monitor Window

5. Double-click FASTTRAK to see FTP1 and Ary1.
Pelco DX9100 — DVR MANAGEMENT diagram (page 96)
Afb. 117

Figure 129. Fast Trak Window

6. Double-click Ary1 to see the two internal hard drives.
Page 97 of the Pelco DX9100 user manual — DVR MANAGEMENT
Pagina 97 · klik om te vergroten
Pagina 97
Pelco DX9100 — DVR MANAGEMENT diagram (page 97)
Afb. 118

Figure 130. Array Window

7. Select ch2. The following window shows that the second hard drive is functional.
Pelco DX9100 — DVR MANAGEMENT diagram (page 97)
Afb. 119

Figure 131. Drive 2 Status

Page 98 of the Pelco DX9100 user manual — DRIVE CAGE PHILLIPS FLAT HEAD SCREW
Pagina 98 · klik om te vergroten
Pagina 98
8. Select ch1. The following window shows that the first hard drive is offline and has failed.
Pelco DX9100 — DVR MANAGEMENT diagram (page 98)
Afb. 120

Figure 132. Drive 1 Status

9. Turn the recorder off and disconnect all cables. 10. Remove the top cover from the recorder.

DRIVE CAGE PHILLIPS FLAT HEAD SCREW

PHILLIPS PAN HEAD SCREW

HARD DRIVE 1 HARD DRIVE 2

Figure 133. Hard Drive Replacement

11. Remove the four Phillips, pan head screws from the top corners of the cage. 12. Lift the cage and unplug all cables from the hard drives and floppy drive. 13. Remove the cage from the chassis. 14. Remove the four Phillips, flat head screws with washers from the failed drive. There are two screws on the top of the cage and two on the bottom of the cage. 15. Remove the failed drive.
Page 99 of the Pelco DX9100 user manual — DVR MANAGEMENT
Pagina 99 · klik om te vergroten
Pagina 99
16. Slide the new drive into the cage. 17. Tighten the four Phillips, flat head screws with washers. 18. Plug all cables to the hard drives and floppy drive. 19. Place the cage into the chassis and tighten it using the four Phillips, pan head screws. 20. Place the top cover on the recorder. 21. Connect all cables and turn the recorder on. The recorder automatically rebuilds the system array. The Remote Monitoring Utility shows the following.
Pelco DX9100 — DVR MANAGEMENT diagram (page 99)
Afb. 121

Figure 134. Rebuilding System Array

Page 100 of the Pelco DX9100 user manual — SPECIFICATIONS
Pagina 100 · klik om te vergroten
Pagina 100

SPECIFICATIONS

RECORDER Electrical/Video Input Voltage: 100-240 VAC, 50/60 Hz, autoranging. Reset feature enabled when power becomes unstable or interrupted. Power Consumption: 265 W maximum, redundant hot-swappable Signal System: NTSC/PAL, autosensing Operating System: Windows 2000 and SP3 Service Pack Recording Resolution NTSC (DX9200H): 352 x 240 (CIF) at 7.5 or 15 ips PAL (DX9200H): 352 x 288 (CIF) at 6.25 or 12.5 ips NTSC (DX9200F): 352 x 240 (CIF) at 7.5, 15, or 30 ips 704 x 240 (2CIF) at 7.5 or 15 ips PAL (DX9200F): 352 x 288 (CIF) at 6.25, 12.5, or 25 ips 704 x 288 (2CIF) at 6.25 or 12.5 ips Recording Speed NTSC (DX9200H): 7.5 or 15 ips PAL (DX9200H): 6.25 or 12.5 ips NTSC (DX9200F): 7.5, 15, or 30 ips PAL (DX9200F): 6.25, 12.5, or 25 ips Compression: MPEG-1 Video Inputs: 16/32/48 maximum 15 ips 8/16/24/32/40 maximum 30 ips Video Outputs: 1 SVGA Remote Control: Full remote control via TCP/IP

Mechanical Connectors BNC: Up to 48 video inputs on patch panel BNC: Up to 48 looping video outputs on patch panel SCSI Interface: Two ports available DB37: 1-6 ports available DB9: COM 1 and 2 RJ-45: Ethernet port (10/100BASET) USB: One port available 6-pin mini-DIN: PS/2 mouse and keyboard DB15, SVGA: Monitor port Audio Inputs: Not used DIN5: AT keyboard connector (not used)

General Operating Temperature: 41° to 85°F (5° to 29°C) Relative Humidity: Maximum 80%, non-condensing Dimensions

