IPS-RDPE-2 Remote Data Port INSTALLATION/OPERATION C2473M-C (8/06).
.
C2473M-C (8/06) 3 Contents Important Safe ty Instruct ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description .
4 C2473M-C (8/06) Important Safety Instructions Prior to installation an d use of this product, the following warnings shou ld be obser ved. 1. Installation and servicin g should be done only by qu alified service personnel and conform to all local codes.
C2473M-C (8/06) 5 Description Pelco’ s IPS-RDPE-2 dat a port box is an on-sit e service too l designed f or Spectra III ™ SE, Spectra III, Esprit ® , and ExSit e ™ Series positioning systems. The d ata port b ox gives on -site acc ess for setu p and testi ng of the p ositioning system.
6 C2473M-C (8/06) Mounting Instructions W ALL MOUNTING 1. Open the lid of the IPS-RDPE-2 box. Install two 3/4-inch (1.9 1 cm) conduit fittings (not supp lied). Close the lid of the IPS- RDPE-2 box. 2. Determin e the mounting lo cation for the IPS-RDP E-2.
C2473M-C (8/06) 7 POLE MOUNTING 1. Install the P A402 mount adap ter . Refer t o the instruct ions supplie d with the ad apter . 2. Open the lid of the IPS-RDPE-2 box. Install two 3/4-inch (1.9 1 cm) conduit fittings (not supp lied). Close the lid of the IPS- RDPE-2 box.
8 C2473M-C (8/06) Cable/Wire Requirements and Connector Locations Refer to Figure 3 for a layou t of the data port box connector s. It is important to connec t all four communication wires from the IPS-RDPE-2 to the Spectra III dome system or ExSite system.
C2473M-C (8/06) 9 Wiring Diagrams The IPS-RDPE-2 is design ed to work in both coaxia l cable and un shi elded twisted pair (UTP) vide o transmis sion s ystems.
10 C2473M-C (8/06) Figure 5. Coaxitron Controller with UTP Video – Passive Receiver Only NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG.
C2473M-C (8/06) 11 Figure 6. RS-422 (D or P Protocol) Controller with Coax Video – Point-to-Point Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximum wire gaug e allowed for two-wire communication is 16 A WG.
12 C2473M-C (8/06) Figure 7. RS-422 (D or P Protocol) Controller with Coax Video – Home Run Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximum wire gaug e allowed for two-wire communication is 16 A WG.
C2473M-C (8/06) 13 Figure 8. RS-422 (D or P Protocol) Controller with Coax Video – Daisy-Chain Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximum wire gaug e allowed for two-wire communication is 16 A WG.
14 C2473M-C (8/06) Figure 9. RS-422 (D or P Protocol) Controller with UTP Video – Point-to-Point Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG.
C2473M-C (8/06) 15 Figure 10. RS-422 (D or P Protocol) Controller wit h UTP Video – Home Run Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG.
16 C2473M-C (8/06) Figure 11. RS-422 (D or P Protocol) Controller wit h UTP Vid eo – Daisy-Chain Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG.
C2473M-C (8/06) 17 Operation T o view video, control pan /tilt/zoom, or upload rev ised operat ing software a nd language files to a p ositioning s ystem, do the f ollowing: 1. Open th e door of t he IPS-RDPE-2. Opening the door will auto matically disconne ct the controller at the head-e nd and trigger an audible alert at the IPS-RD PE-2 site .
18 C2473M-C (8/06) Specifications ELECTRICAL Input V oltage 24 V AC Power Consumpt ion 1 V A Does not inc lude power required fo r position ing system MECHANICAL Construction Aluminum Finish Gray polyester powder coat Cable Entry T wo hole plugs will accommodate 3/4-inch (1.
The materials used in the manufacture of this docume nt and it s components are compliant to the requirements of Directive 2002/9 5/EC. This equipment contains elec trical or electronic components tha.
W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Een belangrijk punt na aankoop van elk apparaat Pelco IPS-RDPE-2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco IPS-RDPE-2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco IPS-RDPE-2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco IPS-RDPE-2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco IPS-RDPE-2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco IPS-RDPE-2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco IPS-RDPE-2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco IPS-RDPE-2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.