Gebruiksaanwijzing /service van het product IPSXM-7 van de fabrikant Pelco
Ga naar pagina of 16
INSTALLATION ExSite ™ Series Explosionproof Power Module C313M-D (8/05) IPSXM-2 and IPSXM-7.
.
C313M-D (8/05) 3 Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Getting Started .
4 C313M-D (8/05) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’ s instructions.
C313M-D (8/05) 5 Getting Started Thank you for purchasing Pelco’ s ExSite ™ Series explosionproof integrated positioning system. This manual includes instructions for installing the power module for the ExSite Series system. For complete system installation instructions refer to the installation manual placed in the pan and tilt box.
6 C313M-D (8/05) Install the Power Module Attach the power module to the mounting surface. Use only installation methods and materials capable of supporting four times the maximum specified load of the system (220 lb/100 kg). NOTE: If required, install the optional TXB translator , fiber module, or UTP board before installing the power module.
C313M-D (8/05) 7 Connect Wiring Refer to the following information to connect the wires and cables as required. NOTES: • Relay 3 is allocated specifically for an external washer (not supplied by Pelco). • All relays are specified for 32 VDC, 0.5 A.
8 C313M-D (8/05) DIP Switch Settings Configure the receiver address, termination, and baud setting for the system. The DIP switches to configure these settings are located on the top of the power module. NOTE: No DIP switch settings are required for Coaxitron ® control.
C313M-D (8/05) 9 T ables ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 1 OFF OFF OFF OFF OFF OFF OFF OFF 2 ON OFF OFF OFF OFF OFF OFF OFF 3 OFF ON OFF OFF OFF OFF OFF OFF 4 ON.
10 C313M-D (8/05) ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OFF ON ON OFF OFF 52 OFF OFF ON OF.
C313M-D (8/05) 11 T able B. D Protocol Receiver Address (Continued) ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 143 ON ON ON ON OFF OFF OFF ON 144 OFF OFF OFF OFF ON OFF OFF.
12 C313M-D (8/05) ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 239 ON ON ON ON OFF ON ON ON 240 OFF OFF OFF OFF ON ON ON ON 241 ON OFF OFF OFF ON ON ON ON 242 OFF ON OFF OFF .
C313M-D (8/05) 13 Specifications ELECTRICAL Input V oltage 24 V AC or 100-240 VAC Input V oltage Range ±10% Power Consumption Maximum 60 watts (120 V A) per system Electrical Connections 6-foot wire harness with connections for power , video, data control, alarm inputs, and auxiliary outputs MECHANICAL Cable Entry One 0.
14 C313M-D (8/05).
PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Een belangrijk punt na aankoop van elk apparaat Pelco IPSXM-7 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco IPSXM-7 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco IPSXM-7 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco IPSXM-7 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco IPSXM-7 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco IPSXM-7 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco IPSXM-7 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco IPSXM-7 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.