Desktop: 7.1 (H) x 17.0 (W) x 22.1 (D) inches (18.1 x 43.0 x 56.2 cm) Rack-Mount: 7.0 (H) x 19.0 (W) x 19.6 (D) inches (17.8 x 48.3 x 49.8 cm) Unit Weight: 53.7 lb (24.4 kg) maximum

Page 101 of the Pelco DX9100 user manual — DVR MANAGEMENT
Pagina 101 · klik om te vergroten
Pagina 101

VIEWSTATION Electrical Input Voltage: 100-240 VAC, 50/60 Hz, autoranging Power Consumption: 90 W maximum Operating System: Windows 2000 and SP2 Service Pack

Mechanical Connectors 6-pin mini-DIN PS/2 mouse and keyboard DB9 Two RS-232 COM ports available for external devices DB15 SVGA monitor port (1024 x 768) DB15 Composite monitor port (analog adapter provided) DB25 Printer port RJ-11 Internal modem (for use with pcAnywhere software only) RJ-45 Ethernet port (10/100BaseT) Ethernet port (10/100/1000BaseT) USB Two ports available RCA Audio output (reserved for future use) Hardware Processor Pentium® 4, 2.4 GHz RAM 512 MB DDR Video card ATI Radeon™ 9600 PRO Modem V.90/56K Drive DVD-RW/CD-RW

General Operating Temperature: 41° to 85°F (5° to 29°C) Relative Humidity: Maximum 80%, non-condensing Dimensions

Desktop: 7.3 (H) x 17.0 (W) x 19.6 (D) inches (18.5 x 43.2 x 49.8 cm) Rack-Mount: 7.0 (H) x 19.0 (W) x 19.6 (D) inches (17.8 x 48.3 x 49.8 cm) Unit Weight: 33 lb (15.0 kg)

Page 102 of the Pelco DX9100 user manual — DVR MANAGEMENT
Pagina 102 · klik om te vergroten
Pagina 102
Page 102 of the Pelco DX9100 user manual — DVR MANAGEMENT
Page 103 of the Pelco DX9100 user manual — REVISION HISTORY
Pagina 103 · klik om te vergroten
Pagina 103

WARRANTY AND RETURN INFORMATION

WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.

If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:

1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem

Exceptions to this warranty are as noted below:

  • Five years on the following fixed camera models: CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X.
  • Three years on all other fixed camera models (including Camclosure ® Integrated Camera Systems) and Genex ® Series (multiplexers, server, and keyboard).

If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.

  • Two years on all standard motorized or fixed focal length lenses.

Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

  • Two years on Legacy ® , CM6700/CM6800/CM8500/CM9500/CM9700 Series Matrix, DF5 and DF8 Series Fixed Dome products.
  • Two years on Spectra ® , Esprit ® , and PS20 Scanners, including when used in continuous motion applications.

RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).

  • Two years on Esprit ® and WW5700 series window wiper (excluding wiper blades).
  • Eighteen months on DX Series digital video recorders and NVR300 network video recorders.

All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.

  • One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.

Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.

  • Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).

If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:

Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.

Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699

Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.

If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:

If the goods are to be sent by a COURIER SERVICE, send the goods to:

If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:

Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA

Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933

The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.

REVISION HISTORY

Manual # Date Comments C634M 10/03 Original version. C634M-A 2/04 Updated Important Safety Instructions. Updated Database Backup and Repair section. Added Database Restoration section. Revised Step 3 in Viewstation IP Address section. Updated Warranty and Return Information. C634M-B 3/04 Moved„ Gateway Configuration Settings and Viewstation IP Address sections to Raid Manager Utility section. C634M-C 6/04 Revised manual to include DVD-RW/CD-RW drive and ATI Radeon 9600 PRO video card. Moved Regulatory Notices. C634M-D 12/04 Added Step 6 to the Netsend Setting section on page 49.

Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco. Windows is a registered trademark of Microsoft Corporation. pcAnywhere is a trademark of Symantec. Radeon is a trademark of ATI Technologies Inc. Pentium is a registered trademark of Intel Corporation. © Copyright 2004, Pelco.All rights reserved.

Page 104 of the Pelco DX9100 user manual — ISO 9001
Pagina 104 · klik om te vergroten
Pagina 104

3500 Pelco Way Clovis, California 93612 USA

USA & Canada Tel800/289-9100 Fax: 800/289-9150
International Tel1-559/292-1981 Fax: 1-559/348-1120

www.pelco.com

ISO 9001

Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada Singapore

® · World Headquarters

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Pelco DX9100

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Pelco DX9100

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Pelco DX9100 handleiding-pdf

104 pagina's·8.1 MB·DVR·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